Records from 2001 to 2026. Most recent: inspection, 2 April 2026.
Inspection history · 49
2 April 2026
Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8356601
24 October 2025
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8258110
19 September 2024
Deficiency Check · PSC B · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8005543
31 August 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7781720
6 July 2023
Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7734593
28 June 2023
Explosive Handling Operation-Commercial
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7726359
19 October 2022
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7578203
23 July 2021
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7265332
9 April 2021
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7171682
17 March 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6928250
29 October 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6844704
22 September 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6817692
13 March 2019
ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6641555
24 September 2018
Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6547657
7 August 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6503214
24 June 2018
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6454250
28 November 2017
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6313768
14 November 2017
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6306731
4 October 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6280881
21 June 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6182170
1 May 2017
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6136130
8 April 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6119576
13 May 2016
ISPS II Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5873536
1 March 2016
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5824615
3 March 2014
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4809649
30 January 2012
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4234229
29 July 2011
ISPS III Exam · Spot Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4098258
29 January 2011
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3935412
2 April 2009
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3444991
27 March 2009
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3441545
15 January 2009
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3394556
8 January 2009
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3390983
5 March 2008
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3174522
15 October 2007
NPV Safety Exam · ISPS III Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3080184
11 January 2007
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2854136
21 October 2006
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2804983
15 May 2006
ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2650494
23 August 2005
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2471872
24 June 2005
MARPOL Annex I Examination · ISPS III Exam · Ballast Water Examination · NPV Safety Exam · MARPOL Annex V Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2396959
26 January 2005
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2282599
13 October 2004
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2219750
30 July 2004
ISPS II Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2145310
25 March 2004
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2031296
19 May 2003
Ballast Water Examination · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1795482
30 November 2002
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1712385
27 November 2002
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1713644
13 February 2002
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1485117
10 March 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 287914
10 January 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 285835
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 September 2024
Resolved
Means shall be provided to close all opening which may admit air to or allow gas to escape from a protected space. PSCO ovserved fire-caps missing from drainpipes on cargo hold hatches.
74 SOLAS(01) II-2/5.1.4
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2024
Resolved 11 October 2024
Resolution: Vessel sent evidence of firecap delivery for all cargo hold hatch drainpipes.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 22 September 2019
Resolved
(01)(01108)(74 SOLAS 04) AN INTERNATIONAL LOAD LINE CERTIFICATE SHALL BE ISSUED TO EVERY SHIP WHICH HAS BEEN SURVEYED AND MARKED IN ACCORDANCE WITH THE PRESENT CONVENTION. VESSEL HAS TIMBER LOAD LINE WHICH IS NOT IDENTIFIED ON SHIP'S CERTIFICATE. LOAD LINE APPEARS TO HAVE BEEN RECENTLY PAINTED BECAUSE LOAD LINE IS STILL PERMANENTLY MARKED. MASTER INDICATES VESSEL WILL NEVER CARRY TIMBER.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 October 2019
Resolution: TIMBER LOAD LINE PAINTED
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 September 2019
Resolved
(02)(13199)(74 SOLAS 04) THE MACHINERY...SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. HAND PUMP FOR EDG LOUVERS HAS HYDRAULIC LEAD. HYDRAULIC FLUID COLLECTING IN VICINITY. RESERVOIR AT MINIMUM FILL LINE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2019
Resolved 29 October 2019
Resolution: LEAKING HAND PUMP FOR EDG LOUVERS WAS REPLACED BY THE CREW WITH A SPARE ONE AND EXAMINED BY CLASS SURVEYOR WITH SATISFACTORY RESULTS: NO LEAKS WERE NOTED. HYDRAULKIC RESERVOUR FOUND WITH OIL LEVEL WITHIN RANGE.
Fire Fighting › International Shore Connection › Bolts
Issued 4 October 2017
Resolved
10c, 74 SOLAS (01) II-2/19.1
Ships of 500 GT and upwards shall be provided with at least one international shore connection. International shore connection was inaccessible and not available for immediate use due to storage container being painted shut.
Condition: Improper/Lack of Maintenance
Due 4 October 2017
Resolved 4 October 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 4 October 2017
Resolved
50ac, 74 SOLAS (04) II-1/45.1.3
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Multiple deck lights had water intrusion and visibly chafed cable.
Action required: 705 - Other - as specified
Due 4 November 2017
Resolved 14 November 2017
Resolution: Received Lloyds Register Class report attesting to the satisfaction condition of deck lights and cabling.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 4 October 2017
Resolved
16c, 74 SOLAS (01) II-2/47.1
The fire resistance of doors shall... be equivalent to that of the division in which they are fitted. Self closing doors on the poop deck, upper deck, and galley failed to latch as required.
06OCT2017 2/3 doors fixed.
Action required: 705 - Other - as specified
Due 18 October 2017
Resolved 28 November 2017
Resolution: Verified proper operation of all self closing doors and latching mechanisms.
Electrical › Lighting (service) › Lighting Fixture
Issued 4 October 2017
Resolved
50ac, 74 SOLAS (04) II-1/30.1
Means for indicating that the motors of electric and electrohydraulic steering gear are running shall be installed on the navigation bridge and at a suitable main machinery control position. Number 2 steering pump indicator was not operational on the bridge.
06OCT2017 Deficiency corrected.
Action required: 705 - Other - as specified
Due 4 November 2017
Resolved 14 November 2017
Resolution: Received Lloyds Register Class report attesting to the satisfactory condition of Number 2 steering pump indicator on the bridge.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 8 April 2017
Resolved
1541-Ships shall be fitted with an indicator showing the rudder angle from the conning position. during steering tests, indicators at conning positions port/starboard bridge wings and main were off by more that 3 degrees when beyond 20 degrees to the port side. notify all pilots on board of error until rectified. Solas74(14cons) V/19.2.2.5.4(MSC Circular 982)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 1 May 2017
Resolution: Rudder angle indicator was fixed and tested satisfactory.
Operations/Management › Ballast Water Managment › Submission of Report
Issued 23 August 2005
Resolved
Vessel did not submit Ballast Water Reporting Form for COTP Philadelphia, but did for Houston. Captain was unaware that a reporting form needs to be submitted before every US port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2005
Resolution: Captain submitted Reporting Form while USCG team was onboard
Engineering › Diesel Engine (propulsion-electric) › Governor
Issued 30 November 2002
Resolved
VESSEL EXPERIENCED A MALFUNCTION OF MAIN PROPULSION. CLASS TO ATTEND AND SUBMIT REPORT TO COTP BALTIMORE PRIOR TO DEPARTURE PORT OF BALTIMORE.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 December 2002
Resolved 3 December 2002
Resolution: FITTED MAIN ENGINE WITH A SPARE WOODWARD GOVERNOR.