MAURY USCG vessel records Sign in
← All vessels

NEAMONI

NEAMONI is a 1971 freight ship. The Coast Guard has recorded 42 inspections since 1989, most recently in November 2003, along with 90 deficiencies and 4 operational controls.

Records from 1989 to 2003. Most recent: inspection, 25 November 2003.

Built
1971
Last inspected
25 November 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7110921 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
222411
Flag
PANAMA
—
Maury page id
psix-222411

Inspections, by type

…with no type recorded37
Years with a record 14 calendar years (1989–2003)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3154 - Dead Weight, Metric Ton
1649 - Regulatory (Subpart C or D), Gross Ton
922 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GOLDEN ANCHOR Towing Vessel · MISLE 200777 · 25 February 2000 · activity 148322ENNO B Freight Ship · MISLE 248439 · 25 February 2000 · activity 148322DEE WHITE Towing Vessel · MISLE 427881 · 25 February 2000 · activity 148322

Inspection history · 42

25 November 2003 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1953899
18 November 2003 MARPOL Annex V Examination · Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1950717
5 November 2003 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1942415
16 June 2003 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1818837
5 June 2003 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1810492
4 June 2003 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1809650
3 April 2003 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1768037
23 July 2002 Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1650953
4 May 2001 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 289672
16 March 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 288074
13 August 2000 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 281068
16 April 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 276923
6 March 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 275569
25 February 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 148322
28 August 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 432140
13 July 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 430617
13 May 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 428632
24 November 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 423200
6 June 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 41338
4 June 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 417603
4 June 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 418900
22 January 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 411612
12 August 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 763038
19 July 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 192074
8 May 1997 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 124996
18 April 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 402783
17 July 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 393485
18 June 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 392403
12 March 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 389723
27 September 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 383232
24 September 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 86969
9 May 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 378663
3 April 1995 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 671783
5 January 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 373974
2 August 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 863254
11 May 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 366994
4 June 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 351217
4 June 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 671784
12 February 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 341955
3 July 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 457907
4 February 1990 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 335204
12 October 1989 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 333011

