MAURY USCG vessel records
← All vessels

TAMARAW

Built
1945
Last inspected
6 April 2026
Controls
None recorded without a removal date
Also recorded as
ISLAND WARRIOR (2008)

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 6 April 2026
…with no type recorded24
Operational controls None recorded without a removal date
Years with a record 26 calendar years (1993–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8429850
WDF6478
205909
Flag
UNITED STATES
Tonnage
471 - Convention (Subpart B), Gross Ton 191 - Regulatory (Subpart C or D), Gross Ton 141 - Convention (Subpart B), Net Ton 130 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-205909
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

S-2007 Freight Barge · MISLE 869078 · 4 April 2022 · activity 7424671OCEANIA Freight Barge · MISLE 1073985 · 13 October 2020 · activity 7085489OCEANIA Freight Barge · MISLE 1073985 · 24 October 2015 · activity 5752341

Inspection history · 73

6 April 2026 Vessel Attendance · In-Service Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8343196
18 November 2025 Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8270126
3 October 2025 Administrative Inspection · In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8245729
12 August 2025 Drydock Exam · COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8208665
2 July 2025 Administrative Inspection · In-Service Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8173077
19 March 2025 Internal Structural Exam · Drydock Extension
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8095933
21 April 2024 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7899885
5 February 2024 Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7882728
14 April 2023 MARPOL Annex I Examination · MARPOL Annex VI Survey · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7669229
20 March 2023 Liferaft Servicing
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7651736
5 October 2022 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7573184
22 April 2022 MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7435865
19 April 2022 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7433638
14 April 2022 Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7439692
4 April 2022 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7424671
31 March 2022 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7533811
1 February 2022 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7411893
3 September 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7308836
22 March 2021 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7160369
4 January 2021 Deficiency Check · Administrative Inspection · Initial Certification
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7119626
13 October 2020 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7085489
11 June 2020 Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6973463
1 April 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6936786
28 January 2020 Deficiency Check · MARPOL Annex VI Survey · MARPOL Annex I Examination · Administrative Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6897520
25 November 2019 Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6861695
3 April 2019 MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6654786
27 March 2019 MARPOL Annex IV Survey · Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6649983
17 July 2018 Industry Initiated Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6485047
16 March 2018 MTSA Verification
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6372779
31 January 2018 MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6346684
3 October 2017 Bulk Liquid Transfer Monitor
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6280006
16 August 2017 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6242153
15 August 2017 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6242996
30 January 2017 MARPOL Annex VI Survey · MARPOL Annex I Examination · Deficiency Check · MTSA Verification · MARPOL Annex V Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6078175
20 May 2016 Administration
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5881690
25 January 2016 MARPOL · MTSA/ISPS Verification
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5804909
24 October 2015 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5752341
24 August 2015 Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5228965
17 February 2015 MARPOL Annex I Examination · MARPOL Annex VI Survey · MARPOL Annex V Examination · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5089961
8 January 2015 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5049870
7 January 2015 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5049877
7 August 2014 Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4946395
24 July 2014 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 4933054
7 July 2014 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4913288
6 July 2014 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4913410
2 July 2014 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 4925806
25 May 2014 MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 4867699
10 April 2014 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4832930
6 November 2013 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4748131
21 October 2013 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4738771
31 July 2013 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4696647
24 April 2013 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4575542
26 March 2013 MTSA/ISPS Verification · MARPOL · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4555977
31 December 2012 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4515586
5 June 2012 Administration
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4335313
20 March 2012 Administration · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4267485
29 January 2012 MTSA Verification · Deficiency Check · MARPOL · Industry Initiated Exam · Administration
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4234971
25 January 2012 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4231082
14 January 2011 MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3926327
23 December 2010 MARPOL
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3915093
8 December 2010 Industry Initiated Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3907196
15 November 2010 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3891885
23 January 2009 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3399017
24 October 2008 Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3352936
20 July 2007 Load Line/Change of Employment
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3049588
