MAURY USCG vessel records
← All vessels

ADVENT BAY

Built
1973
Last inspected
7 March 2019
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 7 March 2019
…with no type recorded10
Operational controls None recorded without a removal date
Years with a record 20 calendar years (1992–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7301271
HO7977
224140
Flag
PANAMA
Maury page id
psix-224140

Documentation record

Tonnage as PSIX records it1348 - Convention (Subpart B), Gross Ton
404 - Convention (Subpart B), Net Ton
2551 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 41 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ADVENTURER Towing Vessel · MISLE 145507 · 14 July 2009 · activity 3534027

Inspection history · 41

7 March 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6633332
7 March 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6365766
16 February 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6084538
2 February 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5807898
2 February 2015 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5060712
14 January 2015 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5068180
4 June 2014 Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4879509
6 March 2014 Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4810906
18 February 2014 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4800102
15 January 2014 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4783036
25 July 2013 Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4664098
15 July 2013 PII Safety Exam · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4651186
23 January 2013 PII Safety Exam · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4520270
1 August 2012 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4397102
28 June 2012 Deficiency Check · ISPS II Exam · PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4359302
9 November 2011 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4186246
19 October 2011 ISPS II Exam · PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4153651
15 December 2010 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3921022
15 November 2010 PII Safety Exam · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3888647
14 July 2009 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3534027
10 July 2009 MARPOL Annex I Examination · PII Safety Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3529980
17 April 2008 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3186326
24 April 2007 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2914606
17 November 2006 Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2823737
6 July 2006 ISPS II Exam · PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2689812
20 March 2006 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2605828
6 July 2005 PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2417020
15 June 2005 ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2391717
10 June 2005 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2400262
10 June 2005 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2406461
4 January 2005 PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2267148
29 June 2004 ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2113381
26 April 2004 Uninspected Other
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2053205
16 April 2003 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1811089
4 November 1996 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 397087
7 July 1993 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 649354
22 May 1993 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 122298
11 March 1993 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 643703
24 February 1993 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 46053
2 December 1992 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 643700
18 October 1992 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 34570

Deficiency record · 12

Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 2 February 2016 Resolved
A Safety Management Certificate shall be issued to every ship by the Administration or an organization recognized by the Administration. Vessel's SMC does not reflect new current owner/operator. SOLAS 74, IX/4.3 50 b/c
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 March 2016
Resolved 2 February 2016
Resolution: Operations manager provided copy of new interim certificate and provided to vessel.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 2 February 2016 Resolved
Update Vessel's Non Tank Vessel Response Plan to reflect new current owner/operator. 33CFR155 50c
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 March 2016
Resolved 2 February 2016
Resolution: Operations manager provided copy of NTVRP showing new owner/operator and provided to vessel.
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 2 February 2016 Resolved
Update vessel's Ballast Water Management Plan to reflect current owner/operator. 33CFR151 50c
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 March 2016
Resolved 2 February 2016
Resolution: Operations manager provided copy of new BWM and provided to vessel.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 14 January 2014 Resolved
9900 - All vessels equipped with ballast tanks, that operate in the water of the U.S. shall maintain, implement, and execute ballast water management. Vessel departs U.S. waters and Sector San [name withheld] zone every 29 days and therefore must maintain, implement, and execute ballast water management, including the removal of all fouling organisms on vessel's hull. - 33CFR151 Subpart D.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 February 2014
Resolved 18 February 2014
Resolution: a vessel specific Ballast Water Managment Plan was written and implemented.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 17 July 2013 Resolved
2555- Documentation- The company and ship shall comply with the ISM code. Objective evidence exists that the company has not provided measures to respond to emergencies. Company Fleet Safety Manual and Crew Safety Training Manual does not adequetly describe the proper procedures for activating fixed CO2 system for engine room. -SOLAS Ch. IX Reg 3
Action required: 705 - Other - as specified
Due 12 August 2013
Resolved 1 August 2013
Resolution: See RO report dated 31July2013 attached under MIDLE documents
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 28 June 2012 Resolved
2199 - Other (MARPOL) The ship shall be maintained to conform with convention to ensure ship is fit to proceed to sea wiothout presenting a threat to marine enviroment. When looking at OWS schematic, there is a valve required after check valve and before line from shaft alley bilge discharge. Vessel is not use OWS until valve has been installed. MARPOL 73/78 (2011 Cons) Annex I Reg 6.4.2
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2012
Resolved 1 August 2012
Resolution: Recieved Class Report attesting to instalation of valve on OWS system.
Documentation › Certificates/Documents › IOPP Certificate
Issued 28 June 2012 Resolved
0150 - When it is determined that a ship or it's equipment does not correspond substantially with the particulars of the certificate such surveyor or organization shall immediately rectify and notify the admin. Vessels IOPP lists the wrong approval for OWS, No Tanks are listed on IOPP, and IOPP certificate has improper OWS throughput listed. MARPOL 73/78 (2011 cons) Annex I Reg 6.4.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2012
Resolved 29 June 2012
Resolution: Received and reviewed the new revised IOPP approved by ABS. The revised IOPP was complete with all the necessary changes. IOPP is now valid.
Documentation › Logs/Records › Oil Record Book
Issued 28 June 2012 Resolved
1710 - Marine Pollution - The ORB Part I shall be completed on each occasion whenever a machinery space operation takes place. Cheif engineer is not recording machinery operations in the Oil Record Book. MARPOL 73/78 (2011 Cons) Annex I Reg 17.2 Code 16(c)
Action required: 705 - Other - as specified
Due 31 July 2012
Resolved 1 August 2012
Resolution: Verified that vessel was using new MEPC to fill out ORB.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 28 June 2012 Resolved
2500- Objective evidence exist that the vessels SMS does not adequately address the enviromental policy objectives stated in the ISM Code. Vessels procedures for discharge of liquid substances, Vessels review of oil record book, and valve missing from OWS show that surveys are not identifying non conformities with SMS. Recomend external audit of SMS by 3rd party. Solas CH IX Reg 3 and ISM Code A.2
Action required: 705 - Other - as specified
Resolved 1 August 2012
Resolution: Recieved class report stating no defs in SMS
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 19 October 2011 Resolved
19OCT2011: 1581 The exact position of the rudder shall be indicated at the principal steering station. Vessel does not have a rudder angle indicator at the principal steering station. SOLAS 60 Ch. 2 Reg. 29 (a)(iv)
Action required: 705 - Other - as specified
Due 2 November 2011
Resolved 9 November 2011
Resolution: Vessel painted rudder angles on the rudder
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 November 2010 Resolved
All electrical apparatuses shall be so constructed and sinstalled that danger of injury in ordinary handling does not exist. Vessel has dead end wires exposed on No.1 Generator and is using plastic zip ties to hold wires together. SOLAS60.CHAP ii/REG. 27
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 15 January 2011
Electrical › Lighting (service) › Lighting Fixture
Issued 15 November 2010 Resolved
After any survey of the ship no change shall be made in the structural arrangements, machinery, equipments covered by the survey, without the sanction of the administration. Vessel has plastic zipties supporlting wires throughout the engineroom.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 15 January 2011

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.