MAURY USCG vessel records Sign in
← All vessels

CAPE RACE

CAPE RACE is a 1977 freight ship. The Coast Guard has recorded 122 inspections since 1984, most recently in March 2026, along with 103 deficiencies, 3 operational controls and 7 casualty investigations between 2014 and 2025.

Records from 1984 to 2026. Most recent: operational control imposed, 24 March 2026.

Built
1977
Last inspected
23 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7616377 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225916
Flag
UNITED STATES
366842000 (licence lapsed)
Maury page id
psix-225916

Inspections, by type

…with no type recorded35
Years with a record 30 calendar years (1984–2026)
The 122 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)594.6 ft × 105.6 ft × 65.1 ft
Registered tonnagegross 31,236 / net 9,370
ITC dimensions (L × B × D)594.6 ft × 105.6 ft × 65.1 ft
ITC tonnagegross 31,236 / net 9,370
BuilderK.H.I., LTD · SAKAIDE, JAPAN · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNORFOLK, VA
Trade endorsementsRegistry
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it31236 - Convention (Subpart B), Gross Ton
9370 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

KAFJMMSI 366842000 · expired · compulsorily equipped · granted 9 December 1993, cancelled 9 December 1998
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ANNELIE Towing Vessel · MISLE 488093 · 28 November 2024 · activity 8042177USNS APACHE Public Vessel, Unclassified · MISLE 52830 · 29 April 2022 · activity 7449380

Inspection history · 122

23 March 2026 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8330750
18 March 2026 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8328193
3 December 2025 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8277119
31 July 2025 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8199470
4 April 2025 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8109682
5 December 2024 ACP Drydock Oversight · MTSA/ISPS Verification · Re-Inspection · ACP COI Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8050955
28 November 2024 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8042177
21 November 2024 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8038236
6 December 2023 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7833559
19 May 2023 Periodic Inspection · ACP Additional Oversight – Risk Assessment
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7691204
2 November 2022 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7588179
19 October 2022 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7579939
29 April 2022 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7445203
29 April 2022 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7449380
28 February 2022 Administrative Inspection
Administrative · Activities Europe · Activity 7404528
26 February 2022 Type not recorded
No type recorded · Activities Europe · Activity 7405654
4 February 2022 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7644430
19 January 2022 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7382884
13 January 2022 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7378529
8 January 2022 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7392940
26 August 2021 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7297435
30 November 2020 Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7104126
3 November 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7088997
3 February 2020 Administrative Inspection · Security Breach
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6901910
8 November 2019 ACP COI Oversight · Re-Inspection · MTSA/ISPS Verification · COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6852372
30 September 2019 ACP Drydock Oversight · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6825039
15 November 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6581302
25 October 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6567823
26 September 2018 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6547963
6 September 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6533963
22 August 2018 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6519518
31 May 2018 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6430801
18 April 2018 Periodic Inspection · ACP Periodic Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6394691
18 April 2018 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6403291
6 November 2017 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6307573
6 October 2017 Periodic Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6282477
5 January 2017 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6066908
14 December 2016 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6058218
17 December 2015 ACP Annual Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5782158
9 October 2014 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5015199
11 June 2014 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4885844
16 May 2014 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4860438
17 August 2011 Deficiency Check · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4118278
21 December 2010 ACP Annual Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3888832
11 December 2008 ACP Annual Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3377404
11 January 2008 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3128503
8 January 2008 ACP Annual Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3126810
12 October 2006 ACP Annual Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 2797083
22 September 2006 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2784579
10 August 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2743060
28 March 2006 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2616223
5 December 2005 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2545938
23 September 2005 ACP Annual Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 2499396
14 September 2005 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2492275
19 May 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2362258
16 December 2004 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2260490
30 October 2004 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2230845
27 October 2004 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2229254
22 October 2004 MTSA/ISPS Verification · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2226166
21 September 2004 ACP COI Oversight · MTSA/ISPS Verification
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2200807
27 August 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2184426
3 June 2004 MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2087485
25 May 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2107176
22 May 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2107325
17 May 2004 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2070066
17 May 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2107273
2 February 2004 Annual Inspection · ACP COI Oversight
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1998536
28 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1995712
10 July 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1841607
30 April 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1783459
7 February 2003 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1749409
3 February 2003 Security Inspection · Administrative Inspection · Permit to Proceed
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1742973
2 February 2003 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1741015
30 December 2002 Deficiency Check · Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1723293
8 May 2002 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1614574
10 December 2001 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1407050
4 October 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1074727
18 July 2000 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1389140
14 June 2000 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1050891
19 May 2000 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1049479
7 March 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 817467
7 February 2000 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1112089
16 November 1999 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1408406
14 October 1999 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 787219
