Records from 1985 to 2025. Most recent: inspection, 21 October 2025.
Inspection history · 149
21 October 2025
COI Inspection · Re-Inspection · MTSA/ISPS Verification · ACP COI Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8249589
24 June 2025
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8166404
3 June 2025
ACP Additional Oversight – Risk Assessment
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8140171
8 December 2024
MTSA/ISPS Verification · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8045017
4 December 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8043202
20 August 2024
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7999686
20 June 2024
Deficiency Check · Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7933449
3 June 2024
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7934395
17 January 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7851658
5 November 2023
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7921674
17 September 2023
Damage Survey · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7793026
16 September 2023
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7796087
22 August 2023
Annual Inspection · Administrative Inspection · ACP Annual Oversight · Deficiency Check · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7774143
6 September 2022
Deficiency Check · Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7542837
18 August 2022
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7540480
10 August 2022
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7531022
7 June 2022
In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7516008
16 May 2022
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7450144
13 October 2021
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7331984
6 October 2021
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7328292
11 June 2021
Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7185349
14 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7175112
16 July 2020
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7008045
12 June 2020
Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6975073
11 February 2020
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6907213
3 December 2019
In-Service Inspection · Administrative Inspection · ACP Additional Oversight – Risk Assessment
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6846299
3 December 2019
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6883465
31 October 2019
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6846660
25 September 2019
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6820791
9 July 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6810281
1 July 2019
MTSA/ISPS Verification · ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6723761
23 March 2019
In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6649733
13 February 2019
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6625520
8 September 2018
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6535463
21 August 2018
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6518888
12 July 2018
Periodic Inspection · MTSA/ISPS Verification · ACP Periodic Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6476805
3 November 2017
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6300340
28 October 2017
Damage Survey
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6296561
28 October 2017
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6298333
13 July 2017
Deficiency Check · ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6198023
23 December 2016
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6061849
29 March 2016
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5849846
28 March 2016
MTSA/ISPS Verification · Administrative Inspection · DAPI Audit · ACP COI Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5841759
10 December 2015
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5778235
5 January 2011
Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 3921470
13 October 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3869413
21 May 2008
ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3212533
27 June 2007
ACP Annual Oversight
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2975788
20 October 2006
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2806644
13 September 2006
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2777327
15 August 2006
ACP COI Oversight
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2748848
9 May 2006
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2602260
24 March 2006
MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2608752
7 March 2006
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2597677
4 November 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2528366
26 October 2005
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2522661
15 September 2005
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2493084
10 August 2005
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2466952
27 December 2004
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2265321
26 December 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2264747
22 December 2004
MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2263719
26 July 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2145436
20 July 2004
Periodic Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2163317
3 June 2004
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 2087518
28 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1995724
6 October 2003
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1923707
25 January 2003
Administrative Inspection · Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1735366
23 December 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1728186
30 May 2002
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1623712
20 June 2001
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1068633
31 May 2001
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1389394
8 January 2001
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 825321
8 February 2000
COI Inspection · Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1378950
8 February 1999
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1400927
5 November 1998
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 808923
13 September 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 403
10 September 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 804613
29 July 1998
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1131849
28 May 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1464103
10 February 1998
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1428905
24 March 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 182356
21 March 1997
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1104270
7 February 1997
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1406050
16 July 1996
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1092257
11 July 1996
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 837039
9 July 1996
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1092254
3 June 1996
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1092212
26 April 1996
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1427214
15 February 1996
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1438403
14 November 1995
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 882075
23 August 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 880172
23 June 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1383046
7 February 1995
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1383047
30 September 1994
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 165531
16 September 1994
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 460998
22 April 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 858540
1 March 1994
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1166854
23 February 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 88183
15 February 1994
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 853752
31 December 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 144954
3 February 1993
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1472395
26 January 1993
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 177891
20 January 1993
COI Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 828429
7 December 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 489218
17 November 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1136819
9 November 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 170474
3 November 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 661466
27 October 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249889
26 October 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 4614
14 August 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 353070
22 May 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 52314
22 May 1992
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1269263
20 May 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 165956
13 May 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 180653
26 March 1992
Examination of Repairs
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 961446
19 August 1991
Hull Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1246805
15 June 1991
Drydock Extension · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1194756
24 August 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 901654
24 August 1990
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 902758
16 August 1990
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 926116
6 July 1990
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 989173
20 January 1990
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 930095
19 January 1990
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1238682
15 December 1989
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1243434
12 November 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 914753
18 October 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1349551
13 June 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1199066
26 February 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1349978
19 December 1988
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1340374
2 December 1988
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1207946
28 September 1988
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 891931
24 September 1988
Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1045281
19 August 1988
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1037519
22 June 1988
Hull Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1339532
14 September 1987
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1004766
29 June 1987
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 509039
24 June 1987
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 522215
13 May 1987
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1005948
13 May 1987
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1024326
13 April 1987
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1310617
16 October 1986
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1009324
14 October 1986
Examination of Repairs · Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1317285
20 July 1986
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 520666
23 March 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 999203
20 February 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 991563
20 December 1985
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 463026
12 November 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 990178
16 June 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1288995
24 February 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1286338
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 October 2025
No resolution recorded
Fire extinguishing appliances in new and existing passenger ships and cargo ships shall be kept in good order and available for immediate use at all times during the voyage. Fire station #41 piping ruptured and must be repaired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 October 2025
No resolution recorded
The power available shall be sufficient to supply all those services which are necessary for the safety of all on board in an emergency…Special consideration shall be given to emergency lighting at every boat station on deck and oversides, in all alleyways, stairways and exits. Several emergency lighting fixtures were damaged throughout accommodation spaces.