Deficiency record · 90

Fire Fighting › Fire Pumps
Issued 18 November 2003 Resolved
Primary fire pump has an excessive water leak. Solas 60 CHI/ Reg 11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2003
Resolved 21 November 2003
Resolution: Class report States that fire pump tested under a pressure of 5 Bar, small leakage is alowed for lubricating/cooling of shaft seal.
Engineering › Sea-water System (primary cooling)
Issued 18 November 2003 Resolved
Salt water overboard pipe for main engine hold and leaking. Solas 60 CHI/ REG11 LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 18 December 2003
Resolved 21 November 2003
Resolution: Class Report from PRS States that Salt water overboard pipe from main engine has been repaired and is no longer leaking.
Engineering › Sea-water System (primary cooling)
Issued 18 November 2003 Resolved
#1 salt water cooler intake on end cap is holed and leaking. Solas CHI/ Reg11`````
Condition: Improper/Lack of Maintenance
Due 18 December 2003
Resolved 21 November 2003
Resolution: PRS Class Report states that Salt Water pipe connection to end cap No 1 F.W. jacket cooler on Main engine has been repaired with no leaks.
Communications
Issued 18 November 2003 Resolved
DSC Receiver for GMDSS is inoperable. Solas CHIV/ Reg4
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2003
Resolved 21 November 2003
Resolution: PRS Class Report states DSC Receiver for GMDSS Repaired and working satisfactory.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 18 November 2003 Resolved
Exhaust leak on starboard generator. Solas 60 CHI/ Reg11 This Item is to be repaired Prior to entry into port.
Action required: 705 - Other - as specified
Due 18 November 2003
Resolved 21 November 2003
Resolution: PRS States that exaust leak on starboard generator has been corrected and works properly.
Engineering › Sea-water System (primary cooling)
Issued 18 November 2003 Resolved
Saltwater piping for engine room air cooler holed and leaking. Solas 60 CHI/ Reg11 LEGACY COMPONENT DESC: Piping
Due 18 December 2003
Resolved 21 November 2003
Resolution: PRS Class REport States Salt Water pipe for A.C. cooling has been repaired and found statisfactory.
Engineering › Reduction Gearing/Clutches
Issued 18 November 2003 Resolved
Starboard main engine reduction gear has a major lube oil leak. Solas 60 CHI/ Reg11. Item is to be repaired prior to entry to port.
Action required: 705 - Other - as specified
Due 18 November 2003
Resolved 21 November 2003
Resolution: PRS Class report states all hydraulic oil lines reduction gearbox repaired and all leaks delt with.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 18 November 2003 Resolved
#1 and #6 heads on starboard main engine have fuel oil leaks in way of rocker arms. Solas 60 CHI/Reg 11. Item to be corrected prior to entry into port.
Action required: 705 - Other - as specified
Due 18 November 2003
Resolved 21 November 2003
Resolution: PRS Class Reports States Starboard main engine tested under running conditions. All dust cover cyl. heads removed for close up examination F.O. injector lines. reported leaks found remedied.
Fire Fighting
Issued 18 November 2003 Resolved
Vessel must amend fire control plan to reflect location of international shore connection. Solas 78 amend CHII-2/ Reg 20
Condition: Improper Installation
Due 18 December 2003
Resolved 21 November 2003
Resolution: Poliki Rijestr Statkon Class Report States that fire plan shows proper place of Intrnation shore Connection.
Lifesaving › Rescue Boat Equipment
Issued 18 November 2003 Resolved
Provide vessel with new batteries for GMDSS radios. Solas 74/78 CHIII/Reg6.2
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2003
Resolved 21 November 2003
Resolution: PRS Class report states that GMDSS Radios have been fitted with new Batteries.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 18 November 2003 Resolved
Vessel to install jacketed fuel lines on main engine. Solas 74a CHII-2/Reg 15.2.9 LEGACY COMPONENT DESC: Injector (fuel injection)
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2003
Resolved 21 November 2003
Resolution: PRS Class report states that double wall fuel oil lines on both main engines have been installed and level alarms have been tested Satisfactory.
Personnel › Manning/Qualifications
Issued 18 November 2003 Resolved
