MAURY USCG vessel records Sign in
← All vessels

CAPE TRINITY

CAPE TRINITY is a 1977 freight ship. The Coast Guard has recorded 97 inspections since 1987, most recently in November 2025, along with 99 deficiencies, 1 operational control and 6 casualty investigations between 2013 and 2024.

Records from 1987 to 2025. Most recent: inspection, 18 November 2025.

Built
1977
Last inspected
18 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7602259 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225752
Flag
PANAMA
366838000 (licence lapsed)
Maury page id
psix-225752

Inspections, by type

…with no type recorded22
Years with a record 33 calendar years (1987–2025)
The 97 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)596.5 ft × 88.6 ft × 57.7 ft
Registered tonnagegross 21,782 / net 6,534
ITC dimensions (L × B × D)596.5 ft × 88.6 ft × 57.7 ft
ITC tonnagegross 21,782 / net 6,534
BuilderHOWALDTSWERKE DEUTSCHE · KIEL, GERMANY · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNORFOLK, VA
Trade endorsementsRegistry
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21782 - Convention (Subpart B), Gross Ton
6534 - Convention (Subpart B), Net Ton
15075 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

KAFDMMSI 366838000 · expired · compulsorily equipped · granted 9 December 1993, cancelled 9 December 1998
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPE TEXAS Freight Ship · MISLE 51597 · 28 October 2017 · activity 6298333FLORIDA Tank Barge · MISLE 52666 · 17 June 1992 · activity 62108HELEN Towing Vessel · MISLE 137952 · 17 June 1992 · activity 62108

Inspection history · 97

18 November 2025 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8270595
4 December 2024 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8043204
31 July 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7971182
15 May 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7914866
14 May 2024 Type not recorded
No type recorded · Activities Europe · Activity 7943373
2 May 2024 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7906253
30 November 2023 Re-Inspection · Deficiency Check · COI Inspection · ACP COI Oversight · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7826115
23 February 2023 Annual Inspection · Deficiency Check · ACP Annual Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7639423
8 September 2022 ACP Additional Oversight – Risk Assessment · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7543507
16 March 2022 MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7413131
21 January 2022 Deficiency Check · ACP Periodic Oversight · Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7383735
27 August 2021 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7300221
23 February 2021 MTSA/ISPS Verification · ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7096392
8 February 2021 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7137462
19 November 2019 ACP Drydock Oversight · Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6858461
25 September 2019 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6820597
21 August 2019 COI Inspection · MTSA/ISPS Verification · ACP COI Oversight · Re-Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6783005
14 February 2019 In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6625881
14 November 2018 MTSA/ISPS Verification · ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6580375
28 September 2018 In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6551154
28 October 2017 Damage Survey
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6296558
28 October 2017 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6298333
22 October 2017 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6290182
10 October 2017 MTSA/ISPS Verification · Periodic Inspection · ACP Periodic Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6279884
20 December 2016 Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6058904
7 January 2016 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5792029
17 November 2015 ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5760432
20 August 2014 MTSA/ISPS Verification · ACP COI Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4953965
15 December 2011 MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4208978
22 September 2011 ACP Annual Oversight
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4151858
23 August 2011 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4124532
17 December 2010 MARPOL Annex I Examination · ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3912472
11 February 2009 MARPOL Annex I Examination · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3416213
14 November 2007 MTSA/ISPS Verification · ACP Annual Oversight · MARPOL Annex I Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3098105
3 January 2007 ACP COI Oversight · MTSA/ISPS Verification · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2849675
3 October 2006 Re-Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2792661
22 March 2006 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2607725
15 December 2005 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2578942
2 December 2005 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2544566
4 November 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2528368
15 September 2005 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2493094
13 April 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2473070
16 December 2004 MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2260054
20 August 2004 COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2130090
26 July 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2145443
18 June 2004 MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2102746
14 February 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2016447
12 February 2004 In-Service Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2008419
7 February 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2013092
28 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1995729
8 October 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1924729
14 August 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1876448
28 January 2003 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1736580
13 December 2002 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1718569
15 November 2002 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1708894
8 July 2002 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1645562
7 September 2001 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1366536
8 February 2001 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1059503
8 January 2001 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 825320
17 August 2000 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1395522
23 September 1999 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1438924
30 August 1999 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1444217
20 August 1999 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1114232
6 August 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 21535
8 January 1999 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 809697
17 December 1998 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 808029
21 September 1998 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 798906
10 September 1998 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 804614
3 September 1998 Drydock Extension
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1388604
20 August 1998 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1400833
