Records from 1984 to 2009. Most recent: inspection, 17 February 2009.
Inspection history · 43
17 February 2009
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3418770
6 October 2008
PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3339647
6 October 2008
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3341451
4 October 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3338387
27 February 2008
PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3155004
5 February 2007
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2867284
26 November 2005
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2538728
19 October 2005
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2518023
21 October 2004
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2225231
28 September 2004
NPV Safety Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2207512
28 August 2004
NPV Safety Exam · ISPS II Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2179630
27 March 2002
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1598266
27 February 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1489629
3 February 2001
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 286749
6 June 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1705979
15 February 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 274700
26 May 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 56143
3 March 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 426098
4 March 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 413327
15 February 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 514638
17 March 1996
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 389017
28 November 1995
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 385269
13 March 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 376063
30 November 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 649482
28 November 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 372671
28 November 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1174483
3 June 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 367391
9 October 1993
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 361697
17 September 1991
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 345936
25 March 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 522347
25 September 1990
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 339537
9 July 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 338132
23 May 1989
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 330575
5 December 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 526824
2 March 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 321604
17 November 1987
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 502455
5 August 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 501639
10 February 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 314224
24 October 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 515860
21 November 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 305477
30 May 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 509521
2 November 1984
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 298760
1 October 1984
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 298251
Fire Fighting › Fire Main › Condition
Issued 17 February 2009
Resolved
Piping for the emergency fire pump in the hydraulic pump room below the forward mooring deck bursted while PSC officers were observing the operation of the emergency fire pump.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2009
Resolved 18 February 2009
Resolution: Vessel''s crew replaced wasted piping in the fire main and PSC Officer witnessed a test of the emergency fire pump. ALL SAT.
Documentation › Certificates/Documents › IOPP Certificate
Issued 6 October 2008
Resolved
Supplememnt for the IOPP certificate should reflect accurate information regarding the vessel's oil pollution prevention equipment. The IOPP certificate states that the maximum throughput of the OWS is .25m3 while the maximum throughput of the OWS is 2.0m3 as per the manufacturers manual. Correct to satisfaction od attending Class surveyor.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 October 2008
Resolved 5 January 2009
Resolution: Received copy of updated IOPP certificate.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 6 October 2008
Resolved
Door fitted in boundary bulkhead of machinery space of category A shall be self closing. Door leading to gasket room has a damaged self closing device. Correct to the satisfaction of attending Class surveyor.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 October 2008
Resolved 5 January 2009
Resolution: Door repair completed.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 19 October 2005
Resolved
SOLAS Cargo Ship Safety Equipment Certificate's Annual Survey was not performed within (3) months (and over 15 months since last survey) of the anniversary date (22JUN) SOLAS 04 CONS I/8(a)(iv) to the Satisfaction of Class.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2005
Resolved 20 October 2005
Resolution: Ches King (Lloyd''s Register) carried out survey per flag authorization and endorsed Safety Equipment Certificate
Operations/Management › Pollution › Retention of Oily Mixture
Issued 19 October 2005
Resolved
Cleanliness of containment below steering gear was insufficient due to excessive hydraulic fluid accumulation. SOLAS 04 CONS I/11
Action required: 705 - Other - as specified
Due 20 October 2005
Resolved 20 October 2005
Resolution: Steering Gear/containment was cleaned prior to boarding team departing vessel.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 19 October 2005
Resolved
Cleanliness of areas surrounding and containment of ship's generators was insufficient due to excessive lube oil accumulation SOLAS 04 CONS I/11 to the Satisfaction of Class
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2005
Resolved 20 October 2005
Resolution: Area was cleaned to the Satisfaction of Class.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 19 October 2005
Resolved
Cleanliness of areas surrounding and containment of ship's main propulsion machinery/plant was insufficient due to excessive lube oil accumulation and was a fire/occupational safety (slips, trips, etc) hazard. to the Satisfaction of Class.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2005
Resolved 20 October 2005
Resolution: Area was cleaned to Satisfaction of class
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 19 October 2005
Resolved
Oily water separator alarm fails to sound when content exceeds 15ppm. MARPOL Annex I/16(2) to the Satisfaction of Class
Vessel could not show proper operation of alarm and Class imposed new Memorandum for repair by 01NOV05
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 October 2005
Resolved 26 November 2005
Resolution: Alarm sounds
Engineering › Steam System (auxiliary) › Piping
Issued 19 October 2005
Resolved
Leaking of Steam Pipe (above 2nd deck level overhead near centerline forward of propulsion plant) through temporary hose clamp patch. to the Satisfaction of Class
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2005
Resolved 20 October 2005
Resolution: Pipe was temporarily repaired and inspected by Lloyd''s surveyor. New condition of class place on vessel for permanent repair to be carried out.