Company failed to ensure vessel was properly manned with a required chief mate who has second mate license and required 2nd engineer who does not have a valid license. An audit report is to be provided to this office prior to vessel getting released from detention. STCW95 CHIII/1 & CHII/1. LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 705 - Other - as specified
Due 18 November 2003
Resolved 21 November 2003
Resolution: Panama Flag faxed in letter and copy of a valid 2nd engineer [name withheld]
Operations/Management › Port and Waterways Safety
Issued 18 November 2003 Resolved
Vessel failed to report hazardous conditions to COTP including: generator exhaust leak, main engine fuel leaks, and main engine lube oil leak on reduction gear. LEGACY COMPONENT DESC: Notice of Hazardous Condition
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 November 2003
Resolution: Vsl reported all hazards after Audited by Class (PRS).
Documentation › Safety Management System
Issued 18 November 2003 Resolved
Vessel issued major non-conformity. Which states vessel has a systematic lack of proper follow up of corrective actions with regards correcting issued nonconformities that were due on 5 and 30 June 2003. Vessel is to remedy issues immediately to the satisfaction of class. LEGACY COMPONENT DESC: Conformity Maintenance Procedures
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 29 November 2003
Resolution: Item cleared.
Navigation › Piloting/Steering
Issued 4 June 2003 Resolved
LETTER OF DEVAITION FOR GYROCOMPASS WAS GRANTED FOR ENTRY INTO PORT OF SAVANNAH, GA. (33CFR 164.35 d) VSL IS REQUIRED TO MAKE REPAIRS AND PRODUCE A REPORT OF REPAIR TO MSO SAVANNAH PRIOR TO DEPATURE FROM THE PORT OF SAVANNAH. LEGACY COMPONENT DESC: Gyro Compass
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2003
Resolution: RECEIVED TECH REPORT CONFIRMING REPAIR TO GYRO. OPERATIONAL CONTROL LIFTED.
Engineering › Freshwater System (jacketwater cooling)
Issued 3 April 2003 Resolved
END CAPS FOR ENGINE ROOM F/W COOLERS ARE HOLED AND HAVE A TEMP. POLYMER RESIN PATCHES. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2003
Resolved 25 May 2003
Resolution: Received a class report # TAM/10/03,from Polski Rejestr Statkow classification society surveyor stating that,"newly rebuilt covers for main engine fresh water coolers were found fitted in place."
Engineering › Freshwater System (jacketwater cooling)
Issued 3 April 2003 Resolved
S/W INLET PIPE FOR #1 F/W COOLER HOLED AND LEAKING. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2003
Resolved 25 May 2003
Resolution: Received a class report # TAM/10/03,from Polski Rejestr Statkow classification society surveyor stating that," the S.W. circulation pipes for the main engine F.W. cooler have been repired."
Engineering › Lubricating Oil Service System
Issued 3 April 2003 Resolved
S/W INLET PIPE FOR #1 GENERATOR L/O COOLER HAS TEMP. PATCH. LEGACY COMPONENT DESC: Cooler
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2003
Resolved 25 May 2003
Resolution: Received class report #TAM/10/03 from Polski Rejestr Statkow classification society surveyor stating that " the S.W. circulation pipe for #1 generator LO cooler was partially cropped out and renewed."
Engineering › Fuel Oil Service System
Issued 3 April 2003 Resolved
REMOVE RUBBER FUEL OIL RETURN LINES FROM SSDG. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 4 April 2003
Resolution: ITEM CLEARED BY CLASS.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 3 April 2003 Resolved
EMERGENCY FIRE PUMP HAS LEAKING HEAD GASKET.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 4 April 2003
Resolution: ITEM CLEARED BY CLASS.
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 3 April 2003 Resolved
REPLACE FLAME SCREENS IN BOTH D.O.T. VENTS ON STBD SIDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 4 April 2003
Resolution: ITEM CLEARED BY CLASS.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 3 April 2003 Resolved
CRACK ON THE CRANKCASE OF #1 SSG PORTSIDE. CRACKS ARE LOCATED IN AN EXISTING POLYMER RESIN PATCH. FUEL OIL LEAK ON FUEL RETURN LINE. FUEL RETURN WAS REPAIRED. CRANKCASE TO BE REPAIRED AT A LATER DATE. LEGACY COMPONENT DESC: Crankcase
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 May 2003
Resolved 25 May 2003
Resolution: Received class report,#TAM/10/03, from Polski Rejestr Statkow surveyor stating that the "crack in lower entablature(p) #1 main generator metallocked.
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 3 April 2003 Resolved
