Records from 1991 to 2003. Most recent: inspection, 11 March 2003.
Inspection history · 46
11 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1755617
12 November 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1709639
8 November 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1391717
21 August 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1063273
21 August 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073384
22 June 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1066961
31 May 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1066361
2 January 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1057703
10 August 2000
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1406739
2 August 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 821713
13 May 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1064118
20 January 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1029521
22 December 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 808564
1 December 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 811136
14 July 1998
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1455614
27 May 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 791969
17 December 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 779862
11 December 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 778882
16 October 1997
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1394850
13 August 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1118194
19 June 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1371871
20 February 1997
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392612
10 February 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1104019
27 January 1997
Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1407811
27 December 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402363
19 December 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460044
2 December 1996
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1092513
21 October 1996
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438493
12 September 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468396
15 February 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1191622
31 January 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1184375
18 January 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 875816
7 December 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1188914
14 November 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 761539
31 October 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 197241
20 October 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402121
10 November 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1394218
7 January 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 851538
21 October 1993
Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455107
2 March 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 662283
1 February 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 40659
1 February 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 105100
26 February 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 662284
12 November 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1312880
23 July 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1005038
3 July 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 940701
Operations/Management
Issued 12 November 2002
No resolution recorded
PRIOR TO OPERATING AS A MODU ALL ITEMS NOTED IN NARRATIVE MUST BE COMPLETED TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Action required: 705 - Other - as specified
Unknown
Issued 10 August 2000
Resolved
SUBMIT OPERATIONS MANUAL FOR USCG APPROVAL.
Condition: Unknown
Due 10 August 2000
Resolved 10 August 2000
Construction/Loadline
Issued 10 August 2000
Resolved
COMPLETE ABS SURVEY AND SUBMIT GAGING REPORT TO THE [name withheld] WITH DIVER'S REPORT AND UNDERWATER VIDEO.
Condition: Unknown
Due 10 August 2000
Resolved 10 August 2000
Engineering
Issued 10 August 2000
Resolved
RENEW / RE-WORK FUEL OIL SUPPLY AND RETURN LINES FOR DRAW WORKS PRIME MOVERS. NO SECTION OF FLEX LINE TO EXCEED 30" IN LENGTH.
Condition: Unknown
Due 12 September 2000
Resolved 12 September 2000
Electrical
Issued 10 August 2000
Resolved
PROVIDE CLASS 1 DIV 1 ELECTRICAL FIXTURES FOR INTERIOR OF PAINT LOCKER.
Condition: Unknown
Due 12 September 2000
Resolved 12 September 2000
Construction/Loadline
Issued 10 August 2000
Resolved
UT OVERHEAD STIFFENERS IN #2 STBD, SIDESHELL STIFFENERS IN #5 STBD, AFT VERTICAL STIFFENERS IN #6 STBD, AND OVERHEAD STIFFENERS AND CORNER GUSSETS_x001C_IN #4 STBD.
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Construction/Loadline
Issued 10 August 2000
Resolved
CROP AND RENEW STBD / AFT CORNER FIVE FOOT FWD OF CORNER TO AFT SEAM ON STERN BULKHEAD.
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Construction/Loadline
Issued 10 August 2000
Resolved
REPAIR FWD BULKHEAD OF #4 CENTERLINE.
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Lifesaving
Issued 10 August 2000
Resolved
CONDUCT ADEQUATE FIRE AND ABADON DRILL IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 15 October 2000
Resolved 8 November 2001
Construction/Loadline
Issued 10 August 2000
Resolved
MAKE ALL THROUGH HULL FITTINGS AVAILABLE FOR INSPECTION BY ABS OR COAST_x001C_ GUARD MARINE INSPECTOR._x001C_
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Unknown
Issued 10 August 2000
Resolved
PROVIDE UPDATED S.O.P.E.P. (APPROVED) TO THE [name withheld].
Condition: Unknown
Due 10 August 2000
Resolved 10 August 2000
Lifesaving
Issued 10 August 2000
Resolved
PROVIDE REPLACEMENT / INSTALLATION DATE OF LIFERAFT DAVIT FALLS OR REPLACE FALLS AND CONDUCT WEIGHT TEST.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Construction/Loadline
Issued 14 July 1998
Resolved
Complete following repairs to ballast tank internals: #5 stbd - crop and renew two outboard vertical chords, #6 port - crop and renew two bent bottom longitudinals, #6 stbd - crop and renew three bent overhead deck stiffeners.
