Records from 1996 to 2025. Most recent: inspection, 2 October 2025.
Inspection history · 23
2 October 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8244849
24 September 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8007924
25 September 2023
Initial Certification · COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7798255
8 June 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7712853
28 February 2013
Administration · Deficiency Check
Physical examination · USCG East District (dp) · USCG East District (CGD-E) · Activity 4540815
9 September 2011
Industry Initiated Exam · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4140333
25 July 2011
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4094037
15 July 2011
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4089453
4 January 2009
Type not recorded
No type recorded · Station Chincoteague · USCG East District (CGD-E) · Activity 3388288
4 January 2009
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3388705
5 August 2008
Type not recorded
No type recorded · Station Chincoteague · USCG East District (CGD-E) · Activity 3290293
5 August 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3291547
18 December 2007
Annual Inspection
Physical examination · Station Philadelphia · USCG East District (CGD-E) · Activity 3119808
11 November 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2544052
25 July 2003
Uninspected Towing Vessel
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1856604
14 July 2003
Uninspected Towing Vessel
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1856165
5 February 2002
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1484201
25 July 1999
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 126088
5 February 1999
Uninspected Towing Vessel
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1126614
15 May 1997
Uninspected Towing Vessel
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1096347
24 January 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 660917
23 January 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 399818
27 February 1996
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 388613
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 October 2025
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. One lifebuoy was found damaged and not fit for its intended use.
46 CFR 141.230
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2025
Resolved 8 October 2025
Resolution: Received new lifebouy
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2025
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. There was no means provided to secure ventilation to the machinery space.
46 CFR 144.605
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 October 2025
Resolved 8 October 2025
Resolution: Recived new canvas cover
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 October 2025
Resolved
Survival craft and stowage locations must be marked in accordance with the requirements of §§ 199.176 and 199.178 of this chapter. Stowage positions for lifejackets stowed in a berthing space or stateroom and all lifejacket containers must be marked in block capital letters and numbers with the minimum quantity, identity, and, if sizes other than adult or universal sizes are used on the vessel, the size of the lifejackets stowed inside the container. Lifejacket storage on wheelhouse not properly marked.
46 CFR 141.345
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 October 2025
Resolved 8 October 2025
Resolution: Label added to bench for location of life jacket/immersion suit
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 2 October 2025
Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. 46 CFR 160.040. Vessel only had one line throwing appliance in accordance to 46 CFR 160.040, which requires four. Vessel is limited to less than three miles offshore until rectified.
46 CFR 141.385
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 8 October 2025
Resolution: Provided pictures of all four projectiles.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 October 2025
Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 of § 141.370 for specified areas where the vessel operates. The table requires 6 day and 6 night for operations greater than three miles offshore, vessel only had 3 day and 3 night.
46 CFR 141.375(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 8 October 2025
Resolution: Provided pictures of all 12 flares
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2024
Resolved
Electrical components that pose an electrical hazard
must be in an enclosure. Electrical junction box and
receptacle underneath operation station were missing
covers. Replace covers to the satisfaction of attending
marine inspector.
46 CFR 143.400 (g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2024
Resolved 7 October 2024
Resolution: Received objective evidence via photographs of electrical convers installed, sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2024
Resolved
Individual circuit breakers on switchboards and
distribution panels must be labeled with a description
of the loads they serve. Inspector noticed breakers on
distribution panels were not labeled. Label breakers to
the satisfaction of the attending marine inspector.
46 CFR 143.400 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2024
Resolved 7 October 2024
Resolution: Received objective evidence via photographs of breakers labeled, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 September 2024
Resolved
For towing vessels with berthing aboard, a sufficient
number of additional lifejackets must be carried so that
a lifejacket is immediately available for persons at
each normally manned watch station. Pilot house and
upper wheel house were missing a lifejacket.
46 CFR 141.340 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2024
Resolved 7 October 2024
Resolution: Received objective evidence via photographs of lifejackets at each operation station, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 24 September 2024
Resolved
Each watch station, work station, and industrial work
site must have enough immersion suits to equal the
number of persons normally on watch in, or assigned to,
the station or site at one time. Pilot house and upper
wheel house were missing a immersion suit.
46 CFR 141.350 (a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2024
Resolved 7 October 2024
Resolution: Received objective evidence via photographs of immersion suit at each operation station, sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 September 2024
Resolved
Essential systems or equipment must be regularly tested
and examined. Vsl was unable to provide proof of testing
engine alarms.
46 CFR 143.245 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2024
Resolved 7 October 2024
Resolution: Received objective evidence via photographs of engine alarm testing log, sat.
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 24 September 2024
Resolved
A towing vessel with overnight accommodations and
alternating watches (shift work), when pulling, pushing
or hauling alongside one or more barges, must have a
system to detect when its master or mate (pilot) becomes
incapacitated. Vsl does not have a pilothouse alerter
system installed. Install Coast Guard approved
pilothouse alerter system, prior to credit drydock.
46 CFR 143.450 (a)
Action required: 705 - Other - as specified
Resolved 16 July 2026
Resolution: Prior to issuance of next 5 year COI
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 25 September 2023
Resolved
"Alarms must be visible and audible at each operating
station. The alarm located at the operating station may
be a summary alarm; if the alarm at the operating
station is a summary alarm, the specific alarm condition
must be indicated at the machinery or bilge location" no
audio or visual alarm in upper or lower wheelhouse.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 18 October 2023
Resolution: Alarms installed in upper wheelhouse
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 25 September 2023
Resolved
"Each device (Marine Sanitation Device) must have a
placard suitable for posting on which is printed the
operating instructions, safety precautions, and warnings
pertinent to the device. The size of the letters printed
on the placard must be one-eighth of an inch or larger."
