Records from 2009 to 2026. Most recent: inspection, 13 May 2026.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 May 2026
Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke signals. A red hand flare distress signal may be substituted for any of the hand orange smoke distress signals. Vessel has 03 hand orange smoke distress signals expired. Provide 12 serviceable distress flares. 46 CFR 180.68
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2026
Resolution: 12 serviceable flares installed on vessel
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2026
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2026
Resolved 15 June 2026
Resolution: First Aid/CPR certs updated and new AED pads installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2025
Resolved
All machinery installed and maintained in such a manner as to afford adequate protection against fire, explosion machinery failure and personnel injury. Fuel return line hose and fittings corroded and wasted. Repair and replace hose fittings and all fuel lines to meet flexible nonmetallic hose fuel line requirements (SAE J-1942 or USCG Type A1/A2). 46 CFR 182.01-5 (Old T)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2025
Resolution: All wasted Fuel hose lines, fitting and valves renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 March 2025
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). A submersible electric bilge pump may be used provided that: The pump is listed by an independent laboratory as meeting the requirements in UL 1113. Vessels forward engine compartment and fwd Bow compartment bilge pumps operable but not meeting the requirements of UL 1113. Pumps require renewal for UL listing (Rule 2000). 46CFR182.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2025
Resolved 28 March 2025
Resolution: Electric bilge pumps installed meeting UL requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 March 2025
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Port Engine hose/fitting located on aft end witnessed to be dripping fluid into bilge. (Video provided to owner). Provide evidence for secure hose/fitting and engine compartment bilge requires cleaning. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2025
Resolved 28 March 2025
Resolution: Fluid leak secured. bilge cleaned.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 May 2024
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessels alcohol test strips are expired. Provide valid alcohol test strips.
46 CFR 4.06-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2024
Resolved 24 May 2024
Resolution: Alcohol test strips provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 May 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Signs of leakage observed around rudder post seal. Replace or prove via in-water steering test that seal is not leaking.
46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2024
Resolved 24 May 2024
Resolution: Packing tightened to eliminate leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2023
Resolved
The marine inspector may require any part of the propeller shafting to be drawn for examination of stern bearing whenever the bearing is in question. The gap between bearing and shaft is approx quarter of an inch. Could not tell if bearing is beyond half original depth or if wrong size bearing installed. Install new bearing to reduce gap.
46 CFR 176.670
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 17 July 2023
Resolution: New stern cutlass bearing installed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 May 2023
Resolved
Each life float must be fitted with a light. The light must be a floating waterlight approved under approval series 161.010. The floating waterlight must be attached by a 3/8inch lanyard resistant to deterioration from UV light and at least 18 feet in length. Life float lights was not operational. Provide operational life float light. Vessel restricted to 3 miles from shore.
46 CFR 180.175(d)
Action required: 705 - Other - as specified
Due 19 June 2023
Resolved 16 June 2023
Resolution: Life float light provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 May 2023
Resolved
Each life float must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. Life float on board vessel has worn Type II retroreflective material. Add/replace retroreflective type material on life float.
46 CFR 185.604(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 16 June 2023
Resolution: Retro tape provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 May 2023
Resolved
Each paddle required for life floats must be at least four feet in length, lashed to the life float to which it belongs and buoyant. Life float paddles are not lashed to the life floats. Provide paddles be properly lashed to life floats onboard vessel.
46 CFR 180.175
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 16 June 2023
Resolution: Life float paddles lashed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 May 2023
Resolved
Each survival craft must be stowed in a way that any protective covers will not interfere with launching and embarkation. Covers secured with numerous bungee cords around body of life float. Provide cover that does will not interfere with launching or embarkation.
46 CFR 180.130(a)(8)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 16 June 2023
Resolution: Bungees removed from life float cover.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 May 2023
Resolved
The owner of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel for the intended service by providing certificates and operating manuals issued by the FCC. FCC Safety Radio Certificate was expired. Provide valid FCC Safety Radio Certificate.
46 CFR 176.402(c)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 17 July 2023
Resolution: FCC Safety Radio Certificate provided.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 19 May 2023
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Vessel has areas of damaged fiberglass with bulkhead pulling away from interior hull forward port side. Make repairs to bulkhead and interior hull.
46 CFR 177.300 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 16 June 2023
Resolution: Repairs to bulkhead and hull completed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 May 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found under helm. Remove dead end wires.
46 CFR 183.200 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 16 June 2023
Resolution: Dead end wires removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2023
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Ventilation duct opening could not stay closed/secured due to broken latch. Provide new latch to ensure vent closure remains closed.
46 CFR 182.465(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 16 June 2023
Resolution: new latch for vent closure provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 May 2023
Resolved
Battery installations must be mounted too protect against shifting of the vessel and free from exposure to water splash or spray. Vessel's batteries do not have boxes or covers. Provide battery box and covers.
46 CFR 183.350
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 16 June 2023
Resolution: Battery box and lid provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 May 2023
Resolved
During inspection the owner shall conduct tests and make the vessel available for all applicable inspections including firefighting systems. Did not test pre-engineered fixed fire fighting system (Fire Boy shutdown) due to vessel being in trailer. Provide video of simulated Fire Boy discharge by opening electrical
circuit. Show engine shuts down and visual/audible alarm
works and override works.
46 CFR 176.402(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 16 June 2023
Resolution: Pre-engineered fixed fire fighting testing completed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 May 2022
Resolved
As appropriate for the intended voyage vessel must carry adequate and up to date charts, US Coast Pilot [name withheld], and Tide Tables. Nav publication either missing or not updated. Provide updated nav publications.
