Inspection history · 97
10 December 2025
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8281575
9 December 2025
DAPI Audit
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8282599
12 June 2025
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8158782
13 January 2025
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8062921
11 December 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7831431
11 December 2023
DAPI Audit
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7838272
13 October 2022
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7576577
12 September 2022
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7560463
28 September 2021
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7322104
27 July 2021
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7269456
27 May 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6968081
15 January 2019
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6625349
14 December 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6597961
15 November 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6581571
7 November 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6576113
6 June 2018
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6436354
6 June 2018
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6437235
21 May 2018
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6419832
22 April 2017
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6131421
10 May 2016
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5873816
17 February 2016
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5817190
24 May 2013
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4609580
1 May 2013
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4585443
3 April 2013
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4564531
2 February 2013
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4528960
13 December 2012
Industry Initiated Exam · MARPOL
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4504359
26 August 2008
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3321092
26 March 2008
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3174676
1 March 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3161438
24 February 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3158727
11 January 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3130286
19 September 2007
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3099166
1 July 2007
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2981774
24 June 2007
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2976919
9 April 2007
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2908649
22 November 2006
Type not recorded
No type recorded · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2829802
6 November 2006
Type not recorded
No type recorded · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2832209
1 February 2006
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2577268
1 February 2006
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2577345
17 January 2006
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2571699
20 December 2005
Type not recorded
No type recorded · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2611100
15 November 2005
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2535035
12 October 2005
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2520331
5 May 2005
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2350070
22 April 2005
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2342083
22 April 2005
Uninspected Other
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2342239
22 April 2005
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2377384
24 December 2004
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2307299
18 October 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2223778
9 September 2004
Type not recorded
No type recorded · Station Gulfport · USCG Heartland District (CGD-H) · Activity 2212491
27 July 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2155958
7 July 2004
Type not recorded
No type recorded · USCG Heartland District (dpb) · USCG Heartland District (CGD-H) · Activity 2126965
1 June 2004
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2087771
27 January 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2025672
30 March 2003
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1774325
4 August 2002
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1660889
8 June 2002
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1632068
31 May 2002
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1626876
22 April 2002
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1616265
17 December 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1477395
7 November 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 17412
10 September 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 24118
26 April 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 131215
14 April 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 44315
19 March 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 48312
27 June 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 161312
5 June 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 43186
31 May 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 32245
11 March 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 19795
24 February 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 18159
20 February 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 73588
8 December 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 14287
25 August 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 127177
27 June 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 187530
11 December 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 411538
16 November 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 133133
24 October 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 154513
10 October 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 98689
20 August 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 75914
11 August 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 157792
16 June 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 4859
2 June 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 14675
17 April 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 76107
16 April 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 40762
1 April 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 45120
7 March 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 155273
29 February 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 71683
26 January 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 75602
24 January 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 155121
23 January 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 143907
22 April 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 101145
7 December 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 167698
19 October 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 104187
11 May 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 116
3 March 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 23409
23 April 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 75450
14 April 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 54361
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 December 2025
Resolved
Means must be provided for stopping each fan in a ventilation system for machinery spaces and for closing. Each doorway, ventilator, and annular space around funnels and other openings into such spaces. No means to close the ventilation system provided. Provide means to close ventilation to machinery space. Close opening aft upper engine room bulkhead wire run.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2026
Resolution: Porvided objective evidence of vent closures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 December 2025
Resolved
Bilge alarm must be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm; if the alarm at the operating station is a summary alarm, the specific alarm condition must be indicated at the machinery or bilge location. No visual alarm at operating station. No visual or audible alarm at machinery space. Provide visual/audio indicator for bilge alarm at operating station and machinery space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 February 2026
Resolution: Provided objective evidence of repairs.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 December 2025
Resolved
E-lighting must be provided for all internal crew working and living areas. Provide e-light at upper Qtrs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 February 2026
Resolution: Provided objective evidence of repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 December 2025
Resolved
Each towing vessel must carry at least one appropriately-sized lifejacket, approved under approval series 160.002, 160.005, 160.055, 160.155, 160.176, or 160.255 for each person on board. Short 2 lifejackets. Provide 2 lifejackets with name, light, whistle.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 February 2026
Resolution: Provided required life jackets with attachements.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 December 2025
Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage. Rose-Point chart plotter inoperable. Provide up to date charts or chart plotter.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 February 2026
Resolution: Provided objective evidence of charts.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 10 December 2025
Resolved
Alcohol testing must be conducted on each individual engaged or employed on board the vessel who is directly involved in the SMI. The alcohol testing of each individual must be conducted within 2 hours of when the SMI occurred, unless precluded by safety concerns directly related to the incident. No means to conduct alcohol testing within 2 hours available. Provide means to test for alcohol.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 February 2026
Resolution: Provided objective evidence of test strips.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 December 2025
Resolved
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under § 67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. COD expired, provide valid COD.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 February 2026
Resolution: Provided objective evidence of COD.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 December 2025
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. 2 rail stanchions on stbd side wasted, repair wasted stanchions.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 February 2026
Resolution: Provided objective evidence of repairs.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 June 2025
Resolved
Fire hazards must be minimized. Vessel has oil accumulation in the eninge room bilge.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 September 2025
Resolution: Received objective evidence of oil removal.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 June 2025
Resolved
Fire hazards shall be minimized. Fuel piping has small leak. Make repairs to the satisfaction of CG MI.