13 September 1999 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 784489
22 June 1999 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 780653
11 June 1999 Deficiency Check · Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1381652
25 March 1999 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1113868
22 February 1999 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1131336
11 January 1999 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 810672
30 December 1998 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1368981
18 December 1998 Inclining Experiment
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1429059
4 December 1998 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 808376
2 October 1998 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 806645
22 June 1998 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1469855
17 April 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1124148
6 January 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 784637
4 December 1997 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 777147
9 September 1997 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 786041
30 July 1997 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1378132
2 April 1997 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1105137
15 February 1997 Examination of Repairs
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1102594
26 September 1996 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1141632
11 September 1996 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 74357
10 September 1996 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 951029
28 August 1996 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1087384
19 July 1996 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1463976
17 April 1996 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1080986
1 December 1995 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 872843
1 December 1995 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1182464
22 November 1995 Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1191066
21 November 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1188076
3 November 1995 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1193429
15 September 1995 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1435664
9 July 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 215889
2 March 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 85152
4 December 1994 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 871360
2 September 1994 Initial Certification · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 864362
14 June 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1326848
23 August 1984 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 534603
22 August 1984 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 297634
20 August 1984 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 500701

Deficiency record · 103

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 December 2025 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. EPIRB hydrostatic release was found expired on bridge wing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2026
Resolved 18 December 2025
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 December 2025 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. The hydrant valve for station 12 was found unable to fully close.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2026
Resolved 18 December 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 December 2025 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. The bracket for the portable fire extinguisher at station 48 was found broken off of the bulkhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2026
Resolved 18 December 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 December 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Port navigational light and top fwd masthead light secondary filaments signaled a fault when energized on bridge panel. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 3 December 2025
Resolved 3 December 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 7 April 2025 Resolved
Design Verification and Periodic Safety test procedure documents approved by the Coast Guard must be retained aboard the vessel. U.S. SUPPLEMENT TO ABS RULES FOR STEEL VESSELS CERTIFICATED FOR INTERNATIONAL VOYAGES 14 August 2017 AMERICAN BUREAU OF SHIPPING USCG Approval: 14 August 2017 (16700/2017-821) The design verification and periodic safety tests are to be witnessed by the surveyor [name withheld] must be notified prior to testing and may choose to attend these tests to verify that vital system automation is appropriate to the level of manning requested on the vessel’s Certificate of Inspection. only test procedures were conducted on cape ray for approval.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2025
Resolved 3 December 2025
Resolution: 2025 PSTPs were completed on the CAPE RACE and witnessed by ABS.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 December 2023 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: protection of openings and penetrations in fire resisting divisions. All cargo fire dampers on the port side of the vessel failed to close when tested. Rectify prior to carriage of cargo. 74 SOLAS (20) II-2/14.2.1.1.1, 701a
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 December 2023 Resolved
All electrical apparatus shall be so constructed and so installed that danger of injury in ordinary handling shall not exist. Dead end wires are present in the battery room above the bridge. SOLAS 60 II/27(a)(i)(1), 60a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2024
Resolved 6 December 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 19 May 2023 Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Vessels port side lifeboat was leaking water from the boat plug after the lifeboat was run in the water. 74SOLAS(20)3/20.2
Action required: 10 - Deficiency Rectified
Due 19 May 2023
Resolved 19 May 2023
Resolution: Vessels crew replaced plug.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 19 May 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present resolution to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Fire damper #2 did not close on first attempt. 74SOLAS(20)1/11
Action required: 10 - Deficiency Rectified
Due 19 May 2023
Resolved 19 May 2023
Resolution: Vessels crew greased hardware. Demonstrated proper operation of damper.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 19 May 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present resolution to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Bilge suction IWO shaft alley is held up by chain falls. 74SOLAS(20)1/11
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2023
Resolved 31 May 2023
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 19 May 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present resolution to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. High suction sea water cover missing nuts. 74SOLAS(20)1/11
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2023
Resolved 31 May 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 May 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present resolution to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. MI observed plastic zip ties being used to secure wiring for light in shaft alley, dead end wires in E/R IWO the ballast pumps, loose wiring in stuffing boxes for bilge high level alarm in shaft alley and MSD electrical box in bow thruster space and an opening in a junction box at the entrance of the steering gear compartment. 74SOLAS(20)1/11
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2023
Resolved 31 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 May 2022 Resolved
All marine engineering details, such as boilers, pressure vessels, and fittings, shall be designed, constructed, and installed in accordance with the provisions of this subchapter, except when specifically modified by the regulations in another subchapter in this chapter for a particular type of vessel or where a specific installation may be required or permitted. MSD Fort Macon received notification about the subject vessel having running gear complications. Vessel conducted dive ops and discovered approximately 70% of one blade is missing. Provide local OCMI approved Class report on repairs prior to entering port of North Carolina (Morehead City).
