Records from 1999 to 2020. Most recent: inspection, 12 August 2020.
Documentation record
Registered dimensions (L × B × D)55.1 ft × 20.0 ft × 6.8 ft
Registered tonnagegross 87 / net 59
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGREENVILLE BARGE CONST · GREENVILLE, MS, UNITED STATES · built 1959
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWILMINGTON, NC
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it87 - Regulatory (Subpart C or D), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
12 August 2020
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7030830
12 January 2018
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6351840
28 March 2013
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4557806
13 February 2013
MTSA Verification · Industry Initiated Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4532736
2 April 2010
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3708394
17 December 2009
Industry Initiated Exam
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3652038
19 November 2008
Annual Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3381487
12 October 2007
MTSA Verification
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3078428
30 November 2006
Administrative Inspection
Administrative · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2831621
28 November 2006
Annual Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2831582
4 October 2006
Administrative Inspection
Administrative · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2793584
29 June 2006
MTSA Verification
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2709293
3 February 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2286101
31 August 2001
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 295033
30 August 2001
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 73644
3 May 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 32549
25 April 2000
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 17877
20 December 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 157327
28 February 1999
Type not recorded
No type recorded · Station South Padre Island · USCG Heartland District (CGD-H) · Activity 1510474
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 August 2020
Resolved
Owners and operators with only one existing towing vessel must have a valid Certificate of Inspection (COI) prior to July 20, 2020. This vessel has not obtained a valid COI in accordance with the regulations. This vessel shall be made available for a Coast Guard COI inspection, within 90 days. If an inspection is not completed prior to this date, this deficiency shall be changed to a code 60 (Rectify deficiency prior to movement) and the vessel will no longer be permitted to operate.
Action required: 705 - Other - as specified
Due 11 November 2020
Resolved 10 September 2020
Resolution: Vessel has been issued a workboat designation, see attached letter.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 4 October 2006
Resolved
Company is not currently enrolled with approved consortium.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 November 2006
Resolved 28 November 2006
Resolution: Company has valid drug program in place. All Sat.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 31 August 2001
Resolved
PROVIDE PROPER CERTIFICATION AND INSTRUCTIONS AVAILABLE FOR CREW OF THE PROPER OPERATION OF THE MARINE SANITATION DEVICE INSTALLED ONBOARD.
Condition: Unknown
Due 7 September 2001
Resolved 15 January 2009
Navigation › Piloting/Steering › Marine Charts
Issued 31 August 2001
Resolved
PROVIDE CURRENT CHARTS AND LIGHT LIST ONBOARD AS PER 33 CFR 164.72.
Condition: Unknown
Due 15 September 2001
Resolved 15 January 2009
Lifesaving
Issued 31 August 2001
Resolved
PFD's NOT READILY AVAILABLE FOR USE IN PILOT HOUSE.
Condition: Unknown
Due 26 October 2001
Resolved 26 October 2001
Lifesaving › Lifebuoys › Serviceable
Issued 31 August 2001
Resolved
PROVIDE A SERVICEABLE LIFE RING.
Condition: Unknown
Due 7 September 2001
Resolved 15 January 2009
Lifesaving › Work Vest › Condition
Issued 31 August 2001
Resolved
PROCEED TO NEAREST RECEPTION FACILTY TO PUMP OFF ALL OIL CONTAINED IN THE ENGINE ROOM BILGE.
Condition: Unknown
Due 5 September 2001
Resolved 15 January 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 31 August 2001
Resolved
PROVIDE MACHINERY GUARDS TO THE FRONT OF EACH MDE.
Condition: Unknown
Due 15 September 2001
Resolved 15 January 2009
Lifesaving › Work Vest › General
Issued 31 August 2001
Resolved
STOW ALL LOOSE GEAR ABOUT THE ENGINE ROOM DECK.
Condition: Unknown
Due 1 September 2001
Resolved 15 January 2009
Electrical › Electric Generation Source (service) › Panelboard
Issued 31 August 2001
Resolved
PROVIDE ELECTRICAL PROTECTION PANEL FOR BREAKER BOX LOCATED IN THE ENGINE ROOM.
Condition: Unknown
Due 15 September 2001
Resolved 15 January 2009