MAURY USCG vessel records
← All vessels

HENRY GIRLS

HENRY GIRLS is a 1983 towing vessel. The Coast Guard has recorded 23 inspections since 1996, most recently in October 2025, along with 36 deficiencies, 1 operational control and 2 casualty investigations between 2008 and 2009.

Records from 1996 to 2025. Most recent: inspection, 2 October 2025.

Built
1983
Last inspected
2 October 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 2 October 2025
…with no type recorded12
Operational controls None recorded without a removal date
Years with a record 14 calendar years (1996–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN9539
216129
Flag
UNITED STATES
Maury page id
psix-216129

Documentation record

Registered dimensions (L × B × D)67.1 ft × 26.0 ft × 10.2 ft
Registered tonnagegross 73 / net 49
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOASTAL PILOT INC · PROVIDENCE, RI, UNITED STATES · built 1983
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSTATEN ISLAND, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 December 2025 · expires 31 December 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it73 - Regulatory (Subpart C or D), Gross Ton
49 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

WITTE 1405 Freight Barge · MISLE 940092 · 25 July 2011 · activity 4094037WITTE 1405 Freight Barge · MISLE 940092 · 15 July 2011 · activity 4089453KOKOSING VI Freight Barge · MISLE 5050 · 4 January 2009 · activity 3388705JAMIE D Freight Barge · MISLE 6914 · 5 August 2008 · activity 3291547LEHIGH NO. 1 Freight Barge · MISLE 79825 · 25 July 1999 · activity 126088

Inspection history · 23

2 October 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8244849
24 September 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8007924
25 September 2023 Initial Certification · COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7798255
8 June 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7712853
28 February 2013 Administration · Deficiency Check
Physical examination · USCG East District (dp) · USCG East District (CGD-E) · Activity 4540815
9 September 2011 Industry Initiated Exam · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4140333
25 July 2011 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4094037
15 July 2011 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4089453
4 January 2009 Type not recorded
No type recorded · Station Chincoteague · USCG East District (CGD-E) · Activity 3388288
4 January 2009 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3388705
5 August 2008 Type not recorded
No type recorded · Station Chincoteague · USCG East District (CGD-E) · Activity 3290293
5 August 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3291547
18 December 2007 Annual Inspection
Physical examination · Station Philadelphia · USCG East District (CGD-E) · Activity 3119808
11 November 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2544052
25 July 2003 Uninspected Towing Vessel
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1856604
14 July 2003 Uninspected Towing Vessel
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1856165
5 February 2002 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1484201
25 July 1999 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 126088
5 February 1999 Uninspected Towing Vessel
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1126614
15 May 1997 Uninspected Towing Vessel
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1096347
24 January 1997 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 660917
23 January 1997 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 399818
27 February 1996 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 388613

