Records from 2001 to 2026. Most recent: inspection, 12 May 2026.
Documentation record
Registered dimensions (L × B × D)57.0 ft × 19.0 ft × 7.5 ft
Registered tonnagegross 54 / net 43
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMIDSHIP MARINE INC · NEW ORLEANS LA, UNITED STATES · built 2001
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portARABI, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 July 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Simplified, Net Ton
54 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
12 May 2026
Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8371494
27 June 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8133163
6 April 2025
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8126687
6 December 2024
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8069434
27 June 2024
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7915958
27 June 2023
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7712927
16 June 2022
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7473754
22 June 2021
Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7195251
4 August 2020
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7024210
1 August 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6761612
27 August 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6524698
7 September 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6260793
8 July 2016
Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5924678
1 October 2015
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5731274
31 August 2011
Drydock Exam · DAPI Audit · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4124791
19 September 2008
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3322491
15 October 2007
Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3076266
24 August 2005
Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2473075
22 September 2004
Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2201972
20 August 2003
Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1881680
15 August 2002
Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1660210
4 September 2001
Construction Oversight · Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1449500
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 June 2022
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. Upon examination MI observed four flexible hoses in the aft steering compartment degraded by corrosion. Exposed portions of the wire reinforced jacketing were exposed and corroding in addition to visible signs of other internal corrosion on the remaining hoses. Owner/operator to replace all four flexible hoses in the steering compartment with satisfactory in kind replacements.
46CFR182.720(e)
16c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 17 June 2022
Resolution: Operator provided documentation of replaced hoses and satisfactory installation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 June 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to: Provide services necessary for safety under normal and emergency conditions; Upon initial observation a portable battery charger was utilized to provide power to battery bank. Owner rep stated vessel had been laid up for a couple weeks and the batteries had lost charge and the installed in-port battery charger failed. Operator to replace battery charger and report condition of battery bank once time has passed allowing sufficient time to charge.
46CFR182.200(a)
16c.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 17 June 2022
Resolution: Operator provided documentation of replaced battery charger and condition of battery banks.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 16 June 2022
Resolved
An existing vessel must comply with the subdivision, damage stability, and watertight integrity regulations which were applicable to the vessel on March 10, 1996, or, as an alternative, the vessel may comply with the regulations in this part. Upon examination of the starboard void MI observed the natural vent check-ball as unserviceable. Upon further examination the remaining check-balls in all natural ventilation goosenecks were found in need of replacement due to weathering or inability to act as designed from paint application. Owner/operator to replace check-balls with appropriate replacements.
46CFR179.115
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 17 June 2022
Resolution: Operator replaced check-balls and provided corrected photos.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 June 2022
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. MI observed the starboard side light lens damaged allowing for a portion of the required green lens to be observed as white. Owner/operator to replace lens meeting this requirement.
46CFR183.420
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 17 June 2022
Resolution: Operator provided documentation of replaced stbd nav light lens.