MAURY USCG vessel records Sign in
← All vessels

CORAL QUEEN

CORAL QUEEN is a 1983 passenger vessel (inspected). The Coast Guard has recorded 87 inspections since 1985, most recently in May 2026, along with 212 deficiencies and 2 casualty investigations in 2009.

Records from 1985 to 2026. Most recent: inspection, 13 May 2026.

Built
1983
Last inspected
13 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH4976
218419
Flag
UNITED STATES
367623240
Maury page id
psix-218419

Inspections, by type

…with no type recorded8
Years with a record 39 calendar years (1985–2026)
The 87 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)36.2 ft × 12.8 ft × 5.7 ft
Registered tonnagegross 15 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA BOAT WORKS · CAPE CANAVERAL, FL, UNITED STATES · built 1983
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKAUNAKAKAI, HI
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 13 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Regulatory (Subpart C or D), Gross Ton
10 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ2394MMSI 367623240 · active · compulsorily equipped · granted 5 March 2025, expires 5 March 2035
WDH4976MMSI 367623240 · expired · compulsorily equipped · granted 24 May 2014, cancelled 27 July 2024
WCQ8001MMSI 367023850 · cancelled · compulsorily equipped · granted 11 March 2005, cancelled 23 January 2012
WCX6334MMSI not assigned · expired · compulsorily equipped · granted 24 July 1997, cancelled 29 September 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

AMA LUA Passenger (Inspected) · MISLE 270188 · 15 February 2020 · activity 6910879

Inspection history · 87

13 May 2026 Annual Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8372158
13 May 2025 Deficiency Check · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8133632
12 March 2025 COI Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8092268
9 May 2024 Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 7909055
19 May 2023 Drydock Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7691038
13 May 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7449700
17 January 2022 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7380976
21 May 2021 Annual Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7200725
12 August 2020 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7031371
17 March 2020 COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6928739
15 February 2020 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6910879
21 August 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6807965
22 May 2019 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6691940
15 May 2019 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6683477
13 August 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6510605
24 May 2017 Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6154601
25 March 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6117993
25 July 2016 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6024314
5 October 2014 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5050683
13 May 2014 Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4870240
12 July 2011 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4079520
3 March 2010 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3689311
3 December 2009 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3648556
21 February 2008 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3151008
12 June 2007 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2959622
14 May 2007 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2930830
14 February 2006 Deficiency Check · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2584690
9 January 2006 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2567667
24 October 2005 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2520717
29 January 2005 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2282881
29 June 2004 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2115161
5 January 2004 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1974650
13 November 2003 Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1946778
4 April 2003 Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1763182
10 July 2002 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1644793
28 June 2002 Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1643001
4 October 2001 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1387186
25 October 2000 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1401463
30 June 2000 Damage Survey · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1395467
10 June 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 230259
10 November 1999 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1361245
24 August 1999 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1446814
1 May 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 152907
21 January 1999 Plan Review "T" Boat
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1378560
8 December 1998 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1434805
31 October 1997 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1398782
25 September 1997 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1364384
13 September 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 955593
27 August 1996 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1388115
30 November 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 884422
23 October 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1183292
10 October 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 757664
9 October 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 201267
21 September 1995 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1358924
10 July 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 882849
12 June 1995 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1188764
12 June 1995 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1385469
23 March 1995 Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1416104
14 February 1995 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 842166
12 September 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 865295
10 August 1994 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1412683
16 November 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 829782
5 August 1993 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1391896
15 June 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1151537
14 April 1993 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1429742
1 February 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 832209
28 January 1993 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 826823
4 January 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1144501
24 August 1992 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1444678
18 August 1992 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1250552
17 September 1991 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1244573
15 August 1991 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 945527
5 July 1991 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1257000
13 February 1991 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 922051
3 April 1990 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 899935
10 January 1990 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 925369
26 September 1989 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1303052
26 August 1989 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1340117
4 August 1989 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 894347
13 September 1988 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1348220
26 August 1988 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1040015
21 July 1988 COI Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1340130
15 March 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1302396
5 November 1987 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1328292
21 October 1986 Credit Drydock
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1009257
16 July 1985 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 982997
16 July 1985 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1025152

Deficiency record · 212

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 May 2026 Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke signals. A red hand flare distress signal may be substituted for any of the hand orange smoke distress signals. Vessel has 03 hand orange smoke distress signals expired. Provide 12 serviceable distress flares. 46 CFR 180.68
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2026
Resolution: 12 serviceable flares installed on vessel
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2026 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2026
Resolved 15 June 2026
Resolution: First Aid/CPR certs updated and new AED pads installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2025 Resolved
All machinery installed and maintained in such a manner as to afford adequate protection against fire, explosion machinery failure and personnel injury. Fuel return line hose and fittings corroded and wasted. Repair and replace hose fittings and all fuel lines to meet flexible nonmetallic hose fuel line requirements (SAE J-1942 or USCG Type A1/A2). 46 CFR 182.01-5 (Old T)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2025
Resolution: All wasted Fuel hose lines, fitting and valves renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 March 2025 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). A submersible electric bilge pump may be used provided that: The pump is listed by an independent laboratory as meeting the requirements in UL 1113. Vessels forward engine compartment and fwd Bow compartment bilge pumps operable but not meeting the requirements of UL 1113. Pumps require renewal for UL listing (Rule 2000). 46CFR182.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2025
Resolved 28 March 2025
Resolution: Electric bilge pumps installed meeting UL requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 March 2025 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Port Engine hose/fitting located on aft end witnessed to be dripping fluid into bilge. (Video provided to owner). Provide evidence for secure hose/fitting and engine compartment bilge requires cleaning. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2025
Resolved 28 March 2025
Resolution: Fluid leak secured. bilge cleaned.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 May 2024 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessels alcohol test strips are expired. Provide valid alcohol test strips. 46 CFR 4.06-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2024
Resolved 24 May 2024
Resolution: Alcohol test strips provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 May 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Signs of leakage observed around rudder post seal. Replace or prove via in-water steering test that seal is not leaking. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2024
Resolved 24 May 2024
Resolution: Packing tightened to eliminate leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2023 Resolved
The marine inspector may require any part of the propeller shafting to be drawn for examination of stern bearing whenever the bearing is in question. The gap between bearing and shaft is approx quarter of an inch. Could not tell if bearing is beyond half original depth or if wrong size bearing installed. Install new bearing to reduce gap. 46 CFR 176.670