LACK OF FAMILIARIZATION OF VESSEL BY [name withheld] BY VESSEL SMS. [name withheld] EXAM NEVER NOTING DAMAGE TO SSDG CRANKCASE.
Action required: 705 - Other - as specified
Due 3 April 2003
Resolved 4 April 2003
Resolution: CLASS CONDUCTED ISM EXTERNAL AUDIT.
Documentation › Safety Management System › Master's Authority/Responsibility Documentation
Issued 3 April 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 3 April 2003
Resolved 4 April 2003
Resolution: CLASS CONDUCTED ISM EXTERNAL SURVEY.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 3 April 2003 Resolved
VESSEL TO CONDUCT FULL ISM AUDIT TO THE SATISFACTION OF FLAG ADMINISTRATION.
Action required: 705 - Other - as specified
Due 3 April 2003
Resolved 4 April 2003
Resolution: CLASS CONDUCTED FULL EXTERNAL ISM SURVEY.
Engineering › Diesel Engine (auxiliary)
Issued 23 July 2002 Resolved
No.1 generator, No.6 cylinder has an excessive fuel oil leak. Vessel is not to use No.1 generator until No.6 cylinder injector is repaired. LEGACY COMPONENT DESC: Injector (fuel injection)
Action required: 705 - Other - as specified
Due 24 July 2002
Resolved 25 July 2002
Resolution: Local repair facility replaced copper washers and flag state representative verified proper repairs.
Engineering › Diesel Engine (auxiliary)
Issued 23 July 2002 Resolved
NO.2 generator, NO.3 cylinder injector has an excessive fuel oil leak. LEGACY COMPONENT DESC: Injector (fuel injection)
Action required: 705 - Other - as specified
Due 24 July 2002
Resolved 25 July 2002
Resolution: Received flag state report satisfying requirement.
Engineering › Diesel Engine (auxiliary)
Issued 23 July 2002 Resolved
NO.1 generator has a notable jacket water leak from one or more cylinder head o-rings.
Action required: 705 - Other - as specified
Due 29 July 2002
Resolved 25 July 2002
Resolution: Received flag report satisfying requirement.
Engineering
Issued 16 March 2001 Resolved
Both main engine injector box drain lines are rubber and piped directly to the bilge. Re pipe drain lines as original and route to proper drain tank prior to departure. SOLAS 74a I/11
Condition: Unknown
Due 16 March 2001
Resolved 20 March 2001
Lifesaving
Issued 16 March 2001 Resolved
Excessive oil in bilge. Remove all oil from bilge and provide invoice priorto departure. SOLAS 60 II/35
Condition: Unknown
Due 16 March 2001
Resolved 27 March 2001
Fire Fighting
Issued 16 March 2001 Resolved
Fire and general service pump frames severely wasted. Provide class report attesting to the structural integrity of frame by 23MAR01. SOLAS 74a I/11
Condition: Unknown
Due 23 March 2001
Resolved 27 March 2001
Deck/Cargo
Issued 16 March 2001 Resolved
13 pontoon cover lifting rings severly wasted. Replace all marked lifting rings to the satisfaction of class prior to cargo operations. _x001C_ SOLAS 74a I/11
Condition: Unknown
Due 16 March 2001
Resolved 20 March 2001
Engineering
Issued 16 March 2001 Resolved
Vessel could not demonstrate proper operation of oily water separator. Provide class report proving proper operation. MARPOL 73/78 annex I/16
Condition: Unknown
Due 16 March 2001
Resolved 20 March 2001
Engineering
Issued 16 March 2001 Resolved
Port main engine has temporary patch on cooling water line to #1 cylinder._x001C_permanently repair to the satisfaction of Class prior to departure._x001C_ SOLAS 74a I/11
Condition: Unknown
Due 16 March 2001
Resolved 27 March 2001
Electrical
Issued 16 March 2001 Resolved
Both generators missing turbo chargers. Provide class report attesting to this arrangement. _x001C_ Class issued COC to provide documentation from manufacturer on operation with or without turbo's by 21APR01
Condition: Unknown
Due 4 May 2001
Resolved 4 May 2001
Engineering
Issued 16 March 2001 Resolved
Port main engine jacket water pump seal leaking excessively. Repair to the satisfaction of Class prior to departure. SOLAS 74a I/11
Condition: Unknown
Due 16 March 2001
Resolved 27 March 2001
Electrical
Issued 16 March 2001 Resolved
Starboard generator fuel oil inlet pipe to fuel pump crimped and leaking. Repair to the satisfaction of Class prior to departure. SOLAS 74a I/11
Condition: Unknown
Due 16 March 2001
Resolved 27 March 2001
Engineering
Issued 16 March 2001 Resolved
Both main engine rear oil seals leaking excessively. Repair to the satisfaction of Class prior to departure. SOLAS 74a I/11
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Documentation
Issued 6 March 2000 Resolved