Action required: 10 - Deficiency Rectified
Resolved 12 June 2025
Resolution: Fuel leak repaired on the spot.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 January 2025
Resolved
Alarms must be visible and audible at each operating station and have a means to test actuation at each operating station. The alarm panel was inoperable at the time of inspection due to disruption in alarm panel wire circuits. Replace or repair the wiring and provide evidence of proper alarm testing to the satisfaction of the local Coast Guard Marine Inspector.
46 CFR 143.230
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2025
Resolution: Alarms repaired and operable.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 January 2025
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and ensure that all bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. The bilges beneath the engine contained oily water. Pump oily mixture in the bilge to the satisfaction of the attending marine inspector.
46 CFR 142.220(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2025
Resolution: Bilges were made free of oily water.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 December 2023
Resolved
Vessel must have fire hoses. The hose must be a lined commercial fire hose 15 meters (50 feet) in length, at least 40 millimeters (1.5 inches) in diameter, and fitted with a nozzle made of corrosion-resistant material capable of providing a solid stream and a spray pattern. One fire hose on the starboard side roptured. Replace in kind.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2024
Resolved 5 January 2024
Resolution: Replaced fire hose in kind.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 11 December 2023
Resolved
Stop any mechanical ventilation system for the engine room and effectively seal all natural openings to the space to prevent leakage of the extinguishing agent. Not able to seal all openings to the space. Maka arrangements to seal openings to engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2024
Resolved 5 January 2024
Resolution: Provided means to close air intakes for engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 December 2023
Resolved
Pressure vessel relief valves Twice every 5 years, with no more than 3 years elapsing since last test. Not able to test, no records available. Provide documentation of test.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2024
Resolved 5 January 2024
Resolution: Third party tested PRV.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 December 2023
Resolved
Expired alcohol swabs
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 13 December 2023
Resolved 12 December 2023
Resolution: new swabs put onboard
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 July 2021
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the associated fleet that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 October 2021
Resolved 28 September 2021
Resolution: Inspection status changed from M to SubCh C. Worksite Exclusion Vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 November 2018
Resolved
The inspection team identified excessive water ingress through the starboard side shaft packing gland that was not immediately reported to the company as per the safety management system's reporting procedures, creating a serious substandard condition not being pro-actively managed by the Company, vessel owner, and/or operator.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 15 November 2018
Resolved 27 November 2018
Resolution: Shaft packing gland was adjusted to 1 drop every 3 seconds.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 15 November 2018
Resolved
The inspection team identified multiple alarms within the Pilothouse fire control panel, as well as identified 2 of 4 engine room fire detectors were disassembled and incapable of detecting engine room fires, creating a serious substandard condition found not being pro-actively managed by the Company, vessel owner, and/or operator.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2018
Resolved 18 December 2018
Resolution: Witnessed op test of fire control panel.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 15 November 2018
Resolved
Plastic zip tie was affixed to the pull assembly of the remote operated fuel shutoff valve for the port side generator preventing the immediate shutdown in case of emergency, creating a serious substandard condition not being proactively managed by the Company, vessel owner, and/or operator.
Condition: Improper Installation
Action required: 30 - Ship detained
Due 15 November 2018
Resolved 27 November 2018
Resolution: Zip tie was removed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 November 2018
Resolved
Identified 2 foot of water within all starboard side void spaces causing an estimated 2-4% list, creating a serious substandard condition not being proactively managed by the Company, vessel owner, and/or operator.