27 September 2006 MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2788518
24 April 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1805015
18 December 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1737291
19 June 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 96358
7 March 1996 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 103141
7 March 1996 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 166632
20 September 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 690105
14 September 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 6871

Deficiency record · 80

03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 September 2025 Resolved
Closure devices must be provided for deck house or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. Make water-tight to the satisfaction of the attending MI and or RO for the following: a. Main deck quick acting water tight doors b. Port and stbd gear locker tonnage openings c. Aft deck soft patch d. Focsle access scuttle
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2025
Resolution: WTDs gasket were replaced and chalk tested satisfactory to RO.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 September 2025 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the environment. Install missing fastening hardware for the following access covers to the satisfaction of MI or RO. a. Port and stbd FOT #8 b. Port and stbd FWT c. Stbd FOT #6 d. Port and stbd FOT #7 e. FWT in MSD space f. Forward main deck passageway access g. Port and stbd chain lockers
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2025
Resolution: All missing hardwares were re-installed to the satisfaction of RO.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 September 2025 Resolved
Closure devices must be provided for deck house or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. Replace gasket & chalk test for Provision Storeroom access hatch to lower deck to the satisfaction of the attending MI and or RO.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2025
Resolution: New gasket installed and chalk tested satisfactory to RO.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 September 2025 Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times. Install missing dogs for port holes for the following to the satisfaction of the attending MI and or RO: a. Stbd side forward and aft of main deck b. Crew mess c. Laundry room
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2025
Resolution: All missing dogs were installed to the satisfaction of RO.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 September 2025 Resolved
Where practicable and except as provided in § 144.515, each space where crew may be quartered or normally employed must have at least two means of escape. Arrangements on an existing vessel may be retained if it is impracticable or unreasonable to provide two means of escape. Repair escape ladder and prove proper operation of emergency escape scuttle from engine room and aft machinery workshop to the satisfaction of the attending MI and or RO.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2025
Resolution: Aft machinery shop's escape ladder has been repaired. Emergency escape scuttles for aft machinery shop and engine room have been repaired.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 September 2025 Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. Install sufficient emergency lighting in aft machinery work shop for safe egress through emergency escape scuttle to the satisfaction of the attending MI and or RO.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2025
Resolution: New emergency lightining was installed to the satisfaction of RO.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 22 September 2025 Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Replace and properly install expired hydrostatic release for life raft to the satisfaction of the attending MI and or RO.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2025
Resolution: New hydrostatic release was installed to the satisfaction of RO.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 22 September 2025 Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times. Make repairs to the leak on the Marine Sanitation Device to the satisfaction of the attending MI and or RO.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2025
Resolution: MSD leak was repaired to the satisfaction of RO.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 September 2025 Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with matte black inboard screens to meet the requirements of 84.15. Paint the navigation side lights screens matte black to the satisfaction of the attending MI and or RO.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2025
Resolution: Side lights were painted matte black to the satisfaction of RO.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 September 2025 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: Storage areas are kept free from accumulation of combustible and flammable materials insofar as practicable. Properly dispose collected used oil in aft machinery work shop to shore or designated waste oil tank prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2025
Resolution: Excess waste oil was transferred to designated waste oil tank.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 22 September 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Replace cracked and or extinguished light fixtures for the following: a. Tow winch room b. Engine room c. Starboard side exterior light d. Port side bridge wing
Action required: 705 - Other - as specified
Due 22 November 2025
Resolved 18 November 2025
Resolution: New light fixtures and lenses found fitted in mentioned spaces. Al other lights found functional and with appropriate cages and/or plastic lenses.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 September 2025 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the environment. Repair, remove, or place dead end wires in approved junction box for the following: a. Port generator exposed wiring by electrical starter b. Inoperable hydraulic pump clutch shut off switch c. Aft deck speaker
Action required: 705 - Other - as specified
Due 22 November 2025
Resolved 18 November 2025
Resolution: Electrical housekeeping items found satisfactory in mentioned areas. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 September 2025 Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. This is not meant to restrict access to towing equipment such as winches, drums, towing gear or steering compartment equipment necessary for the operation of the vessel. Install rotating guards for the exposed gears for the capstan in provision store room.
