Records from 2001 to 2021. Most recent: inspection, 14 October 2021.
Documentation record
Registered dimensions (L × B × D)58.0 ft × 16.1 ft × 5.6 ft
Registered tonnagegross 47 / net 32
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLEE TOWING CO INC · ORANGE TX, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it47 - Regulatory (Subpart C or D), Gross Ton
32 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 7
14 October 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7337756
27 July 2021
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7269148
11 March 2020
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6924923
7 October 2014
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 5001672
8 May 2013
Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4586614
3 March 2009
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3427043
6 February 2001
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1522359
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 July 2021
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the associated fleet that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 October 2021
Resolved 14 October 2021
Resolution: Vessel changed to laid up status per owners request.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 March 2020
No resolution recorded
All fire detection systems and portable fire
extinguishers must be serviced every 12 months. The fire
detection panel was last serviced in 2013. Fire
extinguisher had not been serviced since 2018. Fire
detection panel must be serviced by certified servicing
shop, provide proof of P.E. system installation letter 46CFR142.240(a)
Action required: 30 - Ship detained
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 March 2020
Resolved
All bilges and void spaces are kept free from
accumulation of combustible and flammable materials and
liquids insofar as practicable. Identified excessive
amounts of oil throughout the engine room bilge, up to 4
inches, beneath the port & stbd engines & generators,
fuel manifold, & the other portions of the engine room,
posing an imminent hazard to the crew & environment, a
serious substandard condition not being pro-actively
managed. Remove excess oily-water from engine room
bilges. 46CFR142.220(a)
Action required: 30 - Ship detained
Resolved 13 March 2020
Resolution: oil removed, bigle cleaned, on 13MAR2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 March 2020
No resolution recorded
Machinery and electrical systems must be designed and
maintained to provide for safe operation of the towing
vessel and safety of persons onboard under normal and
emergency conditions. SSDG Port&STBD side had excessive
oil build up on the windings. Clean windings of SSDG. 46CFR143.205(a)
Action required: 30 - Ship detained
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 March 2020
No resolution recorded
Each towing vessel must have either a self priming power
driven, fixed fire pump, a fire main, and hoses and
nozzels in accordance with paragraphs (a) through (d) of
this section. The fire pump was inoperable and would not
start with remote switch or local control. Replace or
repair fire pump to proper operation and pressure. 46CFR142.325
Action required: 30 - Ship detained
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 11 March 2020
No resolution recorded
No person may operate any vessel equipped with installed
toilet facilities unless it is equipped with an operable
Type 1,2,or 3 MSD. Vessel crew informed us that the
vessel MSD had been inoperable and still using the
toilet facilities. 33CFR159.7(a)
Action required: 30 - Ship detained
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 March 2020
No resolution recorded
To stop the flow of fuel in line in the event of a fire
or break in the fuel line, a remote fuel shutf-off valve
must be fitted on any fuel line that supplies fuel
directly to a propulsion engine or generator prime
mover. Witnessed the fuel valve with multiple zip ties
holding the valve open. 46CFR143.260(a)
a)Remove zip ties and prove proper operation of fuel
valve.
b)Ensure 2 valves directly aft of the fuel tank have
remote means of closure, within 14 days.
Action required: 30 - Ship detained
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 March 2020
No resolution recorded
Smoke detection in berthing spaces. Vessel had no smoke
detection located in the berthing space. Install proper
smoke detector in berthing space, crew not authorized to
use bunk spaces until provided. 46CFR142.330(b)
Action required: 30 - Ship detained
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 11 March 2020
No resolution recorded
Decks and bulkheads designed to be watertight or
weathertight must be maintained in that condition.
Inspector found the door going into the galley missing a
gasket and found the aft engine room door unable to
close to a weathertight/watertight condition. 46CFR140.610(f)
Action required: 60 - Rectify deficiencies prior to movement
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 11 March 2020
No resolution recorded
Rails or equivalent protection must be installed near
the periphery of all decks accessible to crew. Rails or
equivalent protection must be installed near
the periphery of all decks accessible to crew.
Equivalent protection may include lifelines, wire rope,
chains, and bulwarks that provide strength and support
equivalent to fixed rails. In areas where space
limitations make deck rails impractical, such as at
narrow catwalks in way of deckhouse sides, hand grabs
may be substituted. No railing or hand grabs alongside
the side deck superstructure, Bulkwarks were roughly
18-24 inches high, creating an unsafe condition for crew
members to fall overboard. Action 705: to be fixed by in
2 weeks. 46CFR144.800(a)
Action required: 16 - Rectify deficiencies w/in 14 days