Records from 1984 to 2007. Most recent: inspection, 13 December 2007.
Inspection history · 28
13 December 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3114815
17 January 2007
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2857504
23 March 2006
Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2608330
1 December 2005
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2535388
1 September 2004
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2183086
18 June 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2102821
24 May 2004
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2076978
12 February 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2005329
4 June 2002
Hull Examination · Internal Structural Exam · Periodic Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1630088
20 September 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1420590
11 May 2001
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 769386
4 April 2001
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 191496
2 October 2000
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 823289
23 August 2000
Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1395526
22 June 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 125427
4 December 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 6681
27 August 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402946
1 April 1999
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1125906
28 August 1998
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466555
5 March 1992
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1316354
18 December 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 901894
7 December 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 910198
31 August 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1038959
8 January 1988
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015195
2 November 1987
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1328951
25 October 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1334837
16 September 1985
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992330
4 October 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 975885
Engineering › Diesel Engine (propulsion-reduction gear) › Distributor (air start)
Issued 1 December 2005
Resolved
The port main diesel engine could not be started for inspection. The shaft tachometer needs to be checked on the bridge along with the remote engine stop.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 November 2006
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 1 December 2005
Resolved
The vessel is capable of taking on saltwater ballast and did not have a ballast water management on board.
Due 2 January 2006
Resolved 20 November 2006
Stability › Watertight Integrity › General
Issued 1 September 2004
Resolved
Provide missing J bolts in crew accomodations,
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 September 2004
Resolution: Completed per vessel rep.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 1 September 2004
Resolved
Provide donning instructions for wheel house.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 September 2004
Resolution: Rec''d copy of donning instructions from vessel rep.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 1 September 2004
Resolved
Swing compass, provide legible copy of compass deviation card.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 September 2004
Resolution: Compass swung, compass deviation card provided.
Lifesaving › Lifebuoys › Serviceable
Issued 1 September 2004
Resolved
Replace Retro Reflective tape where covered by paint.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 September 2004
Resolution: Verified by vessel rep.
Lifesaving › Lifebuoys › Stowage
Issued 1 September 2004
Resolved
Restowe aft deck life ring with line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 September 2004
Resolution: verified by vessel rep.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 1 September 2004
Resolved
Store E/R life jacket in clear plastic bag vice black plastic bag to make more visible.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 September 2004
Resolution: Verified by vessel rep.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 1 September 2004
Resolved
Install cover on dry bulk air compressor PTO clutch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 September 2004
Resolution: Verified by vessel rep.
Engineering › Pressure Vessel › Relief Valve
Issued 1 September 2004
Resolved
Swap out relief valves between air rec'r and air rec'r supply line. (supply line popped @ 175 psi air rec'r @ 185.)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 September 2004
Resolution: Verified by vessel rep.
Engineering › Freshwater System (jacketwater cooling) › Vent
Issued 1 September 2004
Resolved
Install plug in keel cooler vent line valve.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 September 2004
Resolution: Verified by vessel rep.