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 August 2004
Resolved
Main Engine Coolant Pipe where 4 sense lines enter - wasted and corroded. Must be addressed & corrected to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 September 2004
Resolution: Received Fax from master of Traviata of class survey of coolant pipe being repaired to Lloyd''s satisfaction.
Engineering › Steering Gear System › Trick Wheel
Issued 28 August 2004
Resolved
Emergency Steering Gear Wheel Mechanism badly deteriorated - un-usable.
bearings needing complete overhual.
Must be overhualed to the satisfaction of class.
(However, tertiary system using buttons on sides of steering pumps available.)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 October 2004
Resolution: Class was on board 10/20/2004 and verified that the bearings of the steering gear had been replaced properly and instructions to the crew on prevention of this again were addressed.
Construction/Loadline › Structures › Deck Plating
Issued 28 August 2004
Resolved
Non-Skid missing in entire steering gear flat.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 October 2004
Resolution: Non skid has been replaced in the steering gear flat.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 28 August 2004
Resolved
Protective matts in front of all main electrical panels missing.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 September 2004
Resolution: Received fax purchase order of ship acquiring large roll of the proper electrical matting.
Fire Fighting › Fire Hoses › Connections
Issued 28 August 2004
Resolved
Spanner wrenches missing - multiple hoses. no fire hoses located on exterior accomodation deck at all.
During emergency fire pump test nozzle was ejected.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 October 2004
Resolution: Received documentation from the manufacturer stating that the fire hoses do not have spanner wrenches that accompany them.
Pollution Prevention/Response › Prevention Equipment
Issued 27 March 2002
Resolved
PROVIDE A CLASS REPORT TO ASCERTAIN THE MATERIAL CONDITION OF VESSELS OWS.
THIS IS TO BE DONE PRIOR TO USE OF OWS. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 28 March 2002
Resolution: cleared via fax recieved from class
Pollution Prevention/Response › Prevention Equipment
Issued 27 March 2002
Resolved
PROVIDE A CLASS REPORT ON THE PLAN FOR REMOVAL/BLOCKING OFF OF OLD UNUSED OWS.
PRIOR TO 27 APRIL 02 THIS CLASS REPORT IS TO BE FAXED TO USCG LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 April 2002
Resolved 28 March 2002
Resolution: cleared via fax recieved from class
Fire Fighting › Miscellaneous Items
Issued 27 March 2002
Resolved
PROVIDE FLAMEPROOF (COVERED) TRASH RECEPTACLES.
(PAINT LOOCKER, ENGINE ROOM, OIL SEPERATOR ROOM BOILER FLAT)
PRIOR TO 27 APRIL 02 LEGACY COMPONENT DESC: Waste Receptacles
Condition: Improper/Lack of Maintenance
Due 27 April 2002
Resolved 21 May 2002
Resolution: Received a fax from the Master of vessel attesting to the purchase of new flame proof (covered) trash cans.
