MAURY USCG vessel records Sign in
← All vessels

TRINITY I

TRINITY I is a 1980 offshore supply vessel. The Coast Guard has recorded 55 inspections since 1989, most recently in December 2015, along with 62 deficiencies — 1 with no resolution recorded — and 1 casualty investigation in 2010.

Records from 1989 to 2015. Most recent: inspection, 15 December 2015.

Built
1980
Last inspected
15 December 2015
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8767408 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDF3138
191566
Flag
UNITED STATES
366817930, 367436350 (licence lapsed)
Maury page id
psix-191566

Inspections, by type

…with no type recorded9
Years with a record 25 calendar years (1989–2015)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)76.0 ft × 54.0 ft × 7.7 ft
Registered tonnagegross 191 / net 130
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLUE STREAK ENTERPRISE · CHALMETTE, LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it191 - Regulatory (Subpart C or D), Gross Ton
130 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF3138MMSI 367436350 · expired · compulsorily equipped · granted 13 January 2010, cancelled 14 March 2020
WDA5235MMSI 366817930 · cancelled · compulsorily equipped · granted 6 July 2001, cancelled 25 November 2009 · licensed under a name not among this hull’s recorded names (not shown)
WCV8458MMSI not assigned · expired · compulsorily equipped · granted 25 November 1998, cancelled 1 April 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

HELM EXPRESS Offshore Supply Vessel · MISLE 55267 · 22 June 2000 · activity 125427

Inspection history · 55

15 December 2015 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5781896
23 July 2015 Administrative Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5208578
31 January 2012 Annual Inspection · Deficiency Check · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4235627
5 December 2011 Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4202179
8 December 2010 MTSA/ISPS Verification · Ballast Water Examination · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3906621
19 November 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3894847
21 December 2009 Ballast Water Examination · Administrative Inspection · Examination of Repairs · Internal Structural Exam · Annual Inspection · MTSA Verification · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3653587
19 November 2008 Ballast Water Examination · Administrative Inspection · Re-Inspection · MTSA Verification · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3377570
4 March 2008 Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3158225
18 October 2007 Re-Inspection · Internal Structural Exam · MTSA Verification · Hull Examination · Examination of Repairs · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3086253
7 August 2006 COI Inspection · MTSA Verification · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2738554
26 June 2006 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2691814
25 May 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2658882
7 November 2005 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2529840
20 October 2005 Ballast Water Examination · MTSA Verification · Re-Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2518486
9 September 2005 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2492227
24 August 2004 MTSA Verification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2174473
25 November 2003 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1954491
18 September 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1907605
19 July 2002 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1650946
27 August 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1072751
12 July 2001 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1362348
6 October 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410423
22 June 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 125427
27 April 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 770610
30 March 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 202065
1 March 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 766725
2 February 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 202068
1 October 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1350447
27 July 1999 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1411940
2 December 1998 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1402746
22 September 1997 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438609
9 August 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1445111
10 July 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396327
29 August 1994 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358507
2 November 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 667896
28 October 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 22109
2 July 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436779
22 March 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 834590
13 August 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 957716
23 June 1992 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354174
8 January 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 950633
9 December 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 944402
4 December 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1251560
15 November 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1006206
12 July 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1255491
26 February 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 921308
20 December 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1220190
3 October 1990 Re-Inspection · Inclining Experiment · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1211737
7 September 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1224543
16 July 1990 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1220512
20 December 1989 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1214373
8 December 1989 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1228031
11 September 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1208113
12 July 1989 Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1348061

