Records from 2003 to 2026. Most recent: inspection, 19 May 2026.
Documentation record
Registered dimensions (L × B × D)57.0 ft × 20.0 ft × 7.0 ft
Registered tonnagegross 89 / net 60
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPOWERS-CARR EQUIPMENT CO. · TACOMA, WA, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 6 September 2025 · expires 30 September 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it89 - Regulatory (Subpart C or D), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 13
19 May 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8358781
12 May 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8131326
4 April 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8105289
20 May 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7915876
7 April 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7664737
18 February 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7398514
3 December 2021
Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7405414
16 September 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4985820
24 April 2014
Administration · Industry Initiated Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4843116
12 February 2009
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3416507
9 May 2005
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2359280
6 August 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1868283
31 July 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1867649
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2026
Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110, unless the towing vessel is limited to daytime operation, in which case no floating electric water light is required. MI observed only one life buoy with a light attached. O/o must obtain a water light for vessel's second life buoy.
46 CFR 141.360(c)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 16 June 2026
Resolution: Received photographic evidence of new waterlight attached to life buoy on board vessel.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 7 April 2023
Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced. Test and examination procedures must be in accordance with manufacturer's instructions. Rudder stock, tiller, and associated pins/connections are severely worn, corroded, and loose. Repair/Renew these components as originally designed.
46 CFR 143.245(a) and 46 CFR Table 143.245(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2023
Resolved 21 April 2023
Resolution: Witnessed operation of rebuild steering gear system. all sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 April 2023
Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the COLREGS or 33 CFR 84 as appropriate to its area of operation. Navigation lights on board had unapproved light bulbs(horizonal filament) installed in each housing. 46 CFR 140.720
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 21 April 2023
Resolution: Vessel has replaced all bulbs with proper ones.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 7 April 2023
Resolved
No person shall conduct an oil or hazardous material transfer operation unless the discharge containment drain and scupper is closed by the mechanical means. Fuel tank vent containment did not have mechanical means of closure. 33 CFR 156.120(o)
Condition: Improper Installation
Action required: 703 - Prior to bunkering operations
Due 18 May 2023
Resolved 21 April 2023
Resolution: Witnessed dclosure device installed.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 7 April 2023
Resolved
Each towing vessel must be operated in compliance with: (1) Applicable sections of the Federal Water Pollution Control Act, including section 311 of the Federal Water Pollution Control Act, as amended(33 U.S.C. 1321). Steering gear system enclosure is not sealed thus allowing rainwater to accumulate and mix with hydraulic fluid and potentially discharge overboard. 46 CFR 140.655(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2023
Resolved 21 April 2023
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 7 April 2023
Resolved
The master must ensure·that all hatches, doors, and
other openings designed to be watertight or weather-
tight function properly. Forward fuel fill on stbd side not properly secured to the deck. 46 CFR 140.610 (b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2023
Resolved 21 April 2023
Resolution: Repaired area. All sat.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 April 2023
Resolved
Each towing vessel must be maintained and operated so as
to minimize fire hazards and to ensure all bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Void aft of engine room has an
accumulation of oil. 46 CFR 142.220
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2023
Resolved 21 April 2023
Resolution: Aft void cleaned.