COMMANDER

COMMANDER is a 1977 freight ship. The Coast Guard has recorded 24 inspections since 2007, most recently in May 2012, along with 50 deficiencies — 1 with no resolution recorded — and 5 operational controls.

Records from 2007 to 2012. Most recent: inspection, 29 May 2012.

Built
1977
Last inspected
29 May 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7703235 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HP5771
933339
Flag
SAINT VINCENT AND THE GRENADINES
—
Maury page id
psix-933339

Inspections, by type

…with no type recorded3
…past their stated due date1
Years with a record 6 calendar years (2007–2012)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it993 - Convention (Subpart B), Gross Ton
298 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 7

Inspection history · 24

29 May 2012 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4328159
14 May 2012 ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4310816
23 September 2011 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4154275
18 August 2011 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4119466
20 January 2011 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3929717
10 December 2010 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3908305
2 December 2010 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3904113
25 October 2010 Random ISPS/MTSA/PSC
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3877447
16 October 2010 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3872684
13 September 2010 Deficiency Check · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3848728
10 September 2010 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3849112
11 March 2010 PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3694719
14 July 2009 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3534027
3 April 2009 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3447899
25 March 2009 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3439617
24 November 2008 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3368244
19 September 2008 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3328077
5 August 2008 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3289536
24 June 2008 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3246243
13 March 2008 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3163512
11 March 2008 ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3162976
17 January 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3135674
9 January 2008 Deficiency Check · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3124553
14 December 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3115746