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 17 July 2023
Resolution: New stern cutlass bearing installed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 May 2023 Resolved
Each life float must be fitted with a light. The light must be a floating waterlight approved under approval series 161.010. The floating waterlight must be attached by a 3/8inch lanyard resistant to deterioration from UV light and at least 18 feet in length. Life float lights was not operational. Provide operational life float light. Vessel restricted to 3 miles from shore. 46 CFR 180.175(d)
Action required: 705 - Other - as specified
Due 19 June 2023
Resolved 16 June 2023
Resolution: Life float light provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 May 2023 Resolved
Each life float must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. Life float on board vessel has worn Type II retroreflective material. Add/replace retroreflective type material on life float. 46 CFR 185.604(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 16 June 2023
Resolution: Retro tape provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 May 2023 Resolved
Each paddle required for life floats must be at least four feet in length, lashed to the life float to which it belongs and buoyant. Life float paddles are not lashed to the life floats. Provide paddles be properly lashed to life floats onboard vessel. 46 CFR 180.175
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 16 June 2023
Resolution: Life float paddles lashed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 May 2023 Resolved
Each survival craft must be stowed in a way that any protective covers will not interfere with launching and embarkation. Covers secured with numerous bungee cords around body of life float. Provide cover that does will not interfere with launching or embarkation. 46 CFR 180.130(a)(8)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 16 June 2023
Resolution: Bungees removed from life float cover.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 May 2023 Resolved
The owner of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel for the intended service by providing certificates and operating manuals issued by the FCC. FCC Safety Radio Certificate was expired. Provide valid FCC Safety Radio Certificate. 46 CFR 176.402(c)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 17 July 2023
Resolution: FCC Safety Radio Certificate provided.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 19 May 2023 Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Vessel has areas of damaged fiberglass with bulkhead pulling away from interior hull forward port side. Make repairs to bulkhead and interior hull. 46 CFR 177.300 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 16 June 2023
Resolution: Repairs to bulkhead and hull completed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 May 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found under helm. Remove dead end wires. 46 CFR 183.200 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 16 June 2023
Resolution: Dead end wires removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2023 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Ventilation duct opening could not stay closed/secured due to broken latch. Provide new latch to ensure vent closure remains closed. 46 CFR 182.465(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 16 June 2023
Resolution: new latch for vent closure provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 May 2023 Resolved
Battery installations must be mounted too protect against shifting of the vessel and free from exposure to water splash or spray. Vessel's batteries do not have boxes or covers. Provide battery box and covers. 46 CFR 183.350
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 16 June 2023
Resolution: Battery box and lid provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 May 2023 Resolved
During inspection the owner shall conduct tests and make the vessel available for all applicable inspections including firefighting systems. Did not test pre-engineered fixed fire fighting system (Fire Boy shutdown) due to vessel being in trailer. Provide video of simulated Fire Boy discharge by opening electrical circuit. Show engine shuts down and visual/audible alarm works and override works. 46 CFR 176.402(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 16 June 2023
Resolution: Pre-engineered fixed fire fighting testing completed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 May 2022 Resolved
As appropriate for the intended voyage vessel must carry adequate and up to date charts, US Coast Pilot [name withheld], and Tide Tables. Nav publication either missing or not updated. Provide updated nav publications. 46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 27 May 2022
Resolution: Nav pubs provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2022 Resolved
All machinery and equipment must be installed and maintained in such a manner to afford protection from causing machinery flooding. Slow leak found from rudder tube/packing. Repack rudder at next drydock. 46 CFR 182.100
Action required: 705 - Other - as specified
Due 31 May 2023
Resolved 28 March 2025
Resolution: New rudder packing installed. No leaks observed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2022 Resolved
Vessel does not currently meet the requirements of Work Instruction 31. Mandated crew posted on COI may not enter the water or act as lifeguard until policy and procedure provided. Provide written procedures. 46 CFR 176.100(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 19 May 2022
Resolution: Work Instruction 31 procedures provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2022 Resolved
Space containing fire extinguisher must be marked that extinguisher is inside space with 2 inch letters. No marking for extinguisher inside space at helm. Provide marking. 46 CFR 185.612
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 27 May 2022
Resolution: Marking provided.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 13 May 2022 Resolved
When discharge of untreated sewage is prohibited within 3 miles vessel must have either overboard valve closed and valve handle removed, or padlock the valve handle closed when not pumping, or use non-releasable wire-tie to hold the valve handle closed. 33 CFR 159.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 19 May 2022
Resolution: Sewage locked.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 May 2022 Resolved
Vessel taking more than 6 passengers must have valid FCC Safety Radio Certificate. Safety Radio certificate provided after Safety inspection by FCC technician. Safety radio certificate was not on vessel. Provide valid Safety Radio Certificate. 46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 11 June 2022
Resolution: FCC doc provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2022 Resolved
To meet Work Instruction 31 Oxygen must be onboard and ready for use at all time. Items missing from Oxygen container to allow for ready use. Provide hose, mask, and full O2 bottle for oxygen. Vessel crew may not enter water until O2 is filled equipment provided, and the system functions as designed. 46 CFR 176.100(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 19 May 2022
Resolution: O2 filled and proper connections provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 21 May 2021 Resolved
Master and deckhand did not have first aid cards present. Provide valid first aid card for master and deckhand.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2021
Resolved 1 June 2021
Resolution: CPR cards provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 May 2021 Resolved
Forward fire extinguisher not mounted. Mount forward fire extinguisher.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2021
Resolved 1 June 2021
Resolution: Bracket provided.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 21 May 2021 Resolved
Crack in internal forward compartment starboard side. Grind out crack and make appraise repairs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2021
Resolved 1 June 2021
Resolution: Crack repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 May 2021 Resolved
Marking missing for emergency fuel shut off. Provide deck marking for fuel shut off.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2021
Resolved 1 June 2021
Resolution: FUel shut off marking provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2021 Resolved
The number of life jackets not marked in their storage area. Provide marking indicating how many life jackets are stowed in stowage area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2021
Resolved 1 June 2021
Resolution: Life jacket marking provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 May 2021 Resolved
Pre-engineeered fire fighting bottle showing corrosion. Provide new pre-engineered firefighting bottle (Fire Boy bottle) of at least 400 CUFT coverage area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2021
Resolved 1 June 2021
Resolution: Pre-engineered system provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 March 2020 Resolved
Four adult PFDs were unsatisfactory. Renew in accordacne with 46 CFR 176.808. Vessel limited to 25 total persons.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 May 2020
Resolution: PFDs provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 March 2020 Resolved
Fireboy manual pull cable was seized. Repair/renew in accordance with 46 CFR 176.810.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2020
Resolution: Fireboy manual pull cable renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 March 2020 Resolved
Lifefloat weaklink was oversized. Provide correct link in accordance with 46 CFR 176.808.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2020
Resolved 10 April 2020
Resolution: Correct weak link provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 March 2020 Resolved
Bilge overboard hose for forward space and rudder compartment were unsatisfactory. Provide satisfactory hose in accordance with 46 CFR 176.804.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2020
Resolved 10 April 2020
Resolution: Satisfactory hose provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 March 2020 Resolved
Airbox on engine is corroded and in need of renewal. Renew in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2020
Resolved 10 April 2020
Resolution: Airbox/silencer renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 March 2020 Resolved
Wet exhaust in rudder compartment was leaking. Repair in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2020
Resolved 30 March 2020
Resolution: Wet exhaust in rudder compartment repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 March 2020 Resolved
Propulsion engine has exhaust leak in vicinity of turbo. Reapir in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2020
Resolved 27 May 2020
Resolution: Exhaust leak repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 May 2019 Resolved
Replace wood and bolts on bow pulpit/anchor roller.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 June 2019
Resolved 21 August 2019
Resolution: Assembly renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 15 May 2019 Resolved
Add backing plate on forward stanchions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2019
Resolution: 1 1/4 inch fender washers were added to stanchion bolts.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 May 2019 Resolved
Renew the swimming platform.