Action required: 705 - Other - as specified
Due 22 November 2025
Resolved 18 November 2025
Resolution: New guards found fitted/welded to brackets to prevent accidental touching of gearing for capstan. Found sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 September 2025 Resolved
The following systems must be equipped with gauges at the machinery location. The local gauges listed below are unreadable. Replace the following: a. Stbd generator fuel oil pressure broken b. Main engine oil pressure gauge cracked c. Reduction gear air pressure gauges cracked
Action required: 705 - Other - as specified
Due 22 November 2025
Resolved 18 November 2025
Resolution: New gauges found fitted on main engine L/O pressure guage and reduction gear air pressure gauge. F/O pressure gauge on stbd generator found working appropriatley and readable, fitted with spare.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 September 2025 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: Storage areas are kept free from accumulation of combustible and flammable materials insofar as practicable. Repair hydraulic oil leaks to PTO in engine room for bow thruster.
Action required: 705 - Other - as specified
Due 22 November 2025
Resolved 20 November 2025
Resolution: Objective evidence provided in form of photos of new seal and nut securing hydraulic leak on PTOs for bow thruster. Attached to document section of this deficiency.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 22 September 2025 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the environment. Provide proposal for review and repair to address the wasted deck above the main shaft alley to the satisfaction of the attending MI and or RO.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2025
Resolved 17 December 2025
Resolution: Final repair verified, visual NDT. Internal engine room, non-watertight deck plate insert. See repair proposal and photos attached to document section of this deficiency.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 September 2025 Resolved
Sufficient lighting suitable for the marine environment must be provided within crew working and living areas. Make repairs to the life raft embarkation lightning to the satisfaction of the attending MI.
Action required: 10 - Deficiency Rectified
Resolved 23 September 2025
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 12 August 2025 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the environment. Propose a repair plan for review and effect permanent repairs to the crack on tank top of Port FOT #3 to the satisfaction of the attending MI and or RO.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2025
Resolution: Crack was permanently repaired to the satisfaction of RO.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 April 2024 Resolved
Except as provided by 33 CFR 164.01(b), each towing vessel must be equipped with the following navigational-safety equipment: A searchlight directable from the vessel's main steering station and capable of illuminating objects at a distance of at least two times the length of the tow. The forward searchlight is currently inoperable, vessel is restricted to daytime operations within Apra harbor. 33 CFR 164.72(a)(v)(2)
Action required: 705 - Other - as specified
Due 23 May 2024
Resolved 29 April 2024
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 April 2024 Resolved
Fixed fire-extinguishing system must be inspected and tested, as required by 142.240 of this section, in addition to tests required by 147.60 and 147.65 of subchapter N of this chapter. During annual inspection by Tech Plus, Inc. found engine room’s halon system hoses for CO2 activation bottle to manifold and both halon tanks hoses to manifold needs to be replaced. 46 CFR 142.240(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 24 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 April 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The fuel racor filter bowls for the main engine, port generator, stbd generator, and the winch engine must be highly resistant to shattering to due to mechanical impact. Fuel filter bowls other than steel construction will specify if a flame shield is required. 46 CFR 143.205(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 6 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 April 2024 Resolved
The following systems must be equipped with gauges at the machinery location. The port side generator’s fuel oil pressure gauge is not reading accurate pressure. 46 CFR 143.230(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 21 May 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 April 2024 Resolved
All machinery and equipment that is not in proper working order (including missing or malfunctioning guards or safety devices) must be removed; made safe through marking, tagging, or covering; or otherwise made unusable. The machinery space bench grinder is missing its safety shield. 46 CFR 140.505(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 7 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 23 April 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Replace (4) cracked light fixture covers in the engine room. 46 CFR 143.205(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 24 June 2024
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 23 April 2024 Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings in such spaces. The stbd side engine room supply ventilation cover has two cracks approximately 12” long. 46 CFR 144.605
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 6 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 April 2024 Resolved
This subpart prescribes design requirements, approval tests, and procedures for approving retroreflective material used on life saving equipment. The aft of wheelhouse ring buoy’s retroreflective tape is worn and beyond serviceable. 46 CFR 164.018
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 21 May 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 21 April 2024 Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. Sludge tank vent is missing the wing nut preventing the cover from being closed. 46 CFR 144.320
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 21 May 2024
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 April 2024 Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. The emergency lights on the 01 deck is not working. 46 CFR 143.410(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 21 May 2024
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 April 2023 Resolved
Each EPIRB and each SART, other than an EPIRB or SART in an inflatable liferaft, must be tested monthly. The vessel crew were missing the monthly test of the EPIRB.
