Inspection history · 27
10 August 2026
DAPI Audit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8460697
9 April 2026
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8345193
1 August 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8207275
25 February 2025
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8084298
23 October 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8023960
16 October 2024
Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8019863
2 August 2023
Initial Certification · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7676215
17 March 2022
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7439333
28 April 2021
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7184642
11 March 2021
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7154100
8 May 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6408822
22 June 2015
Industry Initiated Exam · Deficiency Check · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5160505
13 January 2015
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5084687
29 June 2012
Industry Initiated Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4373106
30 September 2009
Industry Initiated Exam
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3606360
3 October 2008
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3337835
17 September 2008
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3327146
8 December 2005
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2549810
2 November 2005
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2548084
2 August 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2448896
13 June 2005
MTSA Verification
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2390011
16 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1970618
11 March 2003
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1763662
14 February 2000
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 11173
21 September 1998
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 504145
17 October 1997
Uninspected Towing Vessel
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1114923
1 May 1993
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 228020
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 April 2026
No resolution recorded
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the environment. Vessel suffered approximately 6"x40" hull breach below the waterline after making contact with a submerged object. Vessel suffered substantial water egress in the engine room and adjacent spaces. Vessel to conduct damage assessment and submit repair proposal to cognizant OCMI.
Action required: 60 - Rectify deficiencies prior to movement
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 October 2024
Resolved
A fixed fire pump must be capable of: Delivering water simultaneously from the two highest hydrants, or from both branches of the fitting if the highest hydrant has a Siamese fitting, at a pitot-tube pressure of at least 344 kilopascals (kPa) (50 pounds per square inch (psi)), and a flow rate of at least 300 liters per minute (lpm) (80 gallons per minute (gpm). Vessel was unable to reach 50 psi while testing fire pump.
46CFR142.325(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2024
Resolved 21 February 2025
Resolution: Verified installed and portable fire pump is able to provide and maintain required pressure and flow.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 October 2024
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. Port and Starboard bilges had excessive oil.
46CFR142.220
Action required: 10 - Deficiency Rectified
Due 23 October 2024
Resolved 23 October 2024
Resolution: Bilges clean in presence of MI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 October 2024
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: Be maintained to ensure proper operation. Port and Starboard shafts found to have excess cooling water leaking.
46CFR143.205(c)(1)
Action required: 10 - Deficiency Rectified
Due 23 October 2024
Resolved 23 October 2024
Resolution: Shaft bearing tightened in presence of MI.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 October 2024
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid into the machinery space.
Vessel reported an oil leak from a cracked fitting on the governor of the Starboard main engine which allowed oil to spray in the engine room causing a small fire.
46 CFR 142.220 &
46 CFR 143.220
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 October 2024
Resolution: Attended vessel and verified repairs to starboard engine fuel line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 August 2023
Resolved
Lifebuoys must have the following attachments and fittings: if more than one lifebuoy is carried, at least one must not have a lifeline attached. At least two lifebuoys on a towing vessel >26 feet must be fitted with a floating electric waterlight.
The waterlights need the correct type of line and to be secured around the body of the lifebuoy itself. All the lifebuoys onboard currently have a lifeline attached; remove lifeline from one, or fit a removable clip. The hailing port stencilled on some of the lifebuoys is incorrect.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2023
Resolved 11 September 2023
Resolution: The listed issues were addressed to the satisfaction of the attending Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 15 August 2023
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated.
Install permanent lagging on port and starboard main engine exhausts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2023
Resolved 20 September 2023
Resolution: Permanent lagging has been satisfactorily installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 August 2023
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces.
Battery operated smoke detector in the second deck passageway is malfunctioning and needs to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2023
Resolved 11 September 2023
Resolution: The smoke detector in questioned was replaced with a new one and tested satisfactorily in the presence of the attending Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 August 2023
Resolved
Electrical systems and equipment must function properly and minimize fire and shock hazards.
The following electrical wiring issues remain unresolved at this time:
-220V junction box for dryer power plug is not properly sealed.
-Various dead-end wires in the space immediately underneath the wheelhouse.
-Empty electrical conduits near the port push knee.
-Junction box missing a cover near a fuel tank vent on the starboard side main deck.
-Missing light covers in the second deck passageway and main deck quarters, port side.
-Starboard generator ground cable to battery wasted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2023
Resolved 19 September 2023
Resolution: The noted electrical issues were fixed to the satisfaction of the attending Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 August 2023
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weathertight function properly.