Action required: 705 - Other - as specified
Due 13 June 2019
Resolved 12 August 2020
Resolution: New swim step installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 May 2019 Resolved
Repair fractured FRP upper right step connection and add backing plate for bolt reinforcement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2019
Resolution: Backing plate added.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 15 May 2019 Resolved
Provide securing procedure for MSD overboard discharge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2019
Resolution: Lock was added to MSD overboard discharge outlet
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 May 2019 Resolved
Ensure forward hatch is weathertight. Repair holes on the internal framing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2019
Resolution: Forward hatch was repaired to become weathertight
Lifesaving › Lifebuoys › Serviceable
Issued 13 May 2014 Resolved
Retoreflective tape on life ring needs to be replaced.
Due 13 June 2014
Resolved 30 May 2014
Resolution: Retro tape replaced on lifering.
Documentation › Markings/Placards › Lifejacket Placard
Issued 13 May 2014 Resolved
Life jacket donning placard needs to be replaced.
Due 13 June 2014
Resolved 30 May 2014
Resolution: Replaced lifejacket donning placard.
Documentation › Certificates/Documents › FCC SSL
Issued 13 May 2014 Resolved
Radio station license expired.
Due 13 June 2014
Resolved 30 May 2014
Resolution: Renewed license
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 May 2014 Resolved
Replace expired first aid contents.
Due 13 June 2014
Resolved 30 May 2014
Resolution: Vessel outfitted with CG approved first aid kit.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 13 May 2014 Resolved
Secure spare battery.
Due 13 May 2014
Resolved 13 May 2014
Resolution: Secured spare battery.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 13 May 2014 Resolved
Exhaust manifold needs to be replaced.
Due 1 January 2015
Resolved 5 October 2014
Resolution: Vessel replaced exhaust manifold with new one.
Navigation › Piloting/Steering › Magnetic Compass
Issued 13 July 2011 Resolved
Prove operation of compass light
Action required: 705 - Other - as specified
Due 13 July 2011
Resolved 15 July 2011
Communications › Radio Communications › VHF Radiotelephone
Issued 13 July 2011 Resolved
Provide FCC Radio Telephone Safety Cert
Action required: 705 - Other - as specified
Due 31 July 2011
Resolved 30 September 2011
Communications › Radio Communications › VHF Radiotelephone
Issued 13 July 2011 Resolved
Provide Emergency Instruction List.
Action required: 705 - Other - as specified
Due 22 July 2011
Resolved 22 July 2011
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 13 July 2011 Resolved
Provide COD.
Due 30 August 2011
Resolved 13 July 2011
Electrical › Electric Supply System (service) › Battery Installation
Issued 24 January 2008 Resolved
Provide suitable battery box cover.
Due 7 February 2008
Resolved 1 February 2008
Resolution: Corrected.
Electrical › Electric Generation Source (service) › Conductor
Issued 24 January 2008 Resolved
Remove all dead end wiring and remove obsolete wiring circuits not in use, support loose wires with metal hold downs every 18 inches.
Due 7 February 2008
Resolved 1 February 2008
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 24 January 2008 Resolved
Renew fwd compartment door latches.
Due 7 February 2008
Resolved 1 February 2008
Resolution: Corrected.
Navigation › Collision/Grounding Avoidance › Relative Motion Plotting Equipment
Issued 14 May 2007 Resolved
Provide missing publications, US Coast Pilot, CG light list, Tide Tables.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2007
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 14 May 2007 Resolved
Renew faded retro tape on adult lifejackets.
Due 14 June 2007
Resolved 1 June 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 May 2007 Resolved
Remove wing nuts from batteries and replace with approved hardware.
Due 14 June 2007
Resolved 1 June 2007
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 14 May 2007 Resolved
Reinstall missing J-box cover in steering compartment.
Due 14 June 2007
Resolved 1 June 2007
Electrical › Electric Supply System (service) › Cable
Issued 14 May 2007 Resolved
Reattach bonding wire in steering compartment.
Due 14 June 2007
Resolved 1 June 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 May 2007 Resolved
Replace light on lifering.
