Inspection history · 72
15 June 2026
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8405133
5 February 2026
Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8309335
20 January 2026
In-Service Inspection · Vessel Attendance
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8298776
30 September 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8243969
28 August 2025
Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8219867
27 June 2025
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8163288
15 January 2025
Examination of Repairs · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8063859
2 December 2024
In-Service Inspection · Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8041886
28 November 2024
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8042177
12 August 2024
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7979548
25 July 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7965132
9 March 2024
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7884847
1 December 2023
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7832424
22 May 2023
MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7692321
2 May 2023
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7679575
21 June 2022
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7482591
16 July 2021
MTSA/ISPS Verification · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7258433
4 September 2020
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7053581
10 September 2019
MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6808707
26 June 2019
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6788460
24 May 2019
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6712719
27 April 2019
Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 6671985
27 April 2019
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6672599
25 April 2019
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6702538
17 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6514850
24 October 2017
Deficiency Check · Industry Initiated Exam · MTSA/ISPS Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6293093
31 July 2015
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5213772
23 May 2015
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5148520
23 October 2014
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5052458
9 September 2014
MTSA/ISPS Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4981539
19 August 2014
Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5009400
26 March 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4824234
4 September 2013
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4705627
28 December 2012
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4524109
10 April 2012
COE-Administrative
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4286206
21 November 2011
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4192952
25 October 2011
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4175563
30 September 2011
COE-Offshore
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4157884
26 September 2011
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4154205
8 August 2011
MTSA/ISPS Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4109724
30 June 2011
MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4063366
24 March 2011
MTSA/ISPS Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3973442
19 April 2010
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3719441
14 September 2009
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3594183
27 October 2008
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3352699
16 October 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3352910
4 June 2008
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3235928
14 February 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3147559
30 January 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3147366
15 June 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2962780
15 June 2007
Type not recorded
No type recorded · Station Vallejo · USCG Southwest District (CGD-SW) · Activity 2975715
7 March 2007
MTSA/ISPS Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2883388
26 December 2006
Type not recorded
No type recorded · Station Mayport · USCG Southeast District (CGD-SE) · Activity 2845987
22 December 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2845153
16 November 2006
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2830598
14 November 2006
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2820714
16 October 2006
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2802957
5 October 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2508488
29 August 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2478448
22 August 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2470926
25 May 2005
Hawser Check · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2367998
18 February 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2295150
14 July 2004
MTSA Verification
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2131663
27 February 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2014483
20 February 2004
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2010072
17 February 2004
Security Plan Review - VSP
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2008012
10 July 2002
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1644086
2 July 2002
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1640539
27 December 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 189759
27 December 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 771085
12 October 1999
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 27117
11 January 1999
Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1375603
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 20 January 2026
Resolved
MACHINERY AND ELECTRICAL SYSTEMS MUST BE DESIGNED AND MAINTAINED TO PROVIDE FOR SAFE OPERATION. SYSTEM FOR STEERING IS NOT OPERATIONAL.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2026
Resolution: Replaced parts, steering tested sat while underway and at the pier.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 January 2026
Resolved
RAILS OR EQUIVALENT PROTECTION MUST BE INSTALLED NEAR PERIPHERY OF ALL DECKS. HANDRAILS AND BULWARKS SUSTAINED DAMAGE, NO LONGER PROVIDE ADEQUATE PROTECTION FOR CREW.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2026
Resolution: Railings were replaced and welded in.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 January 2026
Resolved
EACH TOWING VESSEL MUST HAVE OPERATIONAL FIRE MAIN. SEVERAL SPOTS OF CORROSION VISABLE ON THE FIREMAIN.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2026
Resolution: Fire main sections were cropped, renewed, and tested sat under full operating pressure.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 20 January 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation, water pupm degraded and rubbing engine mount of fwd outboard side of starboard main.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 February 2026
Resolution: Repaired
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 20 January 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation, water outlet house chafed on starboard main engine, replace in kind.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 February 2026
Resolution: Replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2025
Resolved
"Each Towing Vessel equipped with rudder(s) must have a means to monitor and control the position of the rudder(s) at each operating station."Bridge rudder angle indicator was found reading a maximum of 20 degrees for port and starboard rudder when the mechanical indicator is reading hard port and hard starboard rudder. Vessel must make repairs suitable to CG Marine Inspector's satisfaction prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 August 2025
Resolved 28 August 2025
Resolution: Vessel’s 6 rudders move 20 degree's P & S. While typical is 35 to 35, all rudders appeared to move to full/max extent P & S as designed. Sub M does not mandate a specific degree of rudder movement.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 August 2025
