Inspection history · 170
4 September 2020
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7053581
27 August 2020
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7059497
12 April 2020
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6942373
13 March 2020
In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6926233
18 October 2019
MARPOL Annex I Examination · Annual Inspection · Deficiency Check · MTSA Verification · In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6827370
28 June 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6734700
29 May 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6698024
14 March 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6642546
13 March 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6713801
15 August 2018
Internal Structural Exam · COI Inspection · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6496544
13 April 2018
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6395480
12 April 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6390102
20 November 2017
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6309886
15 November 2017
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6307421
15 November 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6308279
1 November 2017
Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6298960
19 October 2017
Annual Inspection · MARPOL Annex I Examination · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6291267
3 February 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6079734
14 December 2016
MARPOL Annex I Examination · Periodic Inspection · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6054096
15 November 2016
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5835795
27 February 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5834570
16 November 2015
MARPOL Annex II Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5764076
16 October 2015
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5748647
14 September 2015
Examination of Repairs · Cargo Tank Internal · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5717662
2 March 2015
Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5077245
28 January 2015
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5061164
18 December 2014
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5040982
5 December 2014
Annual Inspection · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5033959
12 November 2014
In-Service Inspection · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5021892
28 January 2014
MARPOL Annex II Examination · MARPOL Annex I Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4790772
15 August 2013
Cargo Tank Internal · COI Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4685928
8 July 2013
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4648807
8 July 2013
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4653866
16 February 2012
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4245619
8 November 2011
Administrative Inspection · Annual Inspection · MARPOL Annex I Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4185499
3 November 2011
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4181677
3 November 2011
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4181748
9 September 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4150738
14 July 2011
Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4086887
20 December 2010
Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3913774
4 January 2010
Damage Survey · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3658362
5 June 2009
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3495866
10 April 2009
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3450096
14 August 2008
COI Inspection · Construction Oversight · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3298277
17 June 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3239741
15 February 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3149940
3 January 2008
Annual Inspection · Deficiency Check · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3122816
2 December 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3108182
17 November 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3100121
4 November 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3092799
25 September 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3066430
1 August 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3014481
26 March 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2895514
15 December 2006
Ballast Water Examination · MTSA Verification · Periodic Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2838797
6 October 2006
Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2795373
7 August 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2739711
19 July 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2718385
29 June 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2695388
17 August 2005
Administrative Inspection · Construction Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2466137
10 August 2005
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2458538
21 June 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2397915
14 June 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2390215
14 March 2005
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2309829
1 February 2005
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2284186
11 January 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2272970
8 July 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2180897
8 June 2004
MTSA Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2114628
2 June 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2090915
20 May 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2073192
18 March 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2026922
29 January 2004
Examination of Repairs · In-Service Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1996783
27 August 2003
Cargo Tank Internal · Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1889080
20 August 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1995356
19 December 2002
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1722638
18 November 2002
MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1705503
7 March 2002
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1492147
13 November 2001
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1453960
8 November 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 4437
8 November 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1478713
28 September 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1362453
21 September 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1071607
28 December 2000
COI Inspection · MARPOL Annex II Examination · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1361932
4 May 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1059171
30 March 2000
Initial Construction-Excluding Oversight
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1048262
10 January 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 484917
10 September 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 482557
4 May 1999
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1369174
4 February 1999
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 792101
2 February 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 502895
25 August 1998
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 798456
6 August 1998
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1131051
24 July 1998
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1453507
9 May 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 525420
5 February 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 667016
3 February 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 76707
27 January 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 464713
22 December 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 452585
12 July 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 471009
1 July 1997
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 777941