SOLAS 60 II/26(a)(ii)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 October 2025
No resolution recorded
After survey of the ship under regulations 7, 8, 9, 10 has been completed, no change shall be made in the structural arrangements, machinery, equipments covered by the survey, without the sanction of the Administration. Hydraulic tank sight glass in windlass room leaking and winch for port side cargo area ramp also leaking hydraulic oil.
SOLAS(60)I/11
Action required: 16 - Rectify deficiencies w/in 14 days
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 21 October 2025
No resolution recorded
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. When in ROS status, vessel has minimum crew and maneuverability. Prior to activation, vessel must conduct fire and abandon ship drills, lower lifeboats into the water, and put all safety gear at location to the satisfaction of the attending Marine Inspector.
SOLAS 60 III/26(a)(ii)
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 December 2024
No resolution recorded
Fire protection systems shall be provided to adequately protect the ship from the fire hazards associated with vehicle, special category and ro-ro spaces and weather deck intended for the carriage of vehicles. Vessel has fixed AFFF extinguishing system on open deck. Foam is expired. Prior to carrying cargo on deck must submit a valid servicing report on system to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 20 June 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessel's life rafts were not properly connected to the hydrostatic releases and the hydrostatic releases were expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2024
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 20 June 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessel was unable to locate the lifeboat radios.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2024
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 20 June 2024
Resolved
The place or berth shall be securely constructed, properly lighted, drained, heated, and ventilated, properly protected from the weather and sea, and shall be kept free from goods or stores that are not personal property of the crew occupying the place in use during the voyage. Vessel's accommodations spaces, specifically on C Deck, had no working lighting. Cabinet doors were falling off, there was an old fridge stored in one of the rooms, and accommodations need sanitary cleaning. Vessel to clean, repair and make habitable all crew accommodations prior to activation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 June 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. No audible bilge alarms can be heard in the ECR or Engine Room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 August 2024
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 June 2024
Resolved
Fire protection systems and appliances shall be maintained ready for use and properly tested and inspected. Vessel can not conduct any functional testing of the smoke detectors because it does not have any simulated smoke on board. Vessel borrowed a can from another ship to test smoke detectors during exam but do not have any for future tests.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 August 2024
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 20 June 2024
Resolved
Structural fire protection, including fire-resisting divisions and protections of openings and penetrations in these divisions shall be kept in good order so as to ensure their required performance if a fire occurs. Vessel has an open cable penetrating through from the dry stores into the reefer compressor room. That boundary is identified as an A60 boundary.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 August 2024
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 20 June 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be working order and ready for immediate use. Prior to activation, vessel must conduct fire, abandon ship and security drills. All safety gear must also be put on location. This must be done to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 8 December 2024
Resolution: Ran satisfactory drills with required equipment on station.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 20 June 2024
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and inspections are held at appropriate intervals. Vessel is showing over 100 items overdue on maintenance. Vessel has been short staffed various crew members over the last year, including not having a Chief Mate on board during the inspection. Based on the above deficiencies and the amount of overdue maintenance items, an internal audit is to be conducted with corrective action provided to the OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 August 2024
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 6 September 2022
Resolved
In cargo ships, a muster of the crew for boat drill and fire drill shall take place at intervals of not more than one month, provided that a muster of the crew for boat drill and fire drill shall take place within 24 hours o leave in a port if more that 25% of the crew have been replaced at that port.
Due to vessel crewing fire, abandon ship and muster drills have not been conducted.
60 SOLAS Chp. III/Reg 26(a)(ii)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2023
Resolution: Witnessed satisfactory Drills. All Sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 September 2022
Resolved
All required fire detection systems shall be capable of automatically indicating the presence or indication of fire and also its location.
Vessel's fire detection panel showed the following faults:
1. Loop Analogue 7 Cable Break Positive, Fault 141
2. Zone 2 Smoke 28 Dirty Sensor Fault (130)
Vessel was able to clear the dirty sensor fault but cable break fault remains.
60 SOLAS Chp. II/Reg 61(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 October 2022
Resolution: Received documentation showing working fire alarms system.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 September 2022
Resolved
Fire extinguishers shall be periodically examined and subjected to such test as the Administration may required.
Vessel's wheeled portable fire extinguisher in cargo hold was not properly charged.
60 SOLAS Chp II/Reg 57(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 October 2022
Resolution: Received documentation showing fire extinguishers were examined/tested.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 11 June 2021
Resolved
All the life-saving appliances shall be kept in working order and available for immediate use before the ship leaves port and at all times during the voyage.
Starboard lifeboat has structural failures in the FRP that is attached to the FWD releasing gear stabilizer plates. STBD life boat inoperable.
Provide life raft on STBD side w/enough capacity for 150% of total crew currently onboard & provide crew instructions on abandon ship w/stbd life rafts.
60 SOLAS III/4(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2021
Resolution: Verified vessel had installed 3 additional life rafts totaling 60 person on STBD under lifeboat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 11 June 2021
Resolved
Davit falls, blocks and all other gear shall be of such strength that the life boat can be safely lowered w/full complement of persons & equipment.
Cracks & fractures on STBD lifeboat noted where releasing gear bolted to life boat affecting structure.
