Documentation record
Registered dimensions (L × B × D)65.0 ft × 19.0 ft × 8.3 ft
Registered tonnagegross 68 / net 54
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderYANK MARINE INC · TUCKAHOE NJ, UNITED STATES · built 2001
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portATLANTIC HIGHLANDS, NJ
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 2 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it54 - Simplified, Net Ton
68 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
22 March 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8332074
17 October 2025
Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8254552
27 February 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8084918
8 December 2023
COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7836421
30 November 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7831784
16 October 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7809024
11 August 2022
Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7530475
23 February 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7400632
11 May 2021
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7190525
19 June 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6974020
25 September 2019
Administrative Inspection · Hull Examination · Internal Structural Exam · Deficiency Check · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6820464
2 May 2019
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6674444
2 November 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6573209
27 April 2018
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6407849
10 January 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6335591
26 September 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6277298
17 August 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6247061
14 April 2017
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6124269
22 March 2016
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5837939
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 February 2025
Resolved
Flexible hose must be fabricated with an inner tube and a cover of synthetic rubber or other suitable materials reinforced with wire braid. MI observed corroded port and stbd side fuel line on main engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2025
Resolution: photos of new hoses recieved
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 December 2023
Resolved
The EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner. EPIRB battery has expired. EPIRB battery needs to be replaced. Vessel cannot operate beyond 3NM.
46 CFR 185.728 (b)
Action required: 705 - Other - as specified
Due 30 December 2023
Resolved 28 December 2023
Resolution: Vessel provided photographic evidence of battery replacement. Deficency has been resolved.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 November 2023
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 176.500(b)(1) and your Certificate of Inspection (COI) must be endorsed. Prior to carrying passengers, vessel must complete Annual COI inspection.
46 CFR 176.502
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2024
Resolved 8 December 2023
Resolution: Vessel completed COI renewal. Deficency has been resolved.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 August 2022
Resolved
Each buoyant apparatus must be capable of passing the tests in § 160.010-7. Materials not covered in this subpart must be of good quality and suitable for the purpose intended. Life Float webbing had deterirated and would not meet breaking strength requirement & retroreflective tape needed to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2022
Resolved 16 February 2023
Resolution: operator sent in photos of net replacements. photo attached in documents.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 February 2022
Resolved
A vessel that is exposed to salt water more than three months in any 12-month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel did not complete a USCG drydock Inspection by 30SEP21. Prior to conducting passenger operations, vessel must be reissued USCG Certificate of Inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 February 2022
Resolved 15 September 2022
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 2 November 2018
Resolved
Vsl is broadcasting Beam > than LOA, Vsl is broadcasting incomplete dimension information (AIS Antenna Position "X" equals 0) and Vsl is not broadcasting static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 2 May 2019
Resolution: AIS reads correctly
Operations/Management › Drills/Instruction › Flooding Mitigation
Issued 27 April 2018
Resolved
The vessel's master and crew are not familiar with any of the safety systems including the operation of the fixed firefighting and bilge manifold system. Vessel must be properly trained and prove crew competency to the Coast Guard. 46CFR185.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2018
Resolution: Proved proper operation of systems via drills.
Engineering › Bilge Water Management System › Manifold
Issued 27 April 2018
Resolved
Vessel must prove proper operation of the fixed bilge suction system. 46CFR176.500 (b)(1)/46CFR176.402
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2018
Resolution: Witnessed proper operation of system.
Documentation › Logs/Records › Drug Test Records
Issued 27 April 2018
Resolved
Vessel must provide a current crew list for all members enrolled and compliant with their DAPI program. Vessel must also provide a company policy. 46CFR16
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2018
Resolution: Provided updated crew list & company policy.
Communications › Radio Communications › Satellite Communications Capability
Issued 27 April 2018
Resolved
Vessel does not have the proper radio equipment for certificated route. Vessel is restricted to a limited coastwise route until proper radio equipment is provided. 47CFR80
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2018
Resolution: Vessel requested to reduce his route to no more than 20 NM from shore.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 27 April 2018
Resolved
Vessel has the following FCC violations and is restricted to no more than 1000 feet from shore until corrected 46CFR184.502:
1. Provide a valid FCC Safety Radio Certificate
2. Program MMSI number into VHF Radio
3. Correct all AIS errors as required by a previous deficiency
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2018
Resolution: Provided updated documentation from FCC inspector.
Lifesaving › Hand Flares › Quantity
Issued 27 April 2018
Resolved
Vessel must provide the proper number of distress signals for certificated route. 46CFR180.68
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2018
Resolution: Provided proper amount of flares.
Communications › Radio Communications › EPIRB
Issued 27 April 2018
Resolved
Vessel EPIRB disposable hydro link is expired. Vessel must provide a new hydro link. 46CFR185.740
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2018
Resolution: Vessel replaced hydrostatic link.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 27 April 2018
Resolved
One of four life float water lights are not operational. Vessel must provide a working water light for each life float. 46CFR180.175
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2018
Resolution: Light is in working order.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 22 March 2016
Resolved
CW01: Vessel is required to have two sources of electricity to power navigation equipment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 22 August 2016
Resolution: vessel has a second set of batteries
Electrical › Electric Generation Source (service) › Generator
Issued 22 March 2016
Resolved
Dual voltage generators: requires ground detection
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 22 August 2017
Resolution: MI received satisfatory photo documentation of required installed ground detection.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 22 March 2016
Resolved
DC panel on bridge has an opening where a breaker should be to prevent electric shock.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 22 August 2016
Resolution: Vessel installed panel blank.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 March 2016
Resolved
Electric solenoid in e/r is wired incorrectly by the negative being connected to engine.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 22 August 2016
Resolution: def was cleared by another inspector
Fire Fighting › Fire Pumps › Location
Issued 22 March 2016
Resolved
Fire pump is required to operate at the operating station (pilot house)
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 22 August 2016
Resolution: vessel installed remote switch on bridge
Navigation › Piloting/Steering › Marine Charts
Issued 22 March 2016
Resolved
Charts are required to be up to date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 22 August 2016
Resolution: vessel purchased up to date charts
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 22 March 2016
Resolved
Fire panel does not have power.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 22 August 2016
Resolution: Vessel found the breaker to turn power on to the fire detection panel