Inspection history · 51
11 August 2009
MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3544497
29 July 2009
Load Line/Change of Employment
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3544494
23 May 2006
MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2656805
16 June 2005
Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2385340
22 February 2005
Deficiency Check · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2277954
26 April 2004
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2066529
29 March 2004
MARPOL Annex I Examination · Internal Structural Exam · Periodic Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2033201
11 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963156
19 February 2003
Cargo Tank Internal · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1739537
20 January 2003
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1735035
20 February 2002
Annual Inspection · Internal Structural Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1487978
14 March 2001
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1464362
26 June 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 657419
22 June 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 77390
23 February 2000
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1372942
15 July 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 116869
26 March 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 130173
22 March 1999
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1372561
16 March 1998
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1437374
7 June 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 37160
17 March 1997
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1371701
1 April 1996
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1431606
17 February 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1078281
16 February 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 181678
24 August 1995
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 878557
10 July 1995
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 884206
6 April 1995
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1403917
27 March 1995
Construction Oversight
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1396263
15 March 1995
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1357058
6 March 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1425558
26 July 1994
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1180591
27 July 1993
Examination of Repairs · Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1354402
3 March 1993
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 843327
23 February 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 499173
20 July 1992
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 953395
21 June 1991
Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 904738
6 August 1990
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 915994
6 July 1990
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1242818
22 September 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1208472
20 September 1989
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1210246
13 September 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1039390
11 July 1988
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 897396
22 February 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 526457
26 August 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1030848
29 June 1987
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1010325
27 April 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1015177
2 December 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 443201
27 June 1986
Credit Drydock · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1305069
3 December 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 441037
24 June 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 987918
4 January 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 462067
Construction/Loadline › Penetrations
Issued 29 March 2004
Resolved
Re-new gaskets for all void spaces. Correct to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Void hatch cover gasket
Condition: Improper/Lack of Maintenance
Due 29 April 2004
Resolved 26 April 2004
Resolution: Letter from [name withheld] confirms correction.
Construction/Loadline › Hull › Hull Plating
Issued 29 March 2004
Resolved
Crop and re-new side shell and bottom longitudinal frames #1 thru #3 IWO bottom deep web longitudinal frame #1 (damage in starboard most fwd corner) in forward rake starboard side. Make repairs to the satisfaction of the attending marine inspector by next drydock scheduled for February 2005. LEGACY COMPONENT DESC: Forward rake (Starboard)
Condition: Damaged By Earlier Event
Due 23 February 2005
Resolved 22 February 2005
Resolution: Repaired.
Construction/Loadline › Hull
Issued 19 February 2003
Resolved
Renew all fractured welds in way of previous repairs were affected. LEGACY COMPONENT DESC: Weld
Condition: Unknown
Due 25 March 2003
Resolved 25 March 2003
Resolution: All weld repairs were completed satisfactorily.
Construction/Loadline › Structures
Issued 19 February 2003
Resolved
Crop and renew plate in way of fractures in the Port and Starboard bin wall (deck walls). LEGACY COMPONENT DESC: Bin Wall
Condition: Damaged By Earlier Event
Due 25 March 2003
Resolved 25 March 2003
Resolution: Steel was renewed in areas of fracture. Inserts were as follows: Port bin wall- 48"x 8''4" x ¼". Starboard bin wall-30"x 46" x ¼" and 10''6" x 21" x ¼".
Construction/Loadline › Hull › Side Shell
Issued 20 February 2002
Resolved
Locate source of leakage from cargo tank to stbd tank and affect permanent repairs.
Condition: Unknown
Due 28 February 2002
Resolved 20 February 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 20 February 2002
Resolved
Complete hydrostatic testing of cargo transfer system piping.
