Records from 1984 to 2008. Most recent: inspection, 12 September 2008.
Inspection history · 75
12 September 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3330855
11 August 2008
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3295434
12 March 2008
COC-MODU Renew · Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3239780
5 April 2007
COC-MODU Annual
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2868706
29 July 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2739872
15 March 2006
COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2589307
4 August 2005
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2451423
30 March 2005
COC-MODU Annual
Type not classified · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2323113
16 March 2004
Deficiency Check · Certificate of Compliance
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2000906
9 October 2003
Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1924736
27 September 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1917404
27 September 2003
Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1923897
25 July 2003
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1856663
22 May 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1799107
28 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1764327
24 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1762193
20 March 2003
Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1770260
13 February 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1755410
26 January 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1735491
26 January 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1735556
8 April 2002
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1602499
12 March 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1603321
4 March 2002
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1490709
18 November 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1075875
18 November 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1492258
27 August 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 772387
25 August 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073139
12 July 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 130309
23 June 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1068640
31 May 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1066975
7 May 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 15078
14 April 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1061597
5 March 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1435164
2 May 2000
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 816962
6 April 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1435011
5 January 2000
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 813790
4 December 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 6681
9 November 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 803297
10 March 1999
Deficiency Check · Letter of Compliance (Initial/Renewal)
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1427625
13 March 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1440013
17 October 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 776196
12 August 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 782312
10 July 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 781698
2 June 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1108827
27 March 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465899
17 March 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1095155
21 August 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 38959
30 July 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1089519
27 March 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1448751
11 August 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 74402
29 July 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 56816
11 May 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1209611
7 May 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1350486
27 March 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1466928
18 April 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1167656
4 April 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389801
11 May 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 830185
26 March 1993
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431206
17 November 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 676087
12 November 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 40124
31 July 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 124483
25 March 1992
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 942944
30 July 1991
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 934334
19 June 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 888658
17 June 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 889186
27 March 1991
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1226277
2 April 1990
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 929291
6 April 1989
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1344853
6 April 1988
Deficiency Check · Certificate of Compliance
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1343319
7 April 1987
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1021862
2 December 1986
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1331691
20 November 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1019293
7 April 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1310918
5 April 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 982920
23 March 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 975626
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 12 March 2008
Resolved
Replace air pressure gauge for breathing air bottles, port lifeboat. Upon replacement of guage ensure all installed bottles contain sufficient air per manufacturers specification.
Due 27 March 2008
Resolved 16 March 2008
Resolution: Gauge replaced and air system tested by 3rd party (SSI), certification provided to OCS MORMS.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 14 April 2005
Resolved
PROVIDE CRANE CERTIFICATES TO THE SATISFACTION OF CLASS.
Action required: 705 - Other - as specified
Resolved 4 August 2005
Resolution: PROVIDED CRANE CERTIFICATES TO CLASS.
Lifesaving › Inflatable Liferafts › Container Marking
Issued 30 March 2005
Resolved
PROVE DROP HEIGHT OF RAFTS IS APPROVED FOR THE STOWAGE HEIGHT.
Action required: 705 - Other - as specified
Resolved 4 August 2005
Resolution: RIG REPLACED EXISTING RAFTS WITH RAFTS THAT ARE RATED FOR A DROP HEIGHT OF 118 FEET.
Personnel › Certificates/Documents/Licenses
Issued 16 March 2004
Resolved
Provide proof of Panamanian licenses to meet safe manning certificate. LEGACY COMPONENT DESC: License, Mate
Action required: 705 - Other - as specified
Resolved 17 June 2004
Resolution: Received fax from OIM for Panamanian licenses.
Electrical › Electrical Distribution System (service)
Issued 27 September 2003
Resolved
Prior to operation, make repairs to electrical system to satisfaction of flag state.
Action required: 705 - Other - as specified
Resolved 7 October 2003
Resolution: Rcvd class report.
Operations/Management › FireFighting
Issued 4 March 2002
Resolved
UPDATE THE FIRE CONTROL PLAN TO INCLUDE THE NEW CO2 SYSTEM IN THE MAIN SWITCHBOARD. LEGACY COMPONENT DESC: Fire Control Plan
Due 4 April 2002
Resolved 8 April 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 4 March 2002
Resolved
REPLACE THE FIBERGLASS GRATING IN THE MACHINERY SPACE WITH CG APPROVED FIBERGLASS GRATING OR STEEL GRATING LEGACY COMPONENT DESC: Grating
Condition: Improper Installation
Due 4 May 2002
Resolved 8 April 2002
Construction/Loadline › Structures
Issued 4 March 2002
Resolved
CROP & RENEW A 4' X 8' STEEL SECTION OF THE PORT COMPANION WAY OVERHEAD. LEGACY COMPONENT DESC: Superstructure
Condition: Improper/Lack of Maintenance
Due 4 April 2002
Resolved 8 April 2002
Construction/Loadline
Issued 5 March 2001
Resolved
Renew overhead framing members one through six on stbd side of mud pit room.
