Records from 2009 to 2025. Most recent: inspection, 8 September 2025.
Documentation record
Registered dimensions (L × B × D)250.0 ft × 50.0 ft × 13.0 ft
Registered tonnagegross 1,365 / net 1,365
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSNEED SHIPBUILDING INC · CHANNELVIEW, TX, UNITED STATES · built 2009
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 November 2025 · expires 30 November 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1365 - Simplified, Gross Ton
1365 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
8 September 2025
Administrative Inspection · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8229379
16 October 2023
Administrative Inspection · Examination of Repairs · COI Inspection · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7809487
2 March 2023
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7646821
27 October 2021
Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7340908
9 November 2020
Administrative Inspection · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7092213
15 October 2018
COI Inspection · Administrative Inspection · In-Service Inspection · Internal Structural Exam · Cargo Tank Internal · Drydock Exam · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6561759
14 August 2018
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6511603
23 May 2018
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6421336
15 March 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6372292
21 July 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6215901
23 June 2017
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6184282
21 February 2017
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6091921
28 December 2015
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5788027
30 January 2015
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5060204
10 January 2014
COI Inspection · MTSA Verification · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4781108
26 September 2013
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4722583
22 August 2012
MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4418828
8 August 2011
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4109289
29 December 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3917532
27 July 2010
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3807166
9 September 2009
Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3590243
20 August 2009
Initial Certification · Internal Structural Exam · Drydock Exam · MTSA Verification · Administrative Inspection · Construction Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3571596
Deck/Cargo › Holds/Tanks › Hatch
Issued 23 June 2017
Resolved
Forward cargo hatches on both prt and stbd bottles leaking. Cargo pressure at 160 psi.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 July 2017
Resolved 24 July 2017
Resolution: Attending CG Marine Inspector witnessed testing of 02 installed gaskets. Witnessed airtest at 100.0 psi, all test satisfactory.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 30 January 2015
Resolved
Transfer procedures state that all valves should be labeled to indicate if they are in the "OPEN" or "CLOSED" position. The 1st starboard vapor valve labels have been removed.
Due 28 February 2015
Resolved 6 February 2015
Resolution: Vsl rep labeled the valves to idicate if they are in the "OPEN" or "CLOSED" position. Picture attached (label)
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 26 September 2013
Resolved
Vessel was determined to have a safety relief valve on the cargo discharge piping within ten feet of electrical equipment not approved as Class I Div I compliant. Safety Relief valve and electrical equipment must be separated by minimum 10 feet, or electrical equipment within 10 feet of safety relief valve must be verified to be intrinsically safe and explosion proof.
Condition: Design Flaw
Due 21 December 2013
Resolved 12 December 2013
Resolution: Received photos and documentation rectifying hazardous condition. Batteries which were located in vsl hazardous zone have been removed.