Resolved
"All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable." Observed excessive oil and water in engine room bilge. Remove and properly dispose excessive oil and water.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 August 2025
Resolved 29 August 2025
Resolution: Viewed and verified bilges pumped out.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 August 2025
Resolved
"Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions." Observed fractured weld on frame which supports aft towing wire guide hydraulic ram. Re-weld fractured weld and attach frame as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2025
Resolved 30 September 2025
Resolution: Observed fractured welds, rewelded.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 August 2025
Resolved
“Each cable and wire on a towing vessel must be installed to meet the following requirements…(b) Extension cords must not be used as a permanent connection to a source of electrical power.” In engine room observed numerous electrical cables and wires not properly supported, loose dead end wires and electrical.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2025
Resolved 30 September 2025
Resolution: Various loose and dead end cables appeared to be removed or properly terminated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 August 2025
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: (1) be maintained to ensure proper operation. (2) Be suitable for route and service, and (3) Have suitable propulsion controls to provide the operator full control at each operating station. Conduct and demonstrate vessels propulsion controls and vessels maneuverability in presence of Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 August 2025
Resolved 29 August 2025
Resolution: U/W test with 3 main engines online, steering with pilot house controls, all appeared to opeperte as design.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2025
Resolved
"Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions." Observed holed and excessive wastage of engine room starboard aft supply fan casing. Renew wasted ducting to original.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2025
Resolved 30 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2025
Resolved
"Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions." Observed excessive accumulation of exhaust gas soot, in engine room exhaust pipes, CG MI’s portable gas detector recorded high level of CO2 levels recorded in upper stack access port. Renew all leaking gaskets and or make repairs as required.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 August 2025
Resolved 29 August 2025
Resolution: Port and Center Main Engines exhaust Flanges, crew stated bolts loose and were retighten. With CG MI's portable 4 gas meter, no alarms or leaks detected. Port Engineer stated a portable CO2 alarm would be purchased and installed in main deck passage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 August 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Observed forward lower stbd engine room ship service generator non-operational. 2 of 4 generators non-operational. Demo operation of all 4 Ship Service Generators.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2025
Resolved 29 August 2025
Resolution: Two engine room upper deck SSDG's and exterior 01 deck generator confirmed operational. ER lower stbd fwd SSDG (smaller Generator) remained non-operational. To be repaired within 30 days.
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 28 August 2025
Resolved
"No vessel subject to inspection under 46 U.S.C. 3301 will be navigated unless it is under the direction and control of an individual who holds an appropriate officer endorsement on their MMC." Observed Near Coastal endorsement on Mate's MMC. Must obtain Mate with Oceans endorsement to sail on international voyages.
Action required: 705 - Other - as specified
Due 28 September 2025
Resolved 29 August 2025
Resolution: New Mate in route. Licenses reflects Master of Towing vessel, with Oceans endorsement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2025
Resolved
Exhaust Fans servicing engine room are non operational. Make repairs and demonstrate all engine room fans are operational.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 August 2025
Resolved 29 August 2025
Resolution: Verified all supplies (2) and exhaust (2) engine room vent fan's were operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 August 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Engine Room Lower Stbd side Detroit ship service generator (1 of 2 smaller generators) non operational. Make repairs and demo proper operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2025
Resolved 30 September 2025
Resolution: Verified generator online supplying electrical power to the vessel.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 27 June 2025
Resolved
Each remote valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. Markings for remote valve control for fuel shut offs missing instruction on way to operate them. "PULL TO USE".
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2025
Resolved 15 August 2025
Resolution: Directions for use added
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 June 2025
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Breakers located in laundry room missing labels for loads they serve.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2025
Resolved 15 August 2025
Resolution: Circuit breaker loads listed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 June 2025
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact.
- Permanent extension cord being used on bridge.
- Wing nuts being utilized for battery terminal connections
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2025
Resolved 15 August 2025
Resolution: corrected
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 June 2025
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Racor filters found utilizing leaking petcock valves.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2025
Resolved 15 August 2025
Resolution: Drain valve removed and plugged
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 June 2025
Resolved
The following systems must be equipped with gauges at the machinery location: Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM. Generator found missing required gauges.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2025
Resolved 12 September 2025
Resolution: Generator gauges installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 June 2025
Resolved
Each watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT HATCH—KEEP CLOSED”. Water tight hatch to chain locker missing label.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2025
Resolved 15 August 2025
Resolution: Label installed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 June 2025
Resolved
In addition to the requirements in paragraph (a) of this section, all fire-suppression and detection equipment and systems on board a towing vessel must be maintained in accordance with the attached nameplate, manufacturer's approved design manual, or as otherwise provided in any TSMS applicable to the vessel. Installed CO2 system labeled to be weighed once every 6 months. Vessel is conducting this maintenance yearly. Update maintenance per manufactures requirements.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2025
Resolved 2 September 2025
Resolution: Procured scale to weigh every six months
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 June 2025
Resolved
All portable fire extinguishers, semi-portable fire-extinguishing systems, and fixed fire-extinguishing systems required by this part must be approved by the Commandant (CG-ENG). Portable fire extinguisher found sitting on laundry room floor. Installed extinguisher with required bracket.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2025
Resolved 2 September 2025
Resolution: Extinguisher bracket installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 July 2024
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine.
