Records from 2006 to 2026. Most recent: inspection, 26 May 2026.
Documentation record
Registered dimensions (L × B × D)42.8 ft × 22.4 ft × 7.2 ft
Registered tonnagegross 69 / net 47
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDAKOTA CREEK INDUSTRIES · ANACORTES WA, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portJUNEAU, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 20 March 2026 · expires 30 April 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it69 - Regulatory (Subpart C or D), Gross Ton
47 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 9
26 May 2026
Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8382245
12 September 2025
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8229513
19 May 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8139364
12 September 2024
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7976678
28 August 2023
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7778230
15 June 2022
Administrative Inspection · MTSA Verification · Initial Certification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7472873
4 July 2015
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5176120
8 May 2012
Administration
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4780361
1 September 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2766104
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 September 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. The fuel supply line on the starboard main engine was found worn from an unsecured fuel line bracket.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 October 2025
Resolved 26 May 2026
Resolution: 4 fuel supply lines were replaced on engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 September 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The port generator was found with excessive oil in vicinity of rear main seal, clean area of excessive oil and determine source of oil leak and
repair.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 October 2025
Resolved 26 May 2026
Resolution: Rear main seal was replaced on generator.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 September 2025
Resolved
A fixed fire pump must be capable of: Being energized remotely from a safe place outside the engine room and at the pump. The fire pump does not have a remote means of start outside the engine room.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 October 2025
Resolved 26 May 2026
Resolution: Remote start installed on bridge. Tested sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 September 2025
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. The berthing space did not have a smoke detector.
Action required: 10 - Deficiency Rectified
Resolved 12 September 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 September 2025
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either: Automatic, battery-operated with a duration of no less than 2 hours. The emergency lighting in the engine room was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 September 2024
Resolved
The following systems must be equipped with gauges at the machinery location: auxiliary generator engine RPM. Auxilary generators do not have RPM gauges in machinery space, install RPM gauges.
46 CFR 143.230(c)(3)
Action required: 60 - Rectify deficiencies prior to movement
Due 12 October 2024
Resolved 19 May 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 September 2024
Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”.The machinery space water-tight hatch is not labeled, label watertight hatches.
46 CFR 144.160(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 15 October 2024
Resolution: Water-tight hatch labeled.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 September 2024
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. The starboard engine room distribution panel is missing a blank to protect from electrical hazard, install blank cover on panel.
46 CFR 143.400 (g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 15 October 2024
Resolution: Blanks installed on distribution panel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 September 2024
Resolved
Each navigation light must meet the technical standards of the applicable navigation rules. The stern towing
light was fitted with a household light bulb, install approved light bulb for stern towing light.
46 CFR 143.415(b)
33 CFR 183.810
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 15 October 2024
Resolution: Approved lightbulb installed and operational.