60 SOLAS III/36(f)
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2021
Resolution: Received ABS Class survey report Finding No. 1092.0 accepting CG-835V deficiency. Uploaded survey report #4689977 into documents section of the deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 July 2020
Resolved
Vessel must undergo an annual inspection within three months before or after each anniversary date. Vessel did not complete the annual inspection within the required time. Complete satisfactory annual inspection to the satisfaction of the attending marine inspector prior to departure from the port. 46 CFR 91.27-1(a)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2020
Resolved 16 September 2020
Resolution: Vessel gained credit for their COI annual following satisfactory completion of worklist items and annual class endorsements.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 3 December 2019
Resolved
Durign Testing of automation, port/stbd ships ervice generator high jacket water temperature shutdown found to be out of calibration. vessel directed to calibrate sensors for P/S SSG and prove automation shutdown to attending class surveyor.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 11 February 2020
Resolution: Recieved ABS report 4067127 dated 21 Jan 2020 attesting to rectification of defiency. Proved succesful recalibration, tested in presence of attending surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 1 July 2019
Resolved
All manned spaces must be adequately heated and cooled in a manner suitable to the purpose of the space. Fan in bow thruster room is not operational, causing room to overheat. Vessel is required to repair fan to ensure temperature is suitable temperature is maintained to allow for a comfortable work environment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 24 October 2019
Resolution: ABS found the fan in bow thruster repaired and operationally tested to the satisfaction of the attending surveyor. Report # 959
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 July 2019
Resolved
Navigation lights are to be sufficiently illuminated, in
order to allow for visibility. Several of the navigation lights on the vessel would not turn on. Vessel is required to repair navigation lights, as needed to ensure proper illumination.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 30 July 2019
Resolution: It was verified by the attending surveyor (ABS) that all navigation lights wer able to be turned on. Report # 937.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 July 2019
Resolved
Vessel is required to have adequate railings.
Several railings on B Deck and on the port side of the Cargo Deck were split and cracked. Vessel to repair areas where railings are cracked.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 4 September 2019
Resolution: Affected railings have been repaired to the satisfaction of the attending surveyor (ABS). Report # 950.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 July 2019
Resolved
Vessel is required to have a working EPIRB with hydrostatic release. Vessel's EPIRB was not operational and hydrostatic release was expired. Vessel to repair or replace EPIRB and replace hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2019
Resolved 30 July 2019
Resolution: It was verified by the attending surveyor (ABS) that a new EPRIB and hydrostatic release have been placed onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 1 July 2019
Resolved
Vessel found to have non-slip matting pads in the steering gear flat to be oil soaked; rendering them slippery and a hazards. Vessel is directed to replace the non-slip material to render it ready for use.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 30 July 2019
Resolution: It was verified by the attending surveyor (ABS) that the mats were removed and the grates underneath were cleaned to the satisfaction of surveyor. Report #940.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 July 2019
Resolved
Vessel's emergency lighting in the emergency generator room and emergency switchboard room found to be inoperable upon loss of ships power. Vessel is directed to repair emergency lighting in listed spaces.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 30 July 2019
Resolution: The batteries in the emergency lights in the emerg. generator room and emerg. switchboard room were replaced and lights operationally tested to the satisfaction of attending surveyor. Report # 941.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2019
Resolved
Vessel found to have two open holes from missing switches in front panel of emergency switchboard. Vessel is directed to plug the cutouts to render them properly guarded.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 30 July 2019
Resolution: It was verified that the two open holes had been plugged to the satisfaction of the attending surveyor (ABS). Report # 942.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 1 July 2019
Resolved
Vessel's periodic safety test procedures were found to be missing multiple step by step procedures for the ship service generating sets, main engine, emergency generator. Vessel directed to create step-by-step checklist procedure for testing of applicable tests including but not limited to overspeed, low oil pressure, high jacket water temperature testing for each vital system automation as required by 46 CFR 61.40-10, 46 CFR 62.35-50 (table).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 7 October 2019
Resolution: The Chief Engineer has been progressively updating PTSP. Report # 960
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 July 2019
Resolved
Vessel found to have coolant water leak on #3 port main diesel engine cylinder head. Vessel directed to make repairs to head to contain the coolant water and prevent further corrosion of cylinder.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 30 July 2019
Resolution: The area surrounding the leak was thoroughly cleaned and the main engine was then operationally tested to the satisfaction of the attending surveyor (ABS). No leaks found. Report # 944
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 July 2019
Resolved
Vessel unable to demonstrate proper reverse power relay of starboard generator. Motorization of the starboard generator did not trip the generator off-line from the load.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 30 July 2019
Resolution: The reverse power relay to the starboard generator was replaced and then operationally tested to the satisfaction of the attending surveyor (ABS). Report # 945.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 July 2019
Resolved
Lifelines on lifebuoys must be dark in color or certified as UV resistant by manufacturer. Several lifelines on lifebuoys were yellow/orange and there was no UV resistant certification. Vessel to replace.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 4 September 2019
Resolution: Affected lifelines were replaced with black life lines per 60 SOLAS 1/11 and 46 CFR 199.70.3. Report # 952.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 July 2019
Resolved
Vessel is required to have materials onboard
the vessel pertaining to firefighting duties and use of equipment. Vessel did not have a firefighting training manual onboard. Vessel to create and implement a firefighting training manual.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 30 July 2019
Resolution: It was verified that the vessel had developed a dhip-specific firefighting training manual to the satisfaction of the attending surveyor (ABS). Report # 947.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 1 July 2019
Resolved
Exposed openings in vessel must be able to close to ensure vessel can be made watertight. BOSN Store vent hatch does not close. Vessel to repair hatch.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 30 July 2019
Resolution: The gasket to the BOSN store vent hatch was replaced and was then able to close fully to the satisfaction of the attending surveyor (ABS). Report # 948.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2018
Resolved
Port Generator parallel switch would not engage breaker to parallel.
