Records from 1997 to 2020. Most recent: inspection, 19 August 2020.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 34
19 August 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7037713
19 November 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6858731
4 September 2019
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6803762
12 March 2019
Deficiency Check · In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6653382
22 August 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6519373
22 August 2018
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6519510
21 August 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6525322
12 January 2018
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6337290
12 January 2018
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6337340
12 January 2018
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6342236
11 January 2018
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6338580
15 January 2015
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5054158
5 March 2014
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4811094
21 January 2014
COE-Dockside
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4786569
1 November 2012
COE-Offshore
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4473495
1 November 2012
Type not recorded
No type recorded · Station Dauphin Island · USCG Heartland District (CGD-H) · Activity 4476350
1 November 2012
MTSA Verification · MARPOL · Deficiency Check · Industry Initiated Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4480337
7 February 2008
Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3143638
7 February 2008
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3143660
10 January 2008
MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3127874
4 September 2007
Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3048584
2 September 2007
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3045419
1 September 2007
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3048316
31 August 2007
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3044048
22 April 2005
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2340784
22 April 2005
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2340795
13 October 2004
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2219816
9 September 2004
MTSA Verification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2191006
13 May 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2067299
19 February 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2011266
1 February 2001
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 4268210
29 December 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 424311
24 September 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 155348
14 March 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 403103
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 August 2020
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the 100% of the vessels that has not obtained a valid COI.
Action required: 705 - Other - as specified
Resolved 20 August 2021
Resolution: COTP issued by MSU Houma, Vessel in LA, removed def/activity because COTP states vessel must be made available for Sub M inspection prior to departure from Larose Shipyard
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 September 2019
No resolution recorded
If a vessel does not have a TSMS, or a vessel has one but it does not address the condition of the vessel that has resulted in non-compliance or the necessary conditions under which the vessel may safely proceed to another port for repair, the owner, managing operator, or master must request permission to proceed from the cognizant OCMI in whose zone the noncompliance occurs or is discovered.
The vessel was issued a Permit to Proceed (PTP) on 16AUG2019 from Hampton Roads VA to Mobile AL, to then effect permanent hull repairs. Vessel violated the PTP and proceeded to New Orleans, requesting our presence to verify repairs. Prior to movement, the vessel shall either conduct permanent repairs at Bollinger shipyard or provide a transit plan to another shipyard for permanent repairs, to be reviewed and approved by the USCG Sector New Orleans.
Action required: 60 - Rectify deficiencies prior to movement
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 September 2019
No resolution recorded
Once permanent repairs have been conducted and verified by the USCG Sector New Orleans, once the vessel is returned to the water, and prior to movement, make the vessel available for inspection to ensure Subchapter M compliance.
Action required: 60 - Rectify deficiencies prior to movement
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 23 July 2019
Resolved
Hatch ring on port 2 ballast completed wasted/ gasket unable to stay in place.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2019
Resolved 13 August 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 July 2019
Resolved
Exhaust lagging completed depleated on each of the main diesel engines
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2019
Resolved 16 August 2019
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 23 July 2019
Resolved
Scale aft ballast tank to allow further inspection and possible UT of the wasted steel in tank
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 July 2019
Resolved 13 August 2019
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 23 July 2019
Resolved
Proper installation of approved methods for all temporary hull patches in #1 ballast tank port side and aft ballast tank port and starboard side.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 July 2019
Resolved 13 August 2019
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 May 2019
Resolved
Multiple compromises to the hull within the lazarette space were found during an internal survey of the vessel. Make temporary repairs to address watertight integrity within the space, to be assessed by a Coast Guard Marine Inspector. Vessel to haul out and begin permanent repairs within 30 days, to the satisfaction of a USCG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 June 2019
Resolved 13 August 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 29 April 2019
Resolved
The watertight bulkhead located at frame 4 has a bilge/ballast piping penetration with a broken closure valve and corresponding broken reach rod, utilized as access from the main deck level. Bulkhead and closure device arrangement is designed and on file for the assignment of the vessel's load line. Repair closure valve and reach road, to the satisfaction of the CG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2019
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency [fire] conditions. Multiple run of electrical cables and wiring were secured in the engine room space utilizing plastic zip ties. Secure cables and wire runs utilizing metallic bands iaw original designed installation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2019
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 18 April 2019
Resolved
Vessel to make permanent repairs to the portside water/fuel tank bulkhead previously addressed by USCG Sector NY. Vessel to undergo repair oversight consisting of cut-out, fit-up, back gouge, and final weld test to the satisfaction of a USCG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2019
Resolution: USCG marine inspector conducted repair oversight. ABS certified welder completed all welding beyond fit-up stage. Weld passed final air/soap test.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 12 March 2019
No resolution recorded
Multiple compromises to the hull within the lazarette/ballast space were found during an internal survey of the vessel. Make permanent repairs on 6 temporary repairs 5 in aft ballast and 1 on keel cooler just aft of collison bulk head, to address watertight integrity within the space, to be assessed by a Coast Guard Marine Inspector. Vessel to haul out and begin permanent repairs within 15 days, to the satisfaction of a USCG marine inspector. Repairs to be made prior to towing operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2019 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 August 2018
Resolved
Vessel master indicated that the water was present in the port fwd fuel tank. Water entered through the engine fuel oil filters and stopped both MDEs. Vessel to gas free the fwd two fuel oil tanks and verified presence of water for the aft two fuel oil tanks.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2018
Resolution: The fwd fuel oil tanks were gas free, discovered a small hole (3/8") betweent he fwd ballast tank and the port fwd fuel oil tank. Vessel installed a 2 inch round plate doubler as a temp fix.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 22 August 2018
Resolved
Vessel is not equipped with approriate number of line throwing appliances.