CLASSIFICATION DOCUMENT EXPIRED.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Documentation
Issued 6 March 2000 Resolved
INADEQUATE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Lifesaving
Issued 6 March 2000 Resolved
STBD BRIDGE WING LIFEBUOY WASTED.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Fire Fighting
Issued 6 March 2000 Resolved
INSUFFICIENT NUMBER OF FIRE HOSE.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Navigation
Issued 6 March 2000 Resolved
FATHOMETER OPERATES INTERMITTANTLY.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Unknown
Issued 6 March 2000 Resolved
SOFT PATCH ON CHAIN LOCKER SUCTION LINE IN PAINT LOCKER.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Accommodation/Occupational Safety
Issued 6 March 2000 Resolved
GALLEY EXHAUST FAN COATED WITH GREASE.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Lifesaving
Issued 6 March 2000 Resolved
"US DIVERS" BREATHING APPARATUS INOPERATIVE.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Documentation
Issued 6 March 2000 Resolved
ON-BOARD MAINTENANCE PROGRAM.
Condition: Unknown
Due 17 April 2000
Resolved 17 April 2000
Engineering
Issued 6 March 2000 Resolved
LEAKING STBD MAIN DIESEL ENGINE COOLING WATER PUMP SEAL.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Engineering
Issued 6 March 2000 Resolved
PORT MAIN DIESEL ENGINE COOLING WATER PIPE FITTING ON TURBINE SIDE.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Fire Fighting
Issued 6 March 2000 Resolved
MISSING PORTABLE 45 LITER FOAM FIRE FIGHTING APPLIANCE.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Navigation
Issued 6 March 2000 Resolved
MAGNETIC COMPASS NOT VISIBLE THROUGH BINNACLE AT HELM.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Fire Fighting
Issued 6 March 2000 Resolved
FIRE CONTROL PLANS UNREADABLE.
Condition: Unknown
Due 17 April 2000
Resolved 17 April 2000
Documentation
Issued 6 March 2000 Resolved
MISSING CREW MEDICAL CERTIFICATES.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Documentation
Issued 13 July 1999 Resolved
ANNOTATE IOPP CERTIFICATE TO REFLECT DIRTY OIL HOLDING TANK OF SEVEN (7)_x001C_ CUBIC METER CAPACITY BY CLASS SOCIETY._x001C_ MARPOL 73/78 ANNEX I REG. 4(e)
Condition: Unknown
Due 30 August 1999
Resolved 30 August 1999
Lifesaving
Issued 13 July 1999 Resolved
INSTALL QUICK RELEASE ARRANGEMENT FOR BOTH SMOKE/LIGHT BRIDGE WING BUOYS._x001C_ SOLAS 74 (AMENDED) III/19
Condition: Unknown
Due 30 August 1999
Resolved 30 August 1999
Navigation
Issued 13 May 1999 Resolved
Repair the echo sounder and recorder.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Fire Fighting
Issued 13 May 1999 Resolved
Provide satisfactory fire and abandon ship drills.
Condition: Unknown
Due 17 May 1999
Resolved 14 June 1999
Documentation
Issued 13 May 1999 Resolved
Provide a valid SOLAS safety radio certificate.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Documentation
Issued 13 May 1999 Resolved
Provide and place onboard an IOPP certificate supplement.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Fire Fighting
Issued 13 May 1999 Resolved
Renew the suction gauge on the #1 main fire pump.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Engineering
Issued 13 May 1999 Resolved
Provide class society documentation of satisfactory operation of the main engine and ship service generators raw water cooling systems.
Condition: Unknown
Due 17 May 1999
Resolved 7 June 1999
Fire Fighting
Issued 13 May 1999 Resolved
Provide two fireman's outfits, one SCBA, and two pair gloves to make two complete fireman's outfits.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Documentation
Issued 13 May 1999 Resolved
Provide a valid safe manning certificate and provide manning IAW it.
Condition: Unknown
Due 17 May 1999
Resolved 14 June 1999
Navigation
Issued 13 May 1999 Resolved
Provide class society documentation of satisfactory operation of the starboard steering motor.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Fire Fighting
Issued 13 May 1999 Resolved
Provide proper fire hose and dual purpose nozzles at all engine room fire stations.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Engineering
Issued 13 May 1999 Resolved
Remove the make-shift engine cooling water system from the starboard engineroom fire plug.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Engineering
Issued 4 June 1998 Resolved