SOLAS 2014 II-1 40.1.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2018
Resolved 7 August 2018
Resolution: Vessel replaced port generator parallel switch and tested for ABS surveyor. Test sat.
Construction/Loadline › Hull › Side Shell
Issued 28 October 2017
Resolved
Side shell damage on Port side A strake as result of damage from CAPE TRINITY allsion while mooring.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 October 2017
Resolved 13 February 2019
Resolution: USCG accepted ABS re-attendance of vessel for corrective action. Damaged shell plating and deck plating cropped and renewed back original, including internals in way of damaged deck and shell plating. Satisfactory water hose test.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 13 July 2017
Resolved
Expired COD
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 August 2017
Resolved 1 August 2017
Resolution: Vessel produced valid COD.
Navigation › Collision/Grounding Avoidance › Radar
Issued 13 July 2017
Resolved
Vessel unable to operate installed radars.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 August 2017
Resolved 1 August 2017
Resolution: Witnessed proper operation of radars.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 July 2017
Resolved
ABS noted deficiencies in missing handrails and wastage on deck plating. ABS report attached.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 20 September 2017
Resolution: Reviewed class report. All sat.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 13 July 2017
Resolved
ABS noted wasted metal on various bulheads in f/o tanks adjacent to cargo hold. ABS survey attached.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 20 September 2017
Resolution: Reviewed class report all sat.
Lifesaving › Launching Appliances › Winch Brake
Issued 20 October 2006
Resolved
The vessel's port and starboard lifeboats' gravity brakes are not operating correctly.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2006
Resolved 5 December 2006
Resolution: Cleared per class (ABS) report.
Operations/Management › Drills/Instruction › Fire
Issued 24 March 2006
Resolved
Perform fire and abandon ship drills to the satisfaction of a Marine Inspector prior to sailing.
Action required: 705 - Other - as specified
Due 1 April 2006
Resolved 5 May 2006
Resolution: Drills were performed to the satisfaction of the vessel master as per the new MOU, cleared deficiency.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 10 August 2005
Resolved
Port CO2 (low pressure) tank has a leak in the top, as crew pointed out. The tank has been displaying lower pressures than required. Repair leak in port CO2 tank and refill to proper level.
Action required: 705 - Other - as specified
Due 10 September 2005
Resolved 26 October 2005
Resolution: Resolved via service technician''s report.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 10 August 2005
Resolved
Echo depth sounder not recording. Prove proper operation of the Echo depth sounder.
Action required: 705 - Other - as specified
Due 12 September 2005
Resolved 7 March 2006
Resolution: Cleared per Master''s statement (who is now Chief Mate while ship is in inactive status.
Lifesaving › Lifeboat
Issued 6 October 2003
Resolved
Repair the following deficiency to starboard life boat, crack in gunwhale, sponge fiberglass on aft bench stbd side, blister stbd side aft and properly reattach upper portion of buoyancy compartment port side of boat. Renew retro tape on upper portion of boat. LEGACY COMPONENT DESC: Hull
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 20 November 2003
Resolved 29 January 2004
Resolution: CG inspected. All sat.
Engineering › Compressed Air System (control)
Issued 6 October 2003
Resolved
Provide bench test results for the ship's service air receiver relief valve and in-line relief valve. LEGACY COMPONENT DESC: Receiver/Bottle
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 9 October 2003
Resolution: Replaced relief valve with new .
Fire Fighting › Combustible Materials
Issued 6 October 2003
Resolved
Update and post fire control plan.
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 29 January 2004
Resolution: CG inspected. All sat.
Navigation › Piloting/Steering › Marine Charts
Issued 6 October 2003
Resolved
Correct all required charts to most recent notice to mariners publication.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2004
Lifesaving › Buoyant Smoke Signals
Issued 6 October 2003
Resolved
Install proper ring buoy with smoke signal on the port side bridge wing with a quick release station.
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 29 January 2004
Resolution: CG inspected. All sat.
Fire Fighting › Miscellaneous Items
Issued 6 October 2003
Resolved
Repair dryer vent on commercial dryer.
Action required: 705 - Other - as specified
Resolved 10 December 2015
Resolution: vent repaired
Pollution Prevention/Response › Prevention Equipment
Issued 6 October 2003
Resolved
Make Oily water separator and Bow thruster space available for inspection. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 6 November 2003
Resolved 9 November 2003
Resolution: OWS tested and in good operating condition. Marine chemist certified bow thruster room safe for entry, space was inspected satisfactorily.
Deck/Cargo
Issued 31 May 2001
Resolved
PRIOR TO THE CARRIAGE OF VEHICLES, PROVE PROPER OPERATION OF "LOSS OF REQUIRED VENTILATION ALARMS" FOR SPACES "SPECIALLY SUITABLE FOR VEHICLES" IAW 46 CFR 92.15-10(D)(4).
Condition: Unknown
Due 31 May 2001
Resolved 31 May 2001
Engineering
Issued 31 May 2001
Resolved
RE-SUBMIT AUTOMATION TEST PROCEDURES RELECTING CURRENT CHANGES TO MARINE SAFETY CENTER FOR APPROVAL.
Condition: Unknown
Due 30 June 2001
Resolved 9 January 2003
Resolution: repaired
Accommodation/Occupational Safety
Issued 31 May 2001
Resolved
PROVIDE PERMINENT RAIL IWO TEMP. RAIL ON B DECK, CENTERLINE LADDER AFT OF HOUSE.
Condition: Unknown
Due 31 May 2001
Resolved 31 May 2001
Construction/Loadline
Issued 31 May 2001
Resolved
PROVIDE TEMP REPAIRS TO DAMAGED BOTTOM GASKETS IWO SIDE PORT DOORS, O2 DECKPRIOR TO DEPARTURE. PROVED PERMINENT REPAIRS IWO OF THE SAME.
