Records from 1992 to 2025. Most recent: inspection, 10 October 2025.
Documentation record
Registered dimensions (L × B × D)60.0 ft × 22.1 ft × 7.5 ft
Registered tonnagegross 82 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderECONOMY BARGE REPAIR INC · PROCTORVILLE, OH, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portCINCINNATI, OH
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 May 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it82 - Simplified, Gross Ton
66 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
10 October 2025
COI Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 8250422
13 August 2025
Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 8207202
27 May 2021
Examination of Repairs
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7208523
20 October 2020
Initial Certification · Administrative Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7081299
7 March 2016
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5830541
17 November 2015
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5766135
21 February 2013
Industry Initiated Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4537436
15 March 2012
DAPI Audit
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4389216
6 December 2010
DAPI Audit
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3904896
6 December 2010
DAPI Audit
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3904904
14 January 2009
Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3394192
14 January 2009
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3394820
14 January 2009
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3395327
19 August 2008
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3304127
3 April 2008
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3180541
31 July 1997
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 756369
15 July 1997
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 198396
23 June 1997
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 106909
28 May 1996
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 140765
18 April 1994
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 179418
10 February 1994
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 111412
23 June 1992
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 121004
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 August 2025
Resolved
All fuel filters need to be put back to original manufacturers specifications (metal impingement bowls missing).
Action required: 705 - Other - as specified
Resolved 15 January 2026
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 August 2025
Resolved
Engine room bilge alarms need to be tested & crew familiar with testing
Action required: 705 - Other - as specified
Resolved 15 January 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 August 2025
Resolved
All emergency-stop pull cables need to be properly installed & tested
Action required: 705 - Other - as specified
Resolved 15 January 2026
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 August 2025
Resolved
Engine room emergency lighting needs to be repaired & tested
Action required: 705 - Other - as specified
Resolved 9 October 2025
Resolution: Engine room lighting sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 August 2025
Resolved
Deck washdown pump needs to be repaired (electrical)
Action required: 705 - Other - as specified
Resolved 9 October 2025
Resolution: Deck washdown pump sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 August 2025
Resolved
Verify cable size and application for both main engines starting batteries
Action required: 705 - Other - as specified
Resolved 9 October 2025
Resolution: Cable size and application for both M/E starting batteries verified.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 13 August 2025
Resolved
#1 main engine needs harmonic balancer guard installed
Action required: 705 - Other - as specified
Resolved 15 January 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 August 2025
Resolved
Separate type 1 and type 3 lifejackets
Action required: 705 - Other - as specified
Resolved 9 September 2025
Resolution: Lifejackets properly stowed
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 August 2025
Resolved
Crew needs to understand how to properly configure & operate AIS
Action required: 705 - Other - as specified
Resolved 9 September 2025
Resolution: Crew operation/configuration of AIS sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 October 2020
Resolved
Both main engines and generators did not have proper installed lagging on dry exhaust
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2020
Resolved 22 October 2020
Resolution: lagging was installed
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 October 2020
Resolved
Portable fire pump was not on board, hose nozzle and foot valve on board.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2020
Resolved 22 October 2020
Resolution: Conducted satisfaction operational test of portable fire pump with associated hoses and nozzle.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 20 October 2020
Resolved
No documentation of fire drill since 2018, crew admitted they have not done a fire drill in years.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2020
Resolved 22 October 2020
Resolution: Conducted fire drill with crew, improperly documented.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 October 2020
Resolved
Install flame shields on all fuel filters and engine room in accordance with manufactures design approval. Rakor plastic fuel bowl without flame shield.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2020
Resolved 18 December 2020
Resolution: Installed
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 20 October 2020
Resolved
Vessel could not provide the chart indicating inches of measurement of fuel to total in tank, total of six tanks onboard vessel 8500 gal total from form 4537436 MISLE Act.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2020
Resolved 1 March 2021