Inspection history · 43
21 October 2025
COI Inspection · Re-Inspection · MTSA/ISPS Verification · ACP COI Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8249589
24 June 2025
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8166404
3 June 2025
ACP Additional Oversight – Risk Assessment
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8140171
8 December 2024
MTSA/ISPS Verification · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8045017
4 December 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8043202
20 August 2024
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7999686
20 June 2024
Deficiency Check · Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7933449
3 June 2024
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7934395
17 January 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7851658
5 November 2023
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7921674
17 September 2023
Damage Survey · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7793026
16 September 2023
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7796087
22 August 2023
Annual Inspection · Administrative Inspection · ACP Annual Oversight · Deficiency Check · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7774143
6 September 2022
Deficiency Check · Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7542837
18 August 2022
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7540480
10 August 2022
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7531022
7 June 2022
In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7516008
16 May 2022
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7450144
13 October 2021
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7331984
6 October 2021
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7328292
11 June 2021
Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7185349
14 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7175112
16 July 2020
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7008045
12 June 2020
Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6975073
11 February 2020
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6907213
3 December 2019
In-Service Inspection · Administrative Inspection · ACP Additional Oversight – Risk Assessment
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6846299
3 December 2019
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6883465
31 October 2019
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6846660
25 September 2019
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6820791
9 July 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6810281
1 July 2019
MTSA/ISPS Verification · ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6723761
23 March 2019
In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6649733
13 February 2019
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6625520
8 September 2018
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6535463
21 August 2018
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6518888
12 July 2018
Periodic Inspection · MTSA/ISPS Verification · ACP Periodic Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6476805
3 November 2017
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6300340
28 October 2017
Damage Survey
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6296561
28 October 2017
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6298333
13 July 2017
Deficiency Check · ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6198023
23 December 2016
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6061849
29 March 2016
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5849846
28 March 2016
MTSA/ISPS Verification · Administrative Inspection · DAPI Audit · ACP COI Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5841759
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 October 2025
No resolution recorded
Fire extinguishing appliances in new and existing passenger ships and cargo ships shall be kept in good order and available for immediate use at all times during the voyage. Fire station #41 piping ruptured and must be repaired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 October 2025
No resolution recorded
The power available shall be sufficient to supply all those services which are necessary for the safety of all on board in an emergency…Special consideration shall be given to emergency lighting at every boat station on deck and oversides, in all alleyways, stairways and exits. Several emergency lighting fixtures were damaged throughout accommodation spaces.
SOLAS 60 II/26(a)(ii)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 October 2025
No resolution recorded
After survey of the ship under regulations 7, 8, 9, 10 has been completed, no change shall be made in the structural arrangements, machinery, equipments covered by the survey, without the sanction of the Administration. Hydraulic tank sight glass in windlass room leaking and winch for port side cargo area ramp also leaking hydraulic oil.
SOLAS(60)I/11
Action required: 16 - Rectify deficiencies w/in 14 days
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 21 October 2025
No resolution recorded
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. When in ROS status, vessel has minimum crew and maneuverability. Prior to activation, vessel must conduct fire and abandon ship drills, lower lifeboats into the water, and put all safety gear at location to the satisfaction of the attending Marine Inspector.
SOLAS 60 III/26(a)(ii)
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 December 2024
No resolution recorded
Fire protection systems shall be provided to adequately protect the ship from the fire hazards associated with vehicle, special category and ro-ro spaces and weather deck intended for the carriage of vehicles. Vessel has fixed AFFF extinguishing system on open deck. Foam is expired. Prior to carrying cargo on deck must submit a valid servicing report on system to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 20 June 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessel's life rafts were not properly connected to the hydrostatic releases and the hydrostatic releases were expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2024
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 20 June 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessel was unable to locate the lifeboat radios.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2024
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 20 June 2024
Resolved
The place or berth shall be securely constructed, properly lighted, drained, heated, and ventilated, properly protected from the weather and sea, and shall be kept free from goods or stores that are not personal property of the crew occupying the place in use during the voyage. Vessel's accommodations spaces, specifically on C Deck, had no working lighting. Cabinet doors were falling off, there was an old fridge stored in one of the rooms, and accommodations need sanitary cleaning. Vessel to clean, repair and make habitable all crew accommodations prior to activation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 June 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. No audible bilge alarms can be heard in the ECR or Engine Room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 August 2024
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 June 2024
Resolved
Fire protection systems and appliances shall be maintained ready for use and properly tested and inspected. Vessel can not conduct any functional testing of the smoke detectors because it does not have any simulated smoke on board. Vessel borrowed a can from another ship to test smoke detectors during exam but do not have any for future tests.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 August 2024
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 20 June 2024
Resolved
Structural fire protection, including fire-resisting divisions and protections of openings and penetrations in these divisions shall be kept in good order so as to ensure their required performance if a fire occurs. Vessel has an open cable penetrating through from the dry stores into the reefer compressor room. That boundary is identified as an A60 boundary.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 August 2024
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 20 June 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be working order and ready for immediate use. Prior to activation, vessel must conduct fire, abandon ship and security drills. All safety gear must also be put on location. This must be done to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 8 December 2024
Resolution: Ran satisfactory drills with required equipment on station.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 20 June 2024
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and inspections are held at appropriate intervals. Vessel is showing over 100 items overdue on maintenance. Vessel has been short staffed various crew members over the last year, including not having a Chief Mate on board during the inspection. Based on the above deficiencies and the amount of overdue maintenance items, an internal audit is to be conducted with corrective action provided to the OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 August 2024
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 6 September 2022
Resolved
In cargo ships, a muster of the crew for boat drill and fire drill shall take place at intervals of not more than one month, provided that a muster of the crew for boat drill and fire drill shall take place within 24 hours o leave in a port if more that 25% of the crew have been replaced at that port.
