Records from 1993 to 2026. Most recent: inspection, 2 April 2026.
Documentation record
Registered dimensions (L × B × D)76.0 ft × 30.0 ft × 11.2 ft
Registered tonnagegross 146 / net 99
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDAKOTA CREEK INDUSTRIES · ANACORTES, WA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portJUNEAU, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 January 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Net Ton
146 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 36
2 April 2026
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8320048
22 January 2026
Internal Structural Exam · Drydock Exam · Vessel Attendance
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8294818
1 April 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8104256
20 February 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7864552
4 January 2024
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7848528
9 November 2023
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7822743
8 December 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7606474
21 April 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7435516
12 November 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7349427
11 February 2021
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7134206
18 December 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7112306
29 January 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6898758
2 October 2019
Initial Certification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6826741
8 May 2012
Administration
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4780363
4 May 2010
Industry Initiated Exam · MTSA Verification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3733529
1 June 2009
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3495199
25 July 2007
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3076983
6 November 2006
MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2815338
1 September 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2766078
28 August 2006
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2762181
12 July 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2423860
3 November 2004
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2235049
3 March 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2017213
4 November 2002
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1701525
2 July 2001
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 170584
4 April 2001
Inclining Experiment
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1061584
28 August 1998
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 118453
24 September 1997
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 62319
11 June 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 663977
11 April 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 208970
7 June 1996
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 761477
5 June 1996
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 196393
18 May 1996
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 50163
29 April 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 196392
29 April 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 756399
12 August 1993
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 107193
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 4 January 2024
Resolved
Bridge-to-Bridge Certificate found expired. Licenses of radio stations are required to have current station documents. Return proof of renewed certificate.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2024
Resolved 19 March 2024
Resolution: Vessel got updated brideg-to-bridge certificate.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 January 2024
Resolved
Fuel filters found to not be marine grade. Each towing vessel must be maintained and operated so as to minimize fire hazards. Replace plastic elements of fuel filter with steel elements and return pictures to CG.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2024
Resolved 19 March 2024
Resolution: Fuel filters were replaced. Def cleared. ALSAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 January 2024
Resolved
Inspectors question the suitability of valves for bilge system to act as non-return check valves. All installed bilge piping must have a check valve in each bilge suction that prevents unintended backflooding. Verify type of valve used and return information to CG.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2024
Resolved 19 March 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 January 2024
Resolved
During underway, inspectors found excessive leaking around the shaft seal, suspected packing issue. Machinery must be maintained to provide for safe operation of towing vessel under normal and emergency conditions. Examine integrity of shaft seal at next drydock and replace packing.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 February 2024
Resolved 19 March 2024
Resolution: Shafts repacked during drydock.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 December 2022
Resolved
ALL HATCHES, DOORS, AND OTHER OPENINGS DESIGNED TO BE WATERTIGHT OR WEATHERTIGHT MUST FUNCTION PROPERLY. PORT AND STARBOARD ACCOMODATION EMERGENCY EXIT HATCHES LEAK AND STARBOARD SIDE DID NOT OPEN.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 23 December 2022
Resolved 4 January 2023
Resolution: Provided proof of water tightness through hose testing on main deck hatch entry.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 December 2022
Resolved
ELECTRICAL COMPONENTS THAT POSE AN ELECTRICAL HAZARD MUST BE IN AN ENCLOSURE. EXPOSED WIRING ON ENGINE ROOM GENERATOR SWITCHBOARD NEEDS TO BE REMOVED AND CAPPED.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2023
Resolved 13 December 2022
Resolution: EXPOSED WIRING WAS PLACED INSIDE APPROPRIATE ENCLOSURE, SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 December 2022
Resolved
EACH CABLE AND WIRE ON A TOWING VESSEL MUST BE INSTALLED. EXPOSED CONNECTION OF MSD BLOWER INSIDE ENGINE ROOM MUST BE HARDWIRED.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2023
Resolved 13 December 2022
Resolution: BLOWER FOR MSD SPACE WITHIN ENGINE ROOM HARDWIRED APPROPRIATELY, SAT.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 8 December 2022
Resolved
THE GENERAL ALARM MUST BE CAPABLE OF NOTIFYING PERSONS IN THE ENGINE ROOM AUDIBLY. BELL INSIDE ENGINE ROOM IS BROKEN AND NEEDS REPLACEMENT.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2023
Resolved 13 December 2022
Resolution: WITNESSED VIDEO OF REPLACED AND WORKING AUDIBLE BELL IN ENGINE ROOM, SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 December 2022
Resolved
EACH LIFEBUOY ONBOARD MUST BE MARKED WITH THE NAME OF THE VESSEL. STARBOARD SIDE RING BUOY MISSING MARKINGS.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2022
Resolved 13 December 2022
Resolution: RING BUOY MARKED WITH VESSEL NAME, SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 November 2021
Resolved
Discharge of oil or oily mixture into seas is prohibited except when conditions under 33 CFR 151.10 are met. Alternatively the vessel may configure piping to retain oily mixtures until it can be discharged to a reception facility per 33 CFR 155.350.
Vessel has overboard discharge of machinery bilge spaces. Eliminate capabilities of discharge unless fitted with the proper oil separating unit. Remove all overboard piping from the machinery space bilge.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2021
Resolved 8 December 2022
Resolution: Means of pumping overboard have been removed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 12 November 2021
Resolved
EPIRB-The owner or managing operator must maintain valid proof of registration. Provide proof of updated registration sticker is applied to EPIRB.
46 CFR 141.380(d)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2021
Resolved 19 November 2021
Resolution: Received documentation that a replacement decal for the 406 MHz EPIRB was ordered.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 November 2021
Resolved
Drills and exercises must test the proficiency of vessel personnel in assigned security duties at all Maritime Security (MARSEC) Levels and the effective implementation of the Vessel Security Plan (VSP).
Exercises must be conducted at least once each calendar
year, with no more than 18 months between exercises.
Provide documentation of most recent company security
exercise.
33 CFR 104.230(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2021
Resolved 19 November 2021
Resolution: Owner/Operator sent documentation of most recent company security exercise.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 December 2020
Resolved
Vessel failed to demonstrate proper operation of bilge high level alarms. Vessel intends to replace alarm system during maitenance period in February 2021. Despite having a no sail, vessel is permitted to transit from current pier next to Ballard locks to Foss Shipyard in order to complete maitenance. Alarms must be verified by attending inspector prior to operations in April 2021.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 1 April 2021
Resolved 24 March 2021
Resolution: Bilge alarm system replaced and tested. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 December 2020
Resolved
Inoperable port running light, intentions to replace light during maitenance period in February 2021. Vessel is limited to daytime operations until port running light is replaced.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 April 2021
Resolved 24 March 2021
Resolution: Running lights replaced. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 December 2020
Resolved
Replace ship's label on 02 upper deck ring buoys adjacent to wheelhouse.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021
Resolved 24 March 2021
Resolution: Ring buoy's labeled with vessel's name.