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 9 May 2022
Resolved 19 May 2022
Resolution: Received, reviewed, and accepted class report from ABS resolving the outstanding requirement. See AN 7445203 for further details.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 January 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure ship is fit to proceed to sea without danger to ship or persons aboard. Found bottom of ladder-well wasted on upper trailer deck above electrical room #3. 74SOLAS(20)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2022
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 13 January 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure ship is fit to proceed to sea without danger to ship or persons aboard. Found broken bottom railing and bent middle railing on upper trailer deck above electrical room #4. 74SOLAS(20)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2022
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 13 January 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure ship is fit to proceed to sea without danger to ship or persons aboard. Found hole inside stairwell and hole outside bulkhead in way of frame 221 on main trailer deck. 74SOLAS(20)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2022
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 January 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure ship is fit to proceed to sea without danger to ship or persons aboard. Machinery guards around emergency and (02) primary fire pumps were removed, creating hazard to personnel. 74SOLAS(20)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2022
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 13 January 2022 Resolved
Every crew member shall participate in at least one abandon ship drill and one fire drill every month. Conduct fire and abandon ship drills, to include lowering a lifeboat, in the presence of the attending Coast Guard Marine Inspector prior to activation. 74SOLAS(20)III/19.3.2
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 January 2022
Resolved 19 January 2022
Resolution: Drills ran and witnessed by Coast Guard
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 13 January 2022 Resolved
Upon activation, vessel is to provide MMCs for all crew members when vessel is fully crewed in accordance with the COI manning to the satisfaction of the attending Coast Guard Marine Inspector. 46 CFR 15.401
Action required: 705 - Other - as specified
Resolved 19 January 2022
Resolution: Crew Fully Manned
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 January 2022 Resolved
All ships shall have nautical charts and nautical publications to plan and display the ship's route for the intended voyage. Vessel does not have currently corrected charts or up to date nautical publications. 74SOLAS(20)V/ 19.2.1.4
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 19 January 2022
Resolution: Current Charts and Pubs onboard
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 November 2019 Resolved
Noted multiple fuel leaks in the purifier room at flange connections. Repair to the satisfaction of RO. 74SOLAS(14)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 September 2018 Resolved
Fire main piping in the main deck cargo hold observed to be leaking. Repair fire main piping to the satisfaction of the attending ABS surveyor. 60 SOLAS I/11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 November 2018
Resolved 9 November 2018
Resolution: Approx 20 ft of new pipe was installed and ABS witnessed a pressure test of 1.5 times MAWP
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 September 2018 Resolved
Primary navigation light source on the starboard running light and stern light, and secondary navigation light source on the port running light was inoperative. Repair all navigation lights to the satisfaction of the attending ABS surveyor. 60 SOLAS I/11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2018
Resolution: Burnt out bulbs were discovered and bad cabling were discovered in the stern light. Repairs were witnessed to the satisfaction of attending ABS surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2018 Resolved
Discovered ground in 24V DC charging system panel in gyrocompass room. Correct to the satisfaction of attending ABS surveyor. 60 SOLAS I/11
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2018
Resolved 25 October 2018
Resolution: The leads in the ground detection system were found improperly installed. Repairs were witnessed to the satisfaction of attending ABS Surveyor.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 26 September 2018 Resolved
Ballast vent piping in the main deck cargo hold in way of frame 113 observed to have a hole. Repair ballast vent piping to the satisfaction of the attending ABS surveyor. 60 SOLAS I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2018
Resolved 9 November 2018
Resolution: New spool piece of schedule 40 piping was replaced.