The watertight door on the starboard side main deck leading into the forward accommodations is not fully sealing/seating.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2023
Resolved 11 October 2023
Resolution: Received objective evidence from vessel rep that welding repairs had been carried out on the watertight door in question to correct the sealing/seating issue.
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 15 August 2023
Resolved
The inspection will ensure that the vessel is in satisfactory condition and fit for the service for which it is intended. The inspection will include inspections of the structure...
The steps and railing on the port side push knee are wasted and in need of repair/replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2023
Resolved 11 September 2023
Resolution: The wasted steps and railings were replaced to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 August 2023
Resolved
11117 - Lifebuoys must have the following attachments and fittings: At least one lifebuoy must have a lifeline, secured around the body of the lifebuoy. If more than one lifebuoy is carried, at least one must not have a lifeline attached; at least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110. Only 1 ring buoy has a waterlight and the battery type in the waterlight is incorrect (needs to be L91 Lithium battery). Also, all three have heaving lines (provide at least one heaving line with a removable clip).
46 CFR 141.360(c)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: Both waterlights provided with correct batteries. Amended deficiency #1a issued reflecting need for proper line connecting waterlight to body of ring lifebuoy, one w/o heaving line, and stencil current hailing port on all ring buoys.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 August 2023
Resolved
07110 - Each towing vessel must have hoses and nozzles: the hose must be a lined commercial fire hose 15 meters (50 feet) in length, at least 40 millimeters (1.5 inches) in diameter, and fitted with a nozzle made of corrosion-resistant material capable of providing a solid stream and a spray pattern. • The jacket on both fire hoses is worn and need to be replaced and there are 2 fire stations with only one nozzle.
46 CFR 142.325(d)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: Two new fire hoses were provided, as well as a second fire hose nozzle, to the satisfaction of the attending Marine Inspectors.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 August 2023
Resolved
07110 - A 40–B portable fire extinguisher must be located near the storage room or cabinet. There is no fire extinguisher mounted near the paint locker.
46 CFR 142.225(d)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: A 4A:80BC portable extinguisher was mounted on the interior of the door of a compartment nearby the paint locker, with a sign on the door indicating its location.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 August 2023
Resolved
07110 - A towing vessel must be equipped with an approved 160–B semi-portable fire-extinguishing system to protect the engine room. The 160B semi-portable (wheeled) extinguisher needs a bracket or other means of securing.
46 CFR 142.315(a)(3)(i)
46 CFR 162.039-3
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: The 160B semi-portable extinguisher was secured to the deck railing to the satisfaction of the attending Marine Inspectors.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 August 2023
Resolved
07113 - The owner, managing operator, or master of a towing vessel must ensure that the vessel's lifesaving and fire suppression and detection equipment complies with the applicable requirements of parts 141 and 142 of this subchapter and is in good working order. Fire main piping was leaking near the pump.
46 CFR 140.650
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: The leaking section of fire main piping was replaced in kind and the fire pump energized with no leaks observed on the fire main piping under normal working pressure.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 August 2023
Resolved
04103 - Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. Emergency light in the engine room was inoperable.
46 CFR 143.410(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: A replacement e-light was installed in the engine room and confirmed to be working properly to the satisfaction of the attending Marine Inspectors.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 August 2023
Resolved
07126 - Each towing vessel must be maintained and operated so as to minimize fire hazards. Port and starboard generators had excessive oil in coils.
46 CFR 142.220
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: Both generator coils were cleaned of excessive oil to the satisfaction of the attending Marine Inspectors.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 2 August 2023
Resolved
09110 - Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Multiple light fixtures in the engine room were found to be missing cover clips or broken.
46 CFR 143.400(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: All light fixtures in the engine room were found with the proper covers and clips to the satisfaction of the attending Marine Inspectors.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 2 August 2023
Resolved
09208 - Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Lagging was missing on port and starboard Engine exhaust manifolds.
46 CFR 143.220(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: Temporary exhaust wrap applied until the permanent ordered lagging arrives. Amended deficiency #9a issued permitting operations for 30 days until permanent lagging arrives.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 August 2023
Resolved
11108 - Every towing vessel equipped with an inflatable survival craft must have, in conspicuous places near each inflatable survival craft, approved placards or other posted instructions for launching and inflating inflatable survival craft. Liferaft launching/instruction placard missing.
