Records from 2001 to 2026. Most recent: inspection, 24 February 2026.
Inspection history · 34
24 February 2026
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8314935
13 November 2025
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8293815
6 October 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8245832
1 July 2025
Examination of Repairs · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8183759
6 November 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8029524
11 January 2024
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7850522
11 October 2023
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7806545
23 June 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7721514
10 January 2023
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7619125
3 November 2022
Deficiency Check · Annual Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7587713
28 March 2022
Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7420634
7 October 2021
Administrative Inspection · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7328622
28 June 2021
Internal Structural Exam · Hull Examination · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7237926
19 June 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4908552
21 May 2014
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4863500
9 July 2012
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4372922
7 April 2009
Re-Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3447827
29 May 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3222020
12 April 2007
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2906656
2 February 2007
Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 2866504
2 February 2007
Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 2912315
18 April 2006
Internal Structural Exam · MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2627658
30 March 2006
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2612644
20 April 2005
Annual Inspection · Hull Examination · MTSA/ISPS Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2337503
6 April 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2327577
10 August 2004
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2162370
7 May 2004
Examination of Repairs · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2064185
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971314
2 April 2003
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1762599
29 October 2002
Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1670753
1 October 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1682329
23 August 2002
Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1665422
25 June 2002
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1635981
2 April 2001
Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366551
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 October 2025
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. All navigations lights (All-around light, port and starboard side lights and stern light light-bulbs were found not to be in compliance with UL1104; and the red side light and stern light diffuser lens was found damaged by UV light. 46 CFR 183.420 16C.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2025
Resolved 20 November 2025
Resolution: New UL1104 approved bulbs and lens installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 October 2025
Resolved
connections and terminations to all conductors must retain the original electrical, mechanical, flame-retarding, and, where necessary, fire-resisting properties of the cable. All connecting devices must be suitable for copper stranded conductors. Dead-ending wires were found in the A/C compartment in the main passenger deck. 46 CFR 111.60-17 16C.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2025
Resolved 20 October 2025
Resolution: A Junction box was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2024
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Fuel shutoff valve was found not working, not closing the valve. 46 CFR 182.455(4). 17C
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2024
Resolution: Valve was repaired, re-tested and found fully operational.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 6 November 2024
Resolved
Each hatch exposed to the weather must be watertight. Engine room and steering room hatches were found leaking water inside the compartment. 46 CFR 174.220, 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2024
Resolved 12 December 2024
Resolution: Hatch was adjusted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 November 2024
Resolved
Marine employers may form or otherwise use sponsoring organizations, or may use contractors, to conduct the random chemical testing programs required by this part. Proof on enrollment was dated YR2023. Provide an updated drug and alcohol program proof of enrollment with an updated list of mariners for YR 2024-2025. 46 CFR 6.230(d) 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2024
Resolved 4 December 2024
Resolution: Proof of enrollements was provided for the vessel crew in a DAPI program.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 6 November 2024
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space. USCG Inspector found the following areas of concern that shall conduct repairs or actions:
1. A fracture located in the transverse frame, port quarter in the steering room. Conduct temporary repairs prior going to dry dock within 7 days. A permanent repair shall be conducted during next dry dock credit.
2. A fracture weld was found in the starboard side quarter, in the steering room. Conduct temporary repairs within 7 days. A permanent repair shall be conducted during next dry dock.
3. A fracture in a weld was found at the port ramp post. Conduct temporary repairs within 7 days. PERMANENT REPAIRS SHALL BE CONDUCTED DURING NEXT DRY DOCK CREDIT. 46 CRF 176.600, 705C.
