Inspection history · 50
18 June 2026
PSC B · COC-CVE Quarterly
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8407596
20 December 2025
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8285717
26 May 2025
COC-CVE Quarterly · PSC B
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8140269
11 December 2024
PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8045467
4 June 2024
PSC B · COC-CVE Quarterly
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7925729
3 January 2024
COC-CVE Annual
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7844597
17 September 2023
PSC A · Administrative Inspection · COC-CVE Quarterly · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7792534
4 January 2023
PSC A · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7615947
30 November 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7602179
13 October 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7577057
24 August 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7542957
10 August 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7530049
23 June 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7519725
15 June 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7478327
1 June 2022
COC-CVE Quarterly · Ballast Water Examination · PSC B
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7465901
24 May 2022
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7465601
12 May 2022
In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7449549
17 March 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7413607
23 February 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7400887
12 December 2021
Deficiency Check · Ballast Water Examination · COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7366038
1 November 2021
Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 7343492
14 October 2020
Administrative Inspection
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 7081583
26 June 2020
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7055626
13 April 2020
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7030390
17 March 2020
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6928050
1 November 2019
COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6846048
30 September 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6824727
17 September 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6814024
30 August 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6799284
15 August 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6784786
8 August 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6777276
1 August 2019
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6791952
17 May 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6698306
6 May 2019
Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6668597
14 July 2018
COC-CVE Quarterly · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6465412
10 July 2018
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6545266
21 May 2018
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6438482
4 May 2018
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6406135
7 February 2018
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6350984
5 January 2018
ISPS III Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6332912
8 July 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6202196
26 March 2017
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6108883
10 January 2017
Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6068841
22 September 2016
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6006589
17 August 2016
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5976233
24 July 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5952491
23 July 2016
COC-CVE Quarterly · NPV Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5950660
15 June 2016
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5899945
8 June 2016
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5902346
10 January 2016
Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5794022
01 - Certificates & Documentation › 011 - Ships Certificates › Passenger Ship Safety (including exemption)
Issued 22 June 2026
No resolution recorded
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed deck in starboard dress room adjacent to the deck 05 theater collapsed and covered with carpet, lower adjacent space on deck 04 bosun store. 74SOLAS20 I/11a. 50AC.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2026 — due date passed with no resolution recorded
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 20 December 2025
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Crew member on life boat number 5 was not familiar with emergency fuel shut off location, nor procedures.
74 SOLAS 20 III/19.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 January 2026
Resolved 20 December 2025
Resolution: Conducted training with all lifeboat commanders.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 June 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. On starboard side lifeboats, PSCOs observed retro-reflective tape was not in serviceable condition. 74 SOLAS 20 III/20.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 June 2024
Resolution: Ship's crew replaced all retro-reflective tape.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 June 2024
Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photo luminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers to identify the routes of escape and readily identify the escape exits. PSCO observed on Deck 07, spa corridor low-location lighting was blocked by a beverage table. 74 SOLAS 01 II-2/28.1.10
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 4 June 2024
Resolution: Ship's crew removed the beverage table that was blocking low-location lighting.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 September 2023
Resolved
After any survey of the ship under regulations 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. PSCO observed the Port and Starboard black/grey water system screening tanks and permeate tanks modified with plastic hoses connecting the tanks. Fixed piping was missing.
74 SOLAS 2001, I/11(b)
50 a,c
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2023
Resolved 29 September 2023
Resolution: Received LR report attesting to proper repair of system.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 September 2023
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for service for which they are intended and shall be so installed and protected as to reduce to minimum any danger to persons on board, due regard paid to moving parts, hot surfaces and other hazards. PSCO observed a continuous water leak from heeling pump, 0AA3, from mechanical seal.
74 SOLAS 2001, II-1/26.1
50 a,c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2023
Resolved 29 September 2023
Resolution: Received LR report attesting to proper repair and operation of pump.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 January 2023
Resolved
A gauge indicating the pressure in the system shall be provided at each section stop valve and at a central station. The pressure gauge at section valve S38 on deck 12 was inoperable. 74SOLAS(01)II-2/12.2.3. 16C.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2023
Resolved 4 January 2023
Resolution: Gauge was replaced before finishing the exam.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 1 June 2022
Resolved
For determing the approppirate fire intgerity standards to be applied to boundaries between adjacent spaces, such spaces are classified according to their fire risk as shwon in the categories (1) to (14) below. (3) corridors. passenger and crew corridors. provisions and other stores found to be stored in category (3) spaces on the 3rd deck aft outside of designated storage areas.
