Inspection history · 26
2 February 2026
Administrative Inspection · Deficiency Check · Vessel Attendance · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8290899
10 July 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7941913
18 December 2023
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7837942
5 July 2023
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7696181
17 May 2022
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7452230
16 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7451912
13 November 2020
Initial Certification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7094728
20 May 2019
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6734516
2 November 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6573433
28 February 2017
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6096847
1 July 2016
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5925719
30 June 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5931804
9 January 2015
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5050577
9 September 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3846724
2 September 2010
Industry Initiated Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3844499
20 January 2009
Deficiency Check · Administration
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3397022
27 June 2002
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1638184
15 September 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1071399
6 November 1998
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 659112
4 November 1998
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 422361
4 November 1998
Uninspected Towing Vessel
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 804471
27 October 1997
Uninspected Towing Vessel
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1122201
13 August 1997
Uninspected Towing Vessel
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1121887
22 August 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1190745
18 August 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 93401
23 February 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 172124
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 February 2026
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following. All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Clean bilges to be free of oil and debris.
46 CFR 142.220 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2026
Resolved 3 June 2026
Resolution: Vessel cleaned and removed debris from bilge spaces.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 February 2026
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Repair all oil/fuel leaks from port and stbd engine along with associated piping/equipment.
46 CFR 143.220 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2026
Resolved 8 June 2026
Resolution: Repaired oil/fuel leaks on MDE and SSDG.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 February 2026
Resolved
Piping and machinery components that exceed 428 deg, including fitting, flanges, valves, manifolds and turbochargers, must be insulated. Exhaust lagging on Port and stbd engine missing lagging around the final flange going into the muffler and sections deteriorated and open exposing hot surface underneath. Insulate this surface.
46 CFR 143.220
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2026
Resolved 8 June 2026
Resolution: Installed exhaust lagging on all hot surfaces.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 2 February 2026
Resolved
Each remote fuel valve must be operable from a safe space outside the space where the valves located.The STBD and Port remote fuel valve was binding up restricting its movement. Modify the connection to prevent binding when the valve is being closed.
46 CFR 143.260
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2026
Resolved 13 May 2026
Resolution: Received photos of fuel valve replacement with a new shutting mechanism.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 2 February 2026
Resolved
An exposed hazard such as rotating machinery must be protected by a cover or guard. The generator belt guard was not installed on the running engine.
46 CFR 144.820
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2026
Resolved 13 May 2026
Resolution: Received photos of a new hazard guard installed on the generator.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 2 February 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Repair exhaust leaks on exhaust piping.
46 CFR 143.205 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2026
Resolved 3 June 2026
Resolution: Vessel rep made repairs to exhaust system on both MDE's and SSDG and no exhaust leaks were detected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 February 2026
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact and Electrical components that pose an electrical hazard must be in an enclosure. Electrical junction box under deck plate needs cover and wire nuts replaced with proper electrical connections. The terminal boards on port, starboard and fwd bulkhead need enclosure.
46 CFR 143.400
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2026
Resolved 13 May 2026
Resolution: Received photos of newly installed electrical protective devices throughout the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 February 2026
Resolved
Machinery systems must be designed and maintained to provide for safe operation of the towing vessel. The #2 hydraulic steering pump was inoperable. Make repairs and prover operation to the satisfaction of the MI.
46 CFR 143.205
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2026
Resolved 3 June 2026
Resolution: Vessel rep made satisfactory repairs to #2 hydraulic steering pump and is operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 February 2026
Resolved
Electrical systems must be designed and maintained to provide for the safe operations of the vessel and safety of the persons onboard. Electrical extension cord was found routed in the engine room. These cannot be used for permanent use and must be removed.
46 CFR 143.205
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2026
Resolved 3 June 2026
Resolution: Extension cord was removed from bilge spaces in the engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 February 2026
Resolved
Survival craft must be stowed in accordance with 199.130 of this chapter. Inflatable survival craft must have launching and inflating instructions posted in conspicuous places near the raft. The inflatable bag raft must be properly positioned and rigged to the vessel and launching instructions must be posted.
46 CFR 141.310
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2026
Resolved 8 June 2026
Resolution: Survial craft was stowed and attached to vessel and launching procedures posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 February 2026
Resolved
Pressure vessels must be externally examined annually. Air compressor onboard found heavily deteriorated and needs replaced.