Fuel shut off valve for ship propulsion did not operate properly.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 July 2024
Resolution: Proper repairs made to fuel shut off.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 July 2024
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards.
Fuel filters systems within engine room that have drain valves on the bottom shall be fitted with a plug to prevent accidental discharge of fuel into the bilge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2024
Resolution: Plugs installed in filter drains.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 July 2024
Resolved
Electrical equipment and electrical cables must be suitably protected from corrosive environments.
Multiple batteries within engine room have corrosion on terminals.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2024
Resolution: Batterys terminals cleaned.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 25 July 2024
Resolved
Aditional equipment. The line throwing appliance must have: An auxiliary line that is at least 1,500 feet long,
Has a breaking strength of at least 40 kilonewtons and be resistant to deterioration from ultra- violet light
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2024
Resolved 31 July 2024
Resolution: Operator obtained aux line.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 25 July 2024
Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3 or 140.4, the operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage. Acceptable methods of securing the device include—
(1) Closing the seacock and removing the handle
(2) Padlocking the seacock in the closed position
(3) Using a non-releasable wire-tie to hold the seacock in the closed position
(4) Locking the door to the space enclosing the toilets with a padlock or door handle key lock.
MI discovered sewage valve not secured or locked.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 July 2024
Resolution: Discussed the discovery with captain and properly locked valve.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 May 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Multiple through bulkhead wire penetrations did not contain any fire stop.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 14 September 2023
Resolution: All penetrations sealed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 May 2023
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Multiple dead ended wires and open junction boxes were found in the engine spaces.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 14 September 2023
Resolution: All dead end wires removed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 May 2023
Resolved
The following systems must be equipped with gauges at the machinery location: (2) Main engine high cooling water temperature. Cooling water temperature gauges at all three main engines were inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 14 September 2023
Resolution: Temp gauge was replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 May 2023
Resolved
The following systems must be equipped with gauges at the machinery location: (1) Main engine lubricating oil pressure and main engine RPM. Center main engine RPM gauge was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 14 September 2023
Resolution: RPM Gauge was replaced
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 May 2023
Resolved
Fixed fire-extinguishing systems must be inspected and tested. Fire main in main hallway had open and un blanked valve, and the associated gauge was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 14 September 2023
Resolution: F/M gauge and valve repaired
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 May 2023
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 14 September 2023
Resolution: Tested strips onboard vessel
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 22 May 2023
Resolved
All training required in this section must be documented in owner or managing operator's records. Vessel could not provide records of crew training required in 140.515.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 14 September 2023
Resolution: Records found updated
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 22 May 2023
Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. This is not meant to restrict access to towing equipment such as winches, drums, towing gear or steering compartment equipment necessary for the operation of the vessel. Bench grinder in the engineering workshop did not have protection guards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 14 September 2023
Resolution: Bench grinder removed
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 June 2022
Resolved
Except as provided in paragraph (a)(8) of this section, each towing vessel must have a fire-detection system installed to detect engine room fires. The owner or managing operator must ensure the following: (3) The system is arranged and installed so a fire in the engine room automatically sets off alarms on a fire detection control panel at the operating station. Fire detection control panel was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 July 2022
Resolution: Vessel's fire detection panel is operational.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 June 2022
Resolved
When the towing vessel is underway, the EPIRB must be stowed in its float-free bracket with the controls set for automatic activation and be mounted in a manner so that it will float free if the towing vessel sinks. Hydrostatic release was expired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 July 2022
Resolution: EPRIB hydrostatic release was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 June 2022
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. 07 of 08 smoke detectors were found inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 July 2022
Resolution: Smoke detectors are operable.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 June 2022
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following. All bilges and voids are kept free of combustible and flammable materials and liquids insofar as practicable. Storage areas are kept free from accumulation of combustible and flammable materials insofar as practicable. Oil found in the bilge, fuel oil under generator, oil filter found in bucket, paint and other flammable materials stored in the forward void space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 5 July 2022