Action required: 10 - Deficiency Rectified
Due 24 April 2023
Resolved 14 April 2023
Resolution: Vessel rep and master will make sure to conduct the test on a monthly basis
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 April 2023 Resolved
The master of a towing vessel must ensure that each crewmember participates in fire-fighting drills and receives instruction at least once each month. The master was unable to provide evidence of a fire drill being conducted on a monthly basis.
Action required: 10 - Deficiency Rectified
Due 24 April 2023
Resolved 14 April 2023
Resolution: Conducted a satisfactory fire drill, vessel rep and master will make sure to conduct the drill on a monthly basis.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 April 2023 Resolved
A 40–B portable fire extinguisher must be located near the storage room or cabinet of paints and flammable/combustible products. THe vessel paint storage room ont he port side did not have a 40-B extinguisher near the space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2023
Resolved 17 May 2023
Resolution: All paints was removed from the vessel and no longer stored in the port side locker.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 14 April 2023 Resolved
Each vessel, except vessels operating on routes between 32 degrees north latitude and 32 degrees south latitude immersion suit or anti-exposure suit must be marked in such a way as to identify the person or vessel to which it belongs. The vessel was provided with new immersion suits that did not have the name of the vessel stenciled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2023
Resolved 24 April 2023
Resolution: Vessel stenciled the name of the vessel onto the Immersion suits.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 April 2023 Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. The door and pins for the pollution response equipment compartment was severely wasted. Vessel needs to repair or replace the door and pin to make it function properly and as intended.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2023
Resolved 23 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 5 October 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The vessel received extensive damage to her stbd Maine Engine Room vent and is unable to close the vent in an emergency. Vessel is to affect permanent repairs to the satisfaction of the attending CG Marine Inspector prior to conducting any towing operations.
Action required: 705 - Other - as specified
Resolved 10 October 2022
Resolution: Vessel completed permanent repairs.
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 22 April 2022 Resolved
EACH Cargo vessel of 150 gross tonnage and upwards but less than 500 gross tonnage must have installed a bridge navigation watch alarm system onboard not later than the first survey after 1 January 2018. Vessel is not outfitted with an operational BNWAS.