Due 14 June 2007
Resolved 1 June 2007
Engineering › Lubricating Oil Service System › Pump
Issued 14 May 2007 Resolved
Repair non operational gauges (rpm,/oil pressure gauge)
Due 14 June 2007
Resolved 1 June 2007
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 14 February 2006 Resolved
FCC Operators license not on board
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 February 2006
Resolved 15 March 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 14 February 2006 Resolved
FCC radioteleohone permit not on board
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 February 2006
Resolved 15 March 2006
Lifesaving › Lifefloat › Serviceable
Issued 14 February 2006 Resolved
Lifefloat needs to be serviced by an approved lifesavings faclility
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2006
Resolved 14 February 2006
Lifesaving › Lifefloat › Float-free Link
Issued 14 February 2006 Resolved
Provide proof of weak link
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 15 March 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 14 February 2006 Resolved
Marking of fire extinguishers
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 15 March 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 14 February 2006 Resolved
Service or replace BI fire extinguishers
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 February 2006
Resolved 15 March 2006
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 February 2006 Resolved
Fuel shutoff cable not working properly
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 15 March 2006
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 14 February 2006 Resolved
Sea strainer must be mounted properly
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 15 March 2006
Engineering › Gasoline Engine (propulsion) › Exhaust Piping (4 cycle)
Issued 14 February 2006 Resolved
Re lagging of exhaust pipe
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 15 March 2006
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 February 2006 Resolved
Cover or remove old fire handle on main deck
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 15 March 2006
Engineering › Steering Gear System › Rudder
Issued 14 February 2006 Resolved
Provide and have on board emergency tiller
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 February 2006
Resolved 15 March 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 29 June 2004 Resolved
Provide marine radio operator permit
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 3 August 2004
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 29 June 2004 Resolved
Provide current publications of U.S. coast pilot, tide tables and tidal current tables.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 3 August 2004
Communications › Audible Communications › Bell
Issued 29 June 2004 Resolved
Provide ships bell
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 3 August 2004
Communications › Audible Communications › Horn/Whistle
Issued 29 June 2004 Resolved
Repair/replace ships horn
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 3 August 2004
Lifesaving › Lifejacket/PFD (General)
Issued 13 November 2003 Resolved
PROVIDE 3 CG APPROVED CHILD LIFEJACKETS AND STOW SEPARATE FROM ADULT LIFEJACKETS LEGACY COMPONENT DESC: Storage
Action required: 705 - Other - as specified
Due 3 December 2003
Resolved 2 January 2004
Lifesaving › Lifejacket/PFD (General)
Issued 13 November 2003 Resolved
STENCIL VESSELS NAME ON ALL LIFEJACKETS. LEGACY COMPONENT DESC: Marking
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 December 2003
Resolved 2 January 2004
Operations/Management › Drug and Alcohol Testing
Issued 13 November 2003 Resolved
PROVIDE EVIDENCE OF ENROLLMENT FOR ALL CREW IN ANNUAL DRUG & ALCOHOL PROGRAM. LEGACY COMPONENT DESC: MRO Drug Free Certificates
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 December 2003
Resolved 2 January 2004
Lifesaving
Issued 13 November 2003 Resolved
PROVIDE UPDATED EPIRB REGISTRATION.
Action required: 705 - Other - as specified
Due 3 December 2003
Resolved 2 January 2004
Communications › Radio Communications
Issued 13 November 2003 Resolved
POST LEGIBLE EMERGENCY BRODCAST PLACARD. LEGACY COMPONENT DESC: VHF Radiotelephone
Action required: 705 - Other - as specified
Due 3 December 2003
Resolved 2 January 2004
Lifesaving › Lifebuoys
Issued 13 November 2003 Resolved
RENEW STROBE LIGHT BATTERY
Action required: 705 - Other - as specified
Due 3 December 2003
Resolved 2 January 2004
Fire Fighting
Issued 13 November 2003 Resolved
PROVIDE 3 FIREBUCKETS OF 2.5 GALLONS WITH LINE ATTACHED AND STENCILED
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 December 2003
Resolved 1 January 2004
Electrical › Lighting (emergency)
Issued 13 November 2003 Resolved
PROVIDE 2 EMERGENCY PORTABLE LIGHTS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 December 2003
Resolved 2 January 2004
Engineering › Bilge Water Management System › Interface Detector
Issued 4 April 2003 Resolved
Reinstall fwd bilge pump and float switch.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2003
Resolution: Bilge bump and float switch installed and tested.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 4 April 2003 Resolved
Renew retro reflective tape on 25 of the 33 lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2003
Resolution: New retro tape installed on lifejackets.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 4 April 2003 Resolved
Provide 60' of line for ring buoy as required by 46 CFR 180.70 (c).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2003
Resolution: Line supplied for ring buoy.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 4 April 2003 Resolved
Mount 2 B-II fire extinguishers onboard in approved mounts.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2003
Resolution: Brackets provided and extinguishers mounted.
Lifesaving › Hand Flares › Quantity
Issued 4 April 2003 Resolved
Provide onboard 3 additional hand orange smoke distress signals and 3 additional hand red flare distress signals for a total of 6 each as required by 46 CFR 180.68.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2003
Resolution: Additional flares and smoke signals provided.
Lifesaving › Rigid Liferafts › Painter
Issued 4 April 2003 Resolved
Provide new sea painter for life float as required by 46 CFR 180.175 (f)(3).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2003
Resolution: New sea painter provided.
Communications › Radio Communications › EPIRB
Issued 4 April 2003 Resolved
Provide new battery for EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2003
Resolution: New battery installed in EPIRB.
Communications › Radio Communications › EPIRB
Issued 4 April 2003 Resolved
Proved new hydrostatic release for EPIRB.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2003
Resolution: New hydrostatic release installed.
Fire Fighting › Remote Fuel Shutoff
Issued 4 April 2003 Resolved
Stencil MDE emergency fuel shut valve location on deck. LEGACY COMPONENT DESC: Markings
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 20 May 2003
Resolution: Shut off valve cover stencilled.
Communications › Radio Communications › VHF Radiotelephone
Issued 4 April 2003 Resolved
Provide emergency broadcast placard at helm station helm station as required by 46 CFR 184.506.
Condition: Unknown
Due 18 April 2003
Resolved 18 April 2003
Resolution: Emergy broadcast placard provided and mounted.
Lifesaving › Rigid Liferafts
Issued 4 April 2003 Resolved
Make repairs to tears in lifefloat. LEGACY COMPONENT DESC: Buoyant Material
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 20 May 2003
Resolution: Tears repaired.