14 April 1998 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 788383
13 January 1998 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 776883
28 August 1997 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1438633
10 July 1997 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1114355
21 March 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1467001
10 January 1997 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1096453
23 December 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1096455
10 December 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1092483
10 September 1996 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1371590
9 September 1996 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 946270
5 July 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1086538
7 December 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1405817
23 August 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 873433
18 July 1995 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1186107
12 January 1995 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1173098
3 December 1994 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 181525
18 November 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 869066
15 November 1994 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 862161
14 September 1993 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 849589
17 March 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1359504
17 June 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 62108
17 June 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 171586
16 June 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 461137
22 July 1991 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 447654
12 May 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 462540
4 October 1990 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 339692
24 March 1987 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 315048

Deficiency record · 99

04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 February 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons onboard. Inspectors observed that the forward cargo hold escape hatch light was burnt out. 74SOLAS(20) Ch. I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2023
Resolved 23 March 2023
Resolution: Received ABS Preliminary Report. 5742278
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 23 February 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons onboard. Inspectors observed the cargo ramp motor controller disconnect switch was in disrepair. 74SOLAS(20) Ch. I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2023
Resolved 23 March 2023
Resolution: Received ABS Preliminary Report. 5742278
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 8 September 2022 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. All four line throwing appliances on the vessel are expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 September 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. During routine thermographic inspection conducted Sept 2021, LA25 Cargo Fan had a 20 degree C rise and was indicated to be repaired as soon as possible. Vessel management had not yet repaired equipment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 2 February 2022 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessel’s open lifeboats showing signs of deterioration The engine cover bolts are missing. There are some damaged areas of fiberglass above the waterline and the step to get into lifeboats are rotted at the bottom. The retroactive tape is missing and/or is an unapproved type. Vessel to repair to the satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2022
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 February 2022 Resolved
Firefighting systems and appliances shall be kept in good working order and readily available for immediate use. Fire main is leaking in numerous spots on the vessel, leaks are on both the piping and at various fire stations. Vessel to hydrostatically test fire main and identify areas where repairs are necessary.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 February 2022 Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions shall be kept in good order so as to ensure their required performance if a fire occurs. Throughout the cable trunks in the accommodation spaces, vessel is utilizing an unknown material to maintain fire boundaries. Vessel to provide proof that material is approved for the associated fire boundary.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 February 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 February 2022 Resolved
All exposed metal parts of electrical machines or equipment which are not intended to be “live”, but are liable to become “live” under fault conditions, shall be earthed (grounded); and all electrical apparatus shall be so constructed and so installed that danger of injury in ordinary handling shall not exist. Electrical wiring in bridge deck battery room and “C” deck #94 electrical storage locker had improperly cut wiring leaving ends exposed thus causing a potential hazardous condition. Vessel shall terminate wires properly.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 February 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 2 February 2022 Resolved
he normal equipment of every lifeboat shall consist of: a food ration, determined by the Administration, for each person the lifeboat is certified to carry. These rations shall be kept in airtight receptacles which are to be stowed in a watertight container. 19 food ration receptacles were discovered to not be airtight. Vessel shall replace food rations necessary for each person the lifeboats are certified to carry.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 February 2022
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 2 February 2022 Resolved
he company should identify equipment the operational failure of which may result in hazardous situations. The SMS should provide for specific measures aimed at promoting the reliability of such equipment. In the current configuration, the ME standby cooling water pump does not provide timely/adequate cooling water pressure to the MEs before shutdown process is commenced. This would causes the vessel to lose both MEs when the primary pump unexpectedly stops working. Create specific measure to promote the reliability / eliminate the current problem.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 February 2022
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 2 February 2022 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Prior to activation, vessel must conduct fire and abandon ship drills and put all safety gear at location to the satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2024
Resolution: Vessel fully crewed and conducted fire and abandonship drill. Checked safety gear all sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 August 2021 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power. At the primary lifesaving muster stations, both port and starboard, the emergency lighting does not work.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 27 August 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. Vessel missing window on house by stbd lifeboat.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 27 August 2021
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 27 August 2021 Resolved
Fire-fighting appliances shall be maintained ready for use. During fire drill crew member was unable to go on air because mask he wore was not the correct style to hook into mouth piece.