Action required: 705 - Other - as specified
Resolved 22 July 2025
Resolution: Verified port quarter and starboard lazarette cracks were repaired prior to this drydock. Verified port king post crack was repaired prior to this drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 October 2023
Resolved
46 CFR 182.100 All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
The water cooled Shaft bearing for the #1 and #4 main diesel engine has galvanic corrosion wastage on the flanges. Replace during next dry dock to the satisfaction of the attending marine inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 22 July 2025
Resolution: #1 and #4 MDE flanges were fabricated and replaced as original.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 January 2023
Resolved
Exhaust repairs to the port ships service generator
shall be examined and tested by the attending USCG MI's.
Following all repairs the CG may require sea trials in
in order to verify adequate work. 46 CFR 182.430
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2023
Resolution: USCG MSD St. Thomas attended the vessel in Subbase Drydock and observed repairs. All was satisfactory.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 10 January 2023
Resolved
The owner or managing operator shall notify the cognizant OCMI as far in advance as possible whenever the vessel is to be hauled out or placed in a dry dock or slipway in compliance with 176.600 or to undergo repairs or alterations affecting the safety of the vessel, together with the nature of any repairs or alterations contemplated. The owner/operator shall address failure of internal reporting procedures to the USCG ensure future statutory notifications are made as required.
Action required: 10 - Deficiency Rectified
Due 11 January 2023
Resolved 13 January 2023
Resolution: Vessel master has been provided all local contact information and states that he will make all future notificiatons on his own to ensure the CG is properly notified of intentions.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 January 2023
Resolved
Attending MI's noted that water was leaking from inside the vessels hull out to the dry-dock from the keel on the bow rake surrounding the bow thruster compartment. The source of the water intrusion shall be investigated and repairs made to the bow thruster seal and hull as needed to the satisfaction to the attending MI's. 46 CFR 176.700
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2023
Resolved 13 January 2023
Resolution: USCG MSD St. Thomas attended the vessel in Subbase Drydock and observed repairs. All was satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 3 November 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Pin holes in the hull structure were identified 59 inches above the waterline on the starboard side engine exhaust ventilation fan box. Day light is visible from inside the engine room. Submit a repair proposal for a permanent repair.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2022
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 3 November 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Multiple cracked welds were identified near the emergency exit in the starboard side steering compartment.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 November 2022
Resolved
Where pressure-indicating gages are used, they shall be chosen to be compatible with the pressure to be indicated. In no case shall the upper range of the gage be less than 1.2 times nor more than 2 times the pressure at which the relieving device is set to function. The range on the port side pressure vessel gage was not capable of visually indicating the setting of the pressure relief device.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 14 November 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 November 2022
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing machinery failure and personnel injury. The jacket water discharge temperature gage for the #2 engine was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 14 November 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 November 2022
Resolved
Piping, conveying vapor, gas or liquid with a temperature exceeding 150 degrees Fahrenheit must be suitably insulated where necessary to prevent injuries. The exhaust lagging steel cabling for the port and starboard engine requires tightening.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 14 November 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 November 2022
Resolved
Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. The light bulb for the bilge pump in the engine room was not operational.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 14 November 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 November 2022
Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Three heat exchangers in the machinery space were missing the U-bolts and were being held in place by ratchet straps.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 21 November 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 November 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; and minimize accidental personnel contact with energized parts. The electrical wiring on top of the OWS was exposed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 14 November 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 March 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements wihtout exceeding its designed limitations. One of four service engines was reported out of operation by vessel. Repair engine and conduct sea trial to satisfaction of attending marine inspector
Condition: Invalid
Due 5 April 2022
Resolved 13 December 2022
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 21 May 2014
Resolved
Port Exhaust (fwd pipe) needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2014
Resolved 2 June 2014
Resolution: pipe was removed and replaced with new pipe.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 21 May 2014
Resolved
Port exhaust trunk has pinhole leak and needs to be re welded.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2014
Resolved 2 June 2014
Resolution: Cut out collar and removed. Welded new collar in place.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 9 July 2012
Resolved
Floating ligths need to be secured around the body of the lifefloats
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2012
Fire Fighting › Fire Pumps › Arrangement
Issued 9 July 2012
Resolved
Fire pump for the vessel's fire monitor was removed for service.