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 26 September 2018 Resolved
Ship's identification number shall be marked visible one each side of vessel's hull. IMO number on the port stern of the vessel was incorrectly marked "766377". Correct IMO marking to the satisfaction of ABS surveyor. 74 SOLAS 14 XI-1/3.4.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2018
Resolved 15 November 2018
Resolution: Correct number was painted
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 September 2018 Resolved
At least two lifebuoys shall be provided with self-igniting lights and self-activating smoke capable of being released from the navigation bridge. Two of the self-igniting lights did not have batteries; corrected on the spot. 60 SOLAS III/21(g)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 26 September 2018
Resolution: Vessel representative installed the correct batteries in the waterlights as requried; all sat.
Engineering › Steering Gear System › Pump
Issued 18 April 2018 Resolved
During operational testing of the steering system using #2 steering pump rudder would not respond. Prove proper operation of steering system using #2 steering pump.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 May 2018
Resolved 22 August 2018
Documentation › Markings/Placards › Lifejacket Placard
Issued 18 April 2018 Resolved
Life jackets and immersion suits shall be placed as to be accessible and their position shall be plainly indicated. Locations of personal life-saving appliances within the engineering operating station were not indicated.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2018
Resolved 22 August 2018
Electrical › Electrical Distribution System (emergency) › Circuit Breaker
Issued 18 April 2018 Resolved
Found 50A breaker in a circuit that is marked for 20A on the emergency switchboard. Provide documentation of class (ABS) for the modification.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2018
Resolved 22 August 2018
Lifesaving › Lifebuoys › Self-Activitating Smoke Signals
Issued 18 April 2018 Resolved
Life saving appliances and arrangements shall be approved by the Administration. Lifebuoy self-activating smoke signals found on the bridge wings are not Coast Guard approved. Replace ensuring quick-release arrangement.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2018
Resolved 22 August 2018
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 18 April 2018 Resolved
Bulkheads of galleys [...] when adjacent to accommodation spaces shall be of steel or equivalent material. Galley (scullery) shutter, when "closed" leaves an open 1 inch gap at the bottom.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2018
Resolved 22 August 2018
Fire Fighting › Structural - A Class Divisions › Control Stations
Issued 18 April 2018 Resolved
Open penetrations through the deck were found in front of the starboard radar console and within the 04-5 instrument locker, both with and without wiring. Verify there is a sufficient amount of fire-stop to enclose the structural fire protection boundary penetrations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2018
Resolved 22 August 2018
Construction/Loadline › Structures › Deck Plating
Issued 18 April 2018 Resolved
Deck area in way of the drain line, located on aft section of the bow is corroded and has been temporarily repaired with an epoxy patch. Repair to the satisfaction of Class.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2018
Resolved 22 August 2018
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 18 April 2018 Resolved
Drain line serving the starboard side CO2 space, and passing through the lower paint locker is wasted, providing free communication of vapor and gases between the spaces. For temporary repair install a flange blank on the drain pipe. Make permanent repairs to the satisfaction of Class.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2018
Resolved 22 August 2018
Engineering › Steering Gear System › Rudder
Issued 6 October 2017 Resolved
Vessel is to demonstrate the proper operation of the steering system prior to departure to the satisfaction of the CG. the steering system was unable to be tested during the inspection due to boom around vessel.
Action required: 705 - Other - as specified
Due 9 November 2017
Resolved 6 November 2017
Fire Fighting › Means of Escape › Corridors
Issued 14 December 2016 Resolved
Vessel's EEBDs have reached 15 year expiration as of December 2016. No evidence of EEBD replacement order provided. Replace all expired EEBDs to the satisfaction of attending ABS surveyor, prior to activation and/or 30 days, which ever comes first.
Action required: 705 - Other - as specified
Due 14 January 2017
Resolved 5 January 2017
Resolution: Recieved a final ABS survey report from surveyor [name withheld], detailing the proper installation of required EEBDs on board the vessel in accordance with vessel Fire and Safety Plan; new EEBDs expire November 2031.