Action required: 10 - Deficiency Rectified
Resolved 27 August 2021
08 - Alarms › N/A - No Subsystem › General alarm
Issued 23 February 2021 Resolved
The minimum sound-pressure levels for the emergency-alarm tone in interior and exterior spaces must be a sound level of not less than 75 dB(A) measured at 10 feet on the axis; and (2) At least 10 dB(A) measured at 10 feet on the axis, above background noise level when the vessel is underway in moderate weather unless flashing red lights are used in accordance with 46CFR113.25-10(b). Working areas throughout the engine room were unable to hear the audible general alarm when no visual alarm indicators were present and various audible bells were not louder than the background noise created by the generators.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2021
Resolved 17 March 2021
Resolution: Vessels classification society accepted deficiency and provided finding number. Closed.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 23 February 2021 Resolved
Fire control plans shall be kept up to date; any alterations thereto shall be recorded as soon as practicable. Vessel installed a workbench blocking an entry door that is required to be cleared/accessible in in accordance to their current Fire Control Plan. II-2/15.2.4.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2021
Resolved 17 March 2021
Resolution: Vessels classification society accepted deficiency and provided finding number. Closed.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 23 February 2021 Resolved
Where the emergency source of electrical power is a generator, it shall be: started automatically upon failure of the main source of electrical power supply unless a transitional source of emergency electrical power in accordance with paragraph 3.1.3 is provided; where the emergency generator is automatically started, it shall be automatically connected to the emergency switchboard. The crew places their emergency generator in manual mode impending the equipment to start and connect to the emergency switchboard. II-1/43.3.1.2
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2021
Resolved 17 March 2021
Resolution: Vessels classification society accepted deficiency and provided finding number. Closed.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 23 February 2021 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements, which may be established by the company. The crew could not provide ISM/SMS procedures for the emergency generator operations. SOLAS73(14)IX/3 ISM Code Ch.10.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2021
Resolved 17 March 2021
Resolution: Vessels classification society accepted deficiency and provided finding number. Closed.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 23 February 2021 Resolved
The voyage data recorder system, including all sensors, shall be subjected to an annual performance test. Vessel’s VDR was not subject to an annual performance test in 2020. SOLAS 74(14) V/18.8
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2021
Resolved 17 March 2021
Resolution: Vessels classification society confirmed survey carried out 24FEB21, all found sat. Finding number issued; CLOSED
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 23 February 2021 Resolved
Every crew member shall participate in at least one abandon ship drill and one fire drill every month. Vessel has not conducted drills due to crew levels, and is required to conduct drills prior to departure. SOLAS 74(14) III/3.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2021
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 21 August 2019 Resolved
alarms not able to be cleared on the bridge
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2019
Resolved 13 October 2019
Resolution: Cleared, Class issued requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 21 August 2019 Resolved
stbd side crack in the rudder stock and port crack in the keel and wasted rudder post hinge.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2019
Resolved 13 October 2019
Resolution: Cleared. Class issued requirement.