Placard need on MSD
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 18 October 2023
Resolution: Placard posted up above Sewage holding tank
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 25 September 2023
Resolved
"On vessels with more than one operating station, only
one of them must be outfitted with a fire detection
control panel. Any other operating station must be
outfitted with either a fire detection control panel or
a remote indicator panel" Panel in upper wheelhouse not
mounted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 18 October 2023
Resolution: Panel screwed into wall of the upper wheelhouse
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 25 September 2023
Resolved
"In addition to the immersion suits required under
paragraph (a)(1) of this section, each watch station,
work station, and industrial work site must have enough
immersion suits to equal the number of persons normally
on watch in," additional 02 immersion suits required on
board
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 18 October 2023
Resolution: Operator purchased 8 new immersion suits
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 September 2023
Resolved
Emergency lighting must be provided for all internal
crew working and living areas. Emergency lighting
sources must provide for sufficient illumination under
emergency conditions to facilitate egress from each
space" E lighting required in Galley
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 18 October 2023
Resolution: New emergency light installed in the galley
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 September 2023
Resolved
"Each towing vessel must be equipped with an industrial
type first aid cabinet or kit, appropriate to the size
of the crew and operating conditions." First aid kit
missing all medication.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 18 October 2023
Resolution: emailed purchase receipt of new first aid kit
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 25 September 2023
Resolved
The following systems must be equipped with gauges at
the machinery location: (1) Main engine lubricating oil
pressure and main engine RPM; (3) Auxiliary generator
engine lubricating oil pressure and auxiliary generator
engine RPM" RPM guage missing on both MEs and port gen.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 18 October 2023
Resolution: new guages installed on both MEs and port gen
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2023
Resolved
"Electrical equipment and circuits must be clearly
marked and identified." Breakers are not labeled.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2023
Resolved 18 October 2023
Resolution: Electrical panel labeled
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 September 2023
Resolved
"Steering systems must meet ABS Rules for Building and
Classing Steel Vessels under 90 Meters" Port rudder post
packing glad loose and leaking at continuous drip.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 27 September 2023
Resolved 27 September 2023
Resolution: packing gland of rudder post tightend to stop leak
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 25 September 2023
Resolved
"The master must ensure that all hatches, doors, and
other openings designed to be watertight or weathertight
function properly." hatch door open in watertight
bulkhead btw laz and chain locker.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 September 2023
Resolved 27 September 2023
Resolution: hatch cover installed
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 25 September 2023
Resolved
"Vent pipes for integral fuel tanks. Each integral fuel
tank must have a vent that connects to the highest point
of the tank, discharges on a weather deck through a bend
of 180 degrees, and is fitted with a 30-by-30-mesh
corrosion-resistant flame screen."
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 18 October 2023
Resolution: mesh flame screen installed
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 25 September 2023
Resolved
"The emergency duties and duty stations required by this
section must be posted at each operating station and in
a conspicuous location in a space commonly visited by
crewmembers. If posting is impractical, such as in an
open boat, they may be kept onboard in a location
readily available to the crew."
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 18 October 2023
Resolution: operator created station bill with position-specific items. Posted in Galley.
Lifesaving › Lifejacket/PFD (Type IV) › Marking
Issued 25 July 2003
Resolved
Stencil vessel name to life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 July 2003
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 25 July 2003
Resolved
Mount CO2 extingusher in pilot house passageway. Extingusher does not have a bracket and is tied to ladder stanchion with cotton line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 25 July 2003
Resolution: Mounted in new bracket.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 25 July 2003
Resolved
Mount EPIRB to pilot house.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 25 July 2003
Engineering › Fuel Oil Service System › Hose
Issued 25 July 2003
Resolved
Fuel supply hose to starboard main diesel engine was chaffed to the wire core. Replace worn hose and install chaffing gear to new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 July 2003
Lifesaving › Visual Distress Signals (General) › Condition
Issued 25 July 2003
Resolved
Visual distress signal have expired 3 day 3 night. Renew kit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 July 2003
Engineering › Fuel Oil Service System
Issued 14 July 2003
Resolved
Replace fuel oil supply hose to Starboard Main Engine. Hose did not have chaffing gear and was chaffed through to metal inner jacket. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 24 July 2003
Resolution: Replaced hose, installed chaffing gear.
Lifesaving › Hand Flares › Condition
Issued 14 July 2003
Resolved
Distress signal kit flares expired, replace with new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 July 2003
Lifesaving › Buoyant Apparatus
Issued 14 July 2003
Resolved
Hydrostatic release was expired on EPIRB LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 July 2003
Resolution: Serviced and renewed
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 14 July 2003
Resolved
CO2 Extingusher in way of pilot house passageway was not mounted, placed on deck and held to stanchion with cotton line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 24 July 2003
Resolution: mounted in proper bracket.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 July 2003
Resolved
apply vessels name to ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 July 2003
Documentation
Issued 23 January 1997
Resolved
OIL TRANSFER PROCEDURES NOT ON BOARD VESSEL.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Documentation
Issued 23 January 1997
Resolved
OIL POLLUTION PLACARD NOT ONBOARD.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Lifesaving
Issued 23 January 1997
Resolved
STROBE LIGHT ON STARBOARD SIDE RING BOUY (AMIDSHIPS) NOT OPERATIONAL.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997