Action required: 702 - Prior to embarking on international voyage
Due 20 May 2022
Resolved 19 May 2022
Resolution: Vessel rep provided a Furuno BNWAS
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 22 April 2022 Resolved
A vessel on an OCEAN voyage more than 3 NM from shore must be equipped with a line throwing appliance. Vessel did not have the appropriate amount of line throwing appliance on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 19 May 2022
Resolution: Vessel rep provided the appropriate amount for line throwing appliance.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 22 April 2022 Resolved
Vessel must be manned IAW the COI safe manning. Vessel OS medical cert was expired and no documentation was provided for a satisfactory renewal submittal application to maintain the validity of the MMC.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2022
Resolved 19 May 2022
Resolution: Vessel rep provided the approriate licensed crewmemebr.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 3 February 2021 Resolved
Oil filtering equipment referred to in paragraph 2 of this regulation shall comply with paragraph 6 of this regulation. In considering the design of such equipment and approvals, the Administration shall have regard to the specification recommended by the Organization. Re-circulating facilities should be provided, after and adjacent to the overboard outlet of the stopping device to enable the 15ppm Bilge Separator system, including the 15ppm Bilge Alarm and the automatic stopping device, to be tested with the overboard discharge closed. Oil filtering equipment is not fitted with Re-circulating facilities required by MEPC 107(49)/6.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 3 February 2021 Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage. Vessel does not have required charts or nautical publications on-board and ready for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2021
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 February 2021 Resolved
Sufficient lighting suitable for the marine environment must be provided within crew working and living areas. The space containing the Marine Sanitation Device does not have fixed lighting installed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 February 2021 Resolved
Towing vessels more than 65ft in length must use navigation lights that meet UL 1104 or other standards accepted by the Coast Guard. Replace installed navigation lights with lights that meet UL 1104.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2021
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 3 February 2021 Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Secure the multiple exposed and dead ended wires and junction boxes in the space next to the Marine Sanitation Device.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2021
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 3 February 2021 Resolved
Where practicable and except as provided in § 144.515, each space where crew may be quartered or normally employed must have at least two means of escape. The means of escape in the shaft alley does not have a wheel on the interior of the vessel to operate the hatch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 February 2021 Resolved
The vessel is built, equipped, and maintained to conform to the rules of a recognized classification society appropriate for the intended service and routes. Complete repairs to the insert by the port side galley water tight door.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 February 2021 Resolved
The fire main must have a sufficient number of fire hydrants with attached hose to allow a stream of water to reach any part of the machinery space using a single length of hose. The three installed fire hydrants installed on the exterior of the vessels superstructure do not allow for a stream of water to reach any part of the machinery space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2021
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 3 February 2021 Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover guard or rail. There is no guard installed for the hydraulic pump unit’s prime mover in the machinery space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 February 2021 Resolved
To stop flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. The port side fuel oil day tank does not fully close when activated.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 February 2021 Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid. All fuel separators have non-metallic quick draining valve. Replace with metallic plugs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2021
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 3 February 2021 Resolved
Each towing vessel equipped with rudder(s) must have a means to monitor and control position of the rudders(s) at each operator station. The starboard rudder indicator at the operator station not functioning.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 January 2021 Resolved
A towing vessel, other than an excepted vessel, must have a backup or a second power source that has adequate capacity to supply the power to essential alarms, lighting, radios, navigation equipment, and any other essential system identified by the cognizant OCMI. Prove operation of the starboard generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2021
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 25 January 2021 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention: Alarms must: Be visible and audible at each operating station. The operating station has no audible or visual alarms for required machinery alarms or bilge high level alarms.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2021
Resolution: Alarm system cursory alarm panel operational at the operating station.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 25 January 2021 Resolved
Each vessel must be designed and constructed to minimize fire hazards insofar as reasonable and practicable. Several areas identified that pose fire hazards due to missing or incorrect boundary segregation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2021
Resolution: All areas have been corrected.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 January 2021 Resolved
Delivering water simultaneously from the two highest hydrant, or from both branches of the fitting if the highest hydrant has a Siamese fitting, at a pitot tube pressure of at least 50 psi and a flow rate of at least 80 gpm. Fire main piping has a pin hole leak above the port side general service pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 February 2021
Resolution: Fire main pin hole leak repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 January 2021 Resolved
Prepare vessel for initial sub chapter M COI inspection. Multiple safety, machinery and fire prevention issues identified on 25JAN2021.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2021
Resolution: COI inspection completed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 January 2021 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew members on inspected vessels. Crew member required to perform duties and functions directly related to the safe operation of the vessel was not enrolled in a random testing program.