Due 9 August 2012
Resolved 30 July 2012
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 9 July 2012
Resolved
Vessel's oil transfer procedures did not contain all the information required by 33CRF 155.750
Due 9 August 2012
Resolved 20 July 2012
Fire Fighting › Fire Pumps › Pressure
Issued 7 April 2009
Resolved
Firepump does not operate to 60 psi. Also duing operation fire pump attained an excessive leak. Demonstrate proper operation of fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 April 2009
Electrical › Electric Generation Source (service) › Panelboard
Issued 7 April 2009
Resolved
Provide blanks in panelboards where needed in engine room.
Action required: 705 - Other - as specified
Due 14 May 2009
Resolved 14 April 2009
Fire Fighting › Fixed Fire Detection System
Issued 11 April 2003
Resolved
CONDUCT OPEATIONAL TEST OF SYSTEM.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2003
Resolution: RECEIVED TEST REPORT FROM D&k Electric, Inc. OF OPERATIONAL TEST.
Documentation › Certificates/Documents
Issued 11 April 2003
Resolved
PROVIDE NEW RADIO TELEPHONY CERTIFICATE W/ VESSELS NEW CALL SIGN
Due 24 April 2003
Resolved 17 April 2003
Resolution: OBSERVED NEW CERTIFICATE.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 2 April 2003
Resolved
MAKE REPAIRS TO UNIONS AT BOTH TIME DELAYS TO ELIMINATE LEAKING OF CO2 AND CONDUCT OPERATIONAL TEST.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2003
Resolution: OBSERVED OPERATIONAL TEST OF SYSTEM.
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 April 2003
Resolved
RELOCATE BILGE ALARM SPEAKER FROM UNDER PRIMARY OPERATING STATION CABINET TO A LOCATION THAT IS AUDIOABLE TO THE MASTER WHILE VESSEL IS UNDERWAY.
Due 18 April 2003
Resolved 17 April 2003
Resolution: OBSERVED TEST AND RELOCATION OF ALARM SPEAKER.
Communications › Radio Communications
Issued 2 April 2003
Resolved
INSTALL VALID HYDROSTATIC RELEASE TO EPIRB LEGACY COMPONENT DESC: EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2003
Resolution: OBSERVED NEW HYDRO.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 2 April 2003
Resolved
INSTALL AT PRIMARY OPERATING STATION
Due 17 April 2003
Resolved 17 April 2003
Resolution: OBSERVED INSTALLATION AND OPERATION
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 April 2003
Resolved
PRIOR TO OPERATION OF OWS, SUBMIT OWS INSTALLATION PLANS TO MSC FOR REVIEW AND APPROVAL AND ONE COPY TO MSO MORGAN CITY. FINAL ACCEPATANCE OF THE OWS INSTALLATION WILL BE DETERMINED BY AN OPERATIONAL TEST OF THE OWS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46CFR177.202 PLAN APPROVAL.
Action required: 705 - Other - as specified
Resolved 10 August 2004
Resolution: Operation of OWS demonstrated during 11 May 2004 Re-Inspection, approved plans provided to MORMS on 10 Aug 2004.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 June 2002
Resolved
Do not operate oily water separator until repairs are made and proper operation can be demonstrated. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper Installation
Due 5 September 2002
Resolved 10 August 2004
Resolution: Operation of OWS demonstrated during 11 May 2004 Re-Inspection, approved plans provided to MORMS on 10 Aug 2004.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 June 2002
Resolved
Do not operate oily water separator until repairs are made and proper operation can be demonstrated.
Condition: Placed in Improper Service
Due 25 July 2002
Resolved 10 August 2004
Resolution: Operation of OWS demonstrated during 11 May 2004 Re-Inspection, approved plans provided to MORMS on 10 Aug 2004.