Condition: Unknown
Due 5 April 2001
Resolved 11 April 2001
Construction/Loadline
Issued 5 March 2001
Resolved
Repair deck bracket for walkway IWO stbd lifeboat.
Condition: Unknown
Due 5 April 2001
Resolved 11 April 2001
Engineering
Issued 6 April 2000
Resolved
MAIN DECK STBD SIDE DIESEL VENT RISER - WASTED AND HOLED AT DECK. CROP ANDRENEW.
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Deck/Cargo
Issued 10 March 1999
Resolved
PROVIDE COPY OF THIRD PARTY CRANE REPORT.
Condition: Unknown
Due 10 April 1999
Resolved 29 March 1999
Electrical
Issued 10 March 1999
Resolved
DURING TOTAL RIG SHUTDOWN ALL GENERATORS DID NOT COMPLETELY SHUTDOWN. TO BE FIXED PRIOR TO THE RIG'S DEPARTURE FROM WC 38.
Condition: Unknown
Due 15 March 1999
Resolved 15 March 1999
Fire Fighting
Issued 13 March 1998
Resolved
Clean all fire station hose nozzles and grease the pattern adjusting rings.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Construction/Loadline
Issued 13 March 1998
Resolved
Make permanent repairs to wasted areas in mud pit room/mud pump room commonbulkhead.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Lifesaving
Issued 13 March 1998
Resolved
Install a loss-of-ventilation alarm system in mud pit room that detects actual ventilation flow and/or atmospheric pressure differential between pit room and pump room. Must be wired independently of vent fan motor controllers.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Documentation
Issued 13 March 1998
Resolved
Provide original of IOPP form "A" attachment onboard and fax copy of same to [name withheld].
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Engineering
Issued 27 March 1997
Resolved
CONDUCT LOW LUBE OIL, HIGH WATER TEMPERATURE AND OVERSPEED SAFETY SHUTDOWNSON ALL GENERATORS. CONDUCT TEST OF TOTAL RIG SHUT-DOWN._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Deck/Cargo
Issued 27 March 1997
Resolved
HYDROSTATICALLY TEST AND PROPERLY LABEL ALL FUEL TRANSFER HOSES.
Condition: Unknown
Due 7 April 1997
Resolved 7 April 1997
Engineering
Issued 27 March 1997
Resolved
CROP AND RENEW SALTWATER DISTRIBUTION MANIFOLD PIPING FOR GENERATOR COOLING.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Unknown
Issued 27 March 1997
Resolved
REMOVE HOLD-BACKS AND INSTALL DOOR LATCHES ON STAIR TOWER DOORS.
Condition: Unknown
Due 7 April 1997
Resolved 7 April 1997
Unknown
Issued 27 March 1997
Resolved
MAKE MUD PIT DOOR GAS TIGHT.
Condition: Unknown
Due 7 April 1997
Resolved 7 April 1997
Lifesaving
Issued 27 March 1997
Resolved
HYDROSTATICALLY TEST BREATHING AIR CYLINDERS IN LIFEBOAT NO. 2.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Lifesaving
Issued 27 March 1997
Resolved
REPAIR EMERGENCY LIGHTING THROUGHOUT RIG.
Condition: Unknown
Due 7 April 1997
Resolved 7 April 1997
Construction/Loadline
Issued 27 March 1997
Resolved
ADJUST WATERTIGHT DOOR THROUGHOUT RIG.
Condition: Unknown
Due 7 April 1997
Resolved 7 April 1997
Fire Fighting
Issued 27 March 1997
Resolved
HYDROSTATICALLY TEST AND SERVICE ALL PORTABLE FIRE EXTINGUISHERS. HYDROSTATICALLY TEST OR REPLACE FLEXIBLE HOSE TO FIXED CO2 SYSTEM. UPDATE AND MAINTAIN MAINTENANCE LOG FOR FIREFIGHTING EQUIPMENT.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Lifesaving
Issued 27 March 1997
Resolved
REPAIR OR REPLACE GENERAL ALARM AT SHAKER HOUSE. INSTALL GENERAL ALARM IN DRY BULK TANK ROOM.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Accommodation/Occupational Safety
Issued 27 March 1997
Resolved
REPAIR BUNK LIGHTS AND INSTALL ADEQUATE LOCKER SPACE IN ACCOMMODATIONS.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Unknown
Issued 27 March 1997
Resolved
REPLACE TWO AIR COMPRESSOR PRESSURE RELIEF VALVES.