13 May 1997
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1424401
8 March 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 451334
1 November 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 457010
25 July 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 667006
19 July 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1086464
19 July 1996
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1400392
8 July 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 485601
14 January 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 457845
6 September 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 508938
2 June 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 448591
15 May 1995
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1186668
4 March 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 518845
27 December 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 666994
1 December 1994
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1153479
6 September 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 441758
7 July 1994
Deficiency Check · Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1175285
3 July 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1172497
20 May 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 367027
19 March 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 366441
18 February 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 479561
18 January 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 363867
29 November 1993
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1358222
15 October 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 49934
9 September 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 360706
16 August 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 475351
13 August 1993
Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 834207
9 April 1993
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 840900
5 March 1993
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1142904
14 January 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 536324
28 September 1992
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1266050
19 August 1992
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1257094
16 July 1992
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 475713
10 December 1991
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 455274
5 September 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 666964
21 June 1991
COI Inspection · Damage Survey · Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1218776
1 June 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 477835
24 September 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 493392
12 April 1990
Deficiency Check · Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 910445
26 February 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 512969
10 January 1990
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1215998
14 December 1989
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 334392
20 November 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 911201
5 October 1989
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1314639
15 July 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 529412
13 February 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1037568
4 January 1989
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 518969
23 October 1988
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 445848
13 July 1988
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 898420
23 May 1988
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1352149
17 September 1987
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1006386
4 September 1987
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1312362
9 May 1987
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 472911
9 October 1986
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1009564
16 August 1986
Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1298935
24 July 1986
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 310502
27 January 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 479164
9 August 1985
Credit Drydock · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1290984
19 July 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 497964
7 January 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1296906
3 November 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 510566
19 October 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1282291
6 September 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1282864
28 August 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 972810
29 March 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973042
20 March 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 971906
7 January 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1279563
27 December 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1279562
4 August 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 966498
16 April 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1273008
26 August 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1273073
29 July 1981
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1275078
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 24 October 2019
Resolved
The hig-level and tank overfill alarm required by paragraph (a) must activate am alarm in the event of a loss of power to the alarm syatem.
The hihg and overfill alarm system did not produce an alarm when the main sourse of power was shutdown.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2019
Resolved 25 October 2019
Resolution: Received BERGAN report attesting to proper operation of the barges high/overfill alarm system.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 24 October 2019
Resolved
Each cargo tank of a tank barge must have a high-level indicating devices that indicates visually the level of liquid in the cargo tank when the liquid is within range of one meter.
The meter stick above the designated cargo slop tank does not operate correctly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2019
Resolved 25 October 2019
Resolution: Received report that the meter stick is fully operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 October 2019
Resolved
WHERE CONDUIT IS INSTALLED , THE APPLICABLE REQUIREMENTS OF EITHER NFPA NEC 2002 OR IEC 60079 MUST BE FOLLOWED.
4 CONDUIT OPENINGS WERE FOUND UNDER THE MAIN CARGO DECK HOUSE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2019
Resolved 25 October 2019
Resolution: Recieved pictures and documentation showing the conduit opennings have been correcetly sealed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 24 October 2019
Resolved
A DETECTION SYSTEM SHALL BE PERMANENTLY INSTALLED TO SENSE CARGO LEAKS. THE DETECTORS SHALL BE LOCATED WITHIN THE SPACE SO AS TO PERMIT THE SENSING OF AN INITIAL LEAK AND PREVENMT AN UNDETECTED GAS ACCUMULATION.
THE BARGE IS EQUIPED WITH A FIXED GAS DETECTION SYSTEM THAT SAMPLES BALLAST TANKS AND BOW/STERN RAKES. THERE IS
NO HISTORY OF THE SYSTEM BEING CORRECTLY CALIBRATED.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2019
Resolved 25 October 2019
Resolution: Received report attesting to proper operation/calibration of the barges Fixed Gas detection system
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 24 October 2019
Resolved
A TANKSHIP THAT CARRIES FLAMMABLE CARGO MUST HAVE TWO VAPOR DETECTORS , AT LEAST ONE VAPOR DETECTOR MUST BE PORTABLE.
THE BARGE HAS TWO PORTABLE VAPOR GAS DETECTORS, HOWEVER THE SPAN GAS USED TO CALIBRATE THE PORTABLE AND PERSONAL DETECTORS WAS FOUND EXPIRED.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2019
Resolved 25 October 2019
Resolution: Received documentation that the new and correct span gas for the portable gas detectors was onboard.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 18 October 2019
Resolved
THE REMOTE QUICK ACTING MANUAL SHUTDOWN SHALL BE INSTALLED ON THE ENGINE SO AS TO PROVIDE A QUICK AND EFFECTIVE MEANS OF STOPPING THE ENGINE.