Deficiency record · 62

Fire Fighting › Portable Foam Applicators › General
Issued 31 August 2015 No resolution recorded
Vessel did not have MPT firefighting equipment to carry DOT and MPTs.
Action required: 701 - Prior to carriage of passengers/cargo
Electrical › Electric Supply System (service) › Cable
Issued 31 January 2012 Resolved
Remove or repair electrical wiring in walk in cooler.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2012
Communications › Alarms/Indicators › Bilge Alarm
Issued 31 January 2012 Resolved
Repair and prove operational audiable bilge alarm in port engine room and rudder compartment
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2012
Navigation › Piloting/Steering › Compass Deviation Table
Issued 31 January 2012 Resolved
provide a valid compass deviation table
Action required: 705 - Other - as specified
Due 29 February 2012
Resolved 3 February 2012
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 31 January 2012 Resolved
Adjust steering gear indicator to reflect correft degree of turn
Action required: 705 - Other - as specified
Resolved 3 February 2012
Engineering › Steering Gear System › Power Unit
Issued 31 January 2012 Resolved
Steering pump light inoperable at pilot house station, repair and prove operational
Action required: 705 - Other - as specified
Resolved 3 February 2012
Engineering › Lubricating Oil Storage/Transfer System › Flange
Issued 31 January 2012 Resolved
Repair leaking hyd line in starboard engine room adjacent to steering system
Action required: 705 - Other - as specified
Resolved 3 February 2012
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 31 January 2012 Resolved
Label motor controls for bilge pump in Engine room
Action required: 705 - Other - as specified
Resolved 3 February 2012
Engineering › Bilge Water Management System › Piping
Issued 31 January 2012 Resolved
Bilge and ballast system has valve controls that penetrate the centerline bulkhead. Repack valve stems to ensure water tightness of the sapece
Action required: 705 - Other - as specified
Resolved 3 February 2012
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 31 January 2012 Resolved
Label number of lifejackets stowed in each location
Action required: 705 - Other - as specified
Resolved 3 February 2012
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 31 January 2012 Resolved
Lube oil containment main deck center at house missing scupper plug.
Action required: 705 - Other - as specified
Resolved 3 February 2012
Fire Fighting › Grease Extraction Hood › General
Issued 31 January 2012 Resolved
Clean grease extraction hood in galley
Action required: 705 - Other - as specified
Resolved 3 February 2012
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 31 January 2012 Resolved
Lube oil vent missing flame screen
Action required: 705 - Other - as specified
Resolved 3 February 2012
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 31 January 2012 Resolved
Emergency lights in Starboard engine room and Port deck embarkation area in operable - reapir and prove operational
Action required: 705 - Other - as specified
Resolved 3 February 2012
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 31 January 2012 Resolved
Vent closures on main deck for engine room missing appropiate length bolts to properly secure in case of fire - replace/repair and prove operational to USCG.
Action required: 705 - Other - as specified
Resolved 3 February 2012
Construction/Loadline › Hull › Transverse Frame
Issued 31 January 2012 Resolved
Fwd engine room bulkhead in port engine room cable piping run above air compressor not watertight - repack/seal
Action required: 705 - Other - as specified
Resolved 3 February 2012
Construction/Loadline › Structures › Ventilators
Issued 31 January 2012 Resolved
Support brakcets for engine exhausts in engine room broken (cracked welds) - repair
Action required: 705 - Other - as specified
Resolved 3 February 2012
Stability › Watertight Integrity › General
Issued 31 January 2012 Resolved
Watertight door on main deck port side needs adjustment for proper fit/seal.
Action required: 705 - Other - as specified
Resolved 3 February 2012
Lifesaving › Rocket Parachute Flares › General
Issued 31 January 2012 Resolved
Provide a distress signals box, that is watertight and able to float.
Action required: 705 - Other - as specified
Resolved 3 February 2012
Electrical › Lighting (emergency) › Lighting Fixture
Issued 31 January 2012 Resolved