Due to vessel crewing fire, abandon ship and muster drills have not been conducted.
60 SOLAS Chp. III/Reg 26(a)(ii)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2023
Resolution: Witnessed satisfactory Drills. All Sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 September 2022
Resolved
All required fire detection systems shall be capable of automatically indicating the presence or indication of fire and also its location.
Vessel's fire detection panel showed the following faults:
1. Loop Analogue 7 Cable Break Positive, Fault 141
2. Zone 2 Smoke 28 Dirty Sensor Fault (130)
Vessel was able to clear the dirty sensor fault but cable break fault remains.
60 SOLAS Chp. II/Reg 61(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 October 2022
Resolution: Received documentation showing working fire alarms system.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 September 2022
Resolved
Fire extinguishers shall be periodically examined and subjected to such test as the Administration may required.
Vessel's wheeled portable fire extinguisher in cargo hold was not properly charged.
60 SOLAS Chp II/Reg 57(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 October 2022
Resolution: Received documentation showing fire extinguishers were examined/tested.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 11 June 2021
Resolved
All the life-saving appliances shall be kept in working order and available for immediate use before the ship leaves port and at all times during the voyage.
Starboard lifeboat has structural failures in the FRP that is attached to the FWD releasing gear stabilizer plates. STBD life boat inoperable.
Provide life raft on STBD side w/enough capacity for 150% of total crew currently onboard & provide crew instructions on abandon ship w/stbd life rafts.
60 SOLAS III/4(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2021
Resolution: Verified vessel had installed 3 additional life rafts totaling 60 person on STBD under lifeboat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 11 June 2021
Resolved
Davit falls, blocks and all other gear shall be of such strength that the life boat can be safely lowered w/full complement of persons & equipment.
Cracks & fractures on STBD lifeboat noted where releasing gear bolted to life boat affecting structure.
60 SOLAS III/36(f)
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2021
Resolution: Received ABS Class survey report Finding No. 1092.0 accepting CG-835V deficiency. Uploaded survey report #4689977 into documents section of the deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 July 2020
Resolved
Vessel must undergo an annual inspection within three months before or after each anniversary date. Vessel did not complete the annual inspection within the required time. Complete satisfactory annual inspection to the satisfaction of the attending marine inspector prior to departure from the port. 46 CFR 91.27-1(a)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2020
Resolved 16 September 2020
Resolution: Vessel gained credit for their COI annual following satisfactory completion of worklist items and annual class endorsements.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 3 December 2019
Resolved
Durign Testing of automation, port/stbd ships ervice generator high jacket water temperature shutdown found to be out of calibration. vessel directed to calibrate sensors for P/S SSG and prove automation shutdown to attending class surveyor.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 11 February 2020
Resolution: Recieved ABS report 4067127 dated 21 Jan 2020 attesting to rectification of defiency. Proved succesful recalibration, tested in presence of attending surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 1 July 2019
Resolved
All manned spaces must be adequately heated and cooled in a manner suitable to the purpose of the space. Fan in bow thruster room is not operational, causing room to overheat. Vessel is required to repair fan to ensure temperature is suitable temperature is maintained to allow for a comfortable work environment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 24 October 2019
Resolution: ABS found the fan in bow thruster repaired and operationally tested to the satisfaction of the attending surveyor. Report # 959
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 July 2019
Resolved
Navigation lights are to be sufficiently illuminated, in
order to allow for visibility. Several of the navigation lights on the vessel would not turn on. Vessel is required to repair navigation lights, as needed to ensure proper illumination.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 30 July 2019
Resolution: It was verified by the attending surveyor (ABS) that all navigation lights wer able to be turned on. Report # 937.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 July 2019
Resolved
Vessel is required to have adequate railings.