Construction/Loadline › Hull
Issued 12 February 2004
Resolved
RENEW BOTTOM ANGLES UNDER BOTH PORT AND STARBOARD SHAFTS. LEGACY COMPONENT DESC: Stiffener
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2004
Resolved 12 February 2004
Engineering › Reduction Gearing/Clutches
Issued 12 February 2004
Resolved
RENEW ONE PORT REDUCTION GEAR FLEXIBLE HOSE. LEGACY COMPONENT DESC: HOSE
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2004
Resolved 12 February 2004
Construction/Loadline › Structures › Door
Issued 12 February 2004
Resolved
ADJUST DOGS ON RUDDER ROOM AND ENGINE ROOM WATER TIGHT DOORS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2004
Resolved 12 February 2004
Engineering › Fuel Oil Service System
Issued 12 February 2004
Resolved
PROVIDE AND INSTALL VALVE HANDLE FOR STARBOARD GENERATOR FUEL OIL SUPPLY VALVE. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2004
Resolved 12 February 2004
Engineering › Fuel Oil Service System › Hose
Issued 12 February 2004
Resolved
PROVIDE AND INSTALL CHAFFING GEAR ON ENGINE ROOM FLEXIBLE HOSES.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 February 2004
Resolved 12 February 2004
Navigation › Piloting/Steering
Issued 12 February 2004
Resolved
PROVIDE EMERGENCY STEERING INSTRUCTIONS AT OPERATING STATION AND ENGINE ROOM STATION. LEGACY COMPONENT DESC: EMERGENCY STEERING INSTRUCTIONS
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 February 2004
Resolved 12 February 2004
Deck/Cargo › Cargo Stowage
Issued 12 February 2004
Resolved
PROVIDE AND INSTALL FLAME SCREEN ON CENTER STARBOARD LUBE OIL TANK VENT PIPE. LEGACY COMPONENT DESC: VENT PIPE
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 February 2004
Resolved 12 February 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 12 February 2004
Resolved
PROVIDE AND POST LIQUID MUD TRANSFER PROCEDURES. LEGACY COMPONENT DESC: TRANSFER PROCEDURES
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2004
Resolved 12 February 2004
Communications › Alarms/Indicators
Issued 30 May 2002
Resolved
High temperature sensors not operating properly for starboard main engine gear oil, port main engine oil and jacket water, and mud pump. 35 degree F deviation between sensors/alarms and temperature testing gage/thermometer.
Action required: 705 - Other - as specified
Due 4 June 2002
Resolved 4 June 2002
Resolution: Sensors re-calibrated. Sensors/alarms re-tested satisfactorily.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 May 2002
Resolved
Upper range light on mast was inoperable.
Action required: 705 - Other - as specified
Due 4 June 2002
Resolved 4 June 2002
Resolution: Electrical connection repaired to upper range light on mast.
Stability › Watertight Integrity
Issued 23 May 2002
Resolved
Electrical penetrations through the watertight bulkhead in engine room were not tight. LEGACY COMPONENT DESC: Electrical penetrations
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 June 2002
Resolved 4 June 2002
Resolution: Electrical penetrations through the watertight bulhead in engine room were tightened and properly sealed.
Stability › Watertight Integrity
Issued 23 May 2002
Resolved
Port and starboard watertight doors to the engine room from the main deck did not close properly. LEGACY COMPONENT DESC: Doors
Action required: 705 - Other - as specified
Due 4 June 2002
Resolved 4 June 2002
Resolution: New watertight doors installed and chalk tested satisfactorily.
Construction/Loadline › Markings
Issued 23 May 2002
Resolved
Deck reference mark not indicated on hull. LEGACY COMPONENT DESC: Deck reference
Action required: 705 - Other - as specified
Due 4 June 2002
Resolved 4 June 2002
Resolution: Deck reference mark properly painted on hull.
Lifesaving › Lifebuoys
Issued 23 May 2002
Resolved
Retro reflective tape on both bridge wing life buoys was peeling off and worn. LEGACY COMPONENT DESC: Retro reflective tape
Action required: 705 - Other - as specified
Due 4 June 2002
Resolved 4 June 2002
Resolution: Both bridge wing life buoys were replaced.
Pollution Prevention/Response › Response Equipment
Issued 23 May 2002
Resolved
No pollution discharge equipment on board.
Action required: 705 - Other - as specified
Due 4 June 2002
Resolved 4 June 2002
Resolution: Proper pollution discharge equipment kit placed on vessel.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 23 May 2002
Resolved
Fuel filter containment bowls on main engines did not have drain plugs.
Action required: 705 - Other - as specified
Due 4 June 2002
Resolved 4 June 2002
Resolution: Drain plugs installed on fuel filter containment bowls.
Construction/Loadline › Structures
Issued 21 May 2002
Resolved
Crop and renew #1 starboard ballast tank transverse horizontal stiffener on aft bulkhead. LEGACY COMPONENT DESC: Transverse stiffener
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 June 2002
Resolved 4 June 2002
Resolution: Transverse horizontal stiffener on aft bulkhead in #1 starboard ballast tank was cropped and renewed.
Construction/Loadline › Structures
Issued 21 May 2002
Resolved
Watertight bulkhead and vertical stiffeners in way of the #1 and #2 starboard ballast tank were bowed and fractured. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 June 2002
Resolved 4 June 2002
Resolution: Vertical stiffeners were removed; bulkhead was straightened; fractures were drill stopped, gouged, and welded; and vertical stiffeners were renewed. #1 ballast tank hydrostatic tested satisfactorily.