Construction/Loadline › Hull › Hull Plating
Issued 28 October 2017 Resolved
Damaged by collision
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 October 2017
Resolved 15 May 2018
Resolution: All items were repaired to the satisfaction of the attending surveyor.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 10 October 2017 Resolved
Vessel failed to conduct required drills
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2017
Resolved 22 October 2017
Resolution: Vessel conducted fire drill in the paint stores and abandon ship. All sat.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 10 October 2017 Resolved
Found all lifejacket light expired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2017
Resolved 22 October 2017
Resolution: Vessel replaced all life jacket lights.
Lifesaving › Lifeboat › Markings
Issued 10 October 2017 Resolved
Found all retroflective tape on lifeboats unsatisfactory.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 22 October 2017
Resolution: Vessel replaced all retro-reflective tape on both port and starboard life boats.
Operations/Management › Drills/Instruction › Not Conducted
Issued 17 November 2015 Resolved
Vessel is to conduct drills prior to departture.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 November 2015
Resolved 22 October 2017
Resolution: Vessel conducted fire drill in the paint stores and abandon ship. All sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 17 November 2015 Resolved
Evacuation and discharge timers not operating as designed on low pressure CO2 system. Prove proper operation of low pressure CO2 system.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 17 December 2015
Resolved 21 January 2016
Resolution: Witnessed operational test
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 August 2014 Resolved
Complete drills prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 November 2014
Resolution: Conducted satisfactory drills.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 11 February 2009 Resolved
Port Lifeboat hand crank starting system fails to CONSISTANTLY start.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2009
Resolved 11 September 2009
Navigation › Collision/Grounding Avoidance › Radar
Issued 11 February 2009 Resolved
Ships 10cm Radar display is not functioning properly. Image appears in conical pattern.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 February 2009
Resolved 11 September 2009
Resolution: Sighted radar display; satisfactory.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 February 2009 Resolved
Emergency Power to GMDSS not functioning.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 February 2009
Resolved 11 September 2009
Resolution: Sighted and functionally tested battery back-up; satisfactory.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 2 December 2005 Resolved
Prove that the STBD Generator will overspeed trip at 110 percent of rated speed.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 February 2006
Resolved 22 March 2006
Resolution: Witnessed satisfactory overspeed test of stbd generator. Cleared deficiency.
Engineering › Steering Gear System › Actuator
Issued 2 December 2005 Resolved
The steering gear hunts at 35 degrees STBD rudder on both pumps.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 February 2006
Resolved 22 March 2006
Resolution: Tested steering gear, cleared deficiency.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 2 December 2005 Resolved
The port steering gear disconnect failed to operate properly.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 February 2006
Resolved 22 March 2006
Resolution: Witnessed satisfactory repair and operation of steering gear disconnect. Cleared deficiency.
Engineering › Steering Gear System › Feedback Unit
Issued 2 December 2005 Resolved
Prove proper operation of alarms for port steering gear motor.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 February 2006
Resolved 22 March 2006
Resolution: Tested steering gear alarms, cleared deficiency.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 2 December 2005 Resolved
Provide servicing reports for fire detection, alarms, and annual servicing.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 February 2006
Resolved 22 March 2006
Resolution: Reviewed reports, cleared deficiency.
Lifesaving › Inflatable Liferafts › Servicing
Issued 2 December 2005 Resolved
Upon completion of liferaft servicing, provide service reports.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 January 2006
Resolved 13 January 2006
Resolution: Observed servicing reports, cleared deficiency.
Lifesaving › Launching Appliances › Davit
Issued 15 September 2005 Resolved
Conduct lifeboat davit weight test.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 January 2006
Resolved 22 March 2006
Resolution: Witnessed satisfactory weight tests and release under tension of port and stbd lifeboats. Cleared deficiency.
Pollution Prevention/Response › Prevention Equipment
Issued 8 October 2003 Resolved
Provide operational test of the OWS. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 7 November 2003
Resolution: Cleared by [name withheld].
Lifesaving › Liferaft Equipment
Issued 8 October 2003 Resolved
Provide life raft servicing certificate.