Condition: Unknown
Due 31 May 2001
Resolved 31 May 2001
Engineering
Issued 31 May 2001
Resolved
PROVE PROPER OPERATION OF FUEL SERVICE PUMPS AUTOMATIC CONTROL.
Condition: Unknown
Due 31 May 2001
Resolved 31 May 2001
Fire Fighting
Issued 8 February 2000
Resolved
Conduct annual servicing on all portable fire extinguishers, the fixed highpressure CO2 systems, and all firefighting emergency breathing air apparatus for the fire suits.
Condition: Unknown
Due 25 February 2000
Resolved 20 March 2000
Electrical
Issued 8 February 2000
Resolved
Replace or provide numerous covers/difusers on light fixtrures throughout vessel in accordance with 46 CFR 111.75-20.
Condition: Unknown
Due 9 March 2000
Resolved 20 March 2000
Lifesaving
Issued 8 February 2000
Resolved
Provide a general alarm bell in the lazarette in accordance with 46 CFR 113.25
Condition: Unknown
Due 9 March 2000
Resolved 20 March 2000
Fire Fighting
Issued 8 February 2000
Resolved
Verify proper operation of smoke detectors in zone 7 on second cargo deck in accordance with 46 CFR 95.05-1 and 76.33-20
Condition: Unknown
Due 9 March 2000
Resolved 20 March 2000
Lifesaving
Issued 8 February 2000
Resolved
Conduct weight test on both starboard and port lifeboats and test releasinggear while under load in accordance with 46 CFR 160.033
Condition: Unknown
Due 25 February 2000
Resolved 20 March 2000
Fire Fighting
Issued 8 February 2000
Resolved
Replace "Y" gate on the #33 fire station in accordance with 46 CFR 95.10-10
Condition: Unknown
Due 9 March 2000
Resolved 20 March 2000
Fire Fighting
Issued 8 February 2000
Resolved
Repair or replace the leaking bonnet gaskets on the valves at fire stations#3,6,7 and 8 in accordance with 46 CFR 95.10-10
Condition: Unknown
Due 9 March 2000
Resolved 20 March 2000
Engineering
Issued 8 February 1999
Resolved
Provide updated and approved engine room automation procedures in accordance with 46CFR62.20-1 prior to 08FEB2000.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Lifesaving
Issued 10 February 1998
Resolved
Conduct load test of starboard lifeboat/launching appliances (46CFR199.45(b)(1)).
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Unknown
Issued 10 February 1998
Resolved
DEMONSTRATE PROPER OPERATION OF INSTALLED SHIPBOARD INCINERATOR INCLUDING ALL SAFETY DEVICES TO THE SATISFACTION OF AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 10 February 1998
Resolved 10 February 1998
Unknown
Issued 7 February 1997
Resolved
PERFORM FIRE AND BOAT DRILLS PRIOR ACTIVATION IN THE PRESENCE OF THE COGNIGANT OFFICER IN CHARGE MARINE INSPECTION..
Condition: Unknown
Due 21 March 1997
Resolved 10 April 1997
Unknown
Issued 7 February 1997
Resolved
DEMONSTRATE PROPER OPERATION SHIP BOARD INCINERATOR INCLUDING ALL SAFETY DEVICES TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR._x001C_
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Engineering
Issued 7 February 1997
Resolved
DEMONSTRATE PROPER OPERATION OF THE PORT/STBD BRIDGE WING CPP CONTROLS TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR._x001C_
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Engineering
Issued 7 February 1997
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF THE ENGINE ORDER TELEGRAPH . WRONG DIRECTION ALARM TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR. _x001C_ 46 cfr 113.35-5 (c)
Condition: Unknown
Due 21 March 1997
Resolved 10 April 1997
Navigation
Issued 7 February 1997
Resolved
REPAIR AND DEMONSTRATE PROPER OPERTIONAL OF STEERING RUDDER ANGLE INDICTOR PORT/STBD/CENTER CONTROLS TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR_x001C_ SOLAS AMEND. 74 II-1, REG. 29, 11.
Condition: Unknown
Due 21 March 1997
Resolved 10 April 1997
Construction/Loadline
Issued 26 April 1996
Resolved
HOSE TEST PORT & STBD SIDE PORTS AND PILOT DOORS IN THE PRESENCE OF ABS SURVEYOR AND SUBMIT RESULTS TO LOCAL OCMI.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Construction/Loadline
Issued 26 April 1996
Resolved
MAKE PROPER PERMANENT REPAIRS TO DAMAGED OR WASTED INTERNAL STRUCTURAL MEMBERS IN 2 P/S AND 3 P/S WING BALLAST TANKS AS PER DOT MARAD DELIVERY ORDER DTD 4/3/96. REPAIRS ARE TO BE INSPECTED BY CG MARINE INSPECTORS.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Construction/Loadline
Issued 26 April 1996
Resolved
HOSE TEST RAMP DOOR IN THE PRESENCE OF ABS SURVEYOR IN MOBILE, AL AND SUBMIT RESULTS TO LOCAL OCMI.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Construction/Loadline
Issued 26 April 1996
Resolved
MAKE PROPER PERMANENT REPAIRS TO DAMAGED OR WASTED INTERNAL STRUCTURAL MEMBERS (TABLE PLATES) IN FOREPEAK TANK, AREAS IN VICINITY OF FRAMES 210- 217, AS INDENTIFIED IN CAPE TEXAS BASELINE BALLAST TANK SURVEY REPORT. REPAIRS ARE TO BE TO SATISFACTION OF CG MARINE INSPECTORS.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Lifesaving
Issued 15 February 1996
Resolved
RENEW EXPIRED MEDICATIONS.
