MAURY USCG vessel records
← All vessels

DEE WHITE

Built
1995
Last inspected
21 January 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 21 January 2026
…with no type recorded15
Operational controls None recorded without a removal date
Years with a record 22 calendar years (1995–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9127227
WCW4132
427881
Flag
UNITED STATES
Maury page id
psix-427881

Documentation record

Registered dimensions (L × B × D)113.8 ft × 34.0 ft × 18.1 ft
Registered tonnagegross 161 / net 115
ITC dimensions (L × B × D)113.8 ft × 34.0 ft × 18.1 ft
ITC tonnagegross 480 / net 144
BuilderTRINITY MARINE GROUP · LOCKPORT, LA, UNITED STATES · built 1995
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 19 February 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it480 - Convention (Subpart B), Gross Ton
161 - Regulatory (Subpart C or D), Gross Ton
144 - Convention (Subpart B), Net Ton
115 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 33 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 11 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 11

Inspection history · 33

21 January 2026 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8291115
30 January 2025 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8072297
31 January 2024 TPO Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7865435
19 December 2023 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7840703
24 October 2023 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7813593
25 May 2023 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7707994
2 March 2023 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7644718
24 May 2022 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7443876
4 April 2021 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7269232
12 February 2021 Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7139939
14 April 2016 Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 5854566
7 February 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4795888
11 October 2013 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4739594
18 October 2012 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4462430
18 January 2011 MARPOL Annex VI Survey · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3928604
18 January 2011 MTSA Verification · DAPI Audit · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3928906
5 March 2009 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3424523
28 February 2008 Administration · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3150272
7 September 2006 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2771546
24 July 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2723326
24 July 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2723365
27 May 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2892997
18 November 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1951417
5 February 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1484136
16 January 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1660622
28 April 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 771841
26 April 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 206136
25 February 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 148322
3 February 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 715588
5 October 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 206135
9 April 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 168864
24 December 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 6288
3 November 1995 Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1360312

Deficiency record · 11

02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 16 March 2023 Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Forward hold watertight hatch gasket was loose. Repair/replace gasket to ensure watertight seal. 46CFR140.610(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2023
Resolved 27 March 2023
Resolution: The forward hold emergency hatch was serviced; all rust and debris was removed from the hatch cover and seal. A new gasket was installed; the hatch was closed and adjusted to ensure a proper water tight seal.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 March 2023 Resolved
The line throwing appliance must have: An auxiliary line that: (i) Is at least 450 meters (1,500 feet) long; (ii) Has a breaking strength of at least 40 kilonewtons (9,000 pounds-force); and (iii) Is, if synthetic, of a dark color or certified by the manufacturer to be resistant to deterioration from ultraviolet light. The line throwing appliance was missing an auxiliary line. Add auxiliary line. 46CFR141.385(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2023
Resolved 24 March 2023
Resolution: Auxillary line was aboard the vessel, crew was unable to located during inspection; same was located. Picture in docs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 March 2023 Resolved
Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced. Several fuel manifold valves were missing their locking mechanism. Repair/replace to original design. 46CFR143.245(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2023
Resolved 24 March 2023
Resolution: Fuel manifold valves missing springs in the position locator was repaired. Pictures in docs.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 16 March 2023 Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Dog on watertight door between the galley and engine room did not make contact when closed. Repair/replace to original design. 46CFR140.610(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2023
Resolved 24 March 2023
Resolution: Dog on water tight door between galley and engine room fiddley was adjusted; all others checked to ensure door closes and seals properly.
05 - Radio Communications › N/A - No Subsystem › Operation of GMDSS equipment
Issued 24 May 2022 Resolved
47 CFR 80.880 -Vessel GMDSS system is out of service. Vessel is limited to within 20NM offshore until required radio communication is operational for intended route.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2022
Resolved 5 July 2022
Resolution: Technician installed new SSB antenna and tested NavTex system with all test satisfactory.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 March 2021 Resolved
Missing blood pressure monitor
Action required: 705 - Other - as specified
Due 16 March 2021
Resolved 17 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 March 2021 Resolved
PFD had expired personel marker light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2021
Resolved 17 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 March 2021 Resolved
needs more flares prior to oceans route
Action required: 705 - Other - as specified
Due 16 March 2021
Resolved 17 March 2021
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 2 March 2021 Resolved
vessel needed lights installed in engine room and storage room
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2021
Resolved 17 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 March 2021 Resolved
flammable locker was not approved, vessel emptied all flammable goods out until new approved locker arrives
Action required: 705 - Other - as specified
Due 2 March 2021
Resolved 2 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 March 2021 Resolved
02 life rings needed retro replaced
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2021
Resolved 17 March 2021

Ownership record