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 7 November 2003
Resolution: Cleared by [name withheld].
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 8 October 2003 Resolved
Provide fixed fire servicing cert.
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 7 November 2003
Resolution: Cleared by [name withheld].
Electrical › Electrical Distribution System (service)
Issued 8 October 2003 Resolved
Locate steering gear ground (440 system). LEGACY COMPONENT DESC: Ground Detection
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 7 November 2003
Resolution: Cleared by [name withheld].
Engineering › Gasoline Engine (auxiliary)
Issued 8 October 2003 Resolved
Provide operational test of the emergency generator.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 19 December 2003
Resolution: Cleared by [name withheld].
Electrical › Electric Generation Source (emergency) › Generator
Issued 8 October 2003 Resolved
To accom sea trials for the vsl scheduled during the week of 10NOV-14NOV, a secondary means to provide ship's power of vital syst must be provided. Design/electrical circuitry (tied into emergency bus) for the containerized temporary generator must be approved by class society before vsl departs.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2003
Resolved 11 November 2003
Resolution: ABS attended the vessel and conducting a full operational test on the temporary diesel generator, including emerg shutdown, overspeed, low lube oil, high jacket water temp, automatic start, and all vital emerg systems as installed. Found satisfactory.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 8 October 2003 Resolved
2nd low press CO2 Fixed Fire Ext Syst Tank to be hydrostatically pressure tested no later than vessel's next scheduled drydock (30AUG2004). Provide necessary paperwork attesting to the same sent to [name withheld] upon completion. LEGACY COMPONENT DESC: Tanks
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 15 September 2004
Fire Fighting › Ventilation Systems › Ducts
Issued 8 October 2003 Resolved
Repair port side fire damper in way of tower louver.
Condition: Unknown
Due 1 November 2003
Resolved 7 November 2003
Resolution: Cleared by [name withheld].
Electrical › Lighting (service) › Lighting Fixture
Issued 8 October 2003 Resolved
Repair lamp in way of engine room emergency escape.
Due 1 November 2003
Resolved 7 November 2003
Resolution: Cleared by [name withheld].
Construction/Loadline › Penetrations › Weld
Issued 8 October 2003 Resolved
Provide ABS certification on repairs in way of port/stbd cargo spaces re recessed barge mooring pts. ABS to provide clarification that upon completion of repairs, vsl remains in class for hull & vsl is considered seaworthy. Repairs to be made available to attending CG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2004
Resolved 15 September 2004
Construction/Loadline
Issued 30 August 1999 Resolved
CROP AND RENEW FORWARD TRANSVERSE SWASH BULKHEAD BETWEEN #1 AND #2 HORIZONTAL STIFFINERS FROM TOP. INSERT APPROXIMATELY 18" X 6" ABOVE AND BELOW ASSOCIATED STIFFINERS IWO SIDESHELL.
Condition: Unknown
Due 30 August 1999
Resolved 30 August 1999
Construction/Loadline
Issued 30 August 1999 Resolved
REPAIR VENT PIPING FOR #3 PORT DOUBLE BOTTOM LOCATED INSIDE #3 PORT WING BALLAST TANK AT FRAME 42
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Engineering
Issued 20 August 1998 Resolved
Air receiver safety valves in engine room are so arranged that manual relief would cause a hazardous situation. Provide alternate arrangement such as a remote pull cable installation as discussed with chief engineer IAW 46 CFR 54.15-10(c) and 50.20-35.
Condition: Unknown
Due 3 September 1998
Resolved 17 September 1998
Fire Fighting
Issued 20 August 1998 Resolved
General alarm bell not audible on C-Deck port side. Repair to the satisfaction of attending marine inspector.