THERE WERE NUMEROUS REMOTE SHUTDOWN LOCATIONA FOUND THAT WERE PULLED AWAY FROM THE RENDERING THEM NOT OPERATIONAL
Action required: 15 - Rectify deficiencies by next port
Due 18 October 2019
Resolved 23 October 2019
Resolution: ATTENDING INSPECTORS WITNESSED CORRECTION AND OPERATIONAL TESTING OF REMOTE PULL STATIONS.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 18 October 2019
Resolved
THE REMOTE QUICK ACTING MANUAL SHUTDOWN SHALL BE INSTALLED ON THE ENGINE SO AS TO PROVIDE A QUICK AND EFFECTIVE MEANS OF STOPPING THE ENGINE.
THE AFT ENGINE WOULD NOT SHUT DOWN DURING TESTING OF THE REMOTE MANUAL SHUTDOWN.
Action required: 15 - Rectify deficiencies by next port
Due 18 October 2019
Resolved 23 October 2019
Resolution: ATTENDING INSPECTORS WITHNESSED OPERATIONAL TESTING OF REMOTE SHUTDOWN LOCATIONS
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 18 October 2019
Resolved
UNLESS THE CARGO TANKS ARE GAS FREE, THE MASTER/OPERATOR SHALL ENSURE THE INERT GAS SYSTEM IS OPERATED AS NECESSARY TO MAINTAIN AN INERT ATMOSPHERE IN THE CARGO TANKS.
THE INERT GAS GENERATOR (IGG) REGULATING VALVE ABOVE THE IGG HOUSE IS LEAKING AIR.
Action required: 15 - Rectify deficiencies by next port
Due 18 October 2019
Resolved 23 October 2019
Resolution: ATTENDING INSPECTORS WITNESSED PROPER OPERATION OF THE BARGES IGG SYSTEM.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 18 October 2019
Resolved
UNLESS THE CARGO TANKS ARE GAS FREE, THE MASTER/OPERATOR SHALL ENSURE THE INERT GAS SYSTEM IS OPERATED AS NECESSARY TO MAINTAIN AN INERT ATMOSPHERE IN THE CARGO TANKS.
THE IGG P/V BREAKER FLUID IS LOW AND THERE WAS NO DOCUMENTATION OF THE LAST INSPECTION.
Action required: 15 - Rectify deficiencies by next port
Due 18 October 2019
Resolved 23 October 2019
Resolution: ATTENDING INSPECTORS VERIFIED GLYCOL/WATER LEVEL INSIDE THE P/V BREAKER.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 18 October 2019
Resolved
ELECTRICAL INSTALLATIONS ON A VESSEL MUST ENSURE PROTECTION OF THE CREW AND VESSELS FROM ELECTRICAL HAZARDS.
TWO HARD GROUNDS WERE DISCOVERED ON THE BARGES 480V AND 120V SYSTEMS.
Action required: 15 - Rectify deficiencies by next port
Due 18 October 2019
Resolved 24 October 2019
Resolution: ATTENDING INSPECTORS VERIFIED BOTH GROUNDS WERE RECTIFIED. BARGE INSTALLED NEW TRANSFORMER.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 March 2019
Resolved
While moored at Mt. Airy facility vessel was struck by Red flag barge MM 70. OSG 244 is ABS Classed, ABS Surveyor attended vessel. Prior to departure from port of New Orleans vessel shall affect repairs to the through hull damage in the fore peak approx. 18" above the waterline. Prior to movement vessel shall lighter/shift cargo/shift ballast in order to increase the distance between the through hull damage and the water line as per the CG approved plan. Once this is accomplished vessel is authorized transit to repair facility as per the CG approved transit plan.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 28 March 2019
Resolved 15 March 2019
Resolution: SAT class (ABS) report received. CG-835v cleared.