Fire Fighting › Ventilation Systems
Issued 4 April 2003 Resolved
Install new closure devices on both engine room ducts and provided means to positively close ducts in the event of fire in E/R space. LEGACY COMPONENT DESC: Duct Hatches
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 20 May 2003
Resolution: Aluminum closure devices installed to replace wooded ones.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 4 April 2003 Resolved
Provide on board current editions of the CG light list, Coast Pilot, Tide tables and Current tables as required by 46 CFR 184.420. As an acceptable alternative a Reed's Almanac may be substituted for the above publications.
Condition: Unknown
Due 18 April 2003
Resolved 8 April 2003
Resolution: Copies of applicable sections of pubs provided along with charts of area transitted.
Documentation › Certificates/Documents
Issued 4 April 2003 Resolved
Provide current FCC Safety Certificate onboard. LEGACY COMPONENT DESC: FCC SSL
Condition: Unknown
Due 18 April 2003
Resolved 20 May 2003
Resolution: FCC Safety Certificate onboard.
Documentation › Certificates/Documents
Issued 4 April 2003 Resolved
Provide onboard current/valid FCC Station License. LEGACY COMPONENT DESC: FCC SSL
Condition: Unknown
Due 18 April 2003
Resolved 20 May 2003
Resolution: FCC Station License onboard.
Documentation › Certificates/Documents
Issued 4 April 2003 Resolved
Provide onboard current Certificate of Documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Unknown
Due 18 April 2003
Resolved 20 May 2003
Resolution: Doc onboard.
Engineering › Bilge Water Management System
Issued 10 July 2002 Resolved
Install bilge pump circuit board and prove proper operation of all bilge pumps and bilge high water alarms. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2002
Resolution: Bilge pump circuit board installed and all pumps and high level alarms tested sat.
Operations/Management › Equipment Service/Testing
Issued 10 July 2002 Resolved
Install all sea valves and make vessel available for sea trials. LEGACY COMPONENT DESC: Sea valves
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2002
Resolution: All sea valves installed and instalation inspected. All sat.
Stability › Watertight Integrity
Issued 28 June 2002 Resolved
Plastic through hulls from bilge pump frozen and fractured when opened. LEGACY COMPONENT DESC: Bilge pump through hull valves and fittings
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2002
Resolved 28 June 2002
Resolution: Bronze through hull and valves installed.
Engineering › Bilge Water Management System › Pump
Issued 28 June 2002 Resolved
Bilge pump in steering (aft) compartment inop.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2002
Resolved 28 June 2002
Resolution: Problem with wiring corrected and proper operation of pump proven.
Engineering › Bilge Water Management System › Interface Detector
Issued 28 June 2002 Resolved
High level bilge alarms in the forward and aft (steering) compartments inop.
Condition: Unknown
Due 17 July 2002
Resolved 28 June 2002
Resolution: Bilge level to be checked at 30 minute intervals and alarms to be repaired at DD conducted on 10 July 02.
Documentation
Issued 4 October 2001 Resolved
Post the Certificate of Inspection, and the Stability Letter
Condition: Unknown
Due 4 November 2001
Resolved 21 December 2001
Lifesaving
Issued 4 October 2001 Resolved
Re-Tape the retroreflective tape for 03 child size lifejackets.
Condition: Unknown
Due 21 November 2001
Resolved 21 November 2001
Lifesaving
Issued 4 October 2001 Resolved
Provide new retroreflective tape to vessel's life float apparatus.
Condition: Unknown
Due 4 November 2001
Resolved 21 December 2001
Navigation
Issued 4 October 2001 Resolved
Provide the following navigational publications; US Coast pilot [name withheld] List, Tide Table, Tidal Current Table.
Condition: Unknown
Due 4 October 2001
Resolved 21 December 2001
Unknown
Issued 25 October 2000 Resolved
Mark vessel's name and hailing port, as required by 46 CFR 67.123 (46 CFR 185.602)_x001C_ s
Condition: Unknown
Due 3 November 2000
Resolved 4 May 2001
Construction/Loadline
Issued 30 June 2000 Resolved
Provide visual indicator for high bilge level alarms no later than 7JUL00._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 July 2000
Resolved 21 December 2001
Lifesaving
Issued 10 November 1999 Resolved
Provide an "Emergency Broadcast" placard and post at operating station, 46CFR184.506.
Condition: Unknown
Due 8 December 1999
Resolved 9 December 1999
Construction/Loadline
Issued 10 November 1999 Resolved
Double hose clamp bilge discharge line in aft compartment, 46CFR182.410(c)(1).
Condition: Unknown
Due 8 December 1999
Resolved 9 December 1999
Construction/Loadline
Issued 10 November 1999 Resolved
Provide support for the bilge pump discharge line, 46CFR182.530 (e)(5).
Condition: Unknown
Due 8 December 1999
Resolved 9 December 1999
Documentation
Issued 10 November 1999 Resolved
Provide original COI onboard for endorsement of re-inspection, and maintainonboard vessel, 46CFR176.107.
Condition: Unknown
Due 8 December 1999
Resolved 9 December 1999
Documentation
Issued 10 November 1999 Resolved
Provide original stability letter onboard vessel, 46 CFR 176.306.
Condition: Unknown
Due 8 December 1999
Resolved 9 December 1999
Navigation
Issued 10 November 1999 Resolved
Renew stern navigation light, wasted inside, 46CFR183.420.
Condition: Unknown
Due 8 December 1999
Resolved 9 December 1999
Fire Fighting
Issued 21 January 1999 Resolved
Install fully operational fixed fire fighting system for the engine room IAW 46CFR181.410.
Condition: Unknown
Due 9 June 1999
Resolved 15 June 1999
Construction/Loadline
Issued 21 January 1999 Resolved
Install fully operation high bilge level alarm system IAW 46CFR182.530._x001C_
Condition: Unknown
Due 9 June 1999
Resolved 15 June 1999
Lifesaving
Issued 8 December 1998 Resolved
VESSEL IS LIMITED TO 27 ADULT AND 2 CHILD PASSENGERS UNTIL PURCHASE 1 ADULTAND 1 CHILD LIFE PRESERVER. PROVIDE MSO SAN JUAN WITH FAX COPY OF BILL OF SALE.