Condition: Unknown
Due 3 September 1998
Resolved 17 September 1998
Engineering
Issued 20 August 1998 Resolved
Controllable pitch propeller remote operating stations on bridge wings are inoperable. Repair to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 20 August 1998
Resolved 20 August 1998
Engineering
Issued 20 August 1998 Resolved
Vessel engine room automation procedures do not reflect actual engine room machinery installation. Procedures dated 20 April 81 ([name withheld]) for sister vessel Cape Texas (Ex Lyra). Procedures reviewed with C/E and lead inspector. Submit new procedures to USCG as per 46 CFR 61.40-10.
Condition: Unknown
Due 20 August 1998
Resolved 20 August 1998
Fire Fighting
Issued 20 August 1998 Resolved
Low pressure fixed CO2 system, when activated, does not automatically shutdown ventilation to engine room. Also, note the controls for these_x001C_ ventilators are not in a nearby location to pull station controls. Providearrangement for shutdown as per 46 CFR 95.15-35.
Condition: Unknown
Due 3 September 1998
Resolved 17 September 1998
Fire Fighting
Issued 20 August 1998 Resolved
Low pressure fixed CO2 system, instructions at 01 mdeck pull station and inCO2 room do not include steps to shutdown and close ventilation systems: iewatertight doors on deck as noted in 46 CFR 95.15-35. Have posted procedures corrected to include same._x001C_
Condition: Unknown
Due 3 September 1998
Resolved 17 September 1998
Fire Fighting
Issued 20 August 1998 Resolved
Provide report from servicing facility documenting low pressure CO2 alarms were tested (CO2 tank high pressure, low pressure, reefer unit failure and low CO2 level alarm).
Condition: Unknown
Due 3 September 1998
Resolved 17 September 1998
Navigation
Issued 20 August 1998 Resolved
Steering gear rudder angle indicator linkage has excessive play on connection off rudder and connection to ruder angle sender. Also existing excessive play has caused play on shaft on rudder angle sender. Repair items as original to satisfaction of CG marine inspector.
Condition: Unknown
Due 3 September 1998
Resolved 17 September 1998
Engineering
Issued 20 August 1998 Resolved
Repair starboard side main diesel engine exhaust stack insulation. Currentinstallation is a fire hazard.
Condition: Unknown
Due 3 September 1998
Resolved 17 September 1998
Navigation
Issued 20 August 1998 Resolved
Emergency steering procedures on bridge do not reflect proper procedures for bridge personnel. Suibmit amended procedures for bridge personnel. Submit amended procedures to USCG that reflect accurate procedure for ship's arrangement.
Condition: Unknown
Due 3 September 1998
Resolved 17 September 1998
Construction/Loadline
Issued 20 August 1998 Resolved
Existing emergency bilge injection valve suction strainer is improper. Strainer size should be " not less than 3 times of the suction pipe" as per46 CFR 56.50-50(g). Modify suction strainer arrangement as discussed.
Condition: Unknown
Due 20 August 1998
Resolved 20 August 1998
Lifesaving
Issued 28 August 1997 Resolved
Conduct lifeboat weight test to the stbd lifeboat.
Condition: Unknown
Due 28 August 1997
Resolved 28 August 1997
Lifesaving
Issued 21 March 1997 Resolved
REPAIR FLOATING AFT RELEASING BLOCK MECHANISM TO STARBOARD LIFEBOAT TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Lifesaving
Issued 10 December 1996 Resolved
CONDUCT LIFEBOAT WEIGHT TEST TO THE STBD LIFEBOAT.
Condition: Unknown
Due 10 December 1996
Resolved 10 December 1996
Fire Fighting
Issued 10 September 1996 Resolved
TEST/SHOW PROPER OPERATION OF LOW PRESSURE CO2 SYSTEM SHUT-DOWNS OF CARGO VENT. AND ENG.ROOM VENT. SHUT DOWNS AND ALARMS
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Unknown
Issued 10 September 1996 Resolved
SHOW PROPER OPERATION OF SHIP BOARD INCENERATOR.
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Fire Fighting
Issued 7 December 1995 Resolved
INSTALL NEW THERMAL SENSERS IN CARGO SPACES AT A HIGHER TEMP ABOVE 130 DEG.FERN.(165 OR HIGHER).