Action required: 705 - Other - as specified
Resolved 28 August 2018
Resolution: Vessel must be equipped with approriate number of line throwing appliances prior to making any transit beyond 3 NM from shore.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 22 August 2018
Resolved
Vessel conducted temp repair to the hole (3/8") between the fwd ballast tank and the port fwd fuel oil tank. Vessel to transit to Norfolk Virgina and conduct permanent repair to the satisfaction of the attending CG Marine Inspector.
Action required: 15 - Rectify deficiencies by next port
Resolved 9 May 2019
Resolution: USCG MI witness satisfactory air test using soap/water mixture to 1.5 psi. There were no visible defects or indications of air leaking through the weld seams of the permanent repair.
Navigation › Piloting/Steering › US Coast Pilot
Issued 10 January 2008
Resolved
Make appropriate corrections to all charts, light list, coast pilot, and tide and current tables through the most recent notice to mariners as required by 46 CFR 26.03-4 prior to 10 February 2008.
Action required: 705 - Other - as specified
Due 10 February 2008
Resolved 1 November 2012
Lifesaving › Buoyant Apparatus › Lifeline
Issued 10 January 2008
Resolved
Replace/Renew dry-rotted line on starboard ring buoy w/buoyant dark color line over 90 feet in length as required by 46 CFR 28.115 prior to 10 February 2008.
Action required: 705 - Other - as specified
Due 10 February 2008
Resolved 1 November 2012
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 10 January 2008
Resolved
Replace/Renew retroreflective material on ring buoys that has been painted over as required by 46 CFR 28.115 prior to 10 February 2008.
Action required: 705 - Other - as specified
Due 10 February 2008
Resolved 1 November 2012
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 10 January 2008
Resolved
Replace/Renew all site glasses to include 2 shut off valves and tubing as required by good marine practice prior to 10 February 2008.
Action required: 705 - Other - as specified
Due 10 February 2008
Resolved 1 November 2012
Stability › Watertight Integrity › General
Issued 10 January 2008
Resolved
Replace all gasket material on watertight doors with appropriately sized gaskets that do not require caulking to be held in place as required by 46 CFR 42.15-10 prior to leaving port.
Action required: 705 - Other - as specified
Due 10 February 2008
Resolved 10 January 2008
Stability › Watertight Integrity › General
Issued 10 January 2008
Resolved
Prove operation/watertight integrity of all watertight doors as required by 46 CFR 42.15-10 prior to leaving port
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2008
Resolved 10 January 2008
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 10 January 2008
Resolved
Repair/Renew wasted portions of sewage tank and piping and provide 3/4 full visual indicator as required by 33 CFR part 159 prior to 10 February 2008.
Action required: 705 - Other - as specified
Due 10 February 2008
Resolved 7 February 2008
Resolution: Replaced the sewage tank and piping, and provided a 3/4 full visual indicator as required by 33 CFR 159.
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 10 January 2008
Resolved
Provide International Tonnage Certificate as required by 46 CFR Part 69 prior to departing Steiner Shipyard, Bayou La Batre, AL.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2008
Resolved 1 November 2012
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 10 January 2008
Resolved
Provide fuel oil transfer procedures as required by 33 CFR 155.720 prior to 10 February 2008.
Action required: 705 - Other - as specified
Due 10 February 2008
Resolved 7 February 2008
Resolution: Provided fuel oil transfer procedures as required by 33 CFR 155.720.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 January 2008
Resolved
Provide brackets for oxygen/acetylene bottles as required by good marine practice prior to 10 February 2008.
Action required: 705 - Other - as specified
Due 10 February 2008
Resolved 1 November 2012
Lifesaving
Issued 29 December 1998
Resolved
Lifejackets and work vest must be stowed separately._x001C_ 46 C.F.R. 26.30-10
Condition: Unknown
Due 4 January 1999
Resolved 7 January 1999
Lifesaving
Issued 29 December 1998
Resolved
Provide on board enough lifejackets for crew (10)._x001C_ 46 C.F.R. 25.25-9(a)
Condition: Unknown
Due 4 January 1999
Resolved 7 January 1999
Lifesaving
Issued 29 December 1998
Resolved
Provide on board enough work vest for crew (5)._x001C_ 46 C.F.R. 26.30-1
Condition: Unknown
Due 4 January 1999
Resolved 7 January 1999
Documentation
Issued 29 December 1998
Resolved
Provide on board restricted radio license for the master._x001C_ 33 C.F.R. 164.72(a)(3)
Condition: Unknown
Due 4 January 1999
Resolved 7 January 1999
Lifesaving
Issued 29 December 1998
Resolved
Provide on board 2 ring buoys._x001C_ 46 C.F.R. 25.25.15
Condition: Unknown
Due 4 January 1999
Resolved 7 January 1999
Construction/Loadline
Issued 14 March 1997
Resolved
VESSEL IS REQUIRED TO SHOW NAME AND HAILING PORT ON HULL, 46 CFR 67.123
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Engineering
Issued 14 March 1997
Resolved
FLAME SCREENS ON FUEL TANK VENTS REQUIRE REPLACEMENT.
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Engineering
Issued 14 March 1997
Resolved
FIXED CONTAINMENT AT FUEL STATION DID NOT HAVE A MECH. MEANS TO BE CLOSED, (A WOODEN PLUG WAS BEING USED) 33 CFR 155.320
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Engineering
Issued 14 March 1997
Resolved
VESSEL REQUIRED TO HAVE OIL TRANSFER PROCDURES, 33 CFR 155.740
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997