Deficiency record · 36

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 October 2025 Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. One lifebuoy was found damaged and not fit for its intended use. 46 CFR 141.230
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2025
Resolved 8 October 2025
Resolution: Received new lifebouy
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2025 Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. There was no means provided to secure ventilation to the machinery space. 46 CFR 144.605
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 October 2025
Resolved 8 October 2025
Resolution: Recived new canvas cover
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 October 2025 Resolved
Survival craft and stowage locations must be marked in accordance with the requirements of §§ 199.176 and 199.178 of this chapter. Stowage positions for lifejackets stowed in a berthing space or stateroom and all lifejacket containers must be marked in block capital letters and numbers with the minimum quantity, identity, and, if sizes other than adult or universal sizes are used on the vessel, the size of the lifejackets stowed inside the container. Lifejacket storage on wheelhouse not properly marked. 46 CFR 141.345
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 October 2025
Resolved 8 October 2025
Resolution: Label added to bench for location of life jacket/immersion suit
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 2 October 2025 Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. 46 CFR 160.040. Vessel only had one line throwing appliance in accordance to 46 CFR 160.040, which requires four. Vessel is limited to less than three miles offshore until rectified. 46 CFR 141.385
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 8 October 2025
Resolution: Provided pictures of all four projectiles.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 October 2025 Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 of § 141.370 for specified areas where the vessel operates. The table requires 6 day and 6 night for operations greater than three miles offshore, vessel only had 3 day and 3 night. 46 CFR 141.375(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 8 October 2025
Resolution: Provided pictures of all 12 flares
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2024 Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Electrical junction box and receptacle underneath operation station were missing covers. Replace covers to the satisfaction of attending marine inspector. 46 CFR 143.400 (g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2024
Resolved 7 October 2024
Resolution: Received objective evidence via photographs of electrical convers installed, sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2024 Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Inspector noticed breakers on distribution panels were not labeled. Label breakers to the satisfaction of the attending marine inspector. 46 CFR 143.400 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2024
Resolved 7 October 2024
Resolution: Received objective evidence via photographs of breakers labeled, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 September 2024 Resolved
For towing vessels with berthing aboard, a sufficient number of additional lifejackets must be carried so that a lifejacket is immediately available for persons at each normally manned watch station. Pilot house and upper wheel house were missing a lifejacket. 46 CFR 141.340 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2024
Resolved 7 October 2024
Resolution: Received objective evidence via photographs of lifejackets at each operation station, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 24 September 2024 Resolved
Each watch station, work station, and industrial work site must have enough immersion suits to equal the number of persons normally on watch in, or assigned to, the station or site at one time. Pilot house and upper wheel house were missing a immersion suit. 46 CFR 141.350 (a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2024
Resolved 7 October 2024
Resolution: Received objective evidence via photographs of immersion suit at each operation station, sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 September 2024 Resolved
Essential systems or equipment must be regularly tested and examined. Vsl was unable to provide proof of testing engine alarms. 46 CFR 143.245 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2024
Resolved 7 October 2024
Resolution: Received objective evidence via photographs of engine alarm testing log, sat.
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 24 September 2024 Resolved
A towing vessel with overnight accommodations and alternating watches (shift work), when pulling, pushing or hauling alongside one or more barges, must have a system to detect when its master or mate (pilot) becomes incapacitated. Vsl does not have a pilothouse alerter system installed. Install Coast Guard approved pilothouse alerter system, prior to credit drydock. 46 CFR 143.450 (a)
Action required: 705 - Other - as specified
Resolved 16 July 2026
Resolution: Prior to issuance of next 5 year COI
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 25 September 2023 Resolved
"Alarms must be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm; if the alarm at the operating station is a summary alarm, the specific alarm condition must be indicated at the machinery or bilge location" no audio or visual alarm in upper or lower wheelhouse.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 18 October 2023
Resolution: Alarms installed in upper wheelhouse
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 25 September 2023 Resolved
"Each device (Marine Sanitation Device) must have a placard suitable for posting on which is printed the operating instructions, safety precautions, and warnings pertinent to the device. The size of the letters printed on the placard must be one-eighth of an inch or larger." Placard need on MSD
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 18 October 2023
Resolution: Placard posted up above Sewage holding tank
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 25 September 2023 Resolved
"On vessels with more than one operating station, only one of them must be outfitted with a fire detection control panel. Any other operating station must be outfitted with either a fire detection control panel or a remote indicator panel" Panel in upper wheelhouse not mounted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 18 October 2023
Resolution: Panel screwed into wall of the upper wheelhouse