Resolution: Bilges were cleaned, paint and other flammable materials were removed from the forward void space.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 June 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Numerous dead end wires found throughout the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 5 July 2022
Resolution: Deaded end wires are capped.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 June 2022
Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. Navigation lights were inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 5 July 2022
Resolution: Navigations lights are operable.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 June 2022
Resolved
Each integral fuel tank must have a vent that connects to the highest point of the tank, discharges on a weather deck through a bend of 180 degrees, and is fitted with a 30-by-30-mesh corrosion-resistant flame screen. Flame screen had two dime sized punctures, replace.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 5 July 2022
Resolution: Flame screens were replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 June 2022
Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. Machinery guards missing on shafts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 5 July 2022
Resolution: Machinery guards are on shafts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 August 2021
Resolved
All machinery and equipment that is not in proper working order (including missing or malfunctioning guards or safety devices) must be removed; made safe through marking, tagging, or covering; or otherwise made unusable. Identified guards improperly covering rotating machinery equipment.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2021
Resolved 5 September 2021
Resolution: Vessel installed proper machinery guards.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 August 2021
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. Identified heat detectors located in engine room inoperable.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2021
Resolved 5 September 2021
Resolution: Tested fire detection system in e/r. All sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 August 2021
Resolved
A 40-B portable fire extinguisher must be located near the storage room or cabinet. Portable fire extinguisher was not identified near the flammable locker.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2021
Resolved 5 September 2021
Resolution: Crew removed flammable locker from vessel.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 August 2021
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Medicine in first aid kit was expired.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2021
Resolved 5 September 2021
Resolution: Vessel purchased new first aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 23 August 2021
Resolved
Each towing vessel must have a means to monitor and control the amount of thrust, rudder angle, and (if applicable) direction of thrust, at each operating station. The rudder angle indicator did not have full movement to port or starboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2021
Resolved 5 September 2021
Resolution: Rudder angle indicator functions properly.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 July 2021
Resolved
FIXED FIREFIGHTING SYSTEM MEANS A SYSTEM THAT MEETS THE REQUIREMENTS OF 46 CFR SUBPART 76.15 AND THAT IS APPROVED BY COMMANDANT. FIXED FIREFIGHTING SYSTEM DOES NOT MEET REQUIREMENTS IN 46 CFR SUBPART 76.15. IDENTIFIED INCORRECT PIPING INSTALLATION. INSTALL CORRECT PIPING INSTALLATION.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 16 August 2021
Resolved 23 August 2021
Resolution: Vessel added semi-portable extinguisher for the engine compartment
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 July 2021
Resolved
THE MASTER MUST ENSURE THAT ALL HATCHES, DOORS, AND OTHER OPENINGS DESIGNED FOR TO BE WATERTIGHT AND WEATHERTIGHT FUNCTION PROPERLY. IDENTIFIED INSUFFICIENT GASKETS ON WATERTIGHT DOORS. NEED TO INSTALL SUFFICIENT GASKETS ON WATERTIGHT DOORS.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 16 August 2021
Resolved 23 August 2021
Resolution: Installed correct gaskets on all watertight doors
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 16 July 2021
Resolved
PRESSURE VESSELS OVER 5 CUBIC FEET IN VOLUME AND MORE THAN 15 PSI MAXIMUM ALLOWABLE WORKING PRESSURE MUST MEET ABS RULES FOR BUILDING AND CLASSING STEEL VESSELS UNDER 90 METERS (295 FEET) IN LENGTH (INCORPORATED BY REFERENCE, SEE §136.112 OF THIS SUBCHAPTER), PART 4, CHAPTER 1, SECTION 1. IDENTIFIED SEVERELY CORRODED PRESSURE VESSEL.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 16 August 2021
Resolved 23 August 2021
Resolution: Pressure vessel was successfully hydro tested in the presence of a Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 July 2021
Resolved
NO PERSON MAY INTENTIONALLY DRAIN OIL OR HAZARDOUS MATERIAL INTO THE BILGE OF A TOWING VESSEL FROM ANY SOURCE. IDENTIFIED ACCUMULATION OF OIL IN BILGES OF MACHINERY SPACE. DISPOSE OF OIL IN BILGES PROPERLY.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 16 August 2021
Resolved 5 September 2021
Resolution: Vessel cleaned bilges.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 April 2019
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. STBD MDE had a fuel leak from the secondary spin on fuel filter causing atomized fuel to spray on the center line MDE causing a hazardous condition in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 April 2019
Resolution: Engines secured to prevent fire, ships crew replaced secondary fuel filter.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 17 August 2018
Resolved
IMO: Vsl is broadcasting no IMO #, LENGTH DIFF: greater/smaller than expected vessel length
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 November 2018
Resolution: All AIS information is correct.
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 30 September 2011
Resolved
Per the minimum safe manning document for the ELSBETH III O.N. 1075804, while on an international voyage of greater than 600 miles, the vessel shall be manned with two (2) Licensed Engineers.
Smith Marine Inc manned the ELSBETH III (O.N. 1075804) with only one (1) U.S. Licensed Engineer, violating 46 CFR 15.825(b), failing to have the required number of assistant engineers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 25 October 2011
Resolution: Inspection activity will be referred to enforcement for violation.
Personnel › Certificates/Documents/Licenses › License, Assistant Engineer
Issued 19 April 2010
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2010
Resolved 5 May 2010