Records from 1985 to 2015. Most recent: inspection, 8 April 2015.
Inspection history · 30
8 April 2015
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 5099196
6 January 2014
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4772745
16 August 2009
PII Safety Exam · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3569171
5 February 2008
PII Safety Exam · Deficiency Check · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3141862
27 October 2006
Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2809571
10 April 2006
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2621340
3 April 2006
ISPS II Exam · PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2615706
3 November 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2237212
15 September 2004
PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2196138
29 September 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1916224
9 July 2003
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1840420
27 July 2000
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 280413
12 May 2000
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 277797
4 December 1999
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 158895
29 November 1999
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 515456
25 June 1999
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 430081
27 July 1998
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 418567
4 June 1997
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 454070
5 March 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 401160
9 August 1996
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 47939
12 May 1996
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 118857
3 October 1995
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 383446
8 August 1995
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 712598
20 June 1995
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 647480
19 June 1995
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 379662
9 May 1995
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 112803
27 February 1987
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 314588
11 March 1986
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 307454
1 June 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 302324
21 May 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 494639
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 8 April 2015
Resolved
1730 Oil Filtering Equipment shall be of a design approved by the Administration and shall be as such as will ensure that any oily mixturedischarged into the sea after passing through the system has an oil content not exceeding 15 ppm. Throughput was incorrect due to inadequate pump. Vessel will install the correct pump to manufacturer's specification prior to departure. MARPOL Annex I Reg 14.6 17
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2015
Resolved 16 April 2015
Resolution: Vessel installed new pump. PSCOs verified pump specifications compared to OWS unit and found satisfactory. Verified operation of pump and unit as adequate for departure and intended transit. Informed Master to notify Class of pump changeout.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 August 2009
Resolved
1730
REQUIRED OILY WATER SEPERATOR WAS INOPERABLE DUE TO FAILURE OF OIL/WATER INTERFACE MONITORING SYSTEM.
MARPOL 74/78 ANNEX I REG 14.1
70C
Action required: 15 - Rectify deficiencies by next port
Due 17 August 2009
Resolved 7 January 2014
Resolution: OWS inspected and is operating properly.
Engineering › Steering Gear System › Motor
Issued 27 October 2006
Resolved
Ship's starboard steering motor failed, both steering gears are fully operational with the port steering gear motor. Vessel is towing the BOABARGE 7 which is unmanned, submersible deck barge that is empty. Vessel is to proceed directly to Gulf Cooper Shipyard Galveston, TX. Repairs are to be made to the satisfaction of the Certificate Issuing Authority. Vessel is to provide a report from the C
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2006
Resolution: Received Class Survey Report from ABS stating that Aft #2 steering pump electric drive motor was repaired, tested, and considered satisfactory. Vessel remains within class.
Construction/Loadline › Structures › Air Pipe
Issued 5 April 2006
Resolved
The air pipe for the sludge tank is severely corroded with a large hole at the base. The corroded condition of the pipe allows water to flood the sludge tank. Make necessary repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 February 2008
Resolution: The air pipe for the sludge tank that had a large hole at the base was properly repaired.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 5 April 2006
Resolved
There is evidence of oil in the OWS discharge piping after the oil content meter. Suspect vessel of improper operation of the OWS. Prove proper operation.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 5 February 2008
Resolution: A new OWS was installed and certified by classification society.
Lifesaving
Issued 5 March 1997
Resolved
SOLAS 60 III/20(a): PORT AND STBD LIFEBOATS MISSING REFLECTIVE TAPE ON HULL BOTTOMS. CORRECT NOT LATER THAN 06MAY97.
Condition: Unknown
Due 4 June 1997
Resolved 4 June 1997
Electrical
Issued 5 March 1997
Resolved
ICLL 66/25: REPAIR ELECTRICAL STUFFING TUBES AT DECK LEVEL IN VICINITY OF STARBOARD STACK AND PORT ENGINE ROOM VENT. CORRECT NOT LATER THAN 06MAY97.
Condition: Unknown
Due 4 June 1997
Resolved 4 June 1997
Lifesaving
Issued 5 March 1997
Resolved
SOLAS II-2/17.3: PROVIDE TWO FIREFIGHTING OUTFITS OR SUITS FOR SCBAS. CORRECT NOT LATER THAN 06MAY97.
Condition: Unknown
Due 4 June 1997
Resolved 4 June 1997
Documentation
Issued 19 June 1995
Resolved
VESSEL ATLANTIC HICKORY CHANGED NAMES ON 25APR95 CERTIFICATE OF FINANCIAL RESPONSIBILITY #104125-06, EXP. 11DEC97 STILL READS OLD VESSEL NAME IRVING MIAMI. CALL TO COFR DESK CONFIRMED NO ATTEMPT TO CHANGE CERTIFICATE. CERTIFICATE IS INVALID.
Condition: Unknown
Due 3 October 1995
Resolved 3 October 1995