Condition: Unknown
Due 18 January 1999
Resolved 29 January 1999
Documentation
Issued 8 December 1998 Resolved
PROVIDE PROPER DOCUMENTATION OF FULLY COMPLIANT CHEMICAL TESTING PROGRAM INACCORDANCE WITH 46CFR PART 16 FOR THE FOLLOWING DEFICIENCIES:_x001C_ -PRE EMPLOYMENT SCREENING_x001C_ -RANDOM TESTING
Condition: Unknown
Due 21 January 1999
Resolved 29 January 1999
Fire Fighting
Issued 8 December 1998 Resolved
VESSEL IS NOT TO GET UNDERWAY WITH PASSENGERS UNTIL, A NEW/SERVICABLE B-II FIRE EXTINGUISHER HAS BEEN PROVIDED. PROVIDE MSO SAN JUAN WITH FAX COPY OFBILL OF SALE OR SERVICE REPORT.
Condition: Unknown
Due 18 January 1999
Resolved 29 January 1999
Fire Fighting
Issued 8 December 1998 Resolved
PROVIDE BRACKET FOR B-II FIRE EXTINGUISHER FOR TOP SIDE PILOT CONT STATION.
Condition: Unknown
Due 18 January 1999
Resolved 29 January 1999
Documentation
Issued 8 December 1998 Resolved
PROVIDE VALID FCC RADIO OPERATOR'S LICENSE FOR MASTER. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Documentation
Issued 8 December 1998 Resolved
PROVIDE VALID ENDORCEMENT FOR VESSEL'S CERTIFICATE OF DOCUMANTATION.
Condition: Unknown
Due 18 January 1999
Resolved 29 January 1999
Accommodation/Occupational Safety
Issued 8 December 1998 Resolved
REPAIR CHAIN FOR AFT RAIL, RENEW CONNECTIONS TO PIPE.
Condition: Unknown
Due 18 January 1999
Resolved 29 January 1999
Engineering
Issued 8 December 1998 Resolved
PROVIDE OPERATING WATER TEMP GAGE ON TOPSIDE PILOT CONT. STATION.
Condition: Unknown
Due 18 January 1999
Resolved 29 January 1999
Engineering
Issued 8 December 1998 Resolved
PROVIDE OPERATING WATER TEMP, TACKOMETER, AND OIL PRESSURE GAUGE ON LOWER PILOT CONT STATION.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Documentation
Issued 8 December 1998 Resolved
STENCIL THE LADDER TO THE UPPER DECK PROHIBITING PASSENGERS FROM THE BRIDGEDECK, OR CONDUCT A STABILITY TEST.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Lifesaving
Issued 8 December 1998 Resolved
PROVIDE STORAGE FOR CHILD LIFE PRESERVERS SEPARATE FROM ADULTS.
Condition: Unknown
Due 18 January 1999
Resolved 29 January 1999
Documentation
Issued 31 October 1997 Resolved
PROVIDE PROOF OF APPLICATION FOR FCC RADIOTELEPHONY SAFETY CERTIFICATE
Condition: Unknown
Due 31 October 1997
Resolved 31 October 1997
Lifesaving
Issued 31 October 1997 Resolved
PROVIDE ONE (01) NEW LIFE JACKET
Condition: Unknown
Due 31 October 1997
Resolved 31 October 1997
Engineering
Issued 31 October 1997 Resolved
PROVIDE TIGHT CONNECTION FOR FUEL PICK-UP CONNECTION AT TOP OF FUEL TANK
Condition: Unknown
Due 31 October 1997
Resolved 31 October 1997
Engineering
Issued 31 October 1997 Resolved
PREMANENTLY STENCIL EMERGENCY FUEL SHUT OFF VALVE LOCATION ON DECK
Condition: Unknown
Due 31 October 1997
Resolved 31 October 1997
Electrical
Issued 31 October 1997 Resolved
PROVIDE PERMANENT REPAIRS TO STERNLIGHT WIRING
Condition: Unknown
Due 31 October 1997
Resolved 31 October 1997
Accommodation/Occupational Safety
Issued 31 October 1997 Resolved
PROVIDE APPROVAL DOCUMENTATION FOR NEWLY INSTALLED MARINE SANITATION DEVICE
Condition: Unknown
Due 31 October 1997
Resolved 31 October 1997
Lifesaving
Issued 31 October 1997 Resolved
PROVIDE CORROSION RESISTANT CLIP FOR WATERLIGHT HALYARD
Condition: Unknown
Due 31 October 1997
Resolved 31 October 1997
Lifesaving
Issued 31 October 1997 Resolved
PROVIDE NEW INSTRUCTION PLACARDS FOR DONNING LIFE JACKETS
Condition: Unknown
Due 31 October 1997
Resolved 31 October 1997
Lifesaving
Issued 31 October 1997 Resolved
RE-NEW RETRO-REFLECTIVE MATERIAL ON SIX (06) LIFE JACLETS
Condition: Unknown
Due 31 October 1997
Resolved 31 October 1997
Construction/Loadline
Issued 25 September 1997 Resolved
REPAIR MINOR BLISTERS PORT SIDE FOWARD.
Condition: Unknown
Due 10 October 1997
Resolved 20 October 1997
Construction/Loadline
Issued 25 September 1997 Resolved
PROVIDE FOR PROPER FIT OF PROPELLER TO SHAFT ON TAPER AT LEAST 80% CONTACT.
Condition: Unknown
Due 10 October 1997
Resolved 20 October 1997
Construction/Loadline
Issued 25 September 1997 Resolved
REPAIR FRACTURES TO STRUT PORT/STBD SIDES IN WAY OF KEEL ATTACHMENT POINT.
Condition: Unknown
Due 10 October 1997
Resolved 20 October 1997
Construction/Loadline
Issued 25 September 1997 Resolved
RENEW HYDRAULIC RESERVIOR FOR STEERING SYSTEM.
Condition: Unknown
Due 10 October 1997
Resolved 20 October 1997
Construction/Loadline
Issued 25 September 1997 Resolved
RE-PIPE SEWAGE OVERBOARD PIPING WITH MECHANICAL CONNECTIONS. (SWAGGED FITTINGS WIHT 2-CLAMPS)
Condition: Unknown
Due 10 October 1997
Resolved 20 October 1997
Construction/Loadline
Issued 25 September 1997 Resolved
RENEW SUPPORT BRACKET FOR STEERING RAM.
Condition: Unknown
Due 10 October 1997
Resolved 20 October 1997
Construction/Loadline
Issued 25 September 1997 Resolved
RENEW BALL JOINT CONNECTION AT STEERING RAM TO TILLER.
