MAURY USCG vessel records Sign in
← All vessels

UNFAIR LADY

UNFAIR LADY is a 1979 freight ship. The Coast Guard has recorded 33 inspections since 1984, most recently in July 2008, along with 29 deficiencies — 2 with no resolution recorded — and 6 operational controls.

Records from 1984 to 2008. Most recent: inspection, 1 July 2008.

Built
1979
Last inspected
1 July 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7625055 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
226020
Flag
SPAIN
—
Maury page id
psix-226020

Inspections, by type

…with no type recorded26
…past their stated due date2
Years with a record 17 calendar years (1984–2008)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it38864 - Dead Weight, Metric Ton
46743 - Displacement, Metric Ton
11941 - Convention (Subpart B), Net Ton
22600 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ANNOULA Freight Ship · MISLE 354919 · 7 January 2003 · activity 1728127

Inspection history · 33

1 July 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3252941
29 June 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3251469
21 September 2004 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2200245
5 February 2003 Ballast Water Examination · Re-Inspection · Deficiency Check · Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1731560
7 January 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1727310
7 January 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1728127
15 November 2002 Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1706064
2 October 2002 MARPOL Annex V Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1679631
31 August 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1669769
6 July 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1642081
21 May 2002 Security Inspection · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1618947
12 April 2002 Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1603931
19 January 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 286219
12 January 2001 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 286361
7 March 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 275433
22 August 1999 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 432030
13 December 1998 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 423585
8 June 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 416383
5 November 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 409502
8 February 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 400254
22 June 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 359032
22 May 1992 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 448852
26 December 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 450899
26 June 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1215042
25 June 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 337749
3 July 1989 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 331147
23 April 1989 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 329903
20 September 1988 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 325550
29 January 1988 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 442896
14 July 1987 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 317306
2 July 1987 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 317023
25 July 1985 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 303235
4 June 1984 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 492378