Condition: Unknown
Due 4 September 1998
Resolved 4 September 1998
Construction/Loadline
Issued 14 July 1998
Resolved
Conduct Phase II of Special Examination in Lieu of Drydocking (SEILODD), i.e., leg-to-mat critical weld examination and diver swimby of mat. Must be conducted at next rig move upon leaving Port of Fourchon.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Fire Fighting
Issued 16 October 1997
Resolved
RENEW WASTED FIRE MAIN PIPE AT FIRE STATIONS #5 AND #6.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Accommodation/Occupational Safety
Issued 16 October 1997
Resolved
RENEW WASTED HAND RAILS BY #6 FIRE STATION AND PORT SIDE LIFE RAFTS.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Fire Fighting
Issued 16 October 1997
Resolved
REPAIR ALL FIRE FIGHTING EQUIPMENT AS PER TOTAL SAFETY SERVICE REPORT.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Documentation
Issued 16 October 1997
Resolved
PROVIDE PROPER PERSONNEL FOR REQUIRED MANNING, NEED 1 AB IN ADDITION TO 1 ONBOARD.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Lifesaving
Issued 16 October 1997
Resolved
REFILL THE EYEWASH STATION ON THE DRILL FLOOR.
Condition: Unknown
Due 3 November 1997
Resolved 3 November 1997
Construction/Loadline
Issued 16 October 1997
Resolved
MAKE REPAIRS AS REQUIRED IN ABS REPORT #BT 4432 DATED 15 OCT 97.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Lifesaving
Issued 16 October 1997
Resolved
TEST TOTAL RIG SHUT DOWN PRIOR TO NEXT RIG MOVE.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Engineering
Issued 16 October 1997
Resolved
RENEW FUEL TRANSFER HOSE.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Unknown
Issued 16 October 1997
Resolved
TEST RELIEF VALVES AT DRILL FLOOR AIR RECIEVERS.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Documentation
Issued 16 October 1997
Resolved
PROVIDE TRAINING MATERIAL FOR FIRE FIGHTING EQUIPMENT.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Lifesaving
Issued 16 October 1997
Resolved
SERVICE HOOK FOR STBD LIFERAFT HOOK.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Engineering
Issued 16 October 1997
Resolved
RENEW BAD FUEL LINE ON #2 GEN.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Engineering
Issued 16 October 1997
Resolved
REPLACE FUEL DAY TANK SIGHTGLASS WITH PROPER MATERIAL.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Construction/Loadline
Issued 16 October 1997
Resolved
REPLACE ALL WASTED KICK PIPES.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Fire Fighting
Issued 16 October 1997
Resolved
PROVIDE 12 FT APPLICATORS AT HELO DECK FIRE STATIONS.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Construction/Loadline
Issued 16 October 1997
Resolved
REPLACE DOOR GASKETS ON GALLEY DOOR AND PORT SIDE ENGINE ROOM DOOR.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Navigation
Issued 27 January 1997
Resolved
RE-POSITION AND PROVIDE APPROPRIATE SCREEN FOR STERN LIGHT PER COMDTINST M16672.2B (NAVIGATION RULES) RULES 24(e) AND 21(c).
Condition: Unknown
Due 27 January 1997
Resolved 27 January 1997
Lifesaving
Issued 27 January 1997
Resolved
REPLACE/REPAIR AS NECESSARY HELIDECK PERIMETER FENCE PER 46 CFR 108.235(e).
Condition: Unknown
Due 27 January 1997
Resolved 27 January 1997
Lifesaving
Issued 27 January 1997
Resolved
PROVIDE FLAME SCREENS AND RENEW VENT PIPING FOR OIL SERVICE TANK LOCATED ONTOP OF QUARTERS PER 46 CFR 56.50-85(a)(8).
Condition: Unknown
Due 27 January 1997
Resolved 27 January 1997
Construction/Loadline
Issued 27 January 1997
Resolved
PROVIDE COAST GUARD APPROVED PLANS FOR BALLAST TANK DUMP VALVE INSTALLATIONS PER 46 CFR 91.45-1(b).