Condition: Unknown
Due 10 October 1997
Resolved 20 October 1997
Construction/Loadline
Issued 25 September 1997 Resolved
RELOCATE EPRIB BRACKET, TO PROVIDE A FLOAT FREE ARANGEMENT.
Condition: Unknown
Due 25 September 1997
Resolved 25 September 1997
Construction/Loadline
Issued 25 September 1997 Resolved
PROVIDE REPAIR PROPOSAL (WRITTEN) FOR FRACTURES AT SHEER LINE, INBOARD, PORT SIDE.
Condition: Unknown
Due 10 October 1997
Resolved 20 October 1997
Construction/Loadline
Issued 25 September 1997 Resolved
REPAIR FRACTURED SWIM PLATFORM ON PORT CORNER.
Condition: Unknown
Due 10 October 1997
Resolved 20 October 1997
Construction/Loadline
Issued 25 September 1997 Resolved
REPAIR DELAMINATIONS IN TRANSOM CUT OUT, PORT/STBD SIDES.
Condition: Unknown
Due 10 October 1997
Resolved 20 October 1997
Construction/Loadline
Issued 25 September 1997 Resolved
REPAIR KEEL DELAMINATION PORT SIDE, AMIDSHIPS.
Condition: Unknown
Due 10 October 1997
Resolved 3 November 1997
Engineering
Issued 27 August 1996 Resolved
LOWER THE PORT OR STBD ENGINE ROOM VENTILATION TO MEET THE REQUIREMENTS OF 46 CFR 182.460(a).
Condition: Unknown
Due 27 August 1996
Resolved 27 August 1996
Lifesaving
Issued 27 August 1996 Resolved
PRIOR TO 11 MARCH 1997 PROCURE AND INSTALL ONE FCC APPROVED TYPE ACCEPTED CATEGORY 1, 406MHZ EPIRB INSTALLED TO AUTOMATICALL FLOAT FREE AND ACTIVATE.
Condition: Unknown
Due 27 August 1996
Resolved 27 August 1996
Documentation
Issued 23 October 1995 Resolved
Provide valid Certificate of Documentation.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Electrical
Issued 23 October 1995 Resolved
Update vessels electrical drawing and submit to USCG for review.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Engineering
Issued 23 October 1995 Resolved
Restencil Emergency fuel shut off valve.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Lifesaving
Issued 23 October 1995 Resolved
Perform crew drills in presence of USCG Marine Inspector.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Engineering
Issued 23 October 1995 Resolved
Determine source & repair to eliminate oil from exhaust cooling water.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Accommodation/Occupational Safety
Issued 21 September 1995 Resolved
Overboard sewage discharge line requires a valve to close off.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Construction/Loadline
Issued 21 September 1995 Resolved
Repair one of the three electric bilge pumps.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Fire Fighting
Issued 21 September 1995 Resolved
Correctly mount B-I fire extinguisher in CG approved brackett.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Fire Fighting
Issued 21 September 1995 Resolved
Clear rust off of and lubricate mounting bracket for fire extinguisher in cabin.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Electrical
Issued 21 September 1995 Resolved
Clean out battery box and make acid tight.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Electrical
Issued 21 September 1995 Resolved
Secure wire runs in engine compartment with metal clips.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Engineering
Issued 21 September 1995 Resolved
Put plug in oil pan spigot.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Engineering
Issued 21 September 1995 Resolved
Seawater cooling hose needs a second clamp.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Engineering
Issued 21 September 1995 Resolved
Clean oil-soaked air intake on main engine.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Engineering
Issued 21 September 1995 Resolved
Supply line from fuel tank to filter should be a class II pipe._x001C_
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Construction/Loadline
Issued 21 September 1995 Resolved
Port and starboard porthole covers in cabin need to be repaired (port) or renewed (starboard).
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Electrical
Issued 21 September 1995 Resolved
Clean fuse terminals in head.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Electrical
Issued 21 September 1995 Resolved
Electrical wiring under dash needs to be neatly arranged. Unused wiring must be removed and new wiring should be tied up and neatly stowed.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Engineering
Issued 12 June 1995 Resolved
INSTALL FLAME IMPINGMENT BOWL ON RAYCOR FUEL FILTER.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Engineering
Issued 12 June 1995 Resolved
LABEL EMERGENCY FUEL CUT-OFF VALVE COVER.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Engineering
Issued 10 August 1994 Resolved
Renew or make permanant repairs to diesel fuel cooler.
Condition: Unknown
Due 10 September 1994
Resolved 27 September 1994
Lifesaving
Issued 10 August 1994 Resolved
Provide the Coast Guard with the company's written employee pre-employment and random drug testing program in accordance with Title 46 C.F.R. Part 16.
Condition: Unknown
Due 10 August 1994
Resolved 10 August 1994
Documentation
Issued 10 August 1994 Resolved
Obtain valid FCC operators license.
Condition: Unknown
Due 10 August 1994
Resolved 10 August 1994
Fire Fighting
Issued 10 August 1994 Resolved
Place on board two B-II and one B-I portable fire extinguishers and mount with approved mounting brackets.
Condition: Unknown
Due 10 August 1994
Resolved 10 August 1994
Engineering
Issued 5 August 1993 Resolved
Properly label fuel cut-off valve.
Condition: Unknown
Due 19 August 1993
Resolved 3 September 1993
Lifesaving
Issued 5 August 1993 Resolved
Renew stenciling of vessel name and number of persons on life float.
Condition: Unknown
Due 19 August 1993
Resolved 3 September 1993
Lifesaving
Issued 5 August 1993 Resolved
Properly attach waterlight to life float.
Condition: Unknown
Due 19 August 1993
Resolved 3 September 1993
Accommodation/Occupational Safety
Issued 14 April 1993 Resolved
RENEW SEA VALVE FOR MARINE SANITATION DEVICE FLUSHING WATER. PROVIDE COPY OF INVOICE TO OFFICE.
Condition: Unknown
Due 28 April 1993
Resolved 16 June 1993
Construction/Loadline
Issued 14 April 1993 Resolved
PROVIDE SATISFACTORY VENTILATION FOR FUEL TANK SPACE.
Condition: Unknown
Due 28 April 1993
Resolved 16 June 1993
Fire Fighting
Issued 14 April 1993 Resolved
PROVIDE ONE ADDITIONAL PORTABLE EXTINGUISHER, TYPE B-II. TOTAL NUMBER OF EXTINGUISHERS SHALL BE TWO B-II AND ONE B-I.