Construction/Loadline › Structures
Issued 21 May 2002
Resolved
Crop and renew wasted flanges on deep frames in way of machinery passage way. LEGACY COMPONENT DESC: Deep frames
Action required: 705 - Other - as specified
Due 4 June 2002
Resolved 4 June 2002
Resolution: Flanges on deep frames in way of machinery passage way were cropped and renewed.
Construction/Loadline › Structures
Issued 21 May 2002
Resolved
Crop and renew foundation for the fire pump. LEGACY COMPONENT DESC: Foundation
Action required: 705 - Other - as specified
Due 4 June 2002
Resolved 4 June 2002
Resolution: Foundation for the fire pump was cropped and renewed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 21 May 2002
Resolved
Crop and renew wasted section of liquid mud piping in #2 port liquid mud tank.
Action required: 705 - Other - as specified
Due 4 June 2002
Resolved 4 June 2002
Resolution: Wasted section of liquid mud piping in #2 port liquid mud tank cropped and renewed.
Construction/Loadline
Issued 23 August 2000
Resolved
Restencil ballast tank, fuel tank, liquid mud and potable water tanks with correct contents information.
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Electrical
Issued 23 August 2000
Resolved
Provide updated circuit panel cards for all electrical panels throughout vessel IAW 46 CFR 111.40-11.
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Fire Fighting
Issued 23 August 2000
Resolved
Update vessel's Fire Control Plan IAW IMO Resolution and submit to MSO Mobile Inspections for verification and approval.
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Lifesaving
Issued 23 August 2000
Resolved
Stencil "Lifebuoy" locations or provide IMO symbols for each lifebuoy.
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Engineering
Issued 23 August 2000
Resolved
Prove main engine shaft direction indicators at control station.
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Accommodation/Occupational Safety
Issued 23 August 2000
Resolved
Replace dryer hose with metalic hose.
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Lifesaving
Issued 23 August 2000
Resolved
Provide EPIRB registration by NOAA.
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Construction/Loadline
Issued 23 August 2000
Resolved
Crop and renew knife edge on starboard side watertight door to engine room.
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Engineering
Issued 23 August 2000
Resolved
Update the vessels machinery Automation Procedures IAW NVIC 1-78 Change 1, and submit procedures to MSO Mobile Inspections for verification and approval. Provide Technical publications to the attending CG marine inspector during verification.
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Construction/Loadline
Issued 23 August 2000
Resolved
Adjust watertight doors to main deck lockers, and prove to attending marineinspector.
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Electrical
Issued 23 August 2000
Resolved
Remove paint from grab rail on switch board in engine room.
Condition: Unknown
Due 23 September 2000
Resolved 6 September 2000
Navigation
Issued 23 August 2000
Resolved
Prove proper operation of rudder angle indicator in the engine room.
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Lifesaving
Issued 23 August 2000
Resolved
Replace retro-reflective tape on lifebuoy on 01 deck aft of house.
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Fire Fighting
Issued 28 August 1998
Resolved
INSTALL USCG APPROVE FIRE DETECTION PANEL PER MSC LTR DTD 24DEC98 _x001C_ S/N E2-9804515, AND 46CFR 161.002.
Condition: Unknown
Due 28 August 1998
Resolved 28 August 1998
Engineering
Issued 28 August 1998
Resolved
SUBMIT NAVIC 1-78 AUTOMATION PACKAGE PLANS TO MARINE SAFETY CENTER FOR APPROVAL.
Condition: Unknown
Due 30 October 1998
Resolved 5 January 1999
Engineering
Issued 28 August 1998
Resolved
REVISE AUTOMATION TEST PROCEDURE IN ACCORDANCE WITH NAVIC 1-78 AND MORGAN CITY CID MEMO # 30.