Deficiency record · 50

Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 14 May 2012 Resolved
In sleeping rooms, an electric reading lamp shall be installed at the head of each berth PSCO discovered all sleeping rooms do not have reading lamps at the head of each berth. cite: ILO 147/PWSA, 33 USC 1223(b)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 May 2012
Resolved 29 May 2012
Resolution: Lamps at the head of each berth in use was installed with lighting.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 May 2012 Resolved
The absence or improper installation of built in guards or other protective devices such as railings, fencing, or shielding, for mounting parts of mechanical and electrical machinery and equipment presenting hazards to personnel. PSCO discovered the missing guard for the bench grinder in the engine room. Cite: ILO 147/PWSA, 33 USC 1223(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2012
Resolved 29 May 2012
Resolution: Bench grinder removed.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 2 December 2010 Resolved
Lifeboat is required to have rations for the capactiy of the lifeboat. The lifeboat capacity is 11 persons and the lifeboats only contain rations for 8 persons.
Action required: 705 - Other - as specified
Due 9 December 2010
Resolved 10 December 2010
Lifesaving › Lifeboat › Hull
Issued 2 December 2010 Resolved
Vessel is required to maintain lifeboats in a surveyable condition. Starboard lifeboat was found to have cracks in the fiberglass shell on the keel and the stability plate on the aft lowering device was found wasted. Vessel has Flag exemption from having lifeboats.
Action required: 705 - Other - as specified
Due 9 December 2010
Resolved 10 December 2010
Personnel › Certificates/Documents/Licenses › License, Second Assistant Engineer
Issued 13 September 2010 Resolved
Vessel does not meet its safe manning document. 2nd engineer could not provide his national license or flag state endorsement. The vessel does not have another crew member with the proper qualification available. SOLAS 74 CH V Reg. 14 CODE: 30 a, b, c
Action required: 17 - Rectify deficiencies prior to departure
Due 13 September 2010
Resolved 24 September 2010
Resolution: Vessel provided 2nd engineer''s valid national license and flag state endorsement.
Fire Fighting › Fire Main › Condition
Issued 13 September 2010 Resolved
During the deck walk portions of the examination the PSCO noted that the fire main is severely wasted and corroded more than 50% of the hose connections are not providing a seal. The equipment connector at the starboard side is completely inoperable. SOLAS 60 CH. 2 Part E Reg. 55 (e)(i) CODE: 30 a, b, c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 December 2010
Resolved 25 October 2010
Resolution: Firemain piping was renewed, including the firemain valves.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 13 September 2010 No resolution recorded
The vessels crew is not following Ch. 9 of the SMS. The vessel's crew is not notifying the operating company of the major non-conformities on firefighting, structural integrity, and navigation safety. In addition the vessel is still identified as a ferry while it is carrying out and is listed as a RO/RO vessel on the Class Doc. Requested to conduct an External ISM Audit. SOLAS 74 A CH IX/ REG 3
Action required: 17 - Rectify deficiencies prior to departure
Due 13 September 2010 — due date passed with no resolution recorded
Resolution: Vessel provided documentation from completed External ISM Audit.
Navigation › Piloting/Steering › Marine Charts
Issued 13 September 2010 Resolved
1560 Nautical charts and Notices to Mariners Shall be adequate and up to date. Charts necessary for the intended voyages have not been updated in accordance with Notice to Mariners since 2005. SOLAS 74 A. Ch. V Reg. 27 30 C
Action required: 705 - Other - as specified
Due 13 September 2010
Resolved 23 September 2010
Resolution: Vessel had new charts for the Port of San Juan with corrections
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 13 September 2010 Resolved
Improper installation of the wiring harness on the overhead in the bridge is incorrectly sealed causing water to leak onto CMDSS equipment. Condition poses a serious electrical hazard to personnel and equipment. SOLAS 60 Ch. II, Part C Reg. 27(a)(vi) 17ab
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 13 September 2010
Resolved 23 September 2010
Resolution: Vessel sealed hole and wires with caulk.
Deck/Cargo › Cargo Stowage › General
Issued 13 September 2010 Resolved
During the documentation portion of the exam the PSCO noted that the Cargo Securing Manual does not include the particulars on how to secure its cargo on this vessel. As a result, vessel is not securing its cargo properly. Vessel is to provide a complete cargo securing manual to the satisfaction of the Administration. SOLAS 74 A. Ch.. VI Reg. 5.6 17abc
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 January 2011
Resolved 20 January 2011
Resolution: Cargo Securing Manual has included the particulars on how to secure its cargo on the vessel.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 13 September 2010 Resolved
During the documentation portion of the exam the PSCO noted that the crew list included in the ANOA does not match the crew on board. A 2nd Engineer came on board the vessel yesterday, 12 SEP2010 but the ANOA was not updated. Coast Guard provides training to crew about the ANOA requirements. 33CFR160.206 10c