Condition: Unknown
Due 7 April 1997
Resolved 7 April 1997
Fire Fighting
Issued 27 March 1997
Resolved
CROP AND RENEW WASTED FIREMAIN PIPING AT FIRE STATIONS NO. 1 AND NO. 14.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Documentation
Issued 27 March 1997
Resolved
OBTAIN AN APPROVED FIRE AND CONTROL PLAN. ENSURE EXISTING EQUIPMENT ARRANGEMENT IS IN ACCORDANCE WITH APPROVED PLAN.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Accommodation/Occupational Safety
Issued 7 May 1995
Resolved
SUBMIT TO MSO PORT ARTHUR MANUFACTURER CONSTRUCTION DATA, ASME/ABS APPROVALINFORMATION AND DATA PLATE INFORMATION.
Condition: Unknown
Due 7 May 1995
Resolved 7 May 1995
Lifesaving
Issued 27 March 1995
Resolved
REPLACE LINE TO LIGHT FOR RING BUOY ON PORT SIDE AFT.
Condition: Unknown
Due 27 April 1995
Resolved 3 April 1995
Deck/Cargo
Issued 27 March 1995
Resolved
RENEW ALL BULK TANK RELIEF VALVES WITH VALVES HAVING SETTINGS BELOW RESPECTIVE TANK MAWP'S.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Deck/Cargo
Issued 27 March 1995
Resolved
MAKE READY FOR INSPECTION ALL RIG AIR RECEIVERS AND RELATED RELIEF VALVES.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Electrical
Issued 27 March 1995
Resolved
PRIOR TO NEXT RIG MOVE, PROVIDE DOCUMENTATION FOR FOLLOWING TESTS ON MAIN GENERATORS: LOW LUBE OIL, HIGH TEMPERATURE, REVERSE POWER, AND OVERSPEED SHUTDOWNS.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Lifesaving
Issued 27 March 1995
Resolved
PROVIDE PERSONAL MARKER LIGHTS FOR 12 LIFE PRESERVERS.
Condition: Unknown
Due 27 April 1995
Resolved 3 April 1995
Engineering
Issued 4 April 1994
Resolved
PROVIDE 30X30 MESH FLAME SCREENS FOR ALL PETROLEUM OIL HOLDING (STORAGE) TANKS (L/O, GEAR & CHAIN OIL, EMERGENCY GENERATOR SERVICE (F/O) TANK.
Condition: Unknown
Due 4 April 1994
Resolved 4 April 1994
Engineering
Issued 4 April 1994
Resolved
CROP AND RENEW MAIN GENERATOR SERVICE TANK F/O VENT.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Engineering
Issued 4 April 1994
Resolved
ADJUST AND PROVE PROPER OPERATION OF ALL MAIN GENERATOR PRIME MOVERS ALARMS(OVERSPEEDS, LOW OIL, HIGH WATER TEMP.) AND REVERSE POWER RELAY TRIPS.
Condition: Unknown
Due 4 April 1994
Resolved 4 April 1994
Construction/Loadline
Issued 4 April 1994
Resolved
ADJUST, REPAIR OR RECONDITION ALL WATERTIGHT DOORS AS NEEDED.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Engineering
Issued 4 April 1994
Resolved
STENCIL FUEL CUT OFF VALVES (EMERGENCY) FOR MAIN GENERATOR SERVICE TANK ANDEMERGENCY GENERATOR SERVICE TANK.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Electrical
Issued 4 April 1994
Resolved
REPAIR POWER CONNECTION TO EXHAUST FAN MOTOR ON MUD PIT.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Electrical
Issued 4 April 1994
Resolved
REPLACE GENERAL ALARM CONTACT MAKER ON DRILL FLOOR WITH ONE DESIGNED FOR HAZARDOUS LOCATIONS (EXPLOSION PROOF).