Navigation › Piloting/Steering › Marine Charts
Issued 14 December 2016 Resolved
As the vessel is in a ROS status, nautical charts and publications are not current or corrected. Vessel to supply current and corrected charts and publications to satisfaction of attending marine inspector, upon activation.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 September 2018
Resolved 7 September 2018
Resolution: Attended vessel and cleared outstanding CG-835 for Charts
Personnel › Certificates/Documents/Licenses › License, Master
Issued 14 December 2016 Resolved
As the vessel is in a ROS status and minimally manned, unable to check crew licenses and endorsements. Vessel to supply all crew licenses and endorsements as required by COI to satisfaction of attending marine inspector, upon activation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2018
Resolution: Vessel was fully manned in accordance with its COI & licenses were verified.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 14 December 2016 Resolved
As the vessel is in a ROS status and minimally manned, unable to conduct fire and abandon ship drills. Vessel to conduct fire and abandon ship drills to satisfaction of attending marine inspector, upon activation.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 September 2018
Resolved 7 September 2018
Resolution: Satisfactory drills were witnessed by attending Marine Inspector.
Operations/Management › Drills/Instruction › Not Conducted
Issued 21 December 2010 Resolved
Conduct fire and boat drills and provide crew documentation upon activation to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Resolved 15 December 2011
Resolution: conducted drill''s
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 January 2008 Resolved
Conduct fire, abandon ship & security drills upon activation &/or prior to departure.
Action required: 705 - Other - as specified
Resolved 8 October 2009
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 8 January 2008 Resolved
Provide proof of minimum safe manning (licences, MMD, & STCW) upon activation &/or prior to departure.
Action required: 705 - Other - as specified
Resolved 8 October 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 October 2006 Resolved
Repair/replace mast head light.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 October 2006
Resolved 17 November 2006
Resolution: Received confirmation from class society that these items have been cleared.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 12 October 2006 Resolved
Ensure all fire control plans are approved as required.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 October 2006
Resolved 17 November 2006
Resolution: Received confirmation that this item has been cleared.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 12 October 2006 Resolved
Repair/Replace and prove proper operation of GMDSS Printer (NBDP/HFDSC Printer).
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 October 2006
Resolved 17 November 2006
Resolution: Received confirmation from class that this item has been cleared.
Electrical › Electrical Distribution System (emergency) › Switchboard
Issued 9 November 2005 Resolved
Repair three breaker openings in emergency generator switchboard. Openings must not be larger than .5". Install blanks over openings IAW ABS Rules and to the satisfaction of the attending ABS Surveyor.
Due 16 November 2005
Resolved 5 December 2005
Resolution: Received verification from class that the deficiency has been corrected.
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 November 2005 Resolved
Complete fire and boat drills upon activation to full operating status and prior to getting underway.
Action required: 705 - Other - as specified
Due 9 December 2005
Resolved 22 September 2006
Resolution: Completed satisfactory fire and life boat drills.
Fire Fighting › Fire Pumps › Power Source
Issued 9 November 2005 Resolved
Provide evidence that the fire pump and emergency fire pump lights on the pilot house console illuminate when the fire pumps operate.
Action required: 705 - Other - as specified
Due 16 November 2005
Resolved 5 December 2005
Resolution: Received verification that the deficiency has been corrected.
Fire Fighting › Fire Main › Valves
Issued 21 September 2004 Resolved
Prove proper operation of the fire main relief valve.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 October 2004
Resolved 14 September 2005
Resolution: Received notification that class has cleared this deficincy.
Operations/Management › Drills/Instruction › Not Conducted
Issued 21 September 2004 Resolved
Prior to activation conduct fire and boat drills.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 October 2004
Resolved 14 October 2004
Resolution: Witnessed satisfactory fire and boat drill.
Operations/Management › Casualty Reporting/Post-Casualty Actions
Issued 17 May 2004 Resolved
OPERATIONAL RESTRICTION - When entering the Corpus Christi Ship Channel, the vessel's Master is required to utilize two tug boats and transit during daylight hours only. Vessel may proceed inbound only if local pilot is satisfied that the vessel can safely transit from the sea buoy to the dock.
Action required: 15 - Rectify deficiencies by next port
Resolved 25 May 2004
Pollution Prevention/Response › Prevention Equipment
Issued 30 December 2002 Resolved
Prove proper operation of the oily water separator. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2003
Resolution: Ships crew proved proper operation of the OWS.
