Records from 2003 to 2026. Most recent: inspection, 24 July 2026.
Documentation record
Registered dimensions (L × B × D)52.3 ft × 22.0 ft × 9.6 ft
Registered tonnagegross 88 / net 59
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEYMARD & SONS SHIPYARD · HARVEY LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 December 2025 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it88 - Regulatory (Subpart C or D), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 32
24 July 2026
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8445809
13 June 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8158584
3 July 2024
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7948033
26 June 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7942995
3 November 2023
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7826461
29 August 2023
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7781101
8 June 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7708185
11 April 2023
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7666842
21 November 2022
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7598112
19 November 2022
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7605912
9 November 2022
Deficiency Check · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7591792
8 November 2022
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7596147
17 April 2022
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7433147
17 April 2022
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7478185
21 January 2022
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7385329
30 April 2021
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7186246
14 November 2019
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6855437
25 September 2019
In-Service Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6821223
25 September 2019
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6821678
8 August 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6869011
24 July 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6828520
19 March 2019
Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 6645844
5 September 2013
Administration
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4707129
15 February 2013
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4534071
7 June 2010
Administration
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3760283
6 October 2009
MTSA Verification · Administration · Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3610669
3 August 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2734874
31 July 2006
Uninspected Other · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2731128
6 July 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2418718
26 February 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2013464
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1998977
7 September 2003
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1899801
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 13 June 2025
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists that requires attention. The following must be provided; high bilge level. Alarms must be visible and audible at each operating station. Vessel's bilge alarm sounds in E/R but is not audible/visual from the pilothouse (operating station). 46 CFR 143.230
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2025
Resolved 20 June 2025
Resolution: Vessel submitted video of audible/visual alarm working in pilothouse.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 26 June 2024
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following systems must be equipped with gauges at the machinery location:
(1) Main engine lubricating oil pressure and main engine RPM;
(2) Main engine cooling water temperature. The gauge panel for the port main engine is unreadable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2024
Resolved 3 July 2024
Resolution: Electronic guage was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 November 2022
Resolved
Each towing vessel must have a means to monitor and control the amount of thrust, rudder angle, and direction of thrust, at each operating station. Vessel was unable to control the stbd propeller due to a tire being in the propeller.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 21 November 2022
Resolved 21 November 2022
Resolution: The tire was removed from the propeller.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 November 2022
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: (1) Be maintained to ensure proper operation.
Vessel experienced a fire on the starboard main engine causing damage to wiring and other associated equipment. Vessel is allowed a one time transit from Intergulf Marine, Houston, TX to shipyard in San Leon, TX. Vessel shall enact repairs to the satisfaction of a Coast Guard Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 29 November 2022
Resolved 15 November 2022
Resolution: Accepted tech report of items replaced/renewed. Attended vessel and verified repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 January 2022
Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 of § 141.370 for specified areas where the vessel operates. The vessel did not have the required amount of flares based on its operating location.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 January 2022
Resolution: Vessel obtained the correct amount of distress signals for its intended route.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 January 2022
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either: (1) Automatic, battery-operated with a duration of no less than 2 hours; or (2) Non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power. It was found that 02 emergency lights were inoperable.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 January 2022
Resolution: The emergency lights were repaired and operable.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 January 2022
Resolved
Flammable and combustible products must not be stored in machinery spaces. It was found there was excessive oily water in the engine room bilge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2022
Resolution: The bilge was pumped out and clear of oily water.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 January 2022
Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110, unless the towing vessel is limited to daytime operation, in which case no floating electric water light is required. Lights were not properly attached to lifebuoys.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2022
Resolution: The lights were properly attached to the lifebouys.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 30 April 2021
Resolved
Means must be provided for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Vessel did not have closure for 03 ventilation openings. Vessel stated that they use plastic covers, but the covers could not be shown to be fire rated. Install means to close all ventilation openings for a fire.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2021
Resolved 12 May 2021
Resolution: vessel rep provided evidence that enclosures met subchapter I
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 30 April 2021
Resolved
Each life float must be fitted with a lifeline, pendants, a painter, and floating electric water light approved under approval series 161.010. Life float did not have light. One was acquired during inspection and installed.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 30 April 2021
Resolved 30 April 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 30 April 2021
Resolved
Electrical conductors passing through watertight bulkheads must be installed so that the bulkhead remains watertight. Electrical penetrations in upper portion of forward engine room bulkhead were not watertight. Make penetrations watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 12 May 2021
Resolution: vessel rep provided evidence of deficiency being corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 April 2021
Resolved
Each distribution panel or switchboard on a towing vessel must be totally enclosed. Starboard forward engine room electrical box was missing a blank on the bottom. Install blank to the satisfaction of the USCG.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 12 May 2021
Resolution: vessel rep provided evidence of deficiency being corrected.