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 25 September 2023 Resolved
"In addition to the immersion suits required under paragraph (a)(1) of this section, each watch station, work station, and industrial work site must have enough immersion suits to equal the number of persons normally on watch in," additional 02 immersion suits required on board
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 18 October 2023
Resolution: Operator purchased 8 new immersion suits
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 September 2023 Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space" E lighting required in Galley
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 18 October 2023
Resolution: New emergency light installed in the galley
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 September 2023 Resolved
"Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions." First aid kit missing all medication.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 18 October 2023
Resolution: emailed purchase receipt of new first aid kit
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 25 September 2023 Resolved
The following systems must be equipped with gauges at the machinery location: (1) Main engine lubricating oil pressure and main engine RPM; (3) Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM" RPM guage missing on both MEs and port gen.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 18 October 2023
Resolution: new guages installed on both MEs and port gen
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2023 Resolved
"Electrical equipment and circuits must be clearly marked and identified." Breakers are not labeled.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2023
Resolved 18 October 2023
Resolution: Electrical panel labeled
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 September 2023 Resolved
"Steering systems must meet ABS Rules for Building and Classing Steel Vessels under 90 Meters" Port rudder post packing glad loose and leaking at continuous drip.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 27 September 2023
Resolved 27 September 2023
Resolution: packing gland of rudder post tightend to stop leak
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 25 September 2023 Resolved
"The master must ensure that all hatches, doors, and other openings designed to be watertight or weathertight function properly." hatch door open in watertight bulkhead btw laz and chain locker.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 September 2023
Resolved 27 September 2023
Resolution: hatch cover installed
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 25 September 2023 Resolved
"Vent pipes for integral fuel tanks. Each integral fuel tank must have a vent that connects to the highest point of the tank, discharges on a weather deck through a bend of 180 degrees, and is fitted with a 30-by-30-mesh corrosion-resistant flame screen."
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 18 October 2023
Resolution: mesh flame screen installed
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 25 September 2023 Resolved
"The emergency duties and duty stations required by this section must be posted at each operating station and in a conspicuous location in a space commonly visited by crewmembers. If posting is impractical, such as in an open boat, they may be kept onboard in a location readily available to the crew."
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 18 October 2023
Resolution: operator created station bill with position-specific items. Posted in Galley.
Lifesaving › Lifejacket/PFD (Type IV) › Marking
Issued 25 July 2003 Resolved
Stencil vessel name to life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 July 2003
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 25 July 2003 Resolved
Mount CO2 extingusher in pilot house passageway. Extingusher does not have a bracket and is tied to ladder stanchion with cotton line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 25 July 2003
Resolution: Mounted in new bracket.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 25 July 2003 Resolved
Mount EPIRB to pilot house.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 25 July 2003
Engineering › Fuel Oil Service System › Hose
Issued 25 July 2003 Resolved
Fuel supply hose to starboard main diesel engine was chaffed to the wire core. Replace worn hose and install chaffing gear to new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 July 2003
Lifesaving › Visual Distress Signals (General) › Condition
Issued 25 July 2003 Resolved
Visual distress signal have expired 3 day 3 night. Renew kit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 July 2003
Engineering › Fuel Oil Service System
Issued 14 July 2003 Resolved
Replace fuel oil supply hose to Starboard Main Engine. Hose did not have chaffing gear and was chaffed through to metal inner jacket. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 24 July 2003
Resolution: Replaced hose, installed chaffing gear.
Lifesaving › Hand Flares › Condition
Issued 14 July 2003 Resolved
Distress signal kit flares expired, replace with new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 July 2003
Lifesaving › Buoyant Apparatus
Issued 14 July 2003 Resolved
Hydrostatic release was expired on EPIRB LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 July 2003
Resolution: Serviced and renewed
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 14 July 2003 Resolved
CO2 Extingusher in way of pilot house passageway was not mounted, placed on deck and held to stanchion with cotton line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 24 July 2003
Resolution: mounted in proper bracket.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 July 2003 Resolved
apply vessels name to ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 July 2003
Documentation
Issued 23 January 1997 Resolved
OIL TRANSFER PROCEDURES NOT ON BOARD VESSEL.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Documentation
Issued 23 January 1997 Resolved
OIL POLLUTION PLACARD NOT ONBOARD.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Lifesaving
Issued 23 January 1997 Resolved
STROBE LIGHT ON STARBOARD SIDE RING BOUY (AMIDSHIPS) NOT OPERATIONAL.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997

Casualty record · 2

5 August 2008Routine · role: Involved in a Marine Casualty · 1 dead · activity 3291547
4 January 2009Routine · role: Involved in a Marine Casualty · activity 3388705
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

HUNT GIRLS (2008–2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.