Provide appropiate lighting for an emergency to provide illumiation to the embarkation startion, iincluddibng the use of outside walk ways
Action required: 705 - Other - as specified
Resolved 3 February 2012
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 December 2010 Resolved
Repair emergency lighting in stbd engine room
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 15 December 2010
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 December 2010 Resolved
Install emergency lighting fixtures to illuminate liferaft launching areas P & S.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 15 December 2010
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 8 December 2010 Resolved
Install GFI outlets in heads throughout vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 15 December 2010
Electrical › Electrical Distribution System (service) › Cable
Issued 8 December 2010 Resolved
Correct faulty wiring at outlet box, port engine room IWO Geerator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 15 December 2010
Electrical › Electrical Distribution System (service) › Cable
Issued 8 December 2010 Resolved
Remove unapproved extension cord and outlet box from "company man" stateroom.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 15 December 2010
Accommodation/Occupational Safety › Potable Water System › General
Issued 8 December 2010 Resolved
Properly secure fresh water oump to foundation with bolts.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 15 December 2010
Communications › Audible Communications › Bell
Issued 8 December 2010 Resolved
Paint general alarm bells red and properly lable as general alarm.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 15 December 2010
Communications › Alarms/Indicators › General Alarm
Issued 8 December 2010 Resolved
Properly secure electrical box for general alarm strobe light in port engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 15 December 2010
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 8 December 2010 Resolved
Provide proper bracket for portable fire extinguisher, 01 deck lounge.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 15 December 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 December 2010 Resolved
Provide required "O" ring gaskets in all navigation light fixtures.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 15 December 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 December 2010 Resolved
Paint navigation light side screens black.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 15 December 2010
Lifesaving › Inflatable Liferafts › Servicing
Issued 8 December 2010 Resolved
Provide liferaft servicing certificates onboard for all inflatable liferafts onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 15 December 2010
Communications › Radio Communications › Emergency Source of Power
Issued 8 December 2010 Resolved
Provide backup power source for SSB radio.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 15 December 2010
Deck/Cargo › Cargo Transfer (solid) › General
Issued 8 December 2010 Resolved
Provide crane testing & examination reports IAW API standards. Also provide crane logbook onboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 15 December 2010
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 20 October 2005 Resolved
Provide ballast water management plan on board vessel.
Action required: 705 - Other - as specified
Due 20 November 2005
Resolved 7 August 2006
Resolution: Vsl provided ballast water management plan.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 20 October 2005 Resolved
Master to demonstrate ability to perform stability calc's and and approved KG curve to staisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 20 November 2005
Resolved 7 November 2005
Resolution: Provided.
Engineering › Diesel Engine (propulsion-direct drive) › Bedplate
Issued 18 September 2003 Resolved
Provide automation test procedures for approval.
Action required: 705 - Other - as specified
Due 22 October 2003
Resolved 20 October 2005
Resolution: Provided, stamped.
Construction/Loadline › Hull › Bracket
Issued 18 September 2003 Resolved
Replace/renew, aft leg tower support due to wastage. to be completed at next drydock.
Action required: 705 - Other - as specified
Due 27 July 2004
Resolved 20 October 2005
Resolution: Aft leg tower supports inspected, none found to be wasted, supports may have been renewed at previous drydock.
Navigation
Issued 12 July 2001 Resolved
PROPERLY INSTALL MASTHEAD LIGHTS.
Condition: Unknown