Oily Water Separator alarm fails to function as required by MARPOL Annex I,Regulation 16.
Condition: Unknown
Due 4 June 1998
Resolved 4 July 1998
Documentation
Issued 12 March 1996 Resolved
MUST PROVIDE CERTIFICATE ISSUED BY A RECOGNIZED ORGANIZATION FOR AN "UNATTENDED MACHINARY SPACE" AS NOTED IN SAFE MANNING CERTIFICATE UNDER SPECIAL REQUIRMENTS/CONDITIONS.
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Lifesaving
Issued 27 September 1995 Resolved
PORTSIDE LIFEBOAT'S ROLLING CASTERS--6 OF 8 ARE NOT MOVING PROPERLY. (SOLASCHAP III PART C REG 44-6). CORRECT PRIOR TO DEPARTURE FROM NEW ORLEANS OR 30SEP95.
Condition: Unknown
Due 30 September 1995
Resolved 27 September 1995
Fire Fighting
Issued 27 September 1995 Resolved
FIRE HYDRANT FUST FORWARD OF SUPERSTRUCTURE IS INOPERABLE. (SOLAS CHAP II-2REG 4-1) CORRECT PRIOR TO DEPARTURE PORT OF NEW ORLEANS OR 30SEP95.
Condition: Unknown
Due 30 September 1995
Resolved 27 September 1995
Fire Fighting
Issued 27 September 1995 Resolved
VESSEL'S FIREMAIN HAS LEAK AT MAIN DECK CONNECTION AT SUPER STRUCTURE. (SOLAS CHAP II-2, REG 4 2.1) CORRECT PRIOR TO DEPARTURE FROM NEW ORLEANS ORBY 30SEP95.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Fire Fighting
Issued 27 September 1995 Resolved
EMERGENCY FIRE PUMPS PRESSURE GAUGE INOPERABLE. (SOLAS CHAP II-2, REG 4 2.1). CORRECT PRIOR TO NEXT U.S. PORT OR BY 27OCT95.
Condition: Unknown
Due 27 October 1995
Resolved 29 September 1995
Electrical
Issued 5 January 1995 Resolved
BARE WIRES FOUND IN FWD STORAGE (PAINT LOCKER)
Condition: Unknown
Due 5 January 1995
Resolved 9 January 1995
Electrical
Issued 5 January 1995 Resolved
FWD STORAGE (PAINT LOCKER) NEEDS EXPLOSION PROOF LIGHTING.
Condition: Unknown
Due 5 January 1995
Resolved 9 January 1995
Accommodation/Occupational Safety
Issued 5 January 1995 Resolved
FOUND TOILETS UNABLE TO BE FLUSHED.
Condition: Unknown
Due 5 January 1995
Resolved 9 January 1995
Electrical
Issued 11 May 1994 Resolved
Distribution pannel access door on main deck broken.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Electrical
Issued 11 May 1994 Resolved
Guard on rotating shaft hand crank to emergency fire pump was missing.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Lifesaving
Issued 11 May 1994 Resolved
Metalic support for oarlocks on both lifeboats were wasted.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Lifesaving
Issued 11 May 1994 Resolved
Aft seat on port lifeboat and forward seat on starboard lifeboat were wasted.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Lifesaving
Issued 11 May 1994 Resolved
Metal support pieces for davit hooks on both lifeboats were wasted.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Navigation
Issued 11 May 1994 Resolved
Vessel was missing a rudder angle indicator in the steering room.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Unknown
Issued 11 May 1994 Resolved
Vessel was not properly manned according to the safe manning certificate.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Navigation
Issued 11 May 1994 Resolved
Vessel had no means of communication between steering room and bridge.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Documentation
Issued 11 May 1994 Resolved
Vessel was missing supplement form E to the safety equipment certificate.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Construction/Loadline
Issued 11 May 1994 Resolved
Watertight door gasket wasted to battery room door. Hinge to bosun stores broken.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Fire Fighting
Issued 11 May 1994 Resolved
Hose and nozzle missing from fire station on aft area.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Fire Fighting
Issued 11 May 1994 Resolved
Vessel's fire plan was not readily accessible. Container holding plan was sealed shut.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Documentation
Issued 4 June 1992 Resolved
VESSEL FAILED TO INITIAL APROPRIATE SPACES ON DECLARATION OF INSPECTION.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Documentation
Issued 4 June 1992 Resolved
VESSELS OIL TRANSFER PROCEDURES WERE INCOMPLETE.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Documentation
Issued 12 October 1989 Resolved
33CFR151.25 IMPROPER ENTRIES IN THE OIL RECORD BOOK PART I. THE OIL RECORD BOOK PART I HAD "B" ENTRIES WHERE "C" ENTRIES BELONGED. AUTH: 33USC1903 PENALTY: 33USC1908
Condition: Unknown
Due 12 October 1989
Resolved 12 October 1989

Ownership record