Condition: Unknown
Due 15 February 1996
Resolved 15 February 1996
Documentation
Issued 15 February 1996
Resolved
RENEW FCC RADIO TELEGRAPH CERTIFICATE.
Condition: Unknown
Due 15 February 1996
Resolved 15 February 1996
Lifesaving
Issued 15 February 1996
Resolved
CONDUCT FIRE/BOAT DRILLS.
Condition: Unknown
Due 15 February 1996
Resolved 15 February 1996
Unknown
Issued 15 February 1996
Resolved
REMOVE PAINT AND TAPE FROM SIGNS THROUGHOUT WEATHER DECK.
Condition: Unknown
Due 15 February 1996
Resolved 15 February 1996
Deck/Cargo
Issued 15 February 1996
Resolved
ENSURE FORKLIFTS COMPLY WITH 46 CFR 97.
Condition: Unknown
Due 15 February 1996
Resolved 15 February 1996
Fire Fighting
Issued 15 February 1996
Resolved
INSTALL FIRESTOPS FOR SHORE TIE CABLE INTO SHIP TO SWITCHBOARDS ON A, 1, 2,AND 3 DECKS.
Condition: Unknown
Due 15 February 1996
Resolved 15 February 1996
Construction/Loadline
Issued 15 February 1996
Resolved
RENEW GASKET ON EMERGENCY GENERATOR ROOM DOOR.
Condition: Unknown
Due 15 February 1996
Resolved 15 February 1996
Documentation
Issued 15 February 1996
Resolved
RENEW FCC RADIO TELEPHONE CERTIFICATE.
Condition: Unknown
Due 15 February 1996
Resolved 15 February 1996
Lifesaving
Issued 7 February 1995
Resolved
REPLACE ALL PFDS WITH CG/SOLAS APPROVED
Condition: Unknown
Due 7 February 1996
Resolved 25 August 1995
Fire Fighting
Issued 7 February 1995
Resolved
TEST FIRE/SMOKE DETECTION SYSTEM
Condition: Unknown
Due 7 February 1996
Resolved 25 August 1995
Fire Fighting
Issued 7 February 1995
Resolved
PAINT ALL FIRE STATIONS RED
Condition: Unknown
Due 7 February 1996
Resolved 25 August 1995
Navigation
Issued 7 February 1995
Resolved
CLEAN PORT SIDELIGHT
Condition: Unknown
Due 7 February 1996
Resolved 25 August 1995
Electrical
Issued 7 February 1995
Resolved
REPLACE MISSING ELECTRICAL MATTING AT CONTROLLERS AND SWITCHBOARDS THROUGHOUT VESSEL
Condition: Unknown
Due 7 February 1996
Resolved 25 August 1995
Lifesaving
Issued 7 February 1995
Resolved
RELOCATE CO2 WARNING SIGNS TO PROPER LOCATION AT OR NEAR ALARM.
Condition: Unknown
Due 7 February 1996
Resolved 25 August 1995
Lifesaving
Issued 7 February 1995
Resolved
PROVIDE AND INSTALL ADDITIONAL GENERAL ALARMS IN CARGO HOLDS/VEHICLE DECKS
Condition: Unknown
Due 7 February 1995
Resolved 25 August 1995
Lifesaving
Issued 7 February 1995
Resolved
RELOCATE PORT/STBD LIFE RAFTS TO A LOWER DECK TO MEET THE 18 METER HEIGHT REQUIREMENT AND STENCIL STATION NUMBER AND CAPACITY.
Condition: Unknown
Due 7 February 1996
Resolved 25 August 1995
Lifesaving
Issued 7 February 1995
Resolved
REPLACE QUICK ACTING BRIDGE WING LIFE BUOY WITH PROPER WEIGHT LIFE BUOY.
Condition: Unknown
Due 7 February 1996
Resolved 25 August 1995
Electrical
Issued 7 February 1995
Resolved
RELAMP EMERGENCY LIGHTS AS NEEDED.
Condition: Unknown
Due 7 February 1996
Resolved 25 August 1995
Documentation
Issued 7 February 1995
Resolved
INSTALL FIRE CONTROL PLAN IN TUBE AT PORT AND STBD GANGWAY AND LABEL TUBE.
Condition: Unknown
Due 7 February 1996
Resolved 25 August 1995
Navigation
Issued 7 February 1995
Resolved
TEST FOR PROPER OPERATION OF NAVIGATION LIGHT PANEL ON BRIDGE
Condition: Unknown
Due 7 February 1996
Resolved 25 August 1995
Lifesaving
Issued 7 February 1995
Resolved
REPLACE ALL RING LIFE BOUYS WITH CG/SOLAS APPROVED MODEL
Condition: Unknown
Due 7 February 1996
Resolved 25 August 1995
Navigation
Issued 7 February 1995
Resolved
REPAIR PORT BRIDGE WING RUDDER ANGLE INDICATOR
Condition: Unknown
Due 7 February 1996
Resolved 25 August 1995
Lifesaving
Issued 7 February 1995
Resolved
CONDUCT FIRE AND BOAT DRILLS
Condition: Unknown
Due 7 February 1996
Resolved 25 August 1995
Navigation
Issued 7 February 1995
Resolved
PAINT NAVIGATION SIDELIGHT SCREENS BLACK
Condition: Unknown
Due 7 February 1996
Resolved 25 August 1995
Electrical
Issued 22 April 1994
Resolved
PROVIDE CONTINUOS POWER TO THE GENERAL ALARM SYSTEM USING A POWER SUPPLY INACCORDANCE WITH 46 CFR 113.25-10 (OLD "J", PRIOR TO 1982).