Action required: 705 - Other - as specified
Due 13 September 2010
Resolved 13 September 2010
Resolution: Coast Guard provides training to crew about the ANOA requirements.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 13 September 2010 Resolved
DURING THE DECK WALK PORTION OF THE EXAM THE PSCO NOTED A SHARP DENT AT ABOUT MIDSHIP STARBOARD SIDE. UPON CLOSE EXAMINATION THE BULKHEAD WAS FOUND CRACKED AND CORRODED. VESSEL IS TO MAKE PROPER REPAIR TO THE VESSELS HULL PRIOR TO DEPARTURE. ICLL 66 PART 151 17 AB
Action required: 705 - Other - as specified
Due 13 September 2010
Resolved 24 September 2010
Resolution: Vessel provided report of repair from San Juan Towing attesting to the replacement of 55 square feet of side shell and deck plate. Class provided report attesting to the repairs being satisfactory. CG confirmed repairs were made.
Construction/Loadline › Hull › Longitudinal Frame
Issued 13 September 2010 Resolved
DURING THE DECK WALK PORTION OF THE EXAM THE PSCO NOTED SEVERAL CRACKS ON THE TOP OF THE WING BALLAST TANKS SIX TO SEVEN INCHES PORT AND STARBOARD SIDES. VESSEL IS TO CONDUCT PROPER REPAIRS TO THE SATISFACTION OF THE CERTIFICATE ISSUING AUTHORITY. -CODE: ICLL 66 PART 15 16 AB
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 December 2010
Resolved 25 October 2010
Resolution: The repair to starboard side wing tank was repaired.
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 13 September 2010 Resolved
VESSEL CURRENTLY HAS LIFSAVING EXEMPTION FOR THEIR LIFEBOATS. VESSEL STILL HAS BOTH LIFEBOATS WITH ITS EQUIPMENT IN DISREPAIR ON BOARD. USCG IS REQUESTING CLARIFICATION FROM THE CERTIFICATE ISSUING AUTHORITY AS TO WHAT CONDITION THE EXEMPTED EQUIPTMENT THAT IS ON BOARD IS TO BE KEPT AT. -17ABC
Action required: 705 - Other - as specified
Due 13 October 2010
Resolved 2 December 2010
Resolution: Vessel removed lifefloats from vessel and serviced the lifeboats.
Construction/Loadline › Hull › Hull Plating
Issued 13 September 2010 Resolved
DURING THE STEERING GEAR ROOM PORTION OF THE EXAM THE PSCO NOTED THAT THERE IS A GASH 3 to 4 INCHE FROM THE SPACE TO THE OUTSIDE OF THE VESSEL NEAR THE HOUSE PIPE. VESSEL IS TO CONDUCT PROPER REPAIRS TO THE HULL PRIOR TO DEPARTURE. -ICLL 66 PART 15/ 17ABC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2010
Resolution: Vessel provided report of repair from San Juan Towing attesting to the repair of the port anchor chain locker. Class provided report attesting to the repairs being satisfactory. CG confirmed repairs were made.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 13 September 2010 Resolved
DURING THE NAVIGATION PORTION OF THE INSPECTION THE PSCO NOTED THAT THE VESSEL IS MISSING THE NAVIGATION RULES OF THE ROAD PUBLICATION. VESSEL IS TO HAVE ON BOARD A COPY OF THE NAVIGATIONAL RULES PRIOR TO DEPARTURE. 33CFR88.05 17C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2010
Resolution: Vessel received Navigation Rules of the Road and showed team the publication is located on the bridge.
Stability › Weathertight Integrity › General
Issued 13 September 2010 Resolved
UPON EXAMING THE STRUCTURAL INTEGRITY OF THE VESSEL THE PSCO NOTED THAT THE BOW LOAING HATCH IS NOT WEATHERTIGHT. THE SEALING MECHANISMS ARE SEVERLY CORRODED AND WASTED. VESSEL IS TO MAKE PROPER REPAIRS TO HATCH PRIOR TO DEPARTURE. ICLL 66 CH.2 REG.12.1 17 AB
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 September 2010
Resolved 24 September 2010
Resolution: Vessel provided documentation that San Juan Towing repaired the bow loading ramp. Class provided report attesting to repairs. CG attended vessel and confirmed repairs were made.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 13 September 2010 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 13 September 2010
Resolved 24 September 2010
Resolution: Vessel obtained copy of non tank VRP on board.
Fire Fighting › Fire Hoses › Condition
Issued 13 September 2010 Resolved
Vessel required to have operational fire hoses and nozzles. Aft STBD fire hose was found wasted and nozzle frozen. Ensure all hoses have nozzles and are in operational condition. SOLAS 60 Ch. 2 Part E Reg. 55(f) 40C
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2010
Resolved 14 September 2010
Resolution: Deficiency combined with fire main degredation.
Fire Fighting › Fire Main › Condition
Issued 13 September 2010 Resolved
Based upon the wasted condition of the vessels fire main the vessel shall remove all dangerous goods cargo. 33USC1223(b)
Action required: 705 - Other - as specified
Due 13 September 2010
Resolved 24 September 2010
Resolution: Vessel provided report of repair from San Juan Towing attesting to the change of 220 linear feet of fire main. CG inspectors attended the vessel and preformed operational test of the fire system which was found to be satisfactory.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 11 March 2010 Resolved
2155 Vessels > 65ft operating in US waters with installed toilet facilities shall be equipped with an operable Type II or III marine sanitation device. Vessels sewage plant is inoperable. Vessel shall repair equipment to satisfaction of class. 40AC
Action required: 705 - Other - as specified
Due 8 April 2010
Resolved 17 April 2010
Resolution: Vessel replaced seized pump on MSD that is reported by the vessel Captain to have been the problem.
Lifesaving › Lifebuoys › Serviceable
Issued 11 March 2010 Resolved
