Records from 2001 to 2021. Most recent: inspection, 3 March 2021.
Documentation record
Registered dimensions (L × B × D)156.7 ft × 30.0 ft × 12.3 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)156.7 ft × 30.0 ft × 12.3 ft
ITC tonnagegross 357 / net 107
BuilderSWIFTSHIPS INC · MORGAN CITY, LA, UNITED STATES · built 2001
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 2 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it107 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
357 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
3 March 2021
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7149428
13 March 2020
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6925983
17 April 2019
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6664792
8 April 2019
Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6658271
8 March 2018
Administrative Inspection · Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6368712
22 February 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6142520
7 March 2014
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4811988
25 March 2010
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3702583
25 March 2009
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3439771
20 March 2008
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3168377
27 March 2007
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2896209
14 September 2006
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2778650
12 May 2006
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2651501
20 March 2006
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2598092
11 March 2006
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2602207
21 March 2005
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2260489
18 March 2004
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2026903
11 July 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1843097
20 March 2003
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1727568
20 March 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1490850
20 March 2001
COI Inspection · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410539
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 April 2019
Resolved
ALL AUDIBLE BILGE ALARMS WERE NOT OPERABLE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2019
Resolved 23 April 2019
Resolution: WITNESSED THE AUDIBLE AND VISUAL BILGE ALARMS FUNCTION PROPERLY.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 April 2019
Resolved
Engines & jet drives 1,2,3,4 not ready for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2019
Resolved 23 April 2019
Resolution: Re-inspection sat, no issues found.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 25 March 2009
Resolved
A ground was detected in distribution system. Find and remove ground.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2009
Resolution: Ground isolated and repaired.
Fire Fighting › Remote Fuel Shutoff › General
Issued 25 March 2009
Resolved
Stbd side remote fuel shutoff does not operate correctly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2009
Resolution: Shutdown operates correctly and smoothly.
Lifesaving › Buoyant Apparatus
Issued 20 March 2002
Resolved
Stacked lifefloats did not have wooden slats separating them.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2002
Resolution: Slats provided.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 March 2002
Resolved
Light on aft ringbuoy dim.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2002
Resolution: Light replaced.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 20 March 2002
Resolved
Fire detector panel in pilothouse needed adjustment due to "reset" button sticking; when button sticks, no alarm would sound.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2002
Resolution: Panel adjusted so that button no longer stuck.