Condition: Unknown
Due 15 January 1996
Resolved 8 July 1996
Accommodation/Occupational Safety
Issued 15 November 1994 Resolved
TRANSLATE AND INSTALL ALL LABELS FROM GERMAN INTO ENGLISH.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Accommodation/Occupational Safety
Issued 15 November 1994 Resolved
INSTALL RAILING UNIT AT TOP OF STAIR TOWER ON THE BRIDGE DECK.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Navigation
Issued 15 November 1994 Resolved
PROVE CORRECT OPERATION OF THE KNOT INDICATOR ABOVE CHART TABLE.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Accommodation/Occupational Safety
Issued 15 November 1994 Resolved
EITHER PERMANENTLY DISABLE OR BRING INTO FULL COMPLIANCE THE PASSENGER ELEVATOR THAT RUNS FROM THE ENGINE CONTROL ROOM TO "E" DECK.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Construction/Loadline
Issued 15 November 1994 Resolved
REMOVE/REPLACE SUBFLOORING IN THE ENGINE CONTROL ROOM.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Electrical
Issued 15 November 1994 Resolved
RENEW/REPLACE ELECTRIC WIRES TO THE FWD LOOKING DECK LIGHTS FORM THE PORT AND STBD BRIDGE WINGS.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Electrical
Issued 15 November 1994 Resolved
INSTALL UL APPROVED MARINE FLOODLIGHTS FOR THE PORT AND STBD LIFEBOATS AT THE EMBARKATION DECK AS PER 46 CFR 111.01-9 AND 46 CFR 111.75-16.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Construction/Loadline
Issued 15 November 1994 Resolved
PROCURE/PROVIDE DOGGING WRENCH TO FIT DOGS ON DOOR TO THE EMERGENCY GENERATOR ROOM FROM "A" DECK STBD SIDE.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Construction/Loadline
Issued 15 November 1994 Resolved
PERMANENTLY MARK ALL MANHOLES WITH NAME PLATES INTO FUEL TANKS AND BALLAST TANKS.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Lifesaving
Issued 15 November 1994 Resolved
PROVIDE/INSTALL REFRIGERATED SPACE ALARM AT A MANNED LOCATION AS PER 46 CFR96.05 AND 46 CFR 113.45.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Accommodation/Occupational Safety
Issued 15 November 1994 Resolved
PROCURE/PROVIDE OPERATION AND MAINTENANCE MANUALS IN ENGLISH FOR ALL EQUIPMENT AND INSTALLED SYSTEMS.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Engineering
Issued 15 November 1994 Resolved
INSTALL PERMANENT NAME PLATES ON ALL VALVES AS PER 46 CFR 56.50.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Fire Fighting
Issued 15 November 1994 Resolved
CORRECTLY AND PERMANENTLY MARK ALL VENTS AND VENT CLOSURES.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Fire Fighting
Issued 15 November 1994 Resolved
INSTALL EITHER CUT OUT AND DRAIN VALVES OR PROTECT FROM FREEZING THE EXPOSED FIRE MAIN SYSTEM, STBD SIDE, MAIN DECK AS PER 46 CFR 95.10-10.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Fire Fighting
Issued 15 November 1994 Resolved
PROCURE/PROVIDE SUSPENDERS FOR THE TROUSERS OF THE FIREMANS OUTFITS.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Navigation
Issued 15 November 1994 Resolved
PROVIDE/PROCURE AND INSTALL SUN SCREENS/SHADES ON THE BRIDGE WINDOWS TO BE ABLE TO SEE RADAR SCREENS AT ALL TIMES OR PROCURE COWLS FOR RADAR UNITS.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Navigation
Issued 15 November 1994 Resolved
PROVIDE CURRENT UP-TO-DATE MAGNETIC COMPASS DEVIATION TABLE AS PER SOLAS 74CHAP. V REG. 12.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Deck/Cargo