SOLAS 01 II-2/26
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 June 2022
Resolution: Items were relocated
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 June 2022
Resolved
Fire protection systems and fire fighting systems and appliances shall be maintainedready for use. Means of escape in the engine room, from the forward enginer's stores found to be blocked. Items were relocated while PSCOs were onboard.
SOLAS 20 II-2/14.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 June 2022
Resolution: Items were relocated while PSCOs were onboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 June 2022
Resolved
Fire protection systems and fire fighting systems and appliances shall be maintained ready for use.Unapproved ducting material was run from the grease trap in the garbage room and vented to the surrounding atmosphere. Venting was removed while PSCOs were onboard.
SOLAS 20 II-2/14.1.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 1 June 2022
Resolution: Venting was removed while PSCOs were onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 June 2022
Resolved
Additionally, in interior locations in passenger sips carrying more than 36 passengers, fire hoses shall be connected to the hydrants at all times. During the fire drill, PSCO observed fire hoses disconnected in the engine room just inside of the engine room workshop. Hoses were connected in the presence of PSCOs.
SOLAS 01 II-2/4.7
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 1 June 2022
Resolution: Hoses were connected in the presence of PSCOs.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 12 December 2021
Resolved
... all openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fire as the divisions which they are fitted. PSCOs identified multiple double-leaf and sliding A-60 doors as well as other lessor rating fire doors not closing in sequential order or closing fully when released making them unable to meet the division rating to which they are fitted.
SOLAS 01 II-2/30.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 December 2021
Resolved
Indication shall be provided at the fire door indicator panel in the continuously manned central control station whether each of the remote-released doors are closed. Several A-Class double leaf doors showed they were closed when only one leaf of the door was closed or when they were closed out of sequence.
SOLAS 01 II-2/30.4.6
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 12 December 2021
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Forward STBD side life raft launching davit's break cable snapped during deployment of raft.
SOLAS 20 III/20
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2021
Resolution: Deficiency rectified prior to PSCOs leaving vessel.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 December 2021
Resolved
Any required fixed fire detection and fire alarm system with manually operated call points shall be capable of immediate operation at all times. PSCOs found five smoke detectors in SPA covered with tape inhibiting its ability to function as designed.
SOLAS 01 II-2/13.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2021
Resolution: 10 c
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 December 2021
Resolved
A door designed to reopen upon contacting an object in its path shall reopen not more than 1 m from the point of contact. The vessel had several sliding fire screen doors which were not reopening when contacting an object in it's path.
SOLAS 01 II-2/30.4.11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 December 2021
Resolved
Each section of sprinklers shall be capable of being isolated by one stop valve only... Means shall be provided to prevent the operation of the stop valves by any unauthorized person. Section valves S12/S13 are located in an unsecured room, accessible to the public with no means to prevent operation by unauthorized persons.
SOLAS 01 II-2/12.2.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2021
Resolved 14 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 6 May 2019
Resolved
The #8 lifeboat has a hole in the stbd bow at its waterline. 74 SOLAS (09 Cons. Ed.) Ch. III Reg. 20.2 Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 May 2019
Resolved 6 May 2019
Resolution: Class was onboard and verified temporary repairs until permanent repairs could be made at homeport.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 6 May 2019
Resolved
02 of the limitor switches on the davit of the #8 lifeboat were inoperable.
74 SOLAS (09 Cons. Ed.) Ch. III Reg. 20.2 Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 6 May 2019
Resolved 6 May 2019
Resolution: Vessel replaced both switches.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 6 May 2019
Resolved
The breakleveler pulley on the #2 liferaft davit (port side) is broken.
74 SOLAS (09 Cons. Ed.) Ch. III Reg. 20.2 Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 6 May 2019
Resolved 6 May 2019
Resolution: Vessel replaced broken pulley.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 May 2019
Resolved
Multiple fire doors have wasted frames on deck 06 near evacuation stations.
74 SOLAS (09 Cons. Ed.) Ch. II-2 Reg. 9.2.2.3.1 In addition to complying with the specific provisions for fire integrity of bulkheads and decks of passenger ships, the minimum fire integrity of all bulkheads and decks shall be as prescribed in the tables as with (4) evacuation stations and external escape routes.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 May 2019
Resolved 7 May 2019
Resolution: Class report submitted (attached) Rectify during next dry dock
Fire Fighting › Means of Escape › Emergency Lighting
Issued 5 January 2018
Resolved
0799 - Means of Escape shall be marked by lighting or photo luminescent strip indicators at all point of escape routes. Low location lighting in the following areas is extinguished: Staircase 2A between deck 4 and 5, FWD passenger stairwell deck 4. 2001 Cons. II-2/Reg. 28.1.10 50ac
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 4 May 2018
Resolution: Received class documentation
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 5 January 2018
Resolved
0725 - Any required automatic sprinkler shall be capable of immediate operation at all times and no action by the crew shall be necessary to set it in operation. Four sprinkler heads missing liquid inside glass bulb and cannot release at designed temperature located in main galley. 2001 Cons. II-2 Reg. 12.1.1 10c
Action required: 705 - Other - as specified
Resolved 5 January 2018
Resolution: Sprinkler heads replaced with designated matching bulbs during inspection.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 5 January 2018
Resolved
0750 - The construction of all doors and door frames in "A" class divisions shall provide resistance to fire as well as the passage of smoke and flame. Door 05.04.54 will not close. 2001 Cons. II-2 Reg. 30.1 50ac.