Electrical › Electric Generation Source (emergency)
Issued 27 March 2002
Resolved
EMERGENCY GENERATOR ROOM HAD UNAUTHORIZED SPACE HEATER. REMOVE THE SPACE HEATERAND HAVE CLASS ASCERTAIN A SOLUTION TO THE PROBLEM OF EMERGENCY GENERATOR NOT STARTING IN COLD CLIMATE.BY 27 APRIL 02
Action required: 705 - Other - as specified
Due 27 April 2002
Resolved 22 May 2002
Resolution: Received a Lloyd''s Register class Surveyor report attesting to the removal of the unauthorized space heater and the repair of the heater originally installed.
Construction/Loadline
Issued 15 February 2000
Resolved
LOADLINE PLIMPSEL MARKED TWICE ON HULL. GRIND DOWN/PAINT OVER UNAPPROVED PLIMPSEL MARK TO THE SATISFACTION OF CLASS (ON BOTH SIDES OF THE VESSEL) PRIOR TO 15MAR00.
Condition: Unknown
Due 1 March 2000
Resolved 1 March 2000
Lifesaving
Issued 28 November 1995
Resolved
ADVISED MASTER OF A TOTAL OF 52 FOOD RATIONS (26 PER EACH LIFEBOAT) EXPIRED.
Condition: Unknown
Due 30 November 1995
Resolved 30 November 1995
Unknown
Issued 28 November 1994
Resolved
REPAIR PORT CHAIN WASH DOWN PIPING.
Condition: Unknown
Due 13 March 1995
Resolved 13 March 1995
Lifesaving
Issued 28 November 1994
Resolved
INSTALL PERMANENT RACKS FOR R22 CYLINDER STORAGE.
Condition: Unknown
Due 13 March 1995
Resolved 13 March 1995
Unknown
Issued 28 November 1994
Resolved
VESSEL DID NOT HAVE COMPLETE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 13 March 1995
Resolved 13 March 1995
Documentation
Issued 9 July 1990
Resolved
OIL TRANSFER PROCEDURES INCOMPLETE. MISSING THE NUMBER OF PERSONS REQUIRED_x001C_TO BE ON DUTY DURING OIL TRANSFER OPERATIONS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Documentation
Issued 9 July 1990
Resolved
OIL TRANSFER PROCEDURES INCOMPLETE. MISSING THE DUTIES BY TITLE OF EACH _x001C_ PERSON REQUIRED FOR EACH TRANSFER OPERATION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Documentation
Issued 9 July 1990
Resolved
OIL TRANSFER PROCEDURES INCOMPLETE. MISSING PROCEDURES AND DUTY ASSIGNMENTSFOR TENDING THE VESSEL'S MOORINGS DURING TRANSFER OF OIL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Navigation
Issued 9 July 1990
Resolved
US LIGHT LIST VOL VI, 1990 NOT CURRENTLY CORRECTED. MISSING NOTICE TO MARINERS CORRECTIONS AS FOLLOWS: 1990; 2,3,5,6,7,10,12,14,15,18,21,22,25,27 _x001C_ _x001C_
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Navigation
Issued 9 July 1990
Resolved
US COAST PILOT, 25TH ED, 1989 NOT CORRECTED. MISSING ALL CORRECTIONS,_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Documentation
Issued 9 July 1990
Resolved
OIL TRANSFER PROCEDURES INCOMPLETE. MISSING PROCEDURES FOR ENSURING THAT_x001C_ ALL VALVES USED DURING TRANSFER OPERATIONS ARE CLOSED UPON COMPLETION OF_x001C_ TRANSFER._x001C_ _x001C_
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Documentation
Issued 9 July 1990
Resolved
OIL TRANSFER PROCEDURES INCOMPLETE. MISSING PROCEDURES FOR EMERGENCY SHUTDOWN AND COMMUNICATIONS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Navigation
Issued 1 October 1984
Resolved
CHARTS 12333&12334 NOT ONBOARD AS REQUIRED BY 33CFR164.33.
Condition: Unknown
Due 1 October 1984
Resolved 1 October 1984