Construction/Loadline › Structures › Deck Plating
Issued 15 November 2017
Resolved
Make 1P/1S ballast tank and forepeak tank available for inspection IAW 46 CFR 31.10-21(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2017
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 19 October 2017
Resolved
Residual cargo slop tank on port side of barge connected to the vacuum stripping tank is provided with a goose neck vent only. Cargos require P/V venting. Vessel must provide system approval or change goose neck vent to approved P/V.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 20 November 2017
Resolution: P/V valve was added to residual tank.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 19 October 2017
Resolved
Radar ullage system on #5P cargo tank is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2017
Resolved 1 November 2017
Resolution: Received, reviewed and accepted Bergen Tech report attesting to proper repair and operation of the liquid gauge system on the 5P tank. All sat.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 3 February 2017
Resolved
Barges PFD's and Immersion suits are not marked properly. Additionally, need lights.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 3 March 2017
Resolution: Attended barge, M/I verified correct quanity and markings of three life jackets/immerion suits onboard.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 3 February 2017
Resolved
Provide barge with life saving plan, showing the location of life saving gear onboard. In addition, post life saving plaques to indicate the stowed location of gear onboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 3 March 2017
Resolution: Attended barge, M/I verified life saving and fire-fighting arrangement plan was onboard.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 3 February 2017
Resolved
Mark egress routes on barge iaw policy ltr 16-04 for safe routes in an emergency.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 3 March 2017
Resolution: Attended barge, M/I verified the markings routes were properly installed for egress as indiacated by onboard SMS and plan.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 3 February 2017
Resolved
Install life raft deploying instruction at the location of the life raft onboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 3 March 2017
Resolution: Attended barge, M/I verified life raft instructions were posted near life raft and servicing/maintenance instructions onboard.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 14 December 2016
Resolved
Provide proof of compliance with CVC Policy Letter 16-04 (Conditional Occupancy).
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 10 March 2017
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 14 December 2016
Resolved
The #5 Cargo pump engine has an active leak on the Fuel pump. Repair or replace prior to use.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 December 2016
Resolution: Received tech report indicating the Fuel oil pump was replaced and test run; all sat.
Engineering › Pressure Vessel › Relief Valve
Issued 14 December 2016
Resolved
The Start Air receiver has a broken relief valve.
Action required: 705 - Other - as specified
Resolved 14 December 2016
Resolution: A new relief valve was installed and tested, all sat.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 14 December 2016
Resolved
Install lagging on the #1 generator turbo exhaust piping.
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 19 December 2016
Resolution: New lagging was installed on the #1 generator turbo; all sat.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 2 March 2015
Resolved
Prove proper operation of the anchor winch.
Action required: 705 - Other - as specified
Due 2 March 2015
Resolved 7 March 2015
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 5 December 2014
Resolved
Barge is equipped with 3 primary generators. Crew could not demonstrate operation and required shutdowns for #1 generator. Demonstarte required shutdowns of #1 generator by date specified to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 5 January 2015
Resolved 18 December 2014
Resolution: Observed required shutdowns for #1 generator to the satisfaction of the attending Marine Inspector.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 11 November 2014
Resolved
Due to inop cargo pump leaking oil onto the exhaust lagging and causing the exhaust lagging to catch on fire, duty marine inspector wrote 835 to fix cargo pump and replace lagging prior to operation of the cargo pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 November 2014
Resolved 11 November 2014
Resolution: Local technician came onboard replaced the elbow of the engine and replaced lagging. Tested the engine and determined all sat. cleared 835.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 8 July 2013
Resolved
Isolate failed cargo pump until such a time that proper repairs are made. Submit a class/tech report to the CG upon completion of repairs.
Action required: 705 - Other - as specified
Resolved 2 October 2013
Resolution: Replaced pump seal.
Engineering › Compressed Air System (control) › Compressor
Issued 3 January 2008
Resolved
Repair or renew non-operating RPM indicator on Detroit Diesel for ships service air
Action required: 705 - Other - as specified
Due 2 February 2008
Resolved 7 February 2008
Resolution: Witnessed operational RPM indicator.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 3 January 2008
Resolved
Identify and repair leak on fuel supply line to the #4 cargo pump.
Action required: 705 - Other - as specified
Due 2 February 2008
Resolved 7 February 2008
Resolution: Leak corrected.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Location
Issued 15 December 2006
Resolved
Mount B-V entinguisher in IGS room IAW 46CFR 34.50-20
Due 15 January 2007
Resolved 3 May 2007
Electrical › Electrical Distribution System (service) › Panelboard
Issued 15 December 2006
Resolved
Properly label motor controllers in generator room IAW 46 CFR 111.70-3
Due 15 January 2007
Resolved 3 May 2007
Engineering › Diesel Engine (auxiliary) › Valve
Issued 15 December 2006
Resolved
Install a remote means of stopping the hotel generator and air compressor engine from outside the space IAW 46 CFR 58.01-25.