46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 27 May 2022
Resolution: Nav pubs provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2022
Resolved
All machinery and equipment must be installed and maintained in such a manner to afford protection from causing machinery flooding. Slow leak found from rudder tube/packing. Repack rudder at next drydock.
46 CFR 182.100
Action required: 705 - Other - as specified
Due 31 May 2023
Resolved 28 March 2025
Resolution: New rudder packing installed. No leaks observed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2022
Resolved
Vessel does not currently meet the requirements of Work Instruction 31. Mandated crew posted on COI may not enter the water or act as lifeguard until policy and procedure provided. Provide written procedures.
46 CFR 176.100(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 19 May 2022
Resolution: Work Instruction 31 procedures provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2022
Resolved
Space containing fire extinguisher must be marked that extinguisher is inside space with 2 inch letters. No marking for extinguisher inside space at helm. Provide marking.
46 CFR 185.612
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 27 May 2022
Resolution: Marking provided.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 13 May 2022
Resolved
When discharge of untreated sewage is prohibited within 3 miles vessel must have either overboard valve closed
and valve handle removed, or padlock the valve handle closed when not pumping, or use non-releasable wire-tie to hold the valve handle closed.
33 CFR 159.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 19 May 2022
Resolution: Sewage locked.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 May 2022
Resolved
Vessel taking more than 6 passengers must have valid FCC Safety Radio Certificate. Safety Radio certificate provided after Safety inspection by FCC technician. Safety radio certificate was not on vessel. Provide valid Safety Radio Certificate.
46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 11 June 2022
Resolution: FCC doc provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2022
Resolved
To meet Work Instruction 31 Oxygen must be onboard and ready for use at all time. Items missing from Oxygen container to allow for ready use. Provide hose, mask, and full O2 bottle for oxygen. Vessel crew may not enter water until O2 is filled equipment provided, and the system functions as designed.
46 CFR 176.100(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 19 May 2022
Resolution: O2 filled and proper connections provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 21 May 2021
Resolved
Master and deckhand did not have first aid cards present. Provide valid first aid card for master and deckhand.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2021
Resolved 1 June 2021
Resolution: CPR cards provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 May 2021
Resolved
Forward fire extinguisher not mounted. Mount forward fire extinguisher.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2021
Resolved 1 June 2021
Resolution: Bracket provided.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 21 May 2021
Resolved
Crack in internal forward compartment starboard side. Grind out crack and make appraise repairs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2021
Resolved 1 June 2021
Resolution: Crack repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 May 2021
Resolved
Marking missing for emergency fuel shut off. Provide deck marking for fuel shut off.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2021
Resolved 1 June 2021
Resolution: FUel shut off marking provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2021
Resolved
The number of life jackets not marked in their storage area. Provide marking indicating how many life jackets are stowed in stowage area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2021
Resolved 1 June 2021
Resolution: Life jacket marking provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 May 2021
Resolved
Pre-engineeered fire fighting bottle showing corrosion. Provide new pre-engineered firefighting bottle (Fire Boy bottle) of at least 400 CUFT coverage area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2021
Resolved 1 June 2021
Resolution: Pre-engineered system provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 March 2020
Resolved
Four adult PFDs were unsatisfactory. Renew in accordacne with
46 CFR 176.808. Vessel limited to 25 total persons.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 May 2020
Resolution: PFDs provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 March 2020
Resolved
Fireboy manual pull cable was seized. Repair/renew in accordance with 46 CFR 176.810.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2020
Resolution: Fireboy manual pull cable renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 March 2020
Resolved
Lifefloat weaklink was oversized. Provide correct link in accordance with 46 CFR 176.808.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2020
Resolved 10 April 2020
Resolution: Correct weak link provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 March 2020
Resolved
Bilge overboard hose for forward space and rudder compartment were unsatisfactory. Provide satisfactory hose in accordance with 46 CFR 176.804.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2020
Resolved 10 April 2020
Resolution: Satisfactory hose provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 March 2020
Resolved
Airbox on engine is corroded and in need of renewal. Renew in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2020
Resolved 10 April 2020
Resolution: Airbox/silencer renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 March 2020
Resolved
Wet exhaust in rudder compartment was leaking. Repair in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2020
Resolved 30 March 2020
Resolution: Wet exhaust in rudder compartment repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 March 2020
Resolved
Propulsion engine has exhaust leak in vicinity of turbo. Reapir in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2020
Resolved 27 May 2020
Resolution: Exhaust leak repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 May 2019
Resolved
Replace wood and bolts on bow pulpit/anchor roller.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 June 2019
Resolved 21 August 2019
Resolution: Assembly renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 15 May 2019
Resolved
Add backing plate on forward stanchions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2019
Resolution: 1 1/4 inch fender washers were added to stanchion bolts.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 May 2019
Resolved
Renew the swimming platform.
Action required: 705 - Other - as specified
Due 13 June 2019
Resolved 12 August 2020
Resolution: New swim step installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 May 2019
Resolved
Repair fractured FRP upper right step connection and add backing plate for bolt reinforcement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2019
Resolution: Backing plate added.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 15 May 2019
Resolved
Provide securing procedure for MSD overboard discharge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2019
Resolution: Lock was added to MSD overboard discharge outlet
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 May 2019
Resolved
Ensure forward hatch is weathertight. Repair holes on the internal framing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2019
Resolution: Forward hatch was repaired to become weathertight