Condition: Improper/Lack of Maintenance
Due 20 February 2002
Resolved 20 February 2002
Resolution: Corrected
Fire Fighting
Issued 6 April 1995
Resolved
Provide vessel for inspection of portable fire extinguishers._x001C_
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Construction/Loadline
Issued 6 April 1995
Resolved
Provide vessel for inspection of ground tackle._x001C_
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Construction/Loadline
Issued 6 April 1995
Resolved
Provide vessel for inspection of hull openings._x001C_
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Deck/Cargo
Issued 6 April 1995
Resolved
Provide vessel for inspection of machinery ventilation._x001C_
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Construction/Loadline
Issued 6 April 1995
Resolved
Provide vessel for inspection of hull structure._x001C_
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Deck/Cargo
Issued 6 April 1995
Resolved
Provide vessel for inspection of pollution prevention._x001C_
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Deck/Cargo
Issued 6 April 1995
Resolved
Provide vessel for inspection of cargo transfer system._x001C_
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Deck/Cargo
Issued 6 April 1995
Resolved
Provide vessel for inspection of warning notices._x001C_
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Deck/Cargo
Issued 6 April 1995
Resolved
Provide vessel for inspection of cargo hose hydrostatic testing._x001C_
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Deck/Cargo
Issued 6 April 1995
Resolved
Provide vessel for inspection of transfer procedures._x001C_
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Deck/Cargo
Issued 6 April 1995
Resolved
Provide vessel for inspection of flame screens._x001C_
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Engineering
Issued 6 April 1995
Resolved
Provide vessel for inspection of cargo ventilation._x001C_
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Engineering
Issued 6 April 1995
Resolved
Provide vessel for inspection of pressure vessels._x001C_
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Deck/Cargo
Issued 6 April 1995
Resolved
Provide vessel for inspection of hull markings._x001C_
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Deck/Cargo
Issued 6 April 1995
Resolved
Provide vessel for inspection of cargo hatches._x001C_
Condition: Unknown
Due 16 May 1995
Resolved 16 May 1995
Deck/Cargo
Issued 6 July 1990
Resolved
PROVIDE WATERTIGHT COVERS FOR ALL GOOSENECK VENTS.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990
Construction/Loadline
Issued 6 July 1990
Resolved
CONDUCT 2 PSIG AIR TEST ON #3 STARBOARD CARGO TANK TO DETERMINE IF FORWARD TRANSVERSE BULKHEAD HAS A FRACTURE IN WAY OF STARBOARD LONGITUDINAL BULKHEAD AT UPPER TRANSVERSE HORIZONTAL STIFFENER.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990
Construction/Loadline
Issued 6 July 1990
Resolved
REPAIR MAIN DECK PENETRATION PORT SIDE COFFERDAM IN WAY OF DOORS.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990
Deck/Cargo
Issued 6 July 1990
Resolved
CLEAN UP ALL CARGO PUMP COMPARTMENTS INCLUDING DECKS. THESE SPACES ARE NOTTO BE USED AS STORAGE AREAS.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990
Electrical
Issued 6 July 1990
Resolved
PROPERLY SUPPORT ELECTRICAL WIRING IN ACCORDANCE WITH IEEE-45.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990
Accommodation/Occupational Safety
Issued 6 July 1990
Resolved
REPAIR AND PROVE PROPER OPERATION OF FORWARD EYEWASH STATION.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990
Deck/Cargo
Issued 29 June 1987
Resolved
VESSEL IS NOT TO CARRY NOXIOUS LIQUID SUBSTANCES (I.E. CAUSTIC SODA SOLUTION) UNTIL A PROCEDURES AND ARRANGEMENTS MANUAL HAS BEEN SUBMITTED TO AND RECEIVED BY COMMANDANT (G-MTH).
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Construction/Loadline
Issued 27 April 1987
Resolved
MAKE PERMANENT REPAIRS TO THE SALT BOX STRINGERS AND BUTTRESSES, CLEAT DOUBLER PLATE, AND HULL INDENTATION, ALL LOCATED ON PORT AFTER CORNER AT NEXT DRYDOCKING.
Condition: Unknown
Due 27 April 1987
Resolved 27 April 1987