Condition: Unknown
Due 27 January 1997
Resolved 27 January 1997
Construction/Loadline
Issued 27 January 1997
Resolved
PROVE PROPER OPERATION AND INSTALLATION OF BALLAST TANK DUMP VALVES PER COAST GUARD APPROVED PLANS PER 46 CFR 91.45-5(a).
Condition: Unknown
Due 27 January 1997
Resolved 27 January 1997
Electrical
Issued 27 January 1997
Resolved
PROPERLY SECURE HELIDECK PERIMETER LIGHT ELECTRICAL CONDUCTOR PER IEEE.
Condition: Unknown
Due 27 January 1997
Resolved 27 January 1997
Lifesaving
Issued 19 December 1996
Resolved
REPAIR EYEWASH STATION AT MUD PIT.
Condition: Unknown
Due 19 December 1996
Resolved 19 December 1996
Lifesaving
Issued 19 December 1996
Resolved
REPAIR AND LABEL GENERAL ALARMS THROUGHOUT.
Condition: Unknown
Due 19 December 1996
Resolved 19 December 1996
Lifesaving
Issued 19 December 1996
Resolved
REPAIR PURGE ALARM ON DRILL FLOOR.
Condition: Unknown
Due 19 December 1996
Resolved 19 December 1996
Lifesaving
Issued 19 December 1996
Resolved
TIGHTEN EXPLOSION PROOF FITTING IN PAINT LOCKER, PLACE INSTRUCTIONS FOR FIXED CO2 SYSTEM AT PAINT LOCKER.
Condition: Unknown
Due 19 December 1996
Resolved 19 December 1996
Electrical
Issued 19 December 1996
Resolved
REPAIR ALARM ON #2 GENERATOR. REPLACE STARTING BATTERIES #2 GENERATOR. CONDUCT EMERGENCY SHUTDOWN TESTS ON #2 GENERATOR. TEST BOTH REVERSE POWER RELAYS.
Condition: Unknown
Due 19 December 1996
Resolved 19 December 1996
Engineering
Issued 19 December 1996
Resolved
MOUNT FUEL TRANSFER PROCEDURES AND PROPERLY LABEL FUEL TRANSFER HOSE.
Condition: Unknown
Due 19 December 1996
Resolved 19 December 1996
Accommodation/Occupational Safety
Issued 19 December 1996
Resolved
PLACE 100 PSI SAFETY RELIEF VALVES ON HOT WATER HEATERS.
Condition: Unknown
Due 19 December 1996
Resolved 19 December 1996
Lifesaving
Issued 19 December 1996
Resolved
REPLACE MUD BLOWER MANUAL START EXPLOSION PROOF FITTING ON DRILL FLOOR. MOUNT EXPLOSION PROOF OUTLET AT MUD PIT.
Condition: Unknown
Due 19 December 1996
Resolved 19 December 1996
Construction/Loadline
Issued 19 December 1996
Resolved
TIGHTEN WATERTIGHT DOORS THROUGHOUT.
Condition: Unknown
Due 19 December 1996
Resolved 19 December 1996
Fire Fighting
Issued 19 December 1996
Resolved
REPLACE FIRE HOSE AND REPLACE FIRE PUMP SEAL.
Condition: Unknown
Due 19 December 1996
Resolved 19 December 1996
Navigation
Issued 19 December 1996
Resolved
REPAIR FOGHORN.
Condition: Unknown
Due 19 December 1996
Resolved 19 December 1996
Construction/Loadline
Issued 19 December 1996
Resolved
RENEW WASTED HELO DECK PERIPHERAL NETTING SUPPORTS.
Condition: Unknown
Due 19 December 1996
Resolved 19 December 1996
Construction/Loadline
Issued 21 October 1996
Resolved
GUAGE PORT AND STBD PRESSURE VESSELS IN ENGINEROOM. PROVIDE P/V DOCUMENTATION AND GUAGING REPORT TO MSO MORGAN CITY.