Several railings on B Deck and on the port side of the Cargo Deck were split and cracked. Vessel to repair areas where railings are cracked.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 4 September 2019
Resolution: Affected railings have been repaired to the satisfaction of the attending surveyor (ABS). Report # 950.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 July 2019
Resolved
Vessel is required to have a working EPIRB with hydrostatic release. Vessel's EPIRB was not operational and hydrostatic release was expired. Vessel to repair or replace EPIRB and replace hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2019
Resolved 30 July 2019
Resolution: It was verified by the attending surveyor (ABS) that a new EPRIB and hydrostatic release have been placed onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 1 July 2019
Resolved
Vessel found to have non-slip matting pads in the steering gear flat to be oil soaked; rendering them slippery and a hazards. Vessel is directed to replace the non-slip material to render it ready for use.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 30 July 2019
Resolution: It was verified by the attending surveyor (ABS) that the mats were removed and the grates underneath were cleaned to the satisfaction of surveyor. Report #940.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 July 2019
Resolved
Vessel's emergency lighting in the emergency generator room and emergency switchboard room found to be inoperable upon loss of ships power. Vessel is directed to repair emergency lighting in listed spaces.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 30 July 2019
Resolution: The batteries in the emergency lights in the emerg. generator room and emerg. switchboard room were replaced and lights operationally tested to the satisfaction of attending surveyor. Report # 941.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2019
Resolved
Vessel found to have two open holes from missing switches in front panel of emergency switchboard. Vessel is directed to plug the cutouts to render them properly guarded.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 30 July 2019
Resolution: It was verified that the two open holes had been plugged to the satisfaction of the attending surveyor (ABS). Report # 942.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 1 July 2019
Resolved
Vessel's periodic safety test procedures were found to be missing multiple step by step procedures for the ship service generating sets, main engine, emergency generator. Vessel directed to create step-by-step checklist procedure for testing of applicable tests including but not limited to overspeed, low oil pressure, high jacket water temperature testing for each vital system automation as required by 46 CFR 61.40-10, 46 CFR 62.35-50 (table).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 7 October 2019
Resolution: The Chief Engineer has been progressively updating PTSP. Report # 960
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 July 2019
Resolved
Vessel found to have coolant water leak on #3 port main diesel engine cylinder head. Vessel directed to make repairs to head to contain the coolant water and prevent further corrosion of cylinder.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 30 July 2019
Resolution: The area surrounding the leak was thoroughly cleaned and the main engine was then operationally tested to the satisfaction of the attending surveyor (ABS). No leaks found. Report # 944
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 July 2019
Resolved
Vessel unable to demonstrate proper reverse power relay of starboard generator. Motorization of the starboard generator did not trip the generator off-line from the load.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 30 July 2019
Resolution: The reverse power relay to the starboard generator was replaced and then operationally tested to the satisfaction of the attending surveyor (ABS). Report # 945.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 July 2019
Resolved
Lifelines on lifebuoys must be dark in color or certified as UV resistant by manufacturer. Several lifelines on lifebuoys were yellow/orange and there was no UV resistant certification. Vessel to replace.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 4 September 2019
Resolution: Affected lifelines were replaced with black life lines per 60 SOLAS 1/11 and 46 CFR 199.70.3. Report # 952.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 July 2019
Resolved
Vessel is required to have materials onboard
the vessel pertaining to firefighting duties and use of equipment. Vessel did not have a firefighting training manual onboard. Vessel to create and implement a firefighting training manual.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 30 July 2019
Resolution: It was verified that the vessel had developed a dhip-specific firefighting training manual to the satisfaction of the attending surveyor (ABS). Report # 947.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 1 July 2019
Resolved
Exposed openings in vessel must be able to close to ensure vessel can be made watertight. BOSN Store vent hatch does not close. Vessel to repair hatch.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 30 July 2019
Resolution: The gasket to the BOSN store vent hatch was replaced and was then able to close fully to the satisfaction of the attending surveyor (ABS). Report # 948.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2018
Resolved
Port Generator parallel switch would not engage breaker to parallel.
SOLAS 2014 II-1 40.1.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2018
Resolved 7 August 2018
Resolution: Vessel replaced port generator parallel switch and tested for ABS surveyor. Test sat.
Construction/Loadline › Hull › Side Shell
Issued 28 October 2017
Resolved
Side shell damage on Port side A strake as result of damage from CAPE TRINITY allsion while mooring.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 October 2017
Resolved 13 February 2019
Resolution: USCG accepted ABS re-attendance of vessel for corrective action. Damaged shell plating and deck plating cropped and renewed back original, including internals in way of damaged deck and shell plating. Satisfactory water hose test.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 13 July 2017
Resolved
Expired COD
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 August 2017
Resolved 1 August 2017
Resolution: Vessel produced valid COD.
Navigation › Collision/Grounding Avoidance › Radar
Issued 13 July 2017
Resolved
Vessel unable to operate installed radars.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 August 2017
Resolved 1 August 2017
Resolution: Witnessed proper operation of radars.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 July 2017
Resolved
ABS noted deficiencies in missing handrails and wastage on deck plating. ABS report attached.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 20 September 2017
Resolution: Reviewed class report. All sat.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 13 July 2017
Resolved
ABS noted wasted metal on various bulheads in f/o tanks adjacent to cargo hold. ABS survey attached.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 20 September 2017
Resolution: Reviewed class report all sat.