Inspection history · 17
16 February 2024
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7866669
10 February 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7635145
2 January 2023
Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 7615422
8 November 2022
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7596147
10 November 2021
COI Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7349094
5 September 2013
Administration
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4706555
7 June 2010
Administration
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3760261
10 September 2009
Administration · MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3593749
20 July 2006
Uninspected Other · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2719523
10 October 2005
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2511252
18 August 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2466721
26 June 2005
Type not recorded
No type recorded · USCG Heartland District (dpb) · USCG Heartland District (CGD-H) · Activity 2404187
26 June 2005
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2408780
31 July 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2157200
7 July 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2125128
17 May 2004
Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 2070849
2 November 2003
Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 1940631
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 February 2023
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: (a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable.
Engine room bilges were filled with oil, used oil filters, and debris, exhaust lagging is oil soaked and hanging off exhaust piping, various equipment in engine room have heavy accumulation of oil. Vessel to remove oily residue and secure lagging prior to inspection.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 February 2023
Resolved 10 March 2023
Resolution: MI attended and found bilges relatively clean and free of oil.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 February 2023
Resolved
Towing vessels of more than 65 feet in length must carry at least the minimum number of portable fire extinguishers set forth in table 142.230(b)
Fire extinguishers not mounted in brackets and stowed improperly. Vessel to verify appropriate number and type of extinguisher for locations prior to inspection.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 February 2023
Resolved 10 March 2023
Resolution: MI's observed proper amount and type of extinguishers and mounting arrangements
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 10 February 2023
Resolved
Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. Vessel could not produce a Vessel Bridge-to-Bridge Radiotelephony Certificate. Provide a valid Vessel Bridge-to-Bridge Radiotelephony Certificate to USCG MI.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 February 2023
Resolved 10 March 2023
Resolution: MI inspected Bridge-to-bridge radio certificate, sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 February 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. MI’s observed a GFCI breaker in the galley unable to test, a GFCI outlet in the crews head hanging out from the bulkhead, and multiple dead end wiring within the machinery space. Renew/repair all malfunctioning/improperly installed GFCI outlets. Remove or enclose all dead end wiring within a electrical safe enclosure.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 February 2023
Resolved 10 March 2023
Resolution: MI inspected properly installed GFCI outlet
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 February 2023
Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to the Coast Guard upon request. Provide proof of pre-employment testing and proof of enrollment in a random chemical testing program for all employees onboard the vessel.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 February 2023
Resolved 10 March 2023
Resolution: MI was provided with proper pre-emplyment records, random testing records and randomized sampling plan
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 February 2023
Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation.
Vessel had multiple navigation lights extinguished. Vessel to replace lights and make operational prior to inspection. Daytime operation only.
Action required: 705 - Other - as specified
Due 10 February 2023
Resolved 10 March 2023
Resolution: MI observed proper operation of all navigation lights
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 February 2023
Resolved
Inspection and testing. All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months, as prescribed in paragraphs (a)(1) through (8) of this section, or more frequently if otherwise required by the TSMS applicable to the vessel.
Crew had not conducted monthly inspection of fire extinguishers since annual maintenance. Vessel to develop plan to conduct and record monthly inspections.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2023
Resolved 10 March 2023
Resolution: Proper inspection of fire extinguishers was carried out
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 10 February 2023
Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. The navigation assessment must incorporate the requirements of pilothouse resource management of § 140.640, assess operational risks, and anticipate and manage workload demands. At a minimum, this assessment must consider:
Vessel was not able to provide a record of completed navigation assessments. Vessel was able to show they had a navigation assessment in place, but was not being utilized. Vessel to develop plan to conduct and record navigation assessments.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2023
Resolution: Vessel had plan to conduct nav assessment, MI instructed vessel to perform more detailed nav assessment.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 10 February 2023
Resolved
Inspections and tests of lifesaving equipment must be recorded in the TVR or official logbook. Vessel was not familiar with proper testing procedures of the EPIRB and log entries were not made. Conduct proper testing of EPIRB IAW 46 CFR 199.190 and make proper entries.
This is not an all inclusive list as the annual inspection on 10FEB2023 was not completed. Vessel operator to assess compliance with Sub-chapter M and prepare for re-attendance of marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2023
Resolved 20 March 2023
Resolution: Observed proper testing procedure and logging of EPIRB
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 10 February 2023
Resolved
The master of a towing vessel must ensure that drills are conducted and instructions are given to ensure that all crew members are capable of performing the duties expected of them during emergencies. This includes abandoning the vessel, recovering persons from the water, responding to onboard fires and flooding, or responding to other threats to life, property, or the environment. Each drill must, as far as practicable, be conducted as if there was an actual emergency. MI's initiated a man overboard drill as well as a separate fire drill. During the man overboard drill, there was not clear communication between the deckhand and captain. The simulated man overboard was retrieved by his head and neck potentially causing further severe damage if the event had been real. Once onboard, no initial first aid was administered without instruction by the master and even then, the crewmember did not appear willing to perform first aid nor familiar with proper first aid procedures. During the fire drill, no sense of emergency was present from the crew. A fire boundary to the engine room was left open, MI's stopped the drill at that point.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 March 2023
Resolution: Witnessed satisfactory man overboard, engine room fire and abandon ship drills.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 10 February 2023
Resolved
All crewmembers must be provided with health and safety information and training. MI's were provided with training records for health and safety that were not valid due to the training not being conducted annually. Provide all crew with proper health and safety training and document annual training dates in the owner or managing operators records.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 March 2023
Resolution: Observed valid dates of crew health and safety training provided by vessel rep
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 February 2023
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. MI observed a lube oil storage tank with a drain valve that if accidentally left open, would drain the entire contents of the tank into the bilge. Install a locking valve on the drain pipe.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2023
Resolution: Observed new locking valve and plug installed on the engine room lube oil tank
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 February 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. MI observed dead end wiring on the starboard side of the engine room by the ladder. Either remove wiring completely, or dead end the wiring within an enclosure to the satisfaction of the MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2023
Resolution: Vessel rep removed dead end wiring
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 February 2023
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. This may be accomplished by an installed detection system, or by using individual battery-operated detectors meeting UL 217 (incorporated by reference, see § 136.112 of this subchapter). Detection systems or individual detectors must be kept operational at all times when the crew is onboard the towing vessel. Vessel found with inoperable smoke detectors and detectors not meeting UL 217. Replace detectors and ensure all operable.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2023
Resolution: Observed installation of new UL 217 approved smoke detectors
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 February 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Batteries were found in enclosed containers but not protected against shifting. Install a means to prevent shifting of batteries within enclosure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2023
Resolution: Observed properly stored and secured batteries
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 10 February 2023
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. Port side watertight door leading to galley found with degraded gasket. Replace gasket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2023
Resolution: Observed new gasket installed on the port side door
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 February 2023
Resolved
The following systems must be equipped with gauges at the machinery location:(1) Main engine lubricating oil pressure and main engine RPM;(c)(3)Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM. Install rpm gauges on all machinery.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 March 2023
Resolution: Vessel rep provided video attestation of proper operation of both generator tachometers.