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Construction/Loadline
Issued 14 April 1993 Resolved
PLUG UNUSED MOUNTING SCREW HOLES IN AFT ENGINE COMPARTMENT BULKHEAD.
Condition: Unknown
Due 14 May 1993
Resolved 16 June 1993
Construction/Loadline
Issued 24 August 1992 Resolved
PROVE PROPER OPERATION OF BILGE PUMPS IN AFTER STEERING AND WATER TANK_x001C_ VOID.
Condition: Unknown
Due 25 August 1992
Resolved 23 November 1992
Lifesaving
Issued 24 August 1992 Resolved
REPLACE WEAKLINK ON LIFEFLOAT WITH A WEAKLINK OF PROPER CAPACITY AND I.D. TAG ATTACHED. 46 C.F.R.180.20-1
Condition: Unknown
Due 24 August 1992
Resolved 24 August 1992
Electrical
Issued 24 August 1992 Resolved
REMOVE ALL DEADEND WIRES IN WATER TANK VOID._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 August 1992
Resolved 24 August 1992
Construction/Loadline
Issued 24 August 1992 Resolved
RENEW DECK STIFFENER IN AFTER STEERING COMPARTMENT AS MARKED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 August 1992
Resolved 24 August 1992
Fire Fighting
Issued 24 August 1992 Resolved
ALL FIRE EXTINGUISHERS MUST HAVE THE BRACKETS THAT WERE PROVIDED WITH THEM.PERMANENTLY AFFIXED TO A SOLID STRUCTORUE AND THE EXTINGUISHERS PLACE IN THEM. ALL EXTINGUISHERS MUST ALSO BE SERVICED._x001C_
Condition: Unknown
Due 24 August 1992
Resolved 24 August 1992
Electrical
Issued 24 August 1992 Resolved
CLEAN CORROSION OFF STARTING BATTERIES TERMINALS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 August 1992
Resolved 23 November 1992
Electrical
Issued 24 August 1992 Resolved
OVERHEAD LIGHT BY LIFE PRESERVERS MUST BE UL APPROVED FOR"WET LOCATIONS" OR"MARINE".
Condition: Unknown
Due 24 August 1992
Resolved 24 August 1992
Unknown
Issued 15 August 1991 Resolved
CONDUCT IN PRESENCE OF CG INSPECTOR EMERGENCY DRILLS WHILE UNDERWAY WITH FULL CREW._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Engineering
Issued 13 February 1991 Resolved
INSTALL AN EMERGENCY FUEL CUTOUT/LABEL. NLT 15MAR91.
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Lifesaving
Issued 13 February 1991 Resolved
REPLACE TWO (2) ADULT PFD'S/VESSEL PASSENGERS ARE LIMITED TO 26 PASSENGER UNTIL THIS ITEM IS CORRECTED BUT NLT 15MAR91.
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Lifesaving
Issued 13 February 1991 Resolved
REPLACE LIFE RING, NLT 15MAR91
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Lifesaving
Issued 13 February 1991 Resolved
REPAIR OR REPLACE BOUYANT APPARATUS/REPLACE GRAB LINE ON BOUYANT APPARATUS.INSTALL WEAK LINK. NLT 15MAR91
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Engineering
Issued 13 February 1991 Resolved
INSTALL HEAT SHIELD ON RACOR FUEL OIL FILTER. ITEN TO BE COMPLETED NLT 15MAR91.
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Lifesaving
Issued 13 February 1991 Resolved
ENSURE ALL PFD'S HAVE VESSEL'S NAME, REGULE/REPLACE RETRO TAPE AS REQUIRED.ITEM TO BE COMPLETED NLT 15MAR91.
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Navigation
Issued 13 February 1991 Resolved
DE-RUST AND PAINT TILLER. ITEM TO BE COMPLETED BY 15MAR91.
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Documentation
Issued 4 August 1989 Resolved
OBTAIN FCC RADIO SAFETY CERTIFICATE AND PROVIDE MARINE SAFETY OFFICE COPY OF SAME.
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Documentation
Issued 21 July 1988 Resolved
PROVIDE COPY OF NEW FCC RADIO SAFETY CERTIFICATE TO [name withheld], PR
Condition: Unknown
Due 21 July 1988
Resolved 21 July 1988
Engineering
Issued 21 July 1988 Resolved
REPLACE MAIN ENGINE SEA SUCTION VALVE WITH NEW SUITABLE REPLACEMENT PRIOR TO PLACING VESSEL BACK INTO WATER.
Condition: Unknown
Due 21 July 1988
Resolved 21 July 1988
Engineering
Issued 21 July 1988 Resolved
REPLACE MAIN ENGINE THROTTLE CABLE WITH NEW SUITABLE REPLACEMENT.
Condition: Unknown
Due 21 July 1988
Resolved 21 July 1988
Lifesaving
Issued 21 July 1988 Resolved
PROCURE AND INSTALL PROPER WEAK LINK FOR BOUYANT APPARATUS.
Condition: Unknown
Due 21 July 1988
Resolved 21 July 1988
Engineering
Issued 21 July 1988 Resolved
INSTALL AND PROPERLY LABEL EMERGENCY FUEL CUT OUT VALVE FOR MAIN ENGINE FUEL SUPPLY.
Condition: Unknown
Due 21 July 1988
Resolved 21 July 1988
Fire Fighting
Issued 16 July 1985 Resolved
REPLACE ONE (1) B-I FIRE EXTINGUISHER WITH TYPE B-II COAST GUARD APPROVED.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Lifesaving
Issued 16 July 1985 Resolved
PROCURE ONE APPROVED WATER LIGHT AND 100FT SEAPAINTER FOR BOUYANT APPARATUS.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Lifesaving
Issued 16 July 1985 Resolved
PROCURE SIX (6) HAND HELD ORANGE SMOKE FLARES FOR DAYTIME USE.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Engineering
Issued 16 July 1985 Resolved
ADJUST PROPELLER SHAFT PACKING TO CONTROLL EXCESS LEAKAGE OF WATER.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985

Casualty record · 2

8 June 2009Routine · role: Involved in a Marine Casualty · activity 3504610
6 September 2009Routine · role: Involved in a Marine Investigation (non-casualty) · activity 3636068
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.