Due 12 July 2001
Resolved 12 July 2001
Electrical
Issued 12 July 2001 Resolved
PROPERLY INSTALL WIRING AT TOP OF LADDER WELL LEADING TO BRIDGE.
Condition: Unknown
Due 12 July 2001
Resolved 12 July 2001
Electrical
Issued 12 July 2001 Resolved
PROPERLY SECURE WIRING ON BRIDGE.
Condition: Unknown
Due 12 July 2001
Resolved 12 July 2001
Electrical
Issued 12 July 2001 Resolved
PROVE PROPER OPERATION OF TACHOMETERS IN MACHINERY SPACES FOR BOTH SHIP SERVICE GENERATORS.
Condition: Unknown
Due 12 July 2001
Resolved 12 July 2001
Electrical
Issued 12 July 2001 Resolved
PROVIDE AND INSTALL PROPER PANEL BOARD DIRECTORIES IAW 46 CFR 111.40-11 ON ALL ELECTRICAL DISTRIBUTION PANELS.
Condition: Unknown
Due 12 July 2001
Resolved 12 July 2001
Construction/Loadline
Issued 12 July 2001 Resolved
REPAIR HATCH COVER POST FWD HOUSE ON STBD SIDE PUMP WATER FROM VOID.
Condition: Unknown
Due 12 July 2001
Resolved 12 July 2001
Engineering
Issued 12 July 2001 Resolved
PROVE PROPER OPERATION OF MAIN ENGINE OVERSPEED TRIPS, LOW LUBE OIL AND HIGH JACKET WATER TEMP. ALARMS.
Condition: Unknown
Due 12 August 2001
Resolved 18 September 2003
Resolution: All inspections/tests conducted during RIN on 09/18/2003.
Navigation
Issued 12 July 2001 Resolved
PROVE PROPER OPERATION OF FATHOMETER.
Condition: Unknown
Due 12 July 2001
Resolved 12 July 2001
Lifesaving
Issued 27 July 1999 Resolved
Demonstrate compliance with the 8th U.S. Coast Guard District's policy "Rescue Boat Requirements on Offshore Supply Vessels" dated 12NOV98 to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Lifesaving
Issued 2 December 1998 Resolved
PROVIDE PROPER RELIEF VALVE FOR AIR RECEIVER IN PORT SIDE ENGINE ROOM.
Condition: Unknown
Due 2 December 1998
Resolved 2 December 1998
Lifesaving
Issued 2 December 1998 Resolved
PROVIDE PRESSURE RELIEF VALVE FOR HOT WATER HEATER.
Condition: Unknown
Due 2 December 1998
Resolved 2 December 1998
Lifesaving
Issued 2 December 1998 Resolved
MAKE PROPER REPAIRS TO SANITARY DRAIN ON PORT SIDE FORWARD OF HOUSE.
Condition: Unknown
Due 2 December 1998
Resolved 2 December 1998
Lifesaving
Issued 23 June 1992 Resolved
PROVIDE ON BOARD A LEVEL INDICATING DEVICE.
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Documentation
Issued 11 September 1989 Resolved
PROVIDE LOADLINE CERTIFICATE IAW 46 CFR 42.03.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Documentation
Issued 12 July 1989 Resolved
SUBMIT PLANS AS REQUIRED BY 46 CFR 91.55 & 46 CFR PART 107 SUBPART C AS APPLICABLE TO THE [name withheld], LA FOR FORWARDING TO THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, DC FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Lifesaving
Issued 12 July 1989 Resolved
PROVIDE RESCUE BOAT OR SUBMIT AN ALTERNATE PROPOSAL FOR APPROVAL.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Accommodation/Occupational Safety
Issued 12 July 1989 Resolved
INSTALL A U.S. COAST GUARD APPROVED MARINE SANITATION DEVICE IN ACCORDANCE WITH 33 CFR 159.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Electrical
Issued 12 July 1989 Resolved
INSTALL BANDING ON ELECTRICAL WIRING THRU OUT VESSEL IAW IEEE 45.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Engineering
Issued 12 July 1989 Resolved
INSTALL AND DEMONSTRATE PROPER OPERATION OF JACKING SYSTEM FAILURE ALARMS.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Fire Fighting
Issued 12 July 1989 Resolved
REPAIR OR REPLACE VESSELS FIRE PUMPS TO MEET THE REQUIREMENTS OF 46 CFR 95.10(C)&(D).
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Electrical
Issued 12 July 1989 Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF OVERSPEED TRIP ON VESSELS STBD GENERATOR.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Documentation
Issued 12 July 1989 Resolved
SUBMIT AN OPERATING MANUAL AS REQUIRED BY NVIC 8-81 CHANGE 1 TO THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON DC FOR REVIEW AND APPROVAL SUBMIT MANUAL VIA [name withheld], LA.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Documentation
Issued 12 July 1989 Resolved
SUBMIT STABILITY CALCULATIONS TO THE U.S. COAST GUARD MARINE SAFETY CENTER FOR REVIEW AND APPROVAL AS REQUIRED BY 46 CFR SUBCHAPTER S .
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Documentation
Issued 12 July 1989 Resolved
PROVIDE APPROVED PLANS TO COGNIZANT OCMI.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989

Casualty record · 1

6 April 2010Routine · role: Involved in a Marine Casualty · 1 injured · activity 3710761
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.