Action required: 10 - Deficiency Rectified
Resolved 3 February 2021
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 28 January 2020 Resolved
Oil content meter shall be fitted with recording device to provide a continuous record of oil content in parts per million. MARPOL 73/78 REG 16.
Action required: 705 - Other - as specified
Due 28 February 2020
Resolved 28 February 2020
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 28 January 2020 Resolved
Standard discharge connection must have flange and gasket of oil-proof material. MARPOL 73/78 Reg 19.
Action required: 705 - Other - as specified
Due 28 February 2020
Resolved 28 February 2020
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 3 April 2017 Resolved
Marine Inspector (MI) observed messdeck fixed fire detector obstructed by crew. MI removed detector cover brought ashore.
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 3 April 2017
Fire Fighting › Fixed Fire Detection System › Approval
Issued 30 January 2017 Resolved
No P.E. or IACS approval letter for fire detection system.
Due 2 February 2017
Resolved 1 February 2017
Resolution: Documentation submitted to USCG.
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 January 2017 Resolved
Installed bilge alarm ooc.
Action required: 10 - Deficiency Rectified
Due 1 February 2017
Resolved 20 July 2018
Resolution: Verified bilge alarm functions and alarms in E/R and bridge.
Fire Fighting › Fire Pumps › Pressure
Issued 30 January 2017 Resolved
Pump discharge gauge max water pressure observed was 20 psi.
Due 1 February 2017
Resolved 1 February 2017
Resolution: Corrected to the satisfaction of attending MI.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 January 2017 Resolved
ooc
Due 1 February 2017
Resolved 1 February 2017
Lifesaving › Rigid Liferafts › Hydrostatic Release Unit
Issued 30 January 2017 Resolved
Installed Hydro release expires 1Feb17.
Due 1 February 2017
Resolved 1 February 2017
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 30 January 2017 Resolved
System not certified in the last 5 years.
Due 1 February 2017
Resolved 3 April 2017
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 January 2017 Resolved
Protective guards removed or missing from several pieces of machinery in engine room.
Due 1 February 2017
Resolved 1 February 2017
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 30 January 2017 Resolved
Missing junction box cover, exposing live electrical wiring.
Due 1 February 2017
Resolved 1 February 2017
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 30 January 2017 Resolved
Emergency egress of deck hatches from engine room obstructed. Hatch aft of machiner space, centerline, crew opened hatch after 10 minutes utilizing improvised tools.
Due 1 February 2017
Resolved 1 February 2017
Electrical › Electric Supply System (service) › Cable
Issued 30 January 2017 Resolved
Dead end wiring forward of water heater (2).
Due 1 February 2017
Resolved 1 February 2017
Documentation › Logs/Records › Garbage Recordkeeping
Issued 30 January 2017 Resolved
Multiple entry errors in Vessel Garbage Log. Some entries have not yet been made for garbage landed ashore.
Due 1 February 2017
Resolved 1 February 2017
Construction/Loadline › Markings › Load Line Mark
Issued 30 January 2017 Resolved
Load line was not legible.
Due 1 February 2017
Resolved 1 February 2017
Engineering › Reduction Gearing/Clutches › Oil Spray
Issued 24 August 2015 Resolved
Normal oil operating temperature range is between 140deg - 150deg, according to [name withheld] Vessel reduction gear oil temperature was recorded at 180 deg. Repair the casualty IAW manufacture recommendations to be attested by the attending CG MI.
Action required: 705 - Other - as specified
Resolved 20 July 2018
Resolution: Reduction gear has since been overhauled and found to be operating at normal tempatures.
Documentation › Logs/Records › Oil Record Book
Issued 17 February 2015 Resolved
Oil Record Book (Part I) is missing entries from 10FEB2015 removal of oil waste and 12FEB2015 weekly soundings.
Action required: 705 - Other - as specified
Due 17 March 2015
Resolved 17 March 2015
Resolution: Corrected.