Condition: Unknown
Due 28 August 1998
Resolved 28 August 1998
Lifesaving
Issued 8 January 1988
Resolved
OBTAIN USCG APPROVAL OF LIFESAVING AND FIRE CONTROL PLAN. (NOTE: RECEIPT OF A COPY OF THIS PLAN IS ACKNOWLEDGED; CURRENT PLAN IS TO REMAIN POSTED PENDING REVIEW BY USCG.) REF: 46 CFR 97.36-1
Condition: Unknown
Due 8 January 1988
Resolved 8 January 1988
Documentation
Issued 8 January 1988
Resolved
PROVIDE THE FOLLOWING PUBLICATIONS ON BOARD THE VESSEL: (1) INTERNATIONAL RULES OF THE ROAD; (2) LOADLINE REGULATIONS; (3) SAILING DIRECTIONS. (46CFR 97.05-5)
Condition: Unknown
Due 8 January 1988
Resolved 8 January 1988
Documentation
Issued 8 January 1988
Resolved
PROVIDE COPY OF CURRENT LOADLINE CERTIFICATE TO [name withheld]. (46 CFR SUBCHAPTER E)
Condition: Unknown
Due 8 January 1988
Resolved 8 January 1988
Documentation
Issued 8 January 1988
Resolved
0BTAIN AND AFFIX RENEWAL STICKER F0R CERTIFICATE OF D0CUMENTATI0N T0 INDICATE VALIDITY OF SUBJECT DOCUMENTATION. (46 CFR 67.45-5)
Condition: Unknown
Due 8 January 1988
Resolved 8 January 1988
Construction/Loadline
Issued 8 January 1988
Resolved
SUBMIT FOR APPROVAL PLANS DETAILING ALTERATIONS TO BOW OF VESSEL. THESE PLANS ARE TO BE SUBMITTED TO USCG MARINE SAFETY CENTER, 2100 ST. S. W., WASHINGTON DC. VESSEL NOT TO BE ENGAGED IN "PUSHING" OPERATIONS PENDING PLAN REVIEW.
Condition: Unknown
Due 8 January 1988
Resolved 8 January 1988
Engineering
Issued 8 January 1988
Resolved
DEMONSTRATE PROPER OPERATION OF MAIN MAIN ENGINE ALARMS, TRIPS, AND AUTOMATION DEVICES. 46 CFR 58
Condition: Unknown
Due 8 January 1988
Resolved 8 January 1988
Accommodation/Occupational Safety
Issued 8 January 1988
Resolved
OPERATING AND MAINTENANCE INSTRUCTIONS FOR MARINE SANITATION DEVICE TO BE MAINTAINED ON BOARD. (33 CFR)
Condition: Unknown
Due 8 January 1988
Resolved 8 January 1988
Deck/Cargo
Issued 8 January 1988
Resolved
CONDUCT ANNUAL HYDRO TEST OF FUEL OIL TRANSFER HOSES PRIOR TO NEXT USE. MAINTAIN APPROPRIATE RECORD OF TEST.
Condition: Unknown
Due 8 January 1988
Resolved 8 January 1988
Unknown
Issued 8 January 1988
Resolved
PROVIDE RELIEF VALVE SET AT NOT MORE THAN 100 PSI/210 DEGREES F. FOR HOT WATER HEATER.
Condition: Unknown
Due 8 January 1988
Resolved 8 January 1988
Lifesaving
Issued 8 January 1988
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 January 1988
Resolved 8 January 1988
Documentation
Issued 8 January 1988
Resolved
MAINTAIN AN OIL RECORD BOOK. 33 CFR 151.52
Condition: Unknown
Due 8 January 1988
Resolved 8 January 1988
Lifesaving
Issued 25 October 1987
Resolved
COMPLETE 76 ITEMS MARINE REQUIREMENT LIST ISSUED TO VESSEL ON 17OCT87
Condition: Unknown
Due 25 October 1987
Resolved 25 October 1987
Deck/Cargo
Issued 16 September 1985
Resolved
PROVIDE FIXED CONTIMENT FOR GRADE "E" LIQUID MUD PORT AND STBD CARGO HEADERAS REQUIRED BY 33 CFR 155.310 OF 2 BARREL CAP. EACH TO BE COMPLETED TO THESATISFACTION OF THE ATTENDING CG MARINE INSPECTOR PRIOR TO 16OCT85.
Condition: Unknown
Due 16 September 1985
Resolved 16 September 1985