Records from 1992 to 2017. Most recent: inspection, 6 September 2017.
Documentation record
Registered dimensions (L × B × D)57.4 ft × 20.5 ft × 7.1 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCATERPILLAR · GUILD TN, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 32
6 September 2017
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6261118
10 August 2017
Industry Initiated Exam · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6237265
28 August 2016
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5994187
22 July 2016
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5973257
5 February 2015
MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5065004
14 January 2015
Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5053524
7 April 2012
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4282726
9 May 2011
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4006762
3 July 2009
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3537304
26 May 2009
Industry Initiated Exam · MTSA Verification · Deficiency Check · MARPOL · Administration
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3486056
27 October 2008
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3356898
23 June 2008
Uninspected Other · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3246439
29 August 2007
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3060716
23 July 2007
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3037265
16 July 2007
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3033868
23 August 2006
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2777225
5 November 2005
MTSA Verification · Deficiency Check · Uninspected Other
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2528870
3 June 2005
Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2378504
2 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1957650
1 November 2002
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1746095
29 November 2001
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1077358
27 September 2000
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 822350
22 January 2000
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 149610
8 November 1999
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 810521
21 October 1998
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 808821
2 November 1997
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 151280
28 October 1997
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 409472
12 March 1997
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 52784
16 November 1995
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 73401
3 July 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 122183
3 July 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 170844
26 June 1992
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 180609
Fire Fighting › Remote Fuel Shutoff › General
Issued 23 June 2008
Resolved
As per 46CFR207, install fuel shut-off valves as close as practicable to the fuel or day tanks. Ensure the valves are operable from outside the engineroom and are properly labeled.
Condition: Placed in Improper Service
Due 4 July 2008
Resolved 3 July 2008
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 23 June 2008
Resolved
Install; when alarm sounds go to your station; placard in the engine room.
Condition: Placed in Improper Service
Due 4 July 2008
Resolved 3 July 2008
Engineering › Steering Gear System › Hydraulic Hose
Issued 23 June 2008
Resolved
As necessary, replace chaffed steering hydraulic hoses.
Condition: Unknown
Due 4 July 2008
Resolved 3 July 2008
Construction/Loadline › Penetrations › Pipe Flange
Issued 23 June 2008
Resolved
Replace deteriorated port and stbd generator raw water rubber hoses located at the vessel side shell.
Condition: Unknown
Due 4 July 2008
Resolved 3 July 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 June 2008
Resolved
Remove exposed dead end wire in the port engine room, storage locker and properly secure the port generator main power cable.
Condition: Unknown
Due 4 July 2008
Resolved 3 July 2008
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 23 June 2008
Resolved
Clean vessel bilge (old absorbent pads, rags, oil filters, excess oil, ect) and remove excess flammables (rags, boxes, ect) from the engine room.
12. Weld the fractured port, stern handrail.
Condition: Placed in Improper Service
Due 4 July 2008
Resolved 3 July 2008
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 23 June 2008
Resolved
Prove proper operation of the stbd main engine, bridge console gauges.
Condition: Placed in Improper Service
Due 4 July 2008
Resolved 3 July 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 June 2008
Resolved
Properly secure the exposed electrical wire for the port deck locker heater.
Condition: Placed in Improper Service
Due 4 July 2008
Resolved 3 July 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 June 2008
Resolved
Properly wire and install the port and stbd tow knees deck lights.
Condition: Improper/Lack of Maintenance
Due 23 July 2008
Resolved 3 July 2008
Fire Fighting › Firemans Outfit › Axe
Issued 23 June 2008
Resolved
Properly secured the port deck locker fire axe.
Condition: Placed in Improper Service
Due 23 July 2008
Resolved 3 July 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 June 2008
Resolved
Properly secure the dangling over head wires in the engine room. Wires shall be supported every 24 inches with metal supports.
Condition: Improper/Lack of Maintenance
Due 4 July 2008
Resolved 3 July 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 23 June 2008
Resolved
Cover or guard exposed overhead galley florescent lights, install a globe on the exposed port deck locker overhead light and install a guard or cover on the overhead laundry room light.
Condition: Improper/Lack of Maintenance
Due 23 July 2008
Resolved 3 July 2008
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 5 November 2005
Resolved
Update vessels fuel oil transfer diagram/procedures.
Action required: 705 - Other - as specified
Due 5 November 2005
Resolved 5 November 2005
Documentation › Markings/Placards › Official Number (US)
Issued 5 November 2005
Resolved
Properly affix vessels official number to internal structural member of hull.
Action required: 705 - Other - as specified
Due 5 November 2005
Resolved 5 November 2005
Unknown
Issued 8 November 1999
Resolved
excess bilge waste.
Condition: Unknown
Due 19 November 1999
Resolved 19 November 1999
Fire Fighting
Issued 8 November 1999
Resolved
fire hose was missing port side.
Condition: Unknown
Due 19 November 1999
Resolved 19 November 1999
Construction/Loadline
Issued 8 November 1999
Resolved
remove oil water before next fuel transfer.
Condition: Unknown
Due 19 November 1999
Resolved 19 November 1999