Fire Fighting › Miscellaneous Items
Issued 30 December 2002 Resolved
Provide updated fire control plan to indicate newly installed EEBD's and Fire Gear Locker on the vessel. LEGACY COMPONENT DESC: Fire Control Plan
Action required: 705 - Other - as specified
Due 30 January 2003
Resolved 22 January 2003
Resolution: ABS approved the Fire Control Plan for the vessel.
Lifesaving › Lifeboat
Issued 30 December 2002 Resolved
Replace all lifeboat rations, which have lost their vacuum seal. LEGACY COMPONENT DESC: Rations
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2003
Resolution: All lifeboat rations, which have lost their vacuum seal have been replaced.
Personnel › Certificates/Documents/Licenses
Issued 30 December 2002 Resolved
Provide proof of valid MMD and STCW prior to Bosun Gerald McIntyre sailing with vessel. LEGACY COMPONENT DESC: MMD, Bosun
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2003
Resolution: Bosun Gerald McIntyre provided proof of valid MMD and STCW requirements.
Documentation › Certificates/Documents
Issued 30 December 2002 Resolved
Provide proper endorsements to all ABS certificates from last inspection of 12DEC02. LEGACY COMPONENT DESC: ABS Issued Certificates
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2003
Resolution: Documents endorsed.
Operations/Management › Drills/Instruction
Issued 30 December 2002 Resolved
Conduct successful fire and abandon ship drills. LEGACY COMPONENT DESC: Fire & Abandon Ship
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2003
Resolution: Ship successfully completed fire and abandon ship drills.
Engineering
Issued 10 December 2001 Resolved
INSTALL GUARD AROUND EXPOSED PULLEYS ON EMER GEN.
Condition: Unknown
Due 10 January 2002
Resolved 8 April 2002
Resolution: CLEARED BY ABS SURVEYOR
Electrical
Issued 10 December 2001 Resolved
INSTALL A COVER ON BREAKER ACCESS ON EMERGENCY SWITCHBOARD.
Condition: Unknown
Due 10 January 2002
Resolved 15 January 2002
Resolution: CLEARED BY ABS SURVEYOR.
Fire Fighting
Issued 10 December 2001 Resolved
REPAIR OR RENEW FIRE STATION CUT OUT VALVES THAT ARE LEAKING BY WHEN FIRE MAIN IS UNDER PRESSURE. TEST TO BE PERFORMED USING NORMAL SYSTEM OPERATING PRESSURE
Condition: Unknown
Due 10 February 2002
Resolved 15 January 2002
Resolution: CLEARED BY ABS SURVEYOR
Lifesaving
Issued 10 December 2001 Resolved
REMOVE OXYGEN AND ACETYLENE BOTTLES FROM ENGINE ROOM AND INSTALL OUTSIDE OFENG SPACE.
Condition: Unknown
Due 10 January 2002
Resolved 15 January 2002
Resolution: CLEARED BY ABS SURVEYOR
Lifesaving
Issued 10 December 2001 Resolved
REMOVE EXCESSIVE FUEL FROM COAMING IN FUEL PURIFIER ROOM AND REPAIR LEAKS ON PIPES.
Condition: Unknown
Due 10 January 2002
Resolved 15 January 2002
Resolution: CLEARED BY ABS SURVEYOR
Lifesaving
Issued 10 December 2001 Resolved
HAVE CERTIFIED LIFESAVING EQUIPMENT REPAIR FACILITY EVALUATE AND PROVIDE REPORT FOR UNUSUAL NOISE/VIBRATION PORT MOTOR LIFEBOAT TO THE SATISFACTION OF ABS SURVEYOR.
