Records from 2008 to 2026. Most recent: inspection, 29 July 2026.
Documentation record
Registered dimensions (L × B × D)274.0 ft × 50.0 ft × 14.0 ft
Registered tonnagegross 1,611 / net 1,611
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderST JOHNS SHIP BUILDING INC · PALATKA, FL, UNITED STATES · built 2008
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portWILMINGTON, NC
Trade endorsementsCoastwise, unrestricted, Registry, non-fishing vessel
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1611 - Simplified, Gross Ton
1611 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 35
29 July 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8442395
28 July 2025
Periodic Inspection · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8191238
20 July 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7965792
27 July 2023
Drydock Exam · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7753696
18 May 2023
Drydock Extension · Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7704743
4 May 2023
Internal Structural Exam · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7678957
15 September 2022
Annual Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7559324
4 August 2021
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7277202
9 July 2020
Administrative Inspection · MTSA Verification · Annual Inspection · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7001564
7 April 2020
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6936340
14 January 2020
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6889361
8 July 2019
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6736694
6 June 2018
Administrative Inspection · Hull Examination · COI Inspection · MTSA Verification · Examination of Repairs · Cargo Tank Internal · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6435785
21 May 2018
Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6429893
21 July 2017
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6216417
7 July 2016
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5931307
28 January 2016
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5805088
13 July 2015
Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5186184
17 October 2014
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5006804
11 July 2014
Annual Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4918346
3 June 2013
Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4609504
9 October 2012
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4459965
6 October 2011
Periodic Inspection · Internal Structural Exam · MTSA Verification · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4162470
29 September 2010
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3859510
20 September 2010
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3853802
31 August 2010
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3839099
13 April 2010
Examination of Repairs
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3717906
2 April 2010
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3708394
17 September 2009
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3596494
5 June 2009
Administrative Inspection
Administrative · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3495763
19 February 2009
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3420275
6 October 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3339985
3 October 2008
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3337835
17 September 2008
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3327146
17 July 2008
Internal Structural Exam · Cargo Tank Internal · MTSA Verification · Drydock Exam · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3270457
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 July 2026
Resolved
Each battery tray must be chocked with wood strips or their equivalent to prevent movement, and each tray must have non-absorbent insulating supports on the bottom and similar spacer blocks at the sides, or equivalent provisions for air circulation space all around each tray. Each battery tray must provide adequate accessibility for installation, maintenance, and removal of the batteries. Battery installation in deck house was not properly secured to the deck.
46 CFR 111.15-5(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 August 2026
Resolution: Battery trays installed
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 July 2026
Resolved
A vessel or object other than those referred to in paragraph (g) of this Rule being towed shall exhibit: Sidelights. Port and starboard navigation lights were inoperable.
33 CFR 83.24(e)(i)
Action required: 705 - Other - as specified
Resolved 5 August 2026
Resolution: New light brought onboard
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 July 2025
Resolved
Approved portable extinguishers must be installed in accordance with table 1 to § 34.50-10(a). 02 portable extinguishers had broken nozzles and were missing tamper seals. 46 CFR 34.50-10(a)
Prior to cargo operations.
Action required: 705 - Other - as specified
Resolved 28 July 2025
Resolution: Received objective evidence of FE repair / inspection.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 24 July 2024
Resolved
If the annual inspection reveals deficiencies in your vessel's maintenance, you must make any or all repairs or improvements within the time period specified by the [name withheld] containment contained various equipment inside, reducing the capacity of the designed containment.
//46 CFR 31.10-17(a)(3)//
Action required: 705 - Other - as specified
Due 8 August 2024
Resolved 8 August 2024
Resolution: Received objective evidence of barge containment cleaned out.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 July 2024
Resolved
All tank vessels are subject to the regulations contained in subchapter J (Electrical Engineering) of this chapter.Electric installations on vessels must ensure maintenance of services necessary for safety under normal and emergency conditions. Starboard navigation light electrical cable was not secured.
//46 CFR 31.35-1
//46 CFR 111.01-1(a)(1)
Action required: 705 - Other - as specified
Due 8 August 2024
Resolved 8 August 2024
Resolution: Received objective evidence of repaired navigation light wiring.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 15 September 2022
Resolved
Each cargo tank of a tank barge must have a high-level indicating device, P2, P3, P4, S2, S3, and S4 metering sticks were damaged and inoperable; replace metering sticks with new ones and test to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2022
Resolution: Attending MI verified the replacement and functionality of all replaced rising stick gauges; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 August 2021
Resolved
All portable and semiportable extinguishers on board tank vessels shall be of an approved type. Two extinguishers are not approved for service because the gages show that they are outside of the required specs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2022
Resolution: During annual inspection portable extinguishers were inspected and service records were verified to the satisfaction of the attending marine inspector; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 August 2021
Resolved
Fluid conditioners shall pass a fire test of 1700 degrees. Vessel has 3 plastic fluid conditioners with aluminum flame shields.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2022
Resolution: During annual inspection fuel oil conditioners were verified to be installed on board with the approved equipment/materials; all sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 9 July 2020
Resolved
Cargo hose carried on tank vessels must be suitable for oil service and designed to withstand pressure of shutoff head of cargo pump. Take (02) identified unserviceable cargo hoses out of service and remove from vessel.
Condition: Damaged By Earlier Event
Due 24 July 2020
Resolved 13 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 July 2020
Resolved
Each outlet or junction box must be securely attached to its mounting and be affixed so as to maintain its designated degree of protection. Fixture for cable and junction box for starboard nav light severely wasted. Prove proper supports in place for junction box and cable.
Condition: Damaged By Earlier Event
Due 24 July 2020
Resolved 13 July 2020
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 20 September 2010
Resolved
Repair the remote shutdown for the port cargo pump prime mover, the port cargo pump may not be used until this discrepancy is corrected.
Due 1 October 2010
Resolved 30 October 2010
Resolution: Replace the solenoid for the shutdown.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 20 September 2010
Resolved
Relpace the broken dogging bolts and handles where necessary on approximately (3) wind void hatches, # 1S, 3P, & 4P.
Due 8 October 2010
Resolved 6 October 2010
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 20 September 2010
Resolved
Provide for the monthly inspection of the portable fir extinguishers IAW NFPA 10.
Due 8 October 2010
Resolved 6 October 2010
Construction/Loadline › Hull › Bottom Plating
Issued 16 April 2010
Resolved
Make permanent repairs to the port bow IAW 46 CFR Subchapter D and NVIC 7-68. NLT 23MAY10.
Action required: 705 - Other - as specified
Due 23 May 2010
Resolved 16 April 2010