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 4 May 2018
Resolution: Received class documentation
Fire Fighting › Means of Escape › Blocked
Issued 5 January 2018
Resolved
0999 - Above the bulkhead deck there shall be at least two means of escape from each MVZ or similar restricted space or group of spaces at least one of which shall give access to a stairway forming a vertical escape. Secondary means of escape not provided for crew mess egress deck 4. 2001 Cons. II-2 Reg. 28.2
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 4 May 2018
Resolution: Received class documentation
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 5 January 2018
Resolved
0915 Illustrations and instructions in appropriate language shall be posted and be conspicuously displyed at muster stations. None of the muster station locations contain any illustrations or instructions. SOLAS (2014 Cons.) III/8.4 50ac
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 4 May 2018
Resolution: Received pictures of posted instructions from Staff Captain/Agent
Personnel › Training › Familiarization Training
Issued 11 January 2017
Resolved
0299 - Crew other - Every crewmember with assigned emergency duties shall be familiar with these duties before the voyage begins. Crewmembers assigned to galley units were not familiar with fire fighting appliances in their workspaces. 74SOLAS(14 con.)III/19.2.1 - 10c
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 11 January 2017
Resolution: The crewmembers received additional training on fire fighting appliances within their workspaces.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 11 January 2017
Resolved
0750 - Fire Prevention - All waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. Waste receptables located in broadcast room, deck 5, officers' mess and upholstery shop on deck 4 have combustible receptables. 74SOLAS(2001 con.)II-2/18.5 - 16ac
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 26 March 2017
Resolution: Vessel received statement from class and PSCO verified waste receptacle was replaced with metal container.
Fire Fighting › Means of Escape › Stairways
Issued 11 January 2017
Resolved
0960 - Means of Escape - Stairways shall be arranged to provide ready means of escape to the lifeboat and liferaft embarkation deck from all passenger and crew spaces. Broadcast room directly escapes into the theater. This is a room-in-room configuration as per MSC guidelines SOLAS-25. 74SOLAS(2001 con.)II-2/28.1 - 16ac
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 26 March 2017
Resolution: Vessel received class report and PSCO verified tables and chairs were not present in the stairway.
Fire Fighting › Means of Escape › Stairways
Issued 11 January 2017
Resolved
0960 - Means of Escape - Stairway enclosures shall have direct access to the corridors & be of a sufficient area to prevent congestion. Aft passenger stairwell on deck 5 has large lector & numerous small tables that aren't allowed within perimeter of stairway landing. 74SOLAS(2001 con.)II-2/29.2 - 16ac
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 26 March 2017
Resolution: Vessel received class report and PSCO verified tables and chairs were not present in the stairway.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 11 January 2017
Resolved
0750 - Fire Prevention - Auxiliary machinery spaces having little or no fire risk, storage of combustibles is prohibited. Technical locker located port side deck 5, door #020512 has combustible material stowed inside. 74SOLAS (2001 con.)II-2/26.2.2(10) - 10c
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 11 January 2017
Resolution: The combustible material was removed from the locker.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 11 January 2017
Resolved
0799 - Fire Fighting Appliances other - Fire doors in main vertical zones bulkheads shall for sliding fire door be of no less than 0.1 m/s with the ship in the upright position. sliding fire door #02-08-10 on deck 8 rate of closure was faster than min required time. Hindged & sliding doors: 02-04-10, 05-05-36, 05-05-35, 05-06-36 & 05-04-09. 74SOLAS(2001 con.)II-2/30.4.2 - 16ac
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 26 March 2017
Resolution: Vessel received class report and PSCO verified all doors operated as required.
Engineering › Electric Propulsion System › Feeder Circuitry
Issued 24 July 2016
Resolved
Starboard azipod power slip ring damage causing failure of one half motor and engine fault alarm causing failure of the other.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 July 2016
Resolved 25 July 2016
Resolution: Vessel replaced power slip ring and fork, and reset heating element and fan. All sat.