Documentation › Logs/Records › Oil Record Book
Issued 17 February 2015 Resolved
Oil Record Book (Part I) is missing operational test of OWS.
Action required: 705 - Other - as specified
Due 17 March 2015
Resolved 17 March 2015
Resolution: Corrected.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 8 January 2015 Resolved
US and Foreign vessels bound for, or departing from places in the United States shall submit a Notice of Arrival prior to its arrival. 33CFR160.206 The UTV TAMARAW failed to submit a Notice of Arrival prior to its entrance into COTP Zone Guam.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 January 2015
Resolved 8 January 2015
Resolution: Vessel was educated about NOA requirements and issued a violation for their deficiency.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 7 July 2014 Resolved
Vessel could not provide valid Vessel Response Plan prior to entry into Apra Harbor and the territorial waters of the United States as required by 33CFR155.1030.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 August 2014
Resolved 7 July 2014
Resolution: M/V Tamaraw has received a Vessel Response Plan Approval Letter for Nontank Vessels which allows it to operate within Guam''s COTP Zone. Letter Expires July 07, 2019.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 1 December 2010 Resolved
Company failed to notify USCG of a reportable marine casualty that occured on or about 26 or 27 NOV10. USCG Sector Honolulu was on or about 30NOV10.
Due 1 December 2010
Resolved 5 July 2011
Resolution: Company issued an LOW for failure to notify of a reportable MC. Due date reflects when Sector Guam''s SIO was notified and reported violation to Company.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 14 May 2009 Resolved
33U.S.C.1321(j)(5)(D)(ii)-The NTVRP does not identify a qualified individual, provide 24-hour contract information for the qualified individual, or indicate that the qualified individual will have immediate contact with the NRC and the oil spill removal organization. 33 USC 1321(j)(5)(D)(i)-There is an inconsistency in the NTVRP in the intended areas of operation for the vessel.
Due 30 November 2010
Resolved 15 November 2010
Resolution: Company sent copy of NTVRP Approval Letter via email
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 14 May 2009 Resolved
33 U.S.C. 1321(j)(5)(D)(iv)-The NTVRP should be amended to identify a classified OSRO for the PW Snd COTP zone and provide proof of a valid contract with the listed OSRO. 33 U.S.C. 1321(j)(5)(D)(iv)-NTVRP lists NRC as the classified OSRO for the SE AK COTP zone. OSRO not classified to provide response resources in this zone. Need OSRO contract for SE AK COTP zone.
Due 30 November 2010
Resolved 15 November 2010
Resolution: Company sent copy of NTVRP Approval Letter via email. Vessel is approved to operate in Southeast Alaska and Prince William Sound.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 18 December 2008 Resolved
33U.S.C.1321(j)(5)(G)-The vessel owner/operator has not provided certification ensuring that response resources are capable of responding to the maximum extent practicable, to a worst case discharge. 33U.S.C.1321(j)(5)(D)(iv)-The NTVRP does not indicate that a spill management team tabletop exercise drill is conducted annually.
Due 18 January 2009
Resolved 8 May 2009
Resolution: Deficiencies fixed in NTVRP Control #05726, plan still deficient. Second deficiency letter sent 5/14/09.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 18 December 2008 Resolved
33U.S.C.1321(j)(5)(D)(iii)-The NTVRP does not identify a classified oil spill removal organization (OSRO) or provide an OSRO contract for the remote Guam and AK COTP zones 33U.S.C.1321(j)(5)(D)(iii)-The NTVRP does not identify a classified OSRO for the Honolulu, LA/Long Beach, Portland, San Diego, San Francisco COTP zones, and identifies an unclassified OSRO for the Puget Sound COTP zone. ,
Due 18 January 2009
Resolved 8 May 2009
Resolution: Deficiencies fixed NTVRP Control #05726 amended to reflect changes. Plan still deficient, second deficiency letter sent 5/14/09.

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.