46 CFR 143.300 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2026
Resolved 13 May 2026
Resolution: Received pictures of a newly installed air compressor with a new pressure vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 February 2026
Resolved
Machinery systems must be designed and maintained to provide for safe operation of the towing vessel. Steering mechanism on the aft deck, loose tie rod connections, elongated connection points, worn bushings and pins, rudder bearing has excessive play. Make repairs to the steering system to the satisfaction of the attending MI.
46 CFR 143.205
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2026
Resolved 8 June 2026
Resolution: Steering system was replaced/repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 2 February 2026
Resolved
The owner, managing operator, or master must ensure the strength of each component used for securing the towing vessel to the tow and for making up the tow adequate for its intended service. Both winches used to secure the tow are in poor condition and inoperable. Refurbish/repair both winches and prove operation to the attending MI.
46 CFR 140.801
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2026
Resolved 3 June 2026
Resolution: Both winches were replaced with new.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 February 2026
Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS). Fix inoperable navigation lights on mast.
46 CFR 140.720
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2026
Resolved 13 May 2026
Resolution: Received a picture of a newly installed masthead light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 February 2026
Resolved
Life jackets must be marked in block capitol letters with the name of the vessel and have an approved light and whistle attached to the front shoulder area of the jacket. The life jackets do not have a light or whistle attached.
46 CFR 141.340
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2026
Resolved 3 June 2026
Resolution: Vessel rep procured new lifejackets with lights and whistles and marked appropriately.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 February 2026
Resolved
Each towing vessel must be fitted with an industrial type first aid kit appropriate to the size of the crew. Medications were found expired as of 2024. Restock first aid kits with valid medications.
46 CFR 140.435
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2026
Resolved 3 June 2026
Resolution: First aid kit was restocked with new medication.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 2 February 2026
Resolved
Towing vessels must meet the communications requirements of 33 CFR part 26. The FCC radio authorization certificate is expired. Contact FCC representative to renew the certificate.
46 CFR 140.715 & 47 CFR 80.403
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2026
Resolved 13 May 2026
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2024
Resolved
Each remote fuel valve must be operable from a safe space outside the space where the valves located.
The STBD remote fuel valve was binding up restricting its movement. Modify the connection to prevent binding when the valve is being closed.
46 CFR 143.260
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2024
Resolved 10 July 2024
Resolution: Fuel shut off was repaired and op tested SAT.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 10 July 2024
Resolved
A navigation assessment for the intended route and operations must be completed prior to getting underway. The vessel did not have navigation assessments on board for use by the master.
46 CFR 140.635
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2024
Resolved 19 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2024
Resolved
Piping and machinery components that exceed 428 deg, including fitting, flanges, valves, manifolds and turbochargers, must be insulated.
Exhaust lagging on port and stbd engines are missing lagging around the final flange going into the muffler. Insulate this surface.
46 CFR 143.220
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2024
Resolved 19 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2024
Resolved
An exposed hazard such as rotating machinery must be protected by a cover or guard.
The generator belt guard was not installed on the running engine.
46 CFR 144.820
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 10 July 2024
Resolved 10 July 2024
Resolution: Guard was installed prior to MIs departing the inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 July 2023
Resolved
The remote fuel shutoff must be operable from a safe place outside the space where the valve is installed.
Marine inspector observed the stbd side fuel shutoff was not capable of closing from remote access point.
46 CFR 143.260 (d)
Action required: 705 - Other - as specified
Due 30 November 2023
Resolved 8 February 2024
Resolution: Remote fuel shut off addressed during dry dock period, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 May 2022
Resolved
(b) Day and night visual distress signals. Hand-held red flare distress signals, approved under approval series 160.021 or 160.121, and hand-held rocket-propelled parachute red flares, approved under approval series 160.036 or 160.136, are acceptable as both day and night signals.
Distress signals onboard did not have a CG approval.
46 CFR 141.375
Action required: 60 - Rectify deficiencies prior to movement
Due 26 May 2022
Resolved 26 May 2022
Resolution: Bought new approved flares.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 May 2022
Resolved
The design of the system and its installation on the towing vessel is certified and inspected by a registered professional engineer with experience in fire-detection system design, by a technician with qualifications as a National Institute for Certification in Engineering Technologies (NICET) level IV fire alarm engineering technician, or by an authorized classification society with equivalent experience, to comply with paragraphs (a)(1) through (6) of this section.
Vessel could not provide evidence of P.E. approval.
