Records from 1984 to 1994. Most recent: inspection, 28 March 1994.
Inspection history · 36
28 March 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 79393
6 February 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 476385
1 September 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1137219
25 August 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 360439
25 August 1993
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1425353
23 April 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 489312
11 December 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 146120
4 October 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 931905
10 September 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 353017
10 September 1992
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1384976
9 June 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 494775
15 November 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 655892
15 September 1991
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 939678
13 September 1991
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 942728
10 May 1991
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 526489
2 January 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1242463
19 September 1990
Certificate of Compliance · MARPOL Annex I Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 932087
27 May 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 440228
2 October 1989
Certificate of Compliance · MARPOL Annex I Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1321523
16 July 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 446132
20 October 1988
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1199718
12 April 1988
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 480958
2 March 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 321676
30 October 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 319406
30 October 1987
MARPOL Annex I Examination · Certificate of Compliance
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1331416
28 May 1987
MARPOL Annex II Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1334189
20 May 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 518752
20 May 1987
MARPOL Annex II Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1025923
27 October 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 312329
27 October 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1020417
20 May 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 450954
12 November 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1300982
9 November 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 305263
31 July 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 521046
26 May 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 302190
1 November 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 298645
Electrical
Issued 25 August 1993
Resolved
Prior to departing port have the emergency generator come on automatic and run with a load, this is to be accomplished to the satisfaction of the classification society prior to witnessing by Coast Guard Inspector.
Condition: Unknown
Due 25 September 1993
Resolved 26 August 1993
Construction/Loadline
Issued 25 August 1993
Resolved
Make #2 starboard clean ballast tank ready to enter (certified by a Marine Chemist) at next U.S. port.
Condition: Unknown
Due 25 September 1993
Resolved 1 September 1993
Deck/Cargo
Issued 10 September 1992
Resolved
Replace missing nuts on deck tank covers as required.
Condition: Unknown
Due 10 October 1992
Resolved 4 October 1992
Deck/Cargo
Issued 10 September 1992
Resolved
Replace all cement plugs on deck scuppers with mechanical closure devices.
Condition: Unknown
Due 10 October 1992
Resolved 4 October 1992
Electrical
Issued 10 September 1992
Resolved
Install non-conductive matting in front of switchboard in engine control room.
Condition: Unknown
Due 10 October 1992
Resolved 4 October 1992
Construction/Loadline
Issued 10 September 1992
Resolved
Have one ballast tank certified "safe for entry" by a Marine Chemist and make tank available for inspection by a Coast Guard inspector.
Condition: Unknown
Due 10 October 1992
Resolved 4 October 1992
Electrical
Issued 10 September 1992
Resolved
Repair cableway conduit in way of #2c tank.
Condition: Unknown
Due 10 October 1992
Resolved 4 October 1992
Deck/Cargo
Issued 10 September 1992
Resolved
Replace missing drain cock valve on IGS line in way of deck water seal.
Condition: Unknown
Due 10 October 1992
Resolved 4 October 1992
Electrical
Issued 10 September 1992
Resolved
Renew straps for dresser couplings on deck as required on electrical conduit.
Condition: Unknown
Due 10 October 1992
Resolved 4 October 1992
Engineering
Issued 10 September 1992
Resolved
Renew valve handle for steam return in way of superstructure.
Condition: Unknown
Due 10 October 1992
Resolved 4 October 1992
Navigation
Issued 13 September 1991
Resolved
PRIOR TO VESSEL'S DEPARTURE, PROVE PROPER OPERATION OF SINGLE SIDE BAND RADIO TO [name withheld].
Condition: Unknown
Due 13 September 1991
Resolved 13 September 1991
Deck/Cargo
Issued 13 September 1991
Resolved
PRIOR TO RETURNING TO U.S. WATERS, MAKE PERMANENT REPAIRS TO VENTURI IN INERT GAS MAIN LINE IN WAY OF DECK SEAL.
Condition: Unknown
Due 13 September 1991
Resolved 13 September 1991
Construction/Loadline
Issued 30 October 1987
Resolved
REPLACE ALL FIBERGLASS,(FRP),BUTTERWORTH COVERS WITH STEEL OR EQUIVALENT MATERIAL OR PROVIDE PROOF OF SATISFACTORY "BURN TEST", AS REQUIRED.
Condition: Unknown
Due 30 October 1987
Resolved 30 October 1987