Records from 2001 to 2026. Most recent: inspection, 20 July 2026.
Inspection history · 44
20 July 2026
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8442399
1 December 2025
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8269638
31 May 2024
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7924156
30 May 2024
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7922969
18 November 2022
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7596709
7 September 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7553299
7 September 2022
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7553342
14 May 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6953286
5 April 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6935571
19 August 2019
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6787694
16 April 2019
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6663349
6 March 2019
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6635807
2 February 2019
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6618967
25 July 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6490064
20 March 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6374991
22 January 2018
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6338020
2 August 2017
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6228129
25 June 2017
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6184552
21 June 2017
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6182583
20 November 2016
PII Safety Exam · ISPS III Exam · In-Service Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6044486
22 August 2016
ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5979524
1 March 2016
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5824615
19 February 2016
ISPS II Exam · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5818529
29 December 2011
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4215308
3 September 2011
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4134555
10 December 2010
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3908014
14 September 2010
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3849421
23 September 2008
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3331114
28 November 2007
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3106053
23 September 2006
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2785180
6 June 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2683154
16 May 2006
ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2650383
11 February 2006
ISPS III Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2583431
19 September 2005
MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2496101
18 August 2005
ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2466598
26 April 2005
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2342959
10 February 2005
Random ISPS/MTSA/PSC
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2289749
3 December 2004
ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2253024
12 July 2004
ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2130011
8 May 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1788921
12 April 2002
Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1603939
7 March 2002
Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1492095
28 December 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1474348
20 April 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 289543
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 20 July 2026
No resolution recorded
1) "No person may cause a vessel to enter or get underway on the navigable waters of the United States unless no more than 12 hours before entering or getting underway the following equipment has been tested: (1) primary and secondary steering gear . . . (2) all internal vessel control communications and . . . alarms. (3) stand by or emergency generator . . . (4) storage batteries for emergency lighting and power systems in vessel control and propulsion machinery spaces. (5) main propulsion machinery, ahead and astern." CITE: 33CFR164.25(a)
Pre-arrival checks and tests were conducted after entry into US navigable waters.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 August 2026 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 6 March 2019
Resolved
The rescue boat shall be stowed in a state of continuous readiness for launching. Rescue boat did not immediately start due to disconnected spark plug cable. Crew had to determine root cause of engine failure.
74SOLAS14CONS.CHIII/REG 14.1
Action required: 10 - Deficiency Rectified
Resolved 16 April 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 March 2019
Resolved
Where they pass through accommodation spaces or spaces containing combustible materials, each exhaust duct shall be fitted with a grease trap readily removable for cleaning. Galley range was missing 01 grease trap.
74SOLAS01CONSII-2/REG 16.7.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 April 2019
Resolution: PSCE INSPECTED GALLY RANGE AND VESSEL HAS REPLACED THE MISSING GREASE TRAP.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 March 2019
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. Heated oil line used to heat secondary water heater located in stern port side of engine room has approximately 1 foot of missing lagging as well as approximately 3 feet of oil soaked lagging.
74SOLAS04CONSCHII-1/REG 26.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 April 2019
Resolution: PSCE EXAMINED AND FOUND THAT THE VESSEL HAD REPLACED THE MISSINIG/OIL SOAKED LAGGING.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 July 2018
Resolved
0750 - IN A SHIP IN WHICH OIL, FUEL IS USED THE UTILIZATION OF THE OIL FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. PSCO DISCOVERED PORT SIDE FED E.R. HAS WHAT APPEARS TO BE A LARGE HFD PIPE LEAKING INTO A MAKESHIFT DRIP PAN PLUS OIL SOAKED LAGGING CREATING A FIRE HAZARD. ADDITIONALLY, HFO CALVE LABELED “FROM HFO PUMP DELIVERY FROM BUNKER ST.” HAS LEAKED HFO WITH OIL SOAKED LAGGING. SOLAS 74 (2001 Cons.) II-2/15.2 (17ac)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2018
Resolution: RECEIVED CLASS REPORT.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 July 2018
Resolved
0599 - THE CONDITION OF THE SHIP SHALL BE MAINTAINED TO ENSURE THE SHIP WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. PSCO DISCOVERED MAIN ENGINE HEAD WAS SECURED IN THE FRONT OF BOILER WITH TIE DOWNS BLOCKING ESCAPE ROUTES PLUS CREATING TRIPPING HAZARD. ADDITIONALLY, VARIOUS LOCATIONS IN R.R. HAVE EGRESS ROUTES BLOCKED WITH VARIOUS LARGE ITEMS. SOLAS 74 (2014 Cons.) I/11 (17ac)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2018
Resolution: RECEIVED CLASS REPORT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 July 2018
Resolved
0599 - THE CONDITION OF THE SHIP SHALL BE MAINTAINED TO ENSURE THAT THE SHIP WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. PSCO DISCOVERED SHIPS HEEL AIR COMPENSATOR HAS WOOD BLOCKING ACCESS TO BACK COVERS. SOLAS 74 (2014 Cons.) I/11 (10c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 July 2018
Resolved 25 July 2018
Resolution: Corrected on the spot
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 25 July 2018
Resolved
0750 - IN A SHIP IN WHICH OIL IS USED, THE UTILIZATION OF THE OIL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ONBOARD. PSCO DISCOVERED STEERING ROOM STBD SIDE LEAKING THERMAL OIL VALVES AND OIL SOAKED LAGGING. SOLAS 74 (2001 Cons.) II-2/15.4 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 July 2018
Resolved 25 July 2018
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 25 July 2018
Resolved
0750 - PROVISIONED SHALL BE MADE TO PREVENT OVERPRESSURE IN AY PART OF THE OIL FUEL SYSTEM. PSCO DISCOVERED THAT THE MDO LINE TO THE FILTER RELIEF VALVE TO OVERFLOW TANK WAS GAGGED. SOLAS 74 (2001 Cons.) 15.2.7 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 July 2018
Resolved 25 July 2018
Resolution: Corrected on the spot.
Engineering › Fuel Oil Service System › Ventilation
Issued 25 June 2017
Resolved
1400 - AFTER ANY SURVEY OF THE SHIP HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN STRUCTURAL ARRANGEMENTS, MACHINERY OR EQUIPMENT. OBSERVED PORTABLE FAN COOLING PURIFIER CONTROL BOX. 74SOLAS(2014CONS.)I/11B 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 July 2017
Resolved 2 August 2017
Resolution: Received class report attesting to repairs.
Electrical › Electrical Distribution System (service) › Cable
Issued 25 June 2017
Resolved
CABLES AND WIRING SHALL BE INSTALLED AND SUPPORTED IN SUCH A MANNER AS TO AVOID CHAFING OR OTHER DAMAGE. OBSERVED SPEED LOG WIRE WITH SIGNIFICANT INSULATION SURROUNDING IT. 74SOLAS(2004CONS.)II-1/45.5.5 40AC
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 July 2017
Resolved 2 August 2017
Resolution: Received class report attesting to proper repairs.
Navigation › Collision/Grounding Avoidance › Radar
Issued 14 September 2010
Resolved
1530 - Navigation - a 9GHz X-radar must be fitted to determine and display the range and bearing of radar transponders and of other surface craft. obstruction, buoys, shorelines, and navigational marks to asist in navigation and in collision avoidance. X-Band Radar inoperable. 74 Solas (2010 cons) Ch.V Reg 19.2.3.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2010
Resolution: Service Technician Report attested to the repairs and operation of the X-Band Radar. Refer to documentation Section for further details.
Documentation
Issued 20 April 2001
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 20 April 2001
Resolved 26 April 2001