Condition: Unknown
Due 4 April 1994
Resolved 4 April 1994
Electrical
Issued 4 April 1994
Resolved
RESTRAP CABLE RUNS ON DERRICK AND SERVICE EQUIPMENT. CHANGE EYS FITTINGS ON DRILL FLOOR. MAKE PROPER WIRE CONNECTION TO SPEAKER IN SHALE SHAKER.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Documentation
Issued 4 April 1994
Resolved
MAKE PEN AND INK CHANGE TO HAZARDOUS LOCATION PLAN TO INCLUDE SUPPLY FAN FOR MUD PIT ROOM.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Electrical
Issued 26 March 1993
Resolved
INSTALL EYS FITTINGS ON J-BOX VICINITY OF SHALE SHAKER.
Condition: Unknown
Due 26 March 1993
Resolved 26 March 1993
Electrical
Issued 26 March 1993
Resolved
TEST ALL REMOTE SHUTDOWNS.
Condition: Unknown
Due 26 March 1993
Resolved 26 March 1993
Deck/Cargo
Issued 26 March 1993
Resolved
MAKE PRESSURE VESSELS AND RELIEF VALVES AVAILABLE FOR INSPECTION/TESTING.
Condition: Unknown
Due 26 March 1993
Resolved 26 March 1993
Lifesaving
Issued 26 March 1993
Resolved
REPAIR BROKEN SECTION OF OVERHEAD L/B NO. 1 AND REPAIR/RE-COAT BOTTOM OF L/B NO. 2.
Condition: Unknown
Due 26 March 1993
Resolved 26 March 1993
Lifesaving
Issued 26 March 1993
Resolved
CONDUCT FIRE AND BOAT DRILL.
Condition: Unknown
Due 26 March 1993
Resolved 26 March 1993
Electrical
Issued 26 March 1993
Resolved
INSTALL EYS FITTINGS TO ALL THREE REMOTE SHUTDOWN SWITCHES ON DRILL FLOOR.
Condition: Unknown
Due 26 March 1993
Resolved 26 March 1993
Documentation
Issued 7 April 1986
Resolved
MAINTAIN MASTERS LOG AS PER REGULATIONS (109.433).
Condition: Unknown
Due 7 April 1986
Resolved 7 April 1986
Electrical
Issued 7 April 1986
Resolved
INSTALL COVER FOR EMERGENCY GENERATOR VENT.
Condition: Unknown
Due 7 April 1986
Resolved 7 April 1986
Electrical
Issued 7 April 1986
Resolved
INSTALL COVER PLATES FOR FRONT AND BACK OF DISTRIBUTION PANEL IN MACHINERY SPACE.
Condition: Unknown
Due 7 April 1986
Resolved 7 April 1986
Accommodation/Occupational Safety
Issued 7 April 1986
Resolved
PROVIDE HAND RELIEVING GEAR FOR TWO (2) RELIER VALVES ON BULK CHEMICAL PRESSURE VESSELS.
Condition: Unknown
Due 7 April 1986
Resolved 7 April 1986
Electrical
Issued 7 April 1986
Resolved
INSTALL RUBBER MATS BEHIND SWITCHBOARD.
Condition: Unknown
Due 7 April 1986
Resolved 7 April 1986
Lifesaving
Issued 7 April 1986
Resolved
REPAIR OR REPLACE FORWARD LIMIT SWITCH ON CAPSULE #1.
Condition: Unknown
Due 7 April 1986
Resolved 7 April 1986
Lifesaving
Issued 7 April 1986
Resolved
HAVE RIG PERSONNEL TRAINED TO CORRECTLY OPERATED THE PORTABLE EMERGENCY RADIO.
Condition: Unknown
Due 7 April 1986
Resolved 7 April 1986
Lifesaving
Issued 7 April 1986
Resolved
PROVIDE AUX. LINE FOR LINE THROWING APPLIANCE.
Condition: Unknown
Due 7 April 1986
Resolved 7 April 1986
Documentation
Issued 23 March 1984
Resolved
SUBMIT TO [name withheld], TEXAS FOR REVIEW, A CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 23 March 1984
Resolved 23 March 1984
Documentation
Issued 23 March 1984
Resolved
SUBMIT TO [name withheld], TEXAS FOR REVIEW AND APPROVAL, AN OPERATIONSMANUAL.
Condition: Unknown
Due 23 March 1984
Resolved 23 March 1984
Documentation
Issued 23 March 1984
Resolved
SUBMIT TO [name withheld], TEXAS A HAZARDOUS LOCATION DRAWING FOR RE- VIEW.
Condition: Unknown
Due 23 March 1984
Resolved 23 March 1984