Due 2 January 2007
Resolved 3 May 2007
Construction/Loadline › Structures › Rake
Issued 11 August 2005
Resolved
Free the dogs for the aft/starboard rake entry door. Dogs are siezed closed and must be capable of being opened. 46 CFR 42.15
Due 11 September 2005
Resolved 30 December 2005
Documentation › Manuals/Policy Documentation › Procedures and Arrangements Manual (NLS)
Issued 11 August 2005
Resolved
Provide Proof of Coast Guard issued cargo aurthority authorizing carriage of NLS. Prior to carriage of NLS's, provide proof of proper Procedures and Arrangements Manual for NLS carriage.
Due 11 September 2005
Resolved 30 December 2005
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 11 August 2005
Resolved
Provide proof of approved Shipboard Oil Pollution Emergency Plan.
Due 11 September 2005
Resolved 30 December 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 11 August 2005
Resolved
Remove Excess oil from deck of generator house
Due 12 August 2005
Resolved 9 December 2005
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 11 August 2005
Resolved
Clean and maintain cleanliness of generator and generator windings. Cleaning shall be maintained until removal of generator engine or permanent fix.
Due 18 August 2005
Resolved 9 December 2005
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 11 August 2005
Resolved
Remove generator or permanently mitigate oil entry into windings. Windings shall be routinely cleaned until this discrepancy is remedied.
Due 30 November 2005
Resolved 30 December 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 1 February 2005
Resolved
Calibrate cargo piping gauges.
Due 1 March 2005
Resolved 6 March 2005
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 1 February 2005
Resolved
Calibrate VCS gauges.
Due 1 March 2005
Resolved 6 March 2005
Engineering › Diesel Engine (auxiliary) › Pump, Positive Displacement
Issued 1 February 2005
Resolved
Replace plastic/nonmetallic petcocks from #1 cargo pump and generator Racor fuel filters; replace with metallic plugs.
Due 1 March 2005
Resolved 6 March 2005
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 1 February 2005
Resolved
Repair ullage opening in tank top hatches of cargo tanks #1 P & S where knife edge has deteriorated.
Due 1 March 2005
Resolved 28 February 2005
Resolution: Made permanent repairs.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 1 February 2005
Resolved
Stencile "OIL SERVICE" on cargo transfer hoses.
Due 1 March 2005
Resolved 6 March 2005
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 1 February 2005
Resolved
Repair aligning pin on portside forward VCS manifold.
Due 1 March 2005
Resolved 6 March 2005
Electrical › Electric Generation Source (service) › Panelboard
Issued 1 February 2005
Resolved
Block opening in electrical panel, front cover (in generator room).
Due 1 March 2005
Resolved 6 March 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 February 2005
Resolved
Repair stern navigational light.
Due 1 March 2005
Resolved 6 March 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 18 November 2002
Resolved
Service portable fire extinguisher as per 46 CFR 31.10-18(e) and provide copy of servicing report to cognizant OCMI. LEGACY COMPONENT DESC: Service
Due 18 December 2002
Resolved 19 December 2002
Resolution: Vessel Rep. provided copy of servicing report for all fire fighting extinquishers and equipment to OCMI.
Documentation › Safety/Response Plans/Programs
Issued 18 November 2002
Resolved
Provide proof to cognizant OCMI that annual review of Vessel Response Plan and Shipboard Oil Pollution Emergency Plan was conducted as per 33 CFR 155.1070. LEGACY COMPONENT DESC: Vessel Response Plan
Condition: Unknown
Due 18 December 2002
Resolved 19 December 2002
Resolution: Vessel Rep. provided documentation proof of annual review (Letter to Commandant G-MOR-2) for Vessel Response Plan (VRP) and Ship Board Emergency Response Plan (SOPEP).
Operations/Management › Equipment Service/Testing
Issued 18 November 2002
Resolved
Conduct hydrostatic test on cargo piping & all non-metallic transfer hoses as per 33 CFR 156.170 and provide copy of servicing report to cognizant OCMI. LEGACY COMPONENT DESC: Cargo Piping
Due 18 December 2002
Resolved 19 December 2002
Resolution: Vessel Rep. provided proof of hydrostatic testing via service report of all cargo piping, relief valves, pressure uages, piping, and fuel hoses.