Condition: Unknown
Due 10 January 2002
Resolved 15 January 2002
Resolution: CLEARED BY ABS SURVEYOR
Lifesaving
Issued 10 December 2001 Resolved
PROVE PROPER OPERATION OF 24VDC EMERGENCY POWER DEBARKATION LIGHTS FORWARD OF BOTH LIFEBOAT DAVITS. (BLOWING FUSES)
Condition: Unknown
Due 10 January 2002
Resolved 15 January 2002
Resolution: CLEARED BY ABS SURVEYOR
Fire Fighting
Issued 10 December 2001 Resolved
CONDUCT FIRE AND BOAT DRILLS TO THE SATISFACTION OF THE ATTENDING COAST GUARD INSPECTOR PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 10 December 2002
Resolved 8 May 2002
Lifesaving
Issued 18 July 2000 Resolved
DEMOSTRATE FIRE AND BOAT DRILL, TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR,UPON NEXT VESSEL ACTIVATION AND PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 18 July 2000
Resolved 18 July 2000
Fire Fighting
Issued 7 March 2000 Resolved
SUBMIT DRAWING OF SMOKE/FIRE DETECTION SYSTEM REVISION OF ZONES 4-14 TO MARINE SAFETY CENTER FOR APPROVAL.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Fire Fighting
Issued 11 June 1999 Resolved
Provide updated fire control plan to reflect current vessel configuration with approved IMO symbols.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Fire Fighting
Issued 11 June 1999 Resolved
Provide warning signs(for evacuation) as required inway of all sirens located on all cargo decks.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Lifesaving
Issued 11 June 1999 Resolved
Label general alram lights inway of engineroom.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Fire Fighting
Issued 11 June 1999 Resolved
Relabel or change hoses as needed to Kidde smoke detection cabinet for zones 1-6 to signify correct zone during alarm.
Condition: Unknown
Due 25 August 1999
Resolved 25 August 1999
Fire Fighting
Issued 11 June 1999 Resolved
Provide a placard at the CO2 station with instruction for activating engineroom manual dampner's prior to activating CO2 system.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Navigation
Issued 11 June 1999 Resolved
Repair or renew as needed the center pilothouse window wiper to allow a clear and unobstructed view at the main steering station.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Lifesaving
Issued 11 June 1999 Resolved
Change engine room telephone warning system rotating "red" beacon to distinguish between general alarm system beacons. Blue rotating beacon is recommended.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Fire Fighting
Issued 11 June 1999 Resolved
Renew and prove CO2 sirens inway of engineroom, portside by boiler and all on tank top level deck.
Condition: Unknown
Due 25 August 1999
Resolved 25 August 1999
Fire Fighting
Issued 11 June 1999 Resolved
Provide time delay manufacture spec's to installed adjustable fixed CO2 system time delays showing maximum time adjustment allowed.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Fire Fighting
Issued 11 June 1999 Resolved
Provide zone location placard for installed spronkler system to identify the zone being activated at the control valves.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Lifesaving
Issued 11 June 1999 Resolved
Hydrostatically test all SCBA bottles (10).
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Fire Fighting
Issued 11 June 1999 Resolved
Relabel CO2 system time delay with correct time setting as recommended by manufacture.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Fire Fighting
Issued 25 March 1999 Resolved
PROVIDE ACCURATE AND UPDATED FIRE CONTROL PLANS FOR VESSEL WITH THE APPROVED IMO SYMBOLS.
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Fire Fighting
Issued 30 December 1998 Resolved
VESSEL DOES NOT HAVE ABOARD, AN APPROVED FIRE CONTROL PLAN DEPICTING THE CURRENT CONDITION OF THE VESSEL. PROVIDE AN APPROVED FIRE CONTROL PLAN NO LATER THAN 07FEB99.
Condition: Unknown
Due 30 December 1998
Resolved 30 December 1998
Lifesaving
Issued 22 June 1998 Resolved
MAKE PERMANENT REPAIRS IWO TEMPORARY REPAIR TO STERN TUBE IN LIFEBOAT #2._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Navigation
Issued 22 June 1998 Resolved
PROVIDE CURRENT DEVIATION TABLE FOR MAGNETIC COMPASS._x001C_
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Electrical
Issued 30 July 1997 Resolved
PROVIDE VENTILATION IN WAY OF BATTERY ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 July 1997
Resolved 30 July 1997
Fire Fighting
Issued 30 July 1997 Resolved
PROVIDE PROPOSAL TO OCMI TO PREVENT ACCIDENTAL CO2 DISCHARGE INTO AFT STEERING ROOM FROM CARGO DECK ABOVE AND REPAIR AS APPROVED.
