MAURY USCG vessel records Sign in
← All vessels

HERCULES 209

HERCULES 209 is a 1981 mobile offshore drilling unit. The Coast Guard has recorded 18 inspections since 1995, most recently in June 2014, along with 23 deficiencies.

Records from 1995 to 2014. Most recent: inspection, 19 June 2014.

Built
1981
Last inspected
19 June 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8752893 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
425492
Flag
UNITED STATES
—
Maury page id
psix-425492

Inspections, by type

…with no type recorded5
Years with a record 5 calendar years (1995–2014)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it5335 - Convention (Subpart B), Gross Ton
1756 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MR. ROW Passenger (Inspected) · MISLE 21830 · 19 June 2014 · activity 4908552

Inspection history · 18

19 June 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4908552
8 July 2008 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3261902
2 May 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3197407
14 April 2008 COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3171630
22 March 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3195228
25 August 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073142
2 July 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393721
14 April 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1061593
14 April 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1061595
23 January 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1056940
6 January 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1056815
29 October 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 8912
26 September 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 143542
11 August 2000 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1401295
7 July 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1379142
6 July 2000 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 819857
6 October 1995 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 875330
6 June 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1385490

Deficiency record · 23

Electrical › Electrical Distribution System (emergency) › Wiring
Issued 14 April 2008 Resolved
Wiring in Lower Shaker Room hanging down due to re-painting in the area.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 April 2008
Resolution: Provided Pictures of Wiring in Lower Shaker Room properly attached to bulkhead.
Electrical › Electric Generation Source (emergency) › Generator
Issued 14 April 2008 Resolved
Emergency Generator would not start.
Action required: 705 - Other - as specified
Resolved 21 April 2008
Resolution: Received statement of OIM that battery charger and batteries were replaced and Emergency Generator operating properly.
Fire Fighting › Fire Pumps › Pressure
Issued 14 April 2008 Resolved
Pressure Gauge did not function.
Action required: 705 - Other - as specified
Resolved 21 April 2008
Resolution: Received pictures and statement from OIM showing replacement of pressure gauge on fire pump.
Fire Fighting › Structural - B Class Divisions › Corridors
Issued 14 April 2008 Resolved
Class B Bulkhead at base of stairs on the main deck to the control room had a 1/2 inch gap along the bulkhead.
Action required: 705 - Other - as specified
Resolved 21 April 2008
Resolution: Received Pictures and statement from OIM showing repairs to the bulkhead.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 14 April 2008 Resolved
Class A Boundary Doors did not close close and latch unassisted.
Action required: 705 - Other - as specified
Resolved 21 April 2008
Resolution: Recieved Pictures and statement from OIM stating seals and latch assemblies are repaired and in proper working order.
Documentation › Certificates/Documents › MODU Safety Certificate
Issued 14 April 2008 Resolved
ABS had not issued Modu Code and Safety Certificate.
Action required: 705 - Other - as specified
Resolved 18 April 2008
Resolution: Received copy Modu Code and Safety Certificate.
Operations/Management › Drills/Instruction › Fire
Issued 14 April 2008 Resolved
3rd Patry Personnel were unsure of emergency procedures during fire drill.
Action required: 705 - Other - as specified
Resolved 21 April 2008
Resolution: Received statement from OIM attesting to training and drills with 3rd Party Personnel
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 14 April 2008 Resolved
Fire Control Plan did not accurately reflect fire boundaries around the galley and the mess deck. Area show as a Class 'B' Boundary and should be a Class 'A' Boundary. ABS has made pen and ink corrections, permanent revision are underway and will be sent to CG when complete.
Action required: 705 - Other - as specified
Resolved 30 April 2013
Resolution: Reviewed fire control plan during reactivation inspection. Plan satisfactory; Hercules submitting plan to ABS for review.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 14 April 2008 Resolved
Fire Control Plan did not accurately reflect Liferafts on board. Plan shows Davit Launched Liferafts. Float free type liferafts are on board. Location of rafts is correct on the plan. ABS has made pen and ink changes to plan, permanent revision are underway and will be sent to CG when complete.
Action required: 705 - Other - as specified
Resolved 30 April 2013
Resolution: Inspected fire control plan during reactiviation inspection. Plan matches onboard equiptment; Hercules submitted plan to ABS for review.
Unknown
Issued 2 July 2001 Resolved
HAVE AIR RECEIVER THAT SERVICES DRILL FLOOR INSPECTED BY AN ASME INSPECTOR.PROVIDE COPY OF REPORT TO THE [name withheld].
Condition: Unknown
Due 2 July 2001
Resolved 2 July 2001
Lifesaving › Emergency Outfit › Boots
Issued 2 July 2001 Resolved
CONDUCT FIRE DRILL IN THE PRESENCE OF A U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 2 September 2001
Resolved 14 April 2008
Resolution: Observed Fire Drill
Lifesaving
Issued 2 July 2001 Resolved
CROP AND RENEW WASTED METAL AT BOTH LIFEBOAT EMBARKATION STATIONS AND AT HELO DECK.
Condition: Unknown
Due 2 July 2001
Resolved 2 July 2001
Lifesaving › Emergency Outfit › Boots
Issued 2 July 2001 Resolved
PROVIDE DOCUMENTATION / DATA PLATE FOR #3 CEMENT DRY BULK TANK. TANK NOT TOBE USED UNTIL DATA PLATE IS PROVIDED.
Condition: Unknown
Due 2 September 2001
Resolved 14 April 2008
Resolution: Information provided for #3 Cement Dry Bulk Tank
Construction/Loadline
Issued 7 July 2000 Resolved
Make adjustments as necessary and prove proper operation of all watertight doors.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Electrical
Issued 7 July 2000 Resolved
Provide emergency power source for interior communication system.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Construction/Loadline
Issued 7 July 2000 Resolved
Make permanent repairs to holed deck in Emergency Generator space.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Electrical
Issued 7 July 2000 Resolved
Install transitional emergency lighting in way of embarkation stations and stairwell to Radio Room.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Electrical
Issued 7 July 2000 Resolved
Label all interior Emergency Lighting.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Engineering
Issued 7 July 2000 Resolved
Install and prove proper operation of relief valves on Main Generator starting air pressure vessels and Emergency Generator starting air pressurevessel.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Engineering
Issued 7 July 2000 Resolved
Renew or certify pressure vessel for Emergency Generator starting air system.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Accommodation/Occupational Safety
Issued 6 June 1995 Resolved
REMOVE ROPE MATERIAL AROUND WATER MAKER PIPING IN SAME SPACE.
Condition: Unknown
Due 6 June 1995
Resolved 6 June 1995
Accommodation/Occupational Safety
Issued 6 June 1995 Resolved
REMOVE ROPE MATERIAL AROUND EMD EXHAUST PIPING IN WATER MAKER SPACE.
Condition: Unknown
Due 6 June 1995
Resolved 6 June 1995
Engineering
Issued 6 June 1995 Resolved
INSTALL FLAME SCREEN TO EMERGENCY GENERATOR DIESEL FUEL DAY TANK.
Condition: Unknown
Due 6 June 1995
Resolved 6 June 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.