Records from 2011 to 2026. Most recent: inspection, 20 July 2026.
Documentation record
Registered dimensions (L × B × D)131.4 ft × 38.0 ft × 22.0 ft
Registered tonnagegross 267 / net 182
ITC dimensions (L × B × D)131.4 ft × 38.0 ft × 22.0 ft
ITC tonnagegross 920 / net 276
BuilderVT HALTER MARINE INC · ESCATAWPA, MS, UNITED STATES · built 2011
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 11 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it920 - Convention (Subpart B), Gross Ton
267 - Regulatory (Subpart C or D), Gross Ton
276 - Convention (Subpart B), Net Ton
182 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 40
20 July 2026
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8442359
3 June 2025
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8151610
7 May 2025
Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8130490
22 June 2024
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7939930
12 June 2024
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7933749
7 June 2024
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7930118
18 April 2024
COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7897575
30 October 2023
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7816218
30 October 2023
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7834671
10 October 2023
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7806372
3 September 2023
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7784333
5 April 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7663506
11 February 2023
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7636032
11 July 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7504324
11 July 2022
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7513129
8 June 2022
MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7471779
12 July 2021
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7253656
5 April 2021
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7170327
13 October 2020
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7076060
17 September 2020
In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7060408
28 May 2020
MTSA/ISPS Verification
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6962102
2 July 2019
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6733918
28 June 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6734700
29 May 2019
Examination of Repairs · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6697780
29 May 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6698024
13 March 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6713801
15 November 2018
Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6636515
15 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6512945
14 September 2016
Administration · MTSA/ISPS Verification · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6000745
10 May 2016
MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5875656
27 January 2016
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5804814
26 January 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5803629
23 January 2016
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5802688
22 March 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5088221
22 March 2015
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5091495
22 March 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5155972
10 June 2013
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4616583
26 January 2012
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4232722
23 September 2011
Administration · Industry Initiated Exam · MTSA/ISPS Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4151882
20 August 2011
Plan Review (Other than "T")
Administrative · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 4377701
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 22 July 2026
Resolved
46 CFR 136.200(b)
Each towing vessel certificated under the provisions of this sub chapter must be in full compliance with the terms of the COI.
- MF/HF radio capability has been rendered inoperational due to lightning strike. Vessel is restricted to domestic voyage until repairs have been made to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 8 August 2026
Resolution: Received preliminary report from ABS stating that repairs have been made.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 20 July 2026
Resolved
33 CFR 164.72(a)(6)
Towing vessels must be equipped with the following equipment, as applicable to the area of operation:(c)Electronic position-fixing device, satisfactory for the area in which the vessel operates.
- Vessel experienced a lightning strike effecting the reliability of their GPS and ECDIS. Make repairs to the satisfaction of the attending TPO surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 June 2025
Resolved
46 CFR 143.205a - Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onvboard under normal and emergency conditions,
Vessel port MDE shutdown due to loss of their #4 cylinder.
Vessel is to transit to Port Everglades to affect repairs. Notify CG upom completion of repairs.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 6 June 2025
Resolved 6 June 2025
Resolution: Crew replaced complete power pack with spares.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 April 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. On April 5, 2023, the OSG Endurance experienced a loss of power to the bridge and a loss of steering control. 46 CFR 143.205
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 April 2023
Resolution: Technician report indicated a failed battery selector switch was the cause of the issue. Vessel made temporary repair with a spare switch. Switch replaced to oriiginal and proper operation verified to the satisfaction of the attending ABS Surveyor.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 17 September 2020
Resolved
The Safety Management System should include procedures ensuring that non-conformities are reported to the company, investigated, and analyzed with the objective of improving safety and pollution prevention. SMS chapter ENV-01 Section 5 states when a activity poses an environmental risk, QR-SQE-25 Environmental Aspects Assessment Matrix is required to be followed Additionally chapter MR-04 requires a corrective action report to be generated if a defect presents a hazard to the crew or the environment. No objective evidence was provided to indicate that such reports were generated for the following: 1) Ballast water treatment system not capable of treating water that exceeds the water clarity standards required for UV intensity to be effective. 2) System found showing the following alarm: W154 UVR(1): UV intensity USCG low. System flow maintained at 50% Process not compliant.
An internal audit is required to be conducted focusing on requirements for report non-conformities as outlined above.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2020
Resolved 13 October 2020
Resolution: Cleared deficiency via email, received audit report satisfying 835. See documents for audit.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018
Resolved
Vsl is broadcasting: Measure length in FT (Vsl dimension Must be measured in meters).
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 September 2018
Resolved 2 October 2018
Engineering › Compressed Air System (start air) › Control Gear
Issued 27 January 2016
Resolved
Vessel experienced repeated propulsion casualties to the starboard main engine. Notify cognizant COTP/OCMI prior to entry to each US port. Provide technician and ABS surveyor report detailing cause and rectificiation to CG marine inspector to clear.
Action required: 705 - Other - as specified
Due 10 February 2016
Resolved 28 January 2016
Resolution: Received ABS report #NO3075897 stating engines serviced by OEM authorized mechanics and witnessed sat 4 hour operational test.
Engineering › Diesel Engine (propulsion-reduction gear) › Distributor (air start)
Issued 23 January 2016
Resolved
VSL experienced propulsion loss with starbaord main engine due to faulty oil mist detector and air start system. see attached documents dated 23jan16 for further detail.
Condition: Improper/Lack of Maintenance
Due 30 January 2016
Resolved 23 January 2016
Resolution: VSLreplaced faulty components for oil mist detector and air start system. operation and repairs verified by technical representative and ABS class surveyor. see attached for details. 835 cleared
Electrical › Electric Generation Source (service) › Generator
Issued 22 March 2015
Resolved
Vessel reported an electrical power loss that affected steering while transitting LMR.
Action required: 705 - Other - as specified
Due 22 March 2015
Resolved 22 March 2015
Resolution: Received a tech report from Rio Marine stating battery charger for ECM was faulty and replaced. Additionally received ABS report attesting to proper operation of all generators and steering.