0650 Lifebuoys made of plastic or other synthetic compounds shall be capable of retaining their buoyant properties. Forward lifebuoys on bridge deck are severly deteriorated. Replace to the satisfaction of USCG.
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 31 March 2010
Resolution: Life bouys on bridge deck have been replaced.
Fire Fighting › Fire Hoses › Condition
Issued 11 March 2010 Resolved
0710 Vessel shall replace deteriorated fire hose used to connect emergency portable fire pump to fire main to satisfaction of USCG. 16C
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 31 March 2010
Resolution: New fire hose and connections from pump to fire main were on board.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 11 March 2010 Resolved
0899 Vessel shall maintain nonslip surfaces in working areas on & below decks. Bridge deck was found extremely slippery when wet. Vessel shall provide non slip materials for deck throughout vessel. 50AC
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 17 April 2010
Resolution: Coast Guard inspectors atteneded vessel and verified that all working surfaces had been painted with a non slip surface paint.
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 11 March 2010 Resolved
0330 All wash spaces shall provide cold & hot fresh water for crew. Hot water is not available in all wash spaces. 50C
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 17 April 2010
Resolution: Vessel installed local water heater in wash spaces providing hot water.
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 11 March 2010 Resolved
0199 All SOLAS certificates on board shall reflect if exemption certificates have been provided. 16ABC
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 17 April 2010
Resolution: Vessel captain explained that class told him that because the certificates are interim they do not mark out the phrase reflecting if exemptions have been provided.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 25 March 2009 Resolved
0135-Failure to comply with the applicable minimum safe manning requirements of the Administration. Provide sufficient officers/seafarers to meet minimum requirements of the Safe Manning Cerificate. STCW 95 I/14-1.2
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 March 2009
Resolved 26 March 2009
Resolution: Received proper minimum safe manning document. Vessel now meets the minimum requirements. No second engineer or deck officer required according to new cert.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 March 2009 Resolved
1730-OWS found inoperable on last PSC exam on Sep08. Def issued with due date of Jan 31 09. During recent exam on 25 Mar 09, found OWS still inoperable. Vessel shall submit Vessel stated that new system has been received in ST. Thomas and ready for installment prior to departure. MARPOL Annx I Part B Reg 14
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 March 2009
Resolved 4 April 2009
Resolution: Examined new installation and witnessed operational test.
Fire Fighting › Fire Main › Valves
Issued 19 September 2008 Resolved
0720 - Vessel is required to have working hydrants placed along the starboard side of the vessel. The third hydrant from the bow on the starboard side has a broken valve. Replace/repair the broken valve to the satisfaction of class.
Action required: 705 - Other - as specified
Due 3 October 2008
Resolved 24 November 2008
Resolution: Received class report all hydrants tested during class survey conducted on 11 Nov. to 13 Nov. 2008 all found in good order.
Fire Fighting › Nozzles › Condition
Issued 19 September 2008 Resolved
0720 - Vessel is equipped with two emergency fire pumps. Nozzle for the hose to the portable emergency fire pump is broken. Repair/replace to the satisfaction of class.
Action required: 705 - Other - as specified
Due 3 October 2008
Resolved 24 November 2008
Resolution: The new portable fire pump was arranged so that it could be hooked up to any hydrant on the main deck and supply water to any hydrant on the vessel. [name withheld], Chief Engineer, and Chief Mate were advised that old fire pump has to be removed from vessel
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 19 September 2008 Resolved
1730 - Vessel is fitted with an OWS with alarm and automatic stopping device per their International Oil Pollution Prevention Certificate, issued by the International Naval Surveys Bureau. OWS on board has been out of service since 08FEB08 and non-conformity report has been submitted to the company. Vessel shall repair/replace equipment to the satisfaction of class.
Action required: 705 - Other - as specified
Due 31 January 2009
Resolved 4 April 2009
Resolution: Examined new installation and witnessed operational test.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 19 September 2008 Resolved
1510 - Vessel's NAVTEX is inoperable. Equipment prints out satisfactory test results, but is unable to receive any international NAVTEX service broadcasts. Repair to the satisfaction of the administration.
Action required: 705 - Other - as specified
Due 3 October 2008
Resolved 24 November 2008
Resolution: Navtex checked by Boyce Electronics Limited and found the receiver damage. Installed new navtex, battery found defective and replaced. Incorrect cable used between control and NBDP replaced with correct by changing the wiring connection the 9 pin plug.
Operations/Management › Drills/Instruction › Fire
Issued 19 September 2008 Resolved