Issued 15 November 1994 Resolved
FABRICATE/PROCURE AND INSTALL GUARDS ON THE DRIVE TRAIN UNITS FOR THE STERNRAMP CABLE DRUMS ON THE PORT AND STBD SIDE OF THE FANTAIL AS PER 46 CFR 92.25-15.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Fire Fighting
Issued 15 November 1994 Resolved
READJUST/RECALIBRATE FIXED FIRE DETECTION SYSTEM IN THE ACCOMODATION SPACESTO ALLOW FOR NORMAL CREW ROUTINES AS PER SOLAS 74 CHAP. II-2 REG. 13.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Navigation
Issued 15 November 1994 Resolved
PROCURE/PROVIDE DIAMOND DAY SHAPE SIGNAL DEVICE TO COMPLY WITH RULES OF THEROAD.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Lifesaving
Issued 15 November 1994 Resolved
PROCURE/PROVIDE SPAN GAS AND NITROGEN TO CALIBRATE OXYGEN/LEL METER AND DEMONSTRATE PORTABLE METERS TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Lifesaving
Issued 15 November 1994 Resolved
PROCURE/PROVIDE THE NECESSARY DRAEGER TUBES TO CONDUCT TESTING IN CARGO HOLDS, BALLAST TANKS, AND VOIDS AS PER 46 CFR 97.80.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Navigation
Issued 15 November 1994 Resolved
REPAIR AND PROVE STEERING CONTROL UNIT #2 OPERATIONAL AND RELIABLE AS PER 46 CFR 58.25-55.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Engineering
Issued 14 September 1993 Resolved
REPAIR TRIPPED EXHAUST DIFFUSER PLATE WITH BOTTOM BRACKETS, INBOARD, IN PORT WASTE HEATER.
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Construction/Loadline
Issued 14 September 1993 Resolved
CONDUCT INTERNAL EXAMINATION OF #3 STBD WING (TRIM) TANK AND #4 PORT DB TANK AFTER TANKS HAVE BEEN BLASTED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Construction/Loadline
Issued 14 September 1993 Resolved
UNCLOG LOWER PIPING ON ALL SCUPPER VALVES.
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Construction/Loadline
Issued 14 September 1993 Resolved
RENEW STBD-AFT SCUPPER VALVE LOCATED ON 2ND DECK.
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Construction/Loadline
Issued 14 September 1993 Resolved
CLEAN & REPAIR PORT SCUPPER VALVE LOCATED IN AFT MACHINE SHOP AT THE 10-2 O'CLOCK POSITION.
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Navigation
Issued 4 October 1990 Resolved
VESSEL DID NOT HAVE A TIDAL CURRENT TABLES REQUIRED BY 33 CFR 164.33(A)(3) ONBOARD.
Condition: Unknown
Due 9 October 1992
Resolved 21 October 1992
Navigation
Issued 4 October 1990 Resolved
CHARTS 12326 39TH ED, 12327 82ND ED AND 12334 58TH ED NOT CORRECTED UP TO DATE THROUGH THE LATEST NOTICE TO MARINERS AS REQUIRED BY 33 CFR 164.33(A)(1)(II)
Condition: Unknown
Due 4 February 1994
Resolved 4 February 1994
Navigation
Issued 24 March 1987 Resolved
A VIO OF 33 CFR 164.30 IN THAT THE MOST CURRENT ED OF U.S. TIDAL CURRENT TABLES OR ITS EQUIV AS REQ BY 33 CFR 164.33(A)(3)(II) WAS NOT O/B.
Condition: Unknown
Due 25 March 1987
Resolved 24 March 1987

Casualty record · 6

17 January 2013Routine · role: Involved in a Marine Casualty · activity 4517986
29 March 2013Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 injured · activity 4562652
26 June 2013Routine · role: Involved in a Marine Casualty · activity 4634413
29 September 2013Routine · role: Involved in a Marine Casualty · activity 4762941
28 October 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 6298333
14 May 2024Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7943373
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.