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Construction/Loadline
Issued 15 February 1994
Resolved
CROP & RENEW WASTED SECTIONS IWO PANELS FOR PORT & STBD WING CONTROL STATIONS.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Lifesaving
Issued 15 February 1994
Resolved
PROVE PROPER OPERATION OF GENERAL ALARM LIGHTS IN ENGINEROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Electrical
Issued 15 February 1994
Resolved
PROVIDE CONTINUOUS POWER TO THE GENERAL ALARM SYSTEM USING A POWER SUPPLY IN ACCORDANCE WITH 46CFR 113.25-10. (OLD SUBCHAPTER "J", PRIOR TO 1982).
Condition: Unknown
Due 21 March 1994
Resolved 21 March 1994
Unknown
Issued 15 February 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Construction/Loadline
Issued 15 February 1994
Resolved
PROVIDE PROOF OF ELEVATOR SERVICING CERTIFICATE.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Construction/Loadline
Issued 15 February 1994
Resolved
PROVIDE CARGO CEAR CERTIFICATE.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Electrical
Issued 15 February 1994
Resolved
REMOVE EMERGENCY GENERATOR REMOTE STOPPING CAPABILITIES FROM SWITCHBOARD INENGINEROOM CONTROL ROOM. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 March 1994
Resolved 21 March 1994
Engineering
Issued 15 February 1994
Resolved
PROVE PROPER OPERATION OF GENERAL ALARM LIGHTS IN ENGINEROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Electrical
Issued 15 February 1994
Resolved
REMOVE EMERGENCY GENERATOR REMOTE STOPPING CAPABILITIES FROM SWITCHBOARD INENGINE CONTROL ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Electrical
Issued 15 February 1994
Resolved
PROVE PROPER OPERATION OF GENERAL ALARM LIGHTS IN ENGINEROOM.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Engineering
Issued 15 February 1994
Resolved
PROVE PROPER OPERATION OF SANEX OILY WATER SEPERATOR. OWS NOT TO BE_x001C_ OPERATED UNTIL THIS ITEM IS CLEARED.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Electrical
Issued 15 February 1994
Resolved
PROVIDE CONTINUOUS POWER TO THE GENERAL ALARM SYSTEM USING A POWER SUPPLY IN ACCORDANCE WITH 46 CFR 113.25-10. (OLD SUBCHAPTER "J", PRIOR TO 1982)
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Electrical
Issued 15 February 1994
Resolved
PROVE THE EMERGENCY GENERATOR START/RUN CAPABILITIES ARE NOT AFFECTED WHEN REMOTE ALARMS IN ENGINE ROOM ARE DISABLED IAW MVI POLICY LTR 12-91.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Construction/Loadline
Issued 17 November 1992
Resolved
CONTAMINATED BALLAST TANK IS TO BE ISOLATED, BALLAST IS TO EMPTIED INTO_x001C_ EMPTY FUEL TANK UPON COMPLETION OF VOYAGE. BALLAST TANK IS TO BE CLEANED AND MADE AVAILABLE FOR INSPECTION AND TEST BY USCG MARINE INSPETOR NO LATERTHAN 31 JAN 93.
Condition: Unknown
Due 17 November 1992
Resolved 17 November 1992
Construction/Loadline
Issued 27 October 1992
Resolved
CONTAMINATED BALLAST TANK IS TO BE ISOLATED. BALLAST IS TO BE EMPTIED INTO EMPTY FUEL TANK UPON COMPLETION OF VOYAGE. BALLAST TANK IS TO BE CLEANED AND MADE AVAILABLE FOR INSPECTION AND TEST AT NEXT US PORT BUT NOT LATER THAN 31JAN93.
Condition: Unknown
Due 27 October 1992
Resolved 27 October 1992
Navigation
Issued 27 October 1992
Resolved
PROVE PROPER OPERATION OF VSL GYRO COMPASS TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR PRIOR TO DEPARTURE FROM THE PORT OF NEW YORK.
Condition: Unknown
Due 3 November 1992
Resolved 3 November 1992
Lifesaving
Issued 15 June 1991
Resolved
CONDUCT WEIGHT TEST OF NO. 1 LIFEBOAT IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 June 1991
Resolved 15 June 1991
Electrical
Issued 16 August 1990
Resolved
REPAIR THE PORT AUXILIARY GENERATOR BEFORE SAILING FOREIGN.