Condition: Unknown
Due 30 July 1997
Resolved 30 July 1997
Electrical
Issued 10 September 1996 Resolved
PRIOR TO DEPARTURE FROM THIS PORT, HMRMS, INSTALL PROPER ELECTRICAL CONNECTIONS I.W.O. EMERGENCY LIGHTS AND POWER TO THE DECK HOUSE IAW 46CFR112.20-15.
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Fire Fighting
Issued 19 July 1996 Resolved
MAKE PERMINENT REPAIRS TO THE HOLED SUCTION PIPING AT THE FIRE AND GENERAL SERVICE PUMP.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Engineering
Issued 19 July 1996 Resolved
PRIOR TO MAKING WELDED REPAIRS TO THE AUX. BOILER HEADER, PROVIDE MSO HAMPTON ROADS THE APPROVED WELD PROCEDURES AND THE WELDER QUALIFICATIONS FOR REVIEW.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Engineering
Issued 19 July 1996 Resolved
UPON COMPLETION OF REPAIRS TO THE AUX. BOILER, CONDUCT A 1 1/2 MAWP HYDROSTATIC TEST OF THE REPAIRS.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Engineering
Issued 19 July 1996 Resolved
UPON COMPLETION OF REPAIRS TO THE AUX. BOILER, CONDUCT AN OPERATIONAL TEST OF ALL SAFETY DEVICES FOR THE BOILER.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Engineering
Issued 19 July 1996 Resolved
SET AND SEAL THE SAFETY VALVES ON THE AUX. BOILER AND THE WASTE HEAT BOILER.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Accommodation/Occupational Safety
Issued 19 July 1996 Resolved
PROVE PROPER OPERATION OF THE FORWARD MARINE SANITATION DEVICE.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Navigation
Issued 19 July 1996 Resolved
REPLACE AFT WHIP ANTENNA IWO AFT MAST.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Lifesaving
Issued 19 July 1996 Resolved
REPLACE MISSING A-60 INSULATION IN FWD FAN ROOMS.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Deck/Cargo
Issued 19 July 1996 Resolved
REPLACE CORRODED TURNBUCKLES, DETERIORATED PADEYES, AND STAYS FOR THE AFTERMAST.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Engineering
Issued 19 July 1996 Resolved
MAKE PERMANENT REPAIRS TO THE CRACKS LOCATED IN THE HEADER ON THE AUX. BOILER.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Construction/Loadline
Issued 22 November 1995 Resolved
MAKE PERMANENT REPAIRS TO 6 INCH CRACKED SEAM WELD IN WAY OF PORT AFTER VOID SPACE SHELL PLATING.
Condition: Unknown
Due 22 November 1995
Resolved 22 November 1995
Electrical
Issued 21 November 1995 Resolved
PROVIDE ENOUGH EMERGENCY LIGHTING IN THE ENGINE ROOM AND THE ENGINE CONTROLROOM TO MEET THE REQUIREMENTS IN 46CFR112.15-1(b).
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Fire Fighting
Issued 15 September 1995 Resolved
PRIOR TO DEPLOYMENT, PROVE PROPER OPERATION OF PRESSURE OPERATED DISCHARGE (STOP) VALVES IN CO2 MANIFOLD FOR FIXED FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 15 September 1995
Resolved 15 September 1995
Navigation
Issued 22 August 1984 Resolved
CHART 12330 AND 12334 NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 22 August 1984
Resolved 22 August 1984
Documentation
Issued 22 August 1984 Resolved
PROPER SHIPPING NAME ENTRIES WERE NOT LISTED FOR AEROSOLS CLASS 2.1,AND BATTERIES WET WITH ACID CLASS 8.
Condition: Unknown
Due 22 August 1984
Resolved 22 August 1984
Deck/Cargo
Issued 22 August 1984 Resolved
SHIPPER USED CORROSIVE PLACARD INSTEAD OF REQUIRED LABEL.
Condition: Unknown
Due 4 December 1995
Resolved 4 December 1995

Casualty record · 7

17 February 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4803040
8 January 2022Routine · role: Involved in a Marine Casualty · activity 7392940
4 February 2022Routine · role: Involved in a Marine Casualty · activity 7644430
26 February 2022Routine · role: Involved in a Marine Casualty · activity 7405654
29 April 2022Routine · role: Subject to Marine Inspection · activity 7449380
28 November 2024Routine · role: Involved in a Marine Casualty · activity 8042177
4 April 2025Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 8109682
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.