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Construction/Loadline
Issued 21 October 1996
Resolved
CROP & RENEW BOTTOM LONGS, INBOARD BAY IN #6 STARBOARD BALLAST TANK
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Construction/Loadline
Issued 21 October 1996
Resolved
CROP & RENEW BUCKLED AND CRACKED AREA OF CHORD ON OUTBOARD SIDE, FIRST FRAME AFT, #5 STARBOARD BALLAST TANK
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Fire Fighting
Issued 21 October 1996
Resolved
REPAIR LEAKING 4" PIPE IN #2 CENTERLINE BALLAST TANK
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Construction/Loadline
Issued 21 October 1996
Resolved
CROP & RENEW ALL EXTERIOR MAIN DECK MANHOLE COVER FLANGES ON BALLAST TANKS
Condition: Unknown
Due 21 October 1996
Resolved 21 October 1996
Construction/Loadline
Issued 21 October 1996
Resolved
COMPLETE REPAIRS AS LISTED ON ABS SUMMARY REPORT OF CLASS SURVEY DATED 26AUG96.
Condition: Unknown
Due 21 October 1996
Resolved 21 October 1996
Construction/Loadline
Issued 12 September 1996
Resolved
MAKE PERMANENT REPAIRS TO SIDE SHELL PLATING FRACTURE ON PORT SIDE OF MAT._x001C_
Condition: Unknown
Due 12 September 1996
Resolved 12 September 1996
Lifesaving
Issued 18 January 1996
Resolved
CONDUCT WEIGHT TEST ON LIFE RAFT DAVITS.
Condition: Unknown
Due 18 January 1996
Resolved 18 January 1996
Documentation
Issued 20 October 1995
Resolved
POST WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Documentation
Issued 20 October 1995
Resolved
POST CG APPROVED SAFETY PLAN.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Documentation
Issued 20 October 1995
Resolved
PROVIDE, ON BOARD, VALID LOADLINE CERTIFICATE.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Documentation
Issued 20 October 1995
Resolved
PROVIDE, ON BOARD, CG APPROVED OPERATION MANUAL.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Fire Fighting
Issued 20 October 1995
Resolved
MAKE OPERATIONAL GENERAL ALARM CONTACT-MAKER IN PILOTHOUSE.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Documentation
Issued 20 October 1995
Resolved
PROVIDE EVIDENCE OF MARINE DOCUMENT FOR 1 AB ON BOARD._x001C_
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Lifesaving
Issued 20 October 1995
Resolved
RENEW EXPIRED/MISSING ITEMS IN FIRST AID KIT IN TOOL PUSHER STATEROOM.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Lifesaving
Issued 20 October 1995
Resolved
CONDUCT WEIGHT TEST ON LIFE RAFT DAVITS.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Construction/Loadline
Issued 20 October 1995
Resolved
MAKE PERMANENT REPAIRS TO HELIDECK GIRDER STARBOARD SIDE._x001C_
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Lifesaving
Issued 20 October 1995
Resolved
REMOUNT SPEAKER BY DOGHOUSE._x001C_
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Accommodation/Occupational Safety
Issued 20 October 1995
Resolved
REPLACE BUNK LIGHT IN ROOM #6.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Electrical
Issued 20 October 1995
Resolved
PUT BLANK OVER MISSING CIRCUIT BREAKER IN ELECTRICAL DITRIBUTION PANEL #1.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Construction/Loadline
Issued 20 October 1995
Resolved
REPAIR WASTAGE ON PORT FORWARD WATERTIGHT DOOR TO MOTOR ROOM.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Electrical
Issued 20 October 1995
Resolved
PROPERLY SECURE CABLES ON DERRICK FOR DERRICK LIGHTING.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Electrical
Issued 20 October 1995
Resolved
RENEW PLEXIGLAS COVERS ON FLOURESCENT LIGHTS IN PUMP ROOM AND CLOSE COVERS.
Condition: Unknown
Due 28 October 1995
Resolved 27 October 1995
Electrical
Issued 20 October 1995
Resolved
REPAIR ELECTRICAL GROUNDS ON DEEP WELL PUMP AND A/C CONDENSER CIRCUITS.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Deck/Cargo
Issued 20 October 1995
Resolved
REPAIR/RENEW RELIEF VALVE FOR DRILL FLOOR AIR RECEIVER.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Electrical
Issued 20 October 1995
Resolved
REPAIR OVERSPEED TRIP #1 S/S GENERATOR._x001C_
Condition: Unknown
Due 28 October 1995
Resolved 27 October 1995
Construction/Loadline
Issued 20 October 1995
Resolved
REPAIR WASTAGE ON WEDGE RING FOR AFT LEG.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Lifesaving
Issued 20 October 1995
Resolved
RENEW AIR PIPING ON STARBOARD SIDE BELOW FUEL STATION.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995