Condition: Unknown
Due 16 August 1990
Resolved 16 August 1990
Construction/Loadline
Issued 19 January 1990
Resolved
FREE 4 SCUTTLE ESCAPE HATCHES LEADING FROM 2 DECK TO MAIN DECK. DEMONSTRATE PROPER OPERATION OF SCUTTLES PRIOR TO LEAVING THE PORT OF WILMINGTON, N.C., NO LATER THAN 21JAN90. ITEM TO BE CORRECTED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Fire Fighting
Issued 19 January 1990
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF MACHINERY SPACE-THERMAL FLUID LOOP OF FIRE DETECTION SYSTEM PRIOR TO LEAVING THE PORT OF WILMINGTON, N. C., NO LATER THAN 21JAN90. UNTIL ITEM COMPLETED TO SATISFACTION OF OCMI,A 24 HR. A DAY FIRE WATCH WILL BE MAINTAINED IN THE MACHINERY SPACE.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Fire Fighting
Issued 19 January 1990
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF MACHINERY SPACE-MACHINE SHOP LOOP OF FIRE DETECTION SYSTEM NO LATER THAN 10FEB90. UNTIL ITEM COMPLETED TO SATISFACTION OF COGNIZANT OCMI, A 24 HR. A DAY FIRE WATCH WILL BE MAIN- TAINED IN THE MACHINERY SPACE.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Electrical
Issued 12 November 1989
Resolved
MAKE NECESSARY REPAIRS AND CONDUCT OPERATIONAL TEST OF THE STBD AUXILIARY DIESEL GENERATOR TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 12 November 1989
Resolved 12 November 1989
Fire Fighting
Issued 13 June 1989
Resolved
PROVIDE DATA OR INFORMATION PROVING THAT THE CARGO HOLD SMOKE DETECTOR IS COAST GUARD APPROVED, OR SUBMIT FOR APPROVAL, ADDRESSING THE FACT THAT SUBJECT DETECTOR DOES NOT HAVE AN OLFACTORY DETECTION LINE REQUIRED BY 46CFR76.33-20(C).
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Lifesaving
Issued 13 June 1989
Resolved
WEIGHT TEST STARBOARD LIFEBOAT. 46CFR91.25-15(A)(2)
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Engineering
Issued 13 June 1989
Resolved
PROVE PROPER OPERATION OF AUTOMATIC BILGE PUMP SYSTEM FOR UNMANNED ENGINEROOM OPERATION, AS PER AUTOMATED TEST PROCEDURE.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Construction/Loadline
Issued 13 June 1989
Resolved
OPEN FIRESIDE OF THERMAL FLUID HEATER FOR INTERNAL EXAMINATION AS PER 46CFR61.30-5(B)
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Lifesaving
Issued 2 December 1988
Resolved
REINSTALL FORWARD LIFERAFT
Condition: Unknown
Due 2 December 1988
Resolved 2 December 1988
Navigation
Issued 2 December 1988
Resolved
REMOUNT SHIPS BELL ON FOREMAST
Condition: Unknown
Due 2 December 1988
Resolved 2 December 1988
Deck/Cargo
Issued 2 December 1988
Resolved
PROVE SATISFACTORY OPERATION OF (4) STERN MOORING WINDLESS MOTOR CON- TROLLERS (SOME PARTS USED TO REPAIR FORWARD MOTOR CONTROLLERS).
Condition: Unknown
Due 2 December 1988
Resolved 2 December 1988
Navigation
Issued 2 December 1988
Resolved
REPLACE FORE MAST LIGHT WITH APPROVED FIXTURE
Condition: Unknown
Due 2 December 1988
Resolved 2 December 1988
Lifesaving
Issued 2 December 1988
Resolved
INSTALL LIFEJACKET & LOCKER AT FORWARD LOOKOUT STATION
Condition: Unknown
Due 2 December 1988
Resolved 2 December 1988
Deck/Cargo
Issued 2 December 1988
Resolved
RENEW GUARDS ON PORT/CENTERLINE MOORING WINDLESS CLUTCHES
Condition: Unknown
Due 2 December 1988
Resolved 2 December 1988
Deck/Cargo
Issued 2 December 1988
Resolved
REPAIR OR RENEW F-3, F-4, K-16 & K-17 CONTROLLERS IN FOREPEAK
Condition: Unknown
Due 2 December 1988
Resolved 2 December 1988
Construction/Loadline
Issued 2 December 1988
Resolved
AFFECT PERMANENT REPAIRS TO STB HAWS PIPE SUPPORTS AT SHELL
Condition: Unknown
Due 2 December 1988
Resolved 2 December 1988
Lifesaving
Issued 2 December 1988
Resolved
REINSTALL FORWARD PORT AND STBD LIFERINGS AND WATERLIGHTS
Condition: Unknown
Due 2 December 1988
Resolved 2 December 1988
Construction/Loadline
Issued 2 December 1988
Resolved
RENEW STERN CARGO RAMP FINGERS
Condition: Unknown
Due 2 December 1988
Resolved 2 December 1988
Navigation
Issued 24 September 1988
Resolved
MAKE PERMANENT REPAIRS TO VESSEL'S SECONDARY RADAR AND PROVE OPERATION TO ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 24 September 1988
Resolved 24 September 1988
Lifesaving
Issued 22 June 1988
Resolved
CONDUCT A FIRE AND BOAT DRILL IN THE PRESENCE OF A U.S. COAST GUARD MARINE INSPECTOR PRIOR TO DEPARTURE FROM THE PORT OF JACKSONVILLE, FLORIDA.
Condition: Unknown
Due 22 June 1988
Resolved 22 June 1988
Navigation
Issued 14 October 1986
Resolved
MAKE 3CM RADAR OPERABLE. VESSEL MUST REQUEST NAVSAFETY DEVIATION FROM COTP AT EACH U.S. PORT OF CALL UNTIL RADAR IS REPAIRED.
Condition: Unknown
Due 14 October 1986
Resolved 14 October 1986
Lifesaving
Issued 24 February 1985
Resolved
PROVIDE ONE (1) AUXILIARY LINE FOR THE LINE THROWING APPLIANCE AS REQUIRED BY 46 CFR 94.45-15(A)(6).
Condition: Unknown
Due 24 February 1985
Resolved 24 February 1985
Lifesaving
Issued 24 February 1985
Resolved
PROVIDE ONE ADDITIONAL EXPOSURE SUIT FOR THE BOW LOOKOUT.
Condition: Unknown
Due 24 February 1985
Resolved 24 February 1985