46 CFR 142.330
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 9 June 2022
Resolution: Fire detection system PE certificate onboard.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 May 2022
Resolved
The portable fire pump must be self-priming and power-driven, with: (1) A minimum capacity of at least 300 LPM (80 gpm) at a discharge gauge pressure of not less than 414 kPa (60 psi), measured at the pump discharge.
Portable pump's pressure gauge was not working.
46 CFR 142.325
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 9 June 2022
Resolution: Pressure gauge installed on fire pump.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 May 2022
Resolved
Each lifebuoy on a towing vessel must: (1) Be approved under approval series 160.050 or 160.150.
Approval series requires reflective tape. Reflective tape on forward house life buoy is worn and/or missing.
46 CFR 141.360
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 9 June 2022
Resolution: New ring life buoy installed onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 May 2022
Resolved
Towing vessel's survival craft must meet the functional requirements of paragraphs (b)(1) through (5) of this section. Functional requirements describe the objectives of the regulation. Survival craft must: (1) Be readily accessible; (2) Have an aggregate capacity sufficient to accommodate the total number of individuals onboard, as specified in paragraph (c) of this section; (3) Provide a means for sheltering its complement appropriate to the route; (4) Provide minimum equipment for survival if recovery time is expected to be greater than 24 hours; (c) Each life float and rigid buoyant apparatus must be fitted with a lifeline, pendants, a painter, and floating electric water light approved under approval series 161.010. Survival craft and stowage locations must be marked in accordance with the requirements of §§ 199.176 and 199.178 of this chapter.
Survival craft was not stowed correctly, missing all its equipment, and not properly marked.
46 CFR 141.325
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 9 June 2022
Resolution: Liferaft stowed correctly and possesses all required equipment.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 May 2022
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly.
Weather tight door on main deck's gasket completely wasted as well as steel combing.
46 CFR 144.320
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 14 July 2022
Resolution: The operator purchased a new weathertight door and the door was installed on the deckhouse.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 May 2022
Resolved
(a) The results of the inspections required by 33 CFR 164.76 must be documented in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel.
(b) A record of the type, size, and service of each towline, face wire, and spring line, used to make the towing vessel fast to her tow, must be available to the Coast Guard or third-party auditor for review. The following minimum information is required in the record: The dates when examinations were performed, the identification of each item of towing gear examined, and the names of the persons performing the inspection.
Vessel missing TVR.
46 CFR 140.820
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 9 June 2022
Resolution: Valid TVR onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 May 2022
Resolved
Station documents must be readily available to the licensed operator(s) on duty during the hours of service of the station and to authorized Commission employees upon request.
Vessel could not produce Radio Safety installation document.
47 CFR 80.403
Action required: 17 - Rectify deficiencies prior to departure
Due 26 May 2022
Resolved 9 June 2022
Resolution: Safety radio certificate onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 May 2022
Resolved
A COI may be suspended and withdrawn or revoked by the cognizant Officer in Charge, Marine Inspection at any time for noncompliance with the requirements of this subchapter.
Upon administrative review, the vessel is not permitted to operate outside of Routes and Conditions dictated in COI unless a new COI is issued for a Lakes, Bays, and Sounds route which is the designated route the vessel intends to operate on in Tampa Bay, FL.
46 CFR 136.215(c)
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2022
Resolved 26 May 2022
Resolution: USCG Sector St. Petersburg completed a COI on the vessel and issued a full term certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 May 2022
Resolved
A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date.
Upon administrative review, MI found vessel to be past due date for annual inspection. Vessel was required to complete an annual inspection by 18FEB21 and 18FEB2022. COI is no longer valid.
46 CFR 137.200
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2022
Resolved 26 May 2022
Resolution: USCG Sector St. Petersburg completed a COI on the vessel and issued a full term certificate.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 2 November 2018
Resolved
Vsl is not broadcasting dimension information (AIS Antenna Position ABCD values equals 0) and Vsl is not broadcasting static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 8 August 2019
Resolution: Vessel is no longer broadcasting AIS errors
Navigation
Issued 13 August 1997
Resolved
PROVIDE CURRENT CHART ONBOARD FOR AREA TRANSITING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Navigation
Issued 13 August 1997
Resolved
PROVIDE AN 8" BELL ONBOARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Documentation
Issued 13 August 1997
Resolved
PROVIDE VALID FCC RADIO LICENSE ONBOARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997