0190 - Vessel has failed to record fire and boat drills since May 2008. Satisfactory drills were conducted with PSCO's on board and crew showed proficiency in fighting the fire and mustering in accordance to the vessel's plans. Master received guidance on proper recording procedures. The deficiency was corrected on the spot to the satisfaction of the Coast Guard.
Action required: 705 - Other - as specified
Due 19 September 2008
Resolved 19 September 2008
Resolution: Deficiency was corrected on the spot to the satisfaction of the Coast Guard.
Documentation › Logs/Records › Oil Record Book
Issued 19 September 2008 Resolved
1710 - Vessel's oil record book part 1 is missing Master's signature for each completed page. PSCO advised Master of proper entry procedures. The deficiency was corrected on the spot to the satisfaction of the Coast Guard.
Action required: 705 - Other - as specified
Due 19 September 2008
Resolved 19 September 2008
Resolution: The deficiency was corrected on the sport to the satisfaction of the Coast Guard.
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 13 March 2008 Resolved
ISM plan on board is missing approval letter/stamp. Provide approval to the satisfaction of USCG.
Action required: 705 - Other - as specified
Due 26 March 2008
Resolved 27 March 2008
Resolution: approved plan on board
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 11 March 2008 Resolved
Both Shaft seals are leaking excessively. vessel is to make proper repairs to the satisfaction of the administration.
Action required: 705 - Other - as specified
Due 27 April 2008
Resolved 5 August 2008
Resolution: Received letter from Administration attesting to proper repairs
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 11 March 2008 Resolved
emergency fire pump is only producing 1-2 bar pressure and was unable to adequately pressurize 2 hoses. Vessel is to ensure that the Emergency Fire Pumping arrangements meet the approval of the administration.
Action required: 705 - Other - as specified
Due 27 April 2008
Resolved 5 August 2008
Resolution: Received letter from Administration attesting to proper repairs
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 4 January 2008 Resolved
Master, Chief Mate, and Chief Engineer are not able to provide STCW endorsements for the U.S. Coast Guard officers on boarding.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2008
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 4 January 2008 Resolved
Vessel does not have licenced chief engineer onboard as per the requirements of their Minimum Safe Manning Doccument.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2008
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 4 January 2008 Resolved
Vessels crew are not able to provide Medical Fitness Docs.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2008
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 4 January 2008 Resolved
Vessel oes not have an approved Ballast Water Management Plan.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2008
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 4 January 2008 Resolved
Vessel does not have oil transfer procedures onboard.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2008
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 4 January 2008 Resolved
Vessel does not have an approved Vessel Response Plan on board
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2008
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 January 2008 Resolved
Crew is unable to demonstrate the proper operation of the Oily Water Separator.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2008
Documentation › Logs/Records › Oil Record Book
Issued 4 January 2008 Resolved
Vessels Oil Record Book is not up to date and several entries have not been entered.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2008
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 4 January 2008 Resolved
The master and officers are not familiar with the safety managment system and the planned arrangements for its implementation.
Action required: 705 - Other - as specified
Due 3 February 2008
Resolved 12 March 2008
Resolution: Master and officers demonstrated sufficient knowledge of safety management system.
Construction/Loadline › Markings › Load Line Mark
Issued 4 January 2008 Resolved
vessels loadline is not in accordance with International Loadline Certicicate. Deck line and seasonal markings are missing. Lettering is not perminately affixed.
Action required: 705 - Other - as specified
Due 3 February 2008
Resolved 12 March 2008
Resolution: Loadline is now in accordance with the International Loadline Certificate.
Lifesaving › Rocket Parachute Flares › General
Issued 4 January 2008 Resolved
Vessel does not have 12 rocket parachute flares. 06 are onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2008
Fire Fighting › International Shore Connection › Not on Board
Issued 4 January 2008 Resolved
vessel does not have international shore connection on board. crew members were unable to determine presence of international shore connection and accessories.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2008
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 4 January 2008 Resolved
Vessel does not have an approved fire control paln onboard. current plan has missing, incorrect appliances and equipment listed.
Action required: 705 - Other - as specified
Due 3 February 2008
Resolved 27 March 2008
Resolution: approved plan is on board.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.