Deficiency record · 29

Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 1 July 2008 No resolution recorded
Vessel's fire doors in the main stair tower do not close properly. Vessel must make proper repairs to the doors to the satisfaction of attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2008 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 July 2008 No resolution recorded
Vessel does not have safety guards on the emergency generator. Vessel must install proper guards on E/G to the satisfaction of attending Coast Guard Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 July 2008 — due date passed with no resolution recorded
Engineering › Generator (propulsion-electric)
Issued 5 February 2003 Resolved
No.1 generator has excessive fuel oil leak from cylinder No.2.
Action required: 705 - Other - as specified
Due 7 February 2003
Resolved 6 February 2003
Resolution: Received proper documentation from captain, cleared deficiency.
Engineering › Steering Gear System
Issued 8 January 2003 Resolved
No.2 solenoid assembly for steering control system malfunctioned resulting in a loss of steering.
Action required: 705 - Other - as specified
Due 8 January 2003
Resolved 5 February 2003
Resolution: No.1 and No.2 steering pumps, No.1 and No.2 solenoid assemblies, hydraulic oil, and filters have been replaced with new parts.
Navigation › Piloting/Steering
Issued 7 January 2003 Resolved
Vessel's steering system malfunctioned resulting in a collision. LEGACY COMPONENT DESC: Steering gear system
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 January 2003
Resolved 5 February 2003
Resolution: Received class report from Lloyd''s Register satisfying requirement. See attached documents to NEWMS activity #1731560.
Fire Fighting › Firemans Outfit
Issued 2 October 2002 Resolved
Vsl's firemans outfit boots are in unsatisfactory condition LEGACY COMPONENT DESC: Boots
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 4 October 2002
Resolution: Vsl''s fireman''s outfit boots were replaced
Fire Fighting › Firemans Outfit
Issued 2 October 2002 Resolved
Vsl's fireman's outfit jacket in unsatisfactory condition. LEGACY COMPONENT DESC: Protective Clothing
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 4 October 2002
Resolution: Vsl''s fireman''s outfit jacket was replaced
Engineering › Steering Gear System
Issued 31 August 2002 Resolved
A condition of class has now been recommended due 9/02, tugs to be advised while in confined waters pending replacement of the STBD hydraulic pump and fine tuning of the system. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2002
Resolved 15 November 2002
Resolution: Received LR class report satisfying requirement.
Fire Fighting › Self-contained Breathing Apparatus
Issued 12 April 2002 Resolved
Fireman unfamiliar with how to properly don SCBA and equipment. The [name withheld] did not help or correct the problem. SOLAS 74A III/ 19.3.4.2.1
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 18 April 2002
Resolved 18 April 2002
Resolution: Conducted drill and found that crew members have been training. They are now very familiar with their equipment.
Fire Fighting › Fire Hoses
Issued 11 April 2002 Resolved
Fire Hoses and Nozzles in drill area in poor condition and not available for immediate use. SOLAS 74A II-2/21. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 April 2002
Resolved 18 April 2002
Resolution: Examined equipment and found in good condition.
Fire Fighting › Miscellaneous Items
Issued 11 April 2002 Resolved
Crewmembers unfamiliar with connection of hoses and unfamiliar with proper length of hose in drill location. SOLAS 74A III19/3.4.2.1
Action required: 17 - Rectify deficiencies prior to departure
Due 11 April 2002
Resolved 18 April 2002
Resolution: Conducted drill and found that crewmembers are familiar with their safety equipment.
Personnel › Training
Issued 11 April 2002 Resolved
Fire drills not properly conducted. See attached drill assessment. SOLAS 74A III 193 3.1 LEGACY COMPONENT DESC: Fire Fighting Basic
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 11 April 2002
Resolved 18 April 2002
Resolution: Drills conducted properly as per SOLAS.
Operations/Management › FireFighting
Issued 11 April 2002 Resolved
Crew could not perform a satisfactory fire drill in accordance with SOLAS 74A III 19 on two separate occasions. ISM external audit to be conducted. ISM Clause 1.2.3 of the Code, & ISM Clause 8.0 of the Code.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 11 April 2002
Resolved 18 April 2002
Resolution: Conducted satisfactory drill.
Accommodation/Occupational Safety
Issued 7 March 2000 Resolved
Insecticied stored in Hospital space._x001C_ ILO 147_x001C_
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Lifesaving
Issued 7 March 2000 Resolved
Life bouys not on deck with lights._x001C_ Solas Ch III 7.1_x001C_
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Accommodation/Occupational Safety
Issued 7 March 2000 Resolved
Exposed wiring for lighting in messman/oiler crew quarters._x001C_ ILO 147,& Solas Ch II reg.45_x001C_
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Accommodation/Occupational Safety
Issued 7 March 2000 Resolved
Toilets not functioning in crew's quarters due to water conservation._x001C_ ILO 147_x001C_
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Construction/Loadline
Issued 8 June 1998 Resolved
Properly permanently mark the assigning authority of the vessel's loadlines. _x001C_ ILLC 66/ Annex I/8.
Condition: Unknown
Due 13 December 1998
Resolved 13 December 1998
Lifesaving
Issued 8 June 1998 Resolved
Repair/renew as arginal the deteriorated saltwater cooling piping for the #3 generator and the #1 generator in way of the bilge._x001C_ SOLAS 74 (amended) I/II(a)._x001C_ _x001C_
Condition: Unknown
Due 13 December 1998
Resolved 13 December 1998
Lifesaving
Issued 8 June 1998 Resolved
Repair/renew as orginal the deteriorated saltwater cooling piping for the generators in way of the lower level engineroom, port side._x001C_ SOLAS 74 (amended) I/II(a)._x001C_ _x001C_
Condition: Unknown
Due 13 December 1998
Resolved 13 December 1998
Lifesaving
Issued 8 June 1998 Resolved
Repair/renew as arginal all deteriorated sections of freshwater cooling piping for the #1, #2, and #3 generators in way of the temporary patches._x001C_ SOLAS 74 (amended) I/II(a)._x001C_ _x001C_
Condition: Unknown
Due 13 December 1998
Resolved 13 December 1998
Engineering
Issued 8 June 1998 Resolved
Properly repair/renew as orginal the packing for the #1 lubrication oil pump._x001C_ SOLAS 74 (amended) I/II/(a).
Condition: Unknown
Due 13 December 1998
Resolved 13 December 1998
Fire Fighting
Issued 8 June 1998 Resolved
Repair/renew as orginal all fireboxes on the main deck that are currently tied shut to the vessel's structure._x001C_ SOLAS 74 (amended) II-2/21.
Condition: Unknown
Due 13 December 1998
Resolved 13 December 1998
Navigation
Issued 22 June 1993 Resolved
DURING THE NAVIGATIONAL SAFETY CHECK IT WAS NOTICED THAT THE VESSEL'S CHARTS 11412 AND 11413 FOR THE TRANSIT OF TAMPA BAY WARE OUTDATED.
Condition: Unknown
Due 22 June 1993
Resolved 8 July 1993
Navigation
Issued 22 June 1993 Resolved
DURING THE NAV SAFETY BOARDING IN WAS NOTED THAT THE VESSEL DIDN'T HAVE CHART 11414 ON BOARD WHICH IS REQUIRED TO TRANSIT TAMPA BAY.
Condition: Unknown
Due 22 June 1993
Resolved 8 July 1993
Lifesaving
Issued 26 June 1990 Resolved
RELEASE CABLE CONNECTING FORE AND AFT RELEASE GEAR IN PORT LIFE BOAT MISSING. STBD LIFE BOAT CABLE NOT PROPERLY SECURED REPAIR TO BE MADE PRIORTO DEPARTING BOSTON.
Condition: Unknown
Due 26 June 1990
Resolved 26 June 1990
Unknown
Issued 23 April 1989 Resolved
33 CFR 156.120 (O) THE VESSEL WHICH HAD A CAPACITY OF APPROXIMATELY 1279.02 CUBIC METERS OF FUEL OIL DID NOT HAVE EACH DRAIN CLOSED BY THE MECHANICAL MEANS REQUIRED BY 33 CFR 155.310. (I.E. VESSELS PORT AND STARBOARD CONTAINMENT WERE PLUGGED WITH WOODEN PLUGS.
Condition: Unknown
Due 2 July 1989
Resolved 23 April 1989
Documentation
Issued 23 April 1989 Resolved
33CFR155.750(A)(1),(3),(4),(5),(6) THE VSL WHICH HAD A CAPACITY OF APPROX. 1279.02 CUBIC METERS OF FUEL OIL DID NOT HAVE OIL TRANSFER PROCEDURES THAT INCLUDED CARGO INFORMATION, PROCEDURES FOR EMPTYING THE CONTAINMENT, DUTIESBY TITLE, TENDING MOORINGS, AND COMUNICATIONS.
Condition: Unknown
Due 2 July 1989
Resolved 23 April 1989
Navigation
Issued 2 July 1987 Resolved
33 CFR 164.33(A)(2)(II) VESSEL DID NOT HAVE A CURRENTLY CORRECTED COPY OF COAST GUARD LIGHT LIST OR FORIEGN EQUIVALENT ON BOARD.
Condition: Unknown
Due 2 July 1987
Resolved 2 July 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.