HERITAGE is a 1982 towing vessel. The Coast Guard has recorded 22 inspections since 1992, most recently in October 2025, along with 14 deficiencies.

Records from 1992 to 2025. Most recent: inspection, 10 October 2025.

Built
1982
Last inspected
10 October 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDF2035
211068
Flag
UNITED STATES
Maury page id
psix-211068

Inspections, by type

…with no type recorded13
Years with a record 14 calendar years (1992–2025)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)60.0 ft × 22.1 ft × 7.5 ft
Registered tonnagegross 82 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderECONOMY BARGE REPAIR INC · PROCTORVILLE, OH, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portCINCINNATI, OH
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 May 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it82 - Simplified, Gross Ton
66 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MARK M Towing Vessel · MISLE 75799 · 28 May 1996 · activity 140765ING 712 Freight Barge · MISLE 156114 · 28 May 1996 · activity 140765ING 829 Freight Barge · MISLE 171195 · 28 May 1996 · activity 140765MEM8181 Freight Barge · MISLE 197441 · 28 May 1996 · activity 140765OR 4798 Freight Barge · MISLE 321115 · 28 May 1996 · activity 140765

Inspection history · 22

10 October 2025 COI Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 8250422
13 August 2025 Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 8207202
27 May 2021 Examination of Repairs
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7208523
20 October 2020 Initial Certification · Administrative Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7081299
7 March 2016 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5830541
17 November 2015 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5766135
21 February 2013 Industry Initiated Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4537436
15 March 2012 DAPI Audit
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4389216
6 December 2010 DAPI Audit
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3904896
6 December 2010 DAPI Audit
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3904904
14 January 2009 Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3394192
14 January 2009 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3394820
14 January 2009 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3395327
19 August 2008 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3304127
3 April 2008 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3180541
31 July 1997 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 756369
15 July 1997 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 198396
23 June 1997 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 106909
28 May 1996 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 140765
18 April 1994 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 179418
10 February 1994 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 111412
23 June 1992 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 121004

Deficiency record · 14

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 August 2025 Resolved
All fuel filters need to be put back to original manufacturers specifications (metal impingement bowls missing).
Action required: 705 - Other - as specified
Resolved 15 January 2026
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 August 2025 Resolved
Engine room bilge alarms need to be tested & crew familiar with testing
Action required: 705 - Other - as specified
Resolved 15 January 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 August 2025 Resolved
All emergency-stop pull cables need to be properly installed & tested
Action required: 705 - Other - as specified
Resolved 15 January 2026
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 August 2025 Resolved
Engine room emergency lighting needs to be repaired & tested
Action required: 705 - Other - as specified
Resolved 9 October 2025
Resolution: Engine room lighting sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 August 2025 Resolved
Deck washdown pump needs to be repaired (electrical)
Action required: 705 - Other - as specified
Resolved 9 October 2025
Resolution: Deck washdown pump sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 August 2025 Resolved
Verify cable size and application for both main engines starting batteries
Action required: 705 - Other - as specified
Resolved 9 October 2025
Resolution: Cable size and application for both M/E starting batteries verified.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 13 August 2025 Resolved
#1 main engine needs harmonic balancer guard installed
Action required: 705 - Other - as specified
Resolved 15 January 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 August 2025 Resolved
Separate type 1 and type 3 lifejackets
Action required: 705 - Other - as specified
Resolved 9 September 2025
Resolution: Lifejackets properly stowed
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 August 2025 Resolved
Crew needs to understand how to properly configure & operate AIS
Action required: 705 - Other - as specified
Resolved 9 September 2025
Resolution: Crew operation/configuration of AIS sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 October 2020 Resolved
Both main engines and generators did not have proper installed lagging on dry exhaust
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2020
Resolved 22 October 2020
Resolution: lagging was installed
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 October 2020 Resolved
Portable fire pump was not on board, hose nozzle and foot valve on board.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2020
Resolved 22 October 2020
Resolution: Conducted satisfaction operational test of portable fire pump with associated hoses and nozzle.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 20 October 2020 Resolved
No documentation of fire drill since 2018, crew admitted they have not done a fire drill in years.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2020
Resolved 22 October 2020
Resolution: Conducted fire drill with crew, improperly documented.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 October 2020 Resolved
Install flame shields on all fuel filters and engine room in accordance with manufactures design approval. Rakor plastic fuel bowl without flame shield.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2020
Resolved 18 December 2020
Resolution: Installed
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 20 October 2020 Resolved
Vessel could not provide the chart indicating inches of measurement of fuel to total in tank, total of six tanks onboard vessel 8500 gal total from form 4537436 MISLE Act.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2020
Resolved 1 March 2021

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.