46 CFR 141.320
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: Instruction placard posted on liferaft cradle to the satisfaction of the attending Marine Inspectors.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 August 2023
Resolved
10116 - Each towing vessel must carry on board and maintain the publications specified in 33 CFR 164.72(b). Vessel uses Rosepoint for charts and pubs, but at time of inspection it showed as last updated in October 2022. Additionally, the vessel currently does not have means of reliable Internet connectivity to obtain updates.
33 CFR 164.72(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: Hotspot provided for the vessel and Rosepoint updated.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 2 August 2023
Resolved
15113 - No later than July 22, 2019, the owner or managing operator must implement a health and safety plan. The health and safety plan must document compliance with this part and include recordkeeping procedures. A copy of the company’s Health and Safety Plan is not available onboard. Provide copy onboard (CG will need to review to make sure it addresses the necessary items listed in Sub M).
46 CFR 140.500(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: Electronic copy of McClean's Health and Safety Plan has been placed on the computer in the wheelhouse.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 2 August 2023
Resolved
10105 - Towing vessels must be equipped with an illuminated magnetic compass. Compass illumination only works when engines are powered up. Vessel rep to rewire for different power source that does not require engines running.
46 CFR 140.725(d)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: Separate red light for illumination of magnetic compass installed that is not dependent on main engine power.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 August 2023
Resolved
13104 - Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided for: high bilge levels. Alarms must be visible and audible at each operating station. Bilge high level alarm did not alarm at the operating station when tested.
46 CFR 143.230 (a)(5) and (b)(1)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: Wiring for bilge high level alarm fixed and bilge alarm tested in presence of attending Marine Inspector; confirmed proper functionality of audible and visual alarms in wheelhouse.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 August 2023
Resolved
09209 - Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. New gauges in engine room need protective cover over top.
46 CFR 143.400(f)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: Covers installed to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 August 2023
Resolved
07106 - Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. Individual battery operated smoke detectors are missing from some of the berthing areas and lounge spaces.
46 CFR 142.330(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: Individual battery operated detectors installed. Amended deficiency 16a issued to replace smoke detector in the second deck passageway, as it is currently malfunctioning.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 August 2023
Resolved
10109 - The sidelights of vessels of 20 meters or more in length shall be fitted with matt black inboard screens and meet the requirements of § 84.15. On vessels of less than 20 meters in length, the sidelights, if necessary to meet the requirements of § 84.15, shall be fitted with matt black inboard screens. Nav screens for sidelights are currently painted white; should be painted matte black.
33 CFR 84.05(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: Nav screens painted matte black to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 August 2023
Resolved
13101 - Propulsion machinery, including shafting must: be maintained to ensure proper operation. The packing gland on the shaft was leaking 1-2 drips a second.
46 CFR 143.205(c)(1)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: Packing gland adjusted and acceptable leakage rated observed while vessel underway for man overboard drill.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 2 August 2023
Resolved
03107 - All hatches, doors, and other openings designed to be watertight/weather-tight function properly. The gasket for the WTD for port steering void tank is missing.
46 CFR 140.610(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: New gasket fitted in the WTD to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 August 2023
Resolved
13199 - Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The arms for the rudder position sensors were deteriorated and need to be replaced.
46 CFR 143.205(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: Arms for rudder position sensors were cropped and renewed. Rudder position readings verified as working properly while underway to observe man overboard drill.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 2 August 2023
Resolved
09233 - An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard, or rail. The steering gear on the aft deck was left uncovered without guards on moving parts.
46 CFR 144.820
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: Protective grating/decking installed above the steering gear components on the aft deck to the satisfaction of the attending Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 August 2023
Resolved
99101 - The owner, managing operator, master or officer in charge of a navigational watch of a towing vessel must ensure: The strength of each component used for securing the towing vessel to the tow and for making up the tow is adequate for its intended service. Forward tow winches and associated tow gear not yet installed.
46 CFR 140.801(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: Both two winches installed onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 2 August 2023
Resolved
09106 - The vessel, including crew's quarters and the galley, must be kept in a sanitary condition. Neither bathroom onboard is currently in a sanitary condition.
46 CFR 140.505 (e)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: Upstairs bathroom is now in satisfactory condition. Downstairs bathroom has been gutted and in process of being redone.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 August 2023
Resolved
09209 - Electrical systems and equipment must function properly and minimize fire and shock hazards. There is unfinished wiring throughout the vessel including dead-end wires and uncovered junction boxes.
46 CFR 143.400 (a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2023
Resolution: Majority of wiring issues have been rectified at this time. Amended deficiency 24a issued to reflect outstanding wiring issues as of today's date.