Records from 1999 to 2024. Most recent: inspection, 22 January 2024.
Documentation record
Registered dimensions (L × B × D)50.9 ft × 19.0 ft × 8.4 ft
Registered tonnagegross 56 / net 38
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · COOS BAY, OR, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKETCHIKAN, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 31 July 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it56 - Regulatory (Subpart C or D), Gross Ton
38 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 14
22 January 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7858839
24 May 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7696043
11 May 2022
Initial Certification · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7450079
30 June 2020
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7029312
10 July 2018
Industry Initiated Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6474218
31 August 2012
Industry Initiated Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4427405
17 May 2012
Administration
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 4314290
8 December 2008
Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3376353
4 November 2008
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3358412
9 November 2007
Uninspected Other
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3096002
12 May 2006
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2693281
28 November 2000
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 47630
11 June 1999
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 663691
17 May 1999
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 80903
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 May 2023
Resolved
Decks and bulkheads designed to be watertight or weathertight must be maintained in that condition. Vessel Port Captain reported that during the TSMS external audit, the vessel was discovered to have holes affecting the watertight integrity of the engine room, both forward and aft. Temporary repairs are permitted until the next drydock (due April 2024). Make permanent repairs prior to credit drydock. 46 CFR 140.610(f)
Action required: 705 - Other - as specified
Due 30 April 2024
Resolved 22 January 2024
Resolution: Received ABS report attesting to permanent repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 May 2023
Resolved
Machinery systems must be maintained to provide for safe operation of the towing vessel and safety of persons onboard. Vessel Port Captain reported that during the TSMS external audit, both main engines were observed to be leaking oil into the bilge. Vessel representative is required to submit an engine overhaul plan/proposal to the Coast Guard, as per NC Machinery guidance, to fix oil seepage from main engines, within 30 days. 46 CFR 143.205(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 30 January 2024
Resolution: Overhaul complete. Received technician letter and ABS finding detail report.
Engineering › Fuel Oil Service System › Valve, Control
Issued 9 November 2007
Resolved
Vessel must be equipped with remote operated f/o service valves in the machinery space. Valves must be actuated from outside the space as cited in 46 CFR 27.207
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 30 August 2012
Resolution: Tested f/o service valves located outside of ER. Labeled and functioning properly.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 9 November 2007
Resolved
Original C.O.D must be maintained onboard the vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 31 August 2012
Resolution: verified valid COD on board.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 9 November 2007
Resolved
Vessel must be equipped with a fire detection system for the machinery space as cited in 46 CFR 27.203
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 30 August 2012
Resolution: Verified fire detection system functioniong properly in ER.
Communications › Alarms/Indicators › General Alarm
Issued 9 November 2007
Resolved
Vessel must be equipped with a General Alarm or equivalent as cited in 46 CFR 27.201
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 30 August 2012
Resolution: Tested General Alarm. all sat.
Fire Fighting › Fire Pumps › Arrangement
Issued 9 November 2007
Resolved
Vessel must be equipped with an installed fire pump or portable pump meeting all requirements as cited in 46 CFR 27.301
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 31 August 2012
Resolution: Verified operation of portable fire pump at 60psi/80gpm. Operators use antifreeze in primer tank on pump to prevent from freezing in winter and for better lubrication.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 9 November 2007
Resolved
Vessel must be equipped with a fixed fire extinguishing system or a B-V extinguisher as cited in 46 CFR 27.303
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 31 August 2012
Resolution: Semi portable B-V mounted in forward berthing are due to limited space available on vessel.