Action required: 30 - Ship detained
Due 15 November 2018
Resolved 27 November 2018
Resolution: All water was removed from wing voids.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 November 2018
Resolved
Inspection team observed numerous steering system leaks. Leaks originated from hose fittings and valve assemblies. Hydraulic fluid is collecting in the installed containment and spilling over the sides, creating a hazardous condition.
Action required: 30 - Ship detained
Due 15 November 2018
Resolved 18 December 2018
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 15 November 2018
Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. The navigation assessment must incorporate the requirements of pilothouse resource management of 46 CFR 140.640, assess operational risks, and anticipate and manage workload demands. Navigational assessments are not being completed as required. Last recorded assessment/voyage plan was dated 9NOV2018.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 15 November 2018
Resolved 18 December 2018
Resolution: Discussed pre u/w checks and witnessed master conduct.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 November 2018
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Determine root cause failure of port generator. Generator tripped off-line without indication, resulting in loss of propulsion.
Action required: 30 - Ship detained
Due 15 November 2018
Resolved 18 December 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 November 2018
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Determine root cause of starboard generator failure. Upon failure of port generator and loss of propulsion, starboard generator could not be brought on line to supply power to the vessel.
Action required: 30 - Ship detained
Due 15 November 2018
Resolved 18 December 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 November 2018
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing
vessel and safety of persons on board under normal and emergency conditions. Identified the port generator leaking exhaust on the discharge side of the turbo.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2018
Resolved 18 December 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 November 2018
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing
vessel and safety of persons on board under normal and emergency conditions. Identified leakage of the rear main seal of the port generator.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2018
Resolved 18 December 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 November 2018
Resolved
Piping and machinery components that exceed 428 °F, plus fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. No insulation found on the port generator turbo.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2018
Resolved 18 December 2018
Resolution: insulation installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 November 2018
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing
vessel and safety of persons on board under normal and emergency conditions. Identified no interlock installed within electrical switchboard to prevent port and starboard generators from concurrent operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2018
Resolved 18 December 2018
Resolution: Installed mechanical interlock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 November 2018
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing
vessel and safety of persons on board under normal and emergency conditions. Identified the electrical switchboard #2 voltmeter is non operational.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2018
Resolved 18 December 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 November 2018
Resolved
The fuel shut off valve must be operable from a safe place outside the space where the valve is installed. Identified the starboard generator fuel shut off valve retained excessive slack, preventing the immediate shutdown in case of an emergency.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2018
Resolved 18 December 2018
Resolution: Shutoff tightened, witnessed op test
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 November 2018
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing
vessel and safety of persons on board under normal and emergency conditions. Identified bungee cords supporting starboard generator air filter housing, instead of permanent support latches.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2018
Resolved 18 December 2018
Resolution: Metal bands installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 November 2018
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing
vessel and safety of persons onboard under normal and emergency conditions. Identified oil leak on starboard main diesel engine head gasket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2018
Resolved 18 December 2018
Resolution: Replaced Head gasket
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 November 2018
Resolved
It is the responsibility of the crew to report unsafe conditions to the master or officer in charge of a
navigational watch and take effective action to prevent accidents. Identified the on board hot water heater is not secured to the deck or bulkheads.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2018
Resolved 18 December 2018
Resolution: Installed metal bands
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 November 2018
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weathertight
function properly. Identified the starboard main deck watertight door leading to the engine room is difficult to open, also creating a potential hazard for egress.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2018
Resolved 18 December 2018
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 15 November 2018
Resolved
A towing vessel must be maintained and operated so the
watertight integrity and stability of the vessel are not compromised. Identified two 1" x 1" rusted holes found painted over penetrating the bulkhead, located on the exterior starboard side superstructure of the galley.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2018
Resolved 18 December 2018
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 November 2018
Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110. Identified port forward and aft ring buoys installed with lifejacket lights instead of approved ring buoy water lights.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2018
Resolved 18 December 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 November 2018
Resolved
A towing vessel must be maintained and operated so the
watertight integrity and stability of the vessel are not compromised. Identified the engine room has unnecessary amount of water in the bilge, remove from the vessel
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2018
Resolved 18 December 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 November 2018
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Electrical switchboard and panel not properly labeled.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2018
Resolved 18 December 2018
Resolution: Labeled to indicate systems.
Construction/Loadline › Hull › Hull Plating
Issued 22 April 2005
Resolved
Found 3 small holes in the starboard midship hull plating in the engine room. Holes are below the water line and are leaking water into the bilges. Company was advised to have the holes repaired upon return of the vessel to their Alabama facility.
Condition: Improper/Lack of Maintenance
Due 22 May 2005
Resolved 15 June 2005