MAURY USCG vessel records
← All vessels

WEB P2

Built
2009
Last inspected
8 September 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 8 September 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 13 calendar years (2009–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

997712
Flag
UNITED STATES
Maury page id
psix-997712

Documentation record

Registered dimensions (L × B × D)250.0 ft × 50.0 ft × 13.0 ft
Registered tonnagegross 1,365 / net 1,365
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSNEED SHIPBUILDING INC · CHANNELVIEW, TX, UNITED STATES · built 2009
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 17 November 2025 · expires 30 November 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1365 - Simplified, Gross Ton
1365 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 22 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

JASON JOSEPH Towing Vessel · MISLE 183974 · 2 March 2023 · activity 7646821

Inspection history · 22

8 September 2025 Administrative Inspection · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8229379
16 October 2023 Administrative Inspection · Examination of Repairs · COI Inspection · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7809487
2 March 2023 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7646821
27 October 2021 Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7340908
9 November 2020 Administrative Inspection · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7092213
15 October 2018 COI Inspection · Administrative Inspection · In-Service Inspection · Internal Structural Exam · Cargo Tank Internal · Drydock Exam · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6561759
14 August 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6511603
23 May 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6421336
15 March 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6372292
21 July 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6215901
23 June 2017 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6184282
21 February 2017 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6091921
28 December 2015 MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5788027
30 January 2015 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5060204
10 January 2014 COI Inspection · MTSA Verification · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4781108
26 September 2013 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4722583
22 August 2012 MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4418828
8 August 2011 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4109289
29 December 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3917532
27 July 2010 MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3807166
9 September 2009 Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3590243
20 August 2009 Initial Certification · Internal Structural Exam · Drydock Exam · MTSA Verification · Administrative Inspection · Construction Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3571596

Deficiency record · 3

Deck/Cargo › Holds/Tanks › Hatch
Issued 23 June 2017 Resolved
Forward cargo hatches on both prt and stbd bottles leaking. Cargo pressure at 160 psi.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 July 2017
Resolved 24 July 2017
Resolution: Attending CG Marine Inspector witnessed testing of 02 installed gaskets. Witnessed airtest at 100.0 psi, all test satisfactory.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 30 January 2015 Resolved
Transfer procedures state that all valves should be labeled to indicate if they are in the "OPEN" or "CLOSED" position. The 1st starboard vapor valve labels have been removed.
Due 28 February 2015
Resolved 6 February 2015
Resolution: Vsl rep labeled the valves to idicate if they are in the "OPEN" or "CLOSED" position. Picture attached (label)
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 26 September 2013 Resolved
Vessel was determined to have a safety relief valve on the cargo discharge piping within ten feet of electrical equipment not approved as Class I Div I compliant. Safety Relief valve and electrical equipment must be separated by minimum 10 feet, or electrical equipment within 10 feet of safety relief valve must be verified to be intrinsically safe and explosion proof.
Condition: Design Flaw
Due 21 December 2013
Resolved 12 December 2013
Resolution: Received photos and documentation rectifying hazardous condition. Batteries which were located in vsl hazardous zone have been removed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.