Operations/Management › Equipment Service/Testing
Issued 18 November 2002
Resolved
Conduct verification test on all cargo pressure gauges as per 33 CFR 156.170(c)(3) and provide copy of certification to cognizant OCMI. LEGACY COMPONENT DESC: Cargo Pressure Gauges
Due 18 December 2002
Resolved 19 December 2002
Resolution: Vessel Rep. provided
Deck/Cargo
Issued 28 December 2000
Resolved
Stencil engine remote stops.
Condition: Unknown
Due 28 December 2000
Resolved 28 December 2000
Deck/Cargo
Issued 28 December 2000
Resolved
Install pins on vapor manifold connection.
Condition: Unknown
Due 28 December 2000
Resolved 28 December 2000
Documentation
Issued 28 December 2000
Resolved
Update vessel's vessel response plan.
Condition: Unknown
Due 28 December 2000
Resolved 28 December 2000
Documentation
Issued 28 December 2000
Resolved
Update vessel's Shipboard Oil Pollution Emergency Plan.
Condition: Unknown
Due 28 December 2000
Resolved 28 December 2000
Documentation
Issued 28 December 2000
Resolved
Update vessel's oil transfer procedures.
Condition: Unknown
Due 28 December 2000
Resolved 28 December 2000
Deck/Cargo
Issued 28 December 2000
Resolved
Stencil safe working load on both hose cranes.
Condition: Unknown
Due 28 December 2000
Resolved 28 December 2000
Documentation
Issued 24 July 1998
Resolved
PROVIDE THIS OFFICE WITH THE REQUIRED REPORTS FOR THE PERIODICAL ENHANCED SURVEY. COPIES OF THESE REPORTS MUST ALSO BE MAINTAINED ONBOARD THE VESSEL.
Condition: Unknown
Due 11 September 1998
Resolved 4 September 1998
Deck/Cargo
Issued 24 July 1998
Resolved
PROVE PROPER OPERATION OF THE EMERGENCY SHUTDOWN FOR THE #2 CARGO PUMP ENGINE IN THE PRESENCE OF A USCG MARINE INSPECTOR. CARGO IS NOT TO BE DISCHARGED WITH THE #2 CARGO PUMP UNTIL SATISFACTORILY TESTED AND WITNESSED.
Condition: Unknown
Due 7 August 1998
Resolved 7 August 1998
Documentation
Issued 24 July 1998
Resolved
PROVIDE "WRITTEN" COMPANY POLICY TO TOWBOAT OPERATOR "SEAFARER" SPECIFYING BRIDGE RESOURCE MANAGEMENT POLICY AND PROCEDURES" AS PER NVIC 2-97 AND 33 CFR 157.
Condition: Unknown
Due 7 August 1998
Resolved 7 August 1998
Deck/Cargo
Issued 13 May 1997
Resolved
Shorten excessively long hydraulic hoses on deck winches, not to exceed 30"._x001C_ _x001C_ 46 CFR 56.60-25(c)(4)_x001C_
Condition: Unknown
Due 13 May 1997
Resolved 13 May 1997
Documentation
Issued 13 May 1997
Resolved
Provide Oil Record Book Part II prior to departure._x001C_ _x001C_ _x001C_ 33 CFR 151.25
Condition: Unknown
Due 13 May 1997
Resolved 19 May 1997
Engineering
Issued 13 May 1997
Resolved
Replace wasted pipe coupling connecting relief valve to air receiver._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1997
Resolved 19 May 1997
Deck/Cargo
Issued 13 May 1997
Resolved
Prove operation of Liquid Overfill Protection system at P/S shore connections._x001C_ _x001C_ 46 CFR 39.20-9(b)(9)(i)_x001C_
Condition: Unknown
Due 13 May 1997
Resolved 19 May 1997
Documentation
Issued 13 May 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 June 1997
Resolved 1 July 1997
Documentation
Issued 19 July 1996
Resolved
T/B OCEAN 244 OPERATED FROM 15JUL-19JUL96 WITHOUT OBTAINING A REINSPECTION.
Condition: Unknown
Due 24 July 1996
Resolved 24 July 1996
Deck/Cargo
Issued 3 July 1994
Resolved
MAKE PROPER PERMANENT REPAIRS TO SIDESHELL IN WAY OF #1 PORT CARGO TANK, PRESENTLY PATCHED WITH EPOXY. TO BE TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 3 July 1994
Resolved 3 July 1994
Deck/Cargo
Issued 3 July 1994
Resolved
GAS FREE AND MAKE AVAILABLE FOR INSPECTION #1 PORT CARGO TANK. TO BE TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 3 July 1994
Resolved 3 July 1994
Deck/Cargo
Issued 19 August 1992
Resolved
REPAIR OR REPLACE TACKOMETER ON #2 & #5 CARGO PUMP ENGINE AND S/S GENERATOR.
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Engineering
Issued 19 August 1992
Resolved
INSTALL FUEL FILTER FLAME SHIELDS #1, & #3 CARGO PUMP ENGINE.
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Electrical
Issued 19 August 1992
Resolved
REPAIR GENERATOR GROUND DETECTOR SYSTEM.
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Deck/Cargo
Issued 19 August 1992
Resolved
REPLACE OR REPAIR OIL PRESSURE GAGE ON #2 & #4 CARGO PUMP ENGINE.
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Deck/Cargo
Issued 5 October 1989
Resolved
CONDUCT HYDROSTATIC TEST OF CARGO PIPING AT ALLOWABLE WORKING PRESSURE. MAINTAIN A COPY ON BOARD.
Condition: Unknown
Due 5 October 1989
Resolved 5 October 1989
Deck/Cargo
Issued 5 October 1989
Resolved
PROVIDE OPEN AND CLOSED INDICATORS ON ALL NON-RISING STEM VALVES IN CARGO SYSTEM (46CFR56.20-9(A)).
Condition: Unknown
Due 5 October 1989
Resolved 5 October 1989
Deck/Cargo
Issued 13 July 1988
Resolved
DEMONSTRATE OPERATION OF ANCHOR WINDLASS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 13 July 1988
Resolved 13 July 1988
Deck/Cargo
Issued 13 July 1988
Resolved
MAKE AVAILABLE FOR COAST GUARD INSPECTION OPERATIONAL TEST OF CARGO PUMP PRIME MOVERS EMERGENCY SHUTDOWNS.
Condition: Unknown
Due 13 July 1988
Resolved 13 July 1988
Unknown
Issued 13 July 1988
Resolved
AIR-POP TEST RELIEF VALVE ON SERVICE AIR RECEIVER IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 13 July 1988
Resolved 13 July 1988
Deck/Cargo
Issued 4 September 1987
Resolved
DEMONSTRATE THE OPERATION OF THE CARGO PUMP ENGINE REMOTE SHUTDOWNS TO THE SATISFACTION OF THE ATTENDING COAST GUARD INSPECTOR PRIOR TO CONDUCTING CARGO PUMPING OPERATIONS BUT NOT LATER THAN 15OCT87.
Condition: Unknown
Due 4 September 1987
Resolved 4 September 1987
Unknown
Issued 28 August 1984
Resolved
CLEAN UP OIL AND OIL DRY IN ALL PUMP ROOMS AND OFF MAIN DECK PRIOR TO SAILING.
Condition: Unknown
Due 28 August 1984
Resolved 28 August 1984
Navigation
Issued 28 August 1984
Resolved
FREE UP ALL RUNNING LIGHT SWITCHES AND MOUNT THE STARBOARD SWITCH PRIOR TO SAILING.
Condition: Unknown
Due 28 August 1984
Resolved 28 August 1984
Unknown
Issued 28 August 1984
Resolved
REMOVE THE RUBBER FUEL OIL OVERFLOW LINE FROM THE GENERATOR FUEL OIL DAY TANK PRIOR TO SAILING.
Condition: Unknown
Due 28 August 1984
Resolved 28 August 1984
Construction/Loadline
Issued 28 August 1984
Resolved
REPLACE/FREE ALL DOGS ON THE FOLLOWING: (A) WEATHERTIGHT DOORS TO THE PUMPROOMS; (B) BATTERY BOXES; (C) BOW RAKE; (D) STERN VOID.
Condition: Unknown
Due 28 August 1984
Resolved 28 August 1984
Unknown
Issued 28 August 1984
Resolved
LUBRICATE AND TEST THE EMERGENCY SHUTDOWNS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 28 August 1984
Resolved 28 August 1984
Electrical
Issued 28 August 1984
Resolved
INSTALL FLAME SCREENS ON ALL RUNNING LIGHT BATTERY BOXES.
Condition: Unknown
Due 28 August 1984
Resolved 28 August 1984
Documentation
Issued 28 August 1984
Resolved
PROVIDE A REPORT OF THE CARGO PIPING TEST.
Condition: Unknown
Due 28 August 1984
Resolved 28 August 1984
Documentation
Issued 28 August 1984
Resolved
BRING THE OIL TRANSFER PROCEDURES INTO COMPLIANCE WITH THE REGULATIONS.
Condition: Unknown
Due 28 August 1984
Resolved 28 August 1984
Unknown
Issued 28 August 1984
Resolved
PERFORM TEMPORARY REPAIRS TO EXPANSION TRUNK ULLAGE OPENINGS TO ATTAIN A POSITIVE SEAL.
Condition: Unknown
Due 28 August 1984
Resolved 28 August 1984
Electrical
Issued 28 August 1984
Resolved
REMOVE EXCESS UNUSED WIRING ON S/S GENERATOR.
Condition: Unknown
Due 28 August 1984
Resolved 28 August 1984
Unknown
Issued 28 August 1984
Resolved
PERFORM TEMPORARY REPAIRS TO THE WASTED GENERATOR AIR INLET DUCTING, MAKINGPERMANENT REPAIRS AT SCHEDULED DRYDOCK.
Condition: Unknown
Due 28 August 1984
Resolved 28 August 1984
Unknown
Issued 28 August 1984
Resolved
MAKE TEMEPORARY REPAIRS TO ALL HYDRAULIC LEAKS, TAKING MEASURE TO PREVENT AN OIL POLLUTION INCIDENT UNTIL PERMANENT REPAIRS COMPLETED.
Condition: Unknown
Due 28 August 1984
Resolved 28 August 1984
Unknown
Issued 28 August 1984
Resolved
MAKE PERMANENT RPAIRS TO THE SEALING RINGS IN EACH STAND PIPE SO AS TO PRO-VIDE FOR A COMPLETE SEAL WHEN FLAME SCREENS ARE IN PLACE. UNTIL COMPLETED,ALL OPENINGS SHALL REMAIN CLOSED EXCEPT WHEN GAUGING IS CONDUCTED BY A TANKERMAN.
Condition: Unknown
Due 28 August 1984
Resolved 28 August 1984
Unknown
Issued 28 August 1984
Resolved
MAKE PERMANENT REPAIRS TO EXPANSION TRUNK ULLAGE FLAME SCREEN SEAL RINGS.
Condition: Unknown
Due 28 August 1984
Resolved 28 August 1984
Construction/Loadline
Issued 29 March 1984
Resolved
TEMPORARY REPAIRS ARE TO BE EXAMINED AND FIXED IF NECESSARY TO RETAIN STRUCTURAL INTEGRITY AND WATER TIGHTNESS.
Condition: Unknown
Due 29 March 1984
Resolved 29 March 1984
Unknown
Issued 29 March 1984
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE CHROMALLOY I, DN532585.
Condition: Unknown
Due 29 March 1984
Resolved 29 March 1984
Construction/Loadline
Issued 29 March 1984
Resolved
TEMPORARY REPAIRS TO BE REMOVED AND PERMANENT REPAIRS TO BE CONDUCTED TO DAMAGE IN BOW VOID PORT SIDE WHEN VESSEL IS NEXT DRYDOCKED.
Condition: Unknown
Due 29 March 1984
Resolved 29 March 1984
Unknown
Issued 20 March 1984
Resolved
PERMIT TO PROCEED TO PT ARTHUR, TX VIA TAMPA, FL TO DISCHARGE CARGO, DUE TOCOLLISION DAMAGE IN FWD VOID, PORT SIDE.
Condition: Unknown
Due 20 March 1984
Resolved 20 March 1984