ST PETER

ST PETER is a 1999 passenger vessel (inspected). The Coast Guard has recorded 102 inspections since 1999, most recently in April 2026, along with 148 deficiencies, 2 operational controls and 12 casualty investigations between 2005 and 2018.

Records from 1999 to 2026. Most recent: inspection, 30 April 2026.

Built
1999
Last inspected
30 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ4476
491942
Flag
UNITED STATES
367117510
Maury page id
psix-491942

Inspections, by type

…with no type recorded11
Years with a record 26 calendar years (1999–2026)
The 102 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)78.5 ft × 28.5 ft × 8.3 ft
Registered tonnagegross 91 / net 73
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALLEN MARINE INC · SITKA, AK, UNITED STATES · built 1999
Hull materialAluminum
PropulsionJet Drive
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portSITKA, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 2 February 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it91 - Simplified, Gross Ton
73 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCZ4476MMSI 367117510 · active · compulsorily equipped · granted 5 June 2019, expires 11 August 2029
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEVEN SEAS MARINER Passenger (Inspected) · MISLE 22623 · 4 July 2009 · activity 3526944

Inspection history · 102

30 April 2026 In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8360752
30 January 2026 Examination of Repairs · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8303848
3 October 2025 Internal Structural Exam · COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8244033
6 September 2025 In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8243788
16 July 2025 In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8187597
4 October 2024 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8014549
25 May 2024 Examination of Repairs · In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7919592
20 November 2023 Internal Structural Exam · Plan Review "T" Boat · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7827868
7 November 2023 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7822773
14 September 2023 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7775893
21 August 2023 In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7768206
29 March 2023 Liferaft Servicing
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7663517
24 March 2023 Liferaft Servicing
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7663535
27 February 2023 Deficiency Check · Examination of Repairs
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7642751
21 February 2023 Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7639977
2 February 2023 Liferaft Servicing
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7641617
20 September 2022 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7562815
23 August 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7541561
19 May 2022 Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7457305
31 January 2022 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7387483
17 November 2021 Liferaft Servicing
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7359812
22 September 2021 In-Service Inspection · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7318472
14 June 2021 Deficiency Check · Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7220733
16 June 2020 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6978701
21 January 2020 Drydock Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6893506
4 December 2019 Internal Structural Exam · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6866783
22 October 2019 Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6842209
11 September 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6810691
17 May 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6690098
19 February 2019 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6628563
1 February 2019 Liferaft Servicing
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6620623
27 December 2018 Liferaft Servicing
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6653717
30 November 2018 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6591217
16 November 2018 Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6582372
6 November 2018 In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6576025
28 September 2018 Administrative Inspection · Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6549266
27 July 2018 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6492734
9 July 2018 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6473688
5 July 2018 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6469831
23 June 2018 Damage Survey · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6453331
23 June 2018 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6522044
22 May 2018 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6420852
16 May 2018 Administrative Inspection · Deadweight Survey · Examination of Repairs
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6417890
15 February 2018 Liferaft Servicing
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6355878
24 January 2018 Liferaft Servicing
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6346429
12 January 2018 Hull Examination · Internal Structural Exam · Deficiency Check · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6337345
29 November 2017 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6315830
2 November 2017 DAPI Audit · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6302055
11 October 2017 In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6285953
22 September 2016 Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5998804
8 July 2016 Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5934415
8 July 2016 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6029462
28 January 2016 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5804585
24 November 2015 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5769971
16 October 2015 COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5744544
16 October 2014 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5006659
6 June 2012 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4336557
6 June 2012 Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4336558
4 June 2012 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4333767
4 June 2012 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4335678
13 January 2012 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 4237870
27 September 2011 Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 4155823
6 December 2010 COI Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3906097
9 March 2010 Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3692590
6 July 2009 Examination of Repairs · Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3526285
4 July 2009 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3526944
8 April 2009 Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3448848
1 October 2007 Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3070472
12 April 2007 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2906859
10 April 2007 Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2905480
6 April 2007 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2903216
4 April 2007 Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2901141
27 March 2007 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2896036
9 January 2007 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2852974
7 June 2006 Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 2679058
15 February 2006 Deficiency Check
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 2585948
14 November 2005 COI Inspection · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 2535103
24 October 2005 Damage Survey
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2530816
22 October 2005 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2550292
13 April 2005 Annual Inspection
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 2333455
12 August 2004 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2164380
30 July 2004 Annual Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2150565
5 April 2004 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2038369
12 March 2004 Damage Survey
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2023605
22 December 2003 Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 1968896
14 May 2003 Re-Inspection · Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1793747
4 April 2003 Hull Examination · Internal Structural Exam
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 1769918
7 May 2002 In-Service Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1617689
20 March 2002 MARPOL Annex V Examination · Administrative Inspection · Annual Inspection
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 1493723
16 May 2001 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1064450
7 May 2001 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1063724
4 May 2001 Hull Examination · MARPOL Annex V Examination · Deficiency Check · COI Inspection · Examination of Repairs
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1362282
6 March 2001 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1060792
9 October 2000 Damage Survey
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1418780
7 October 2000 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 93703
31 May 2000 Damage Survey
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1050344
30 April 2000 Damage Survey
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1424955
29 April 2000 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 123479
27 April 2000 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1049263
13 April 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1426365
6 August 1999 Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 775601
8 June 1999 Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1430701

Deficiency record · 148

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 October 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from fire or machinery failure. Port side main engine has a coolant leak. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 October 2025
Resolution: Rectified
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 October 2025 Resolved
(d) Each nozzle must be of corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. A nozzle on a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, must: (1) Be of a type approved in accordance with approval series 162.027; or (2) Be of a type recognized by the Commandant as being equivalent in performance. Vessel had a non-approved fire nozzle installed. 46 CFR 181.320(d)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 3 October 2025
Resolution: Rectified
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 October 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from fire or machinery failure. Boiler space arrangement is not being used as designed. MI unable to observe closed ventilation on the boiler stack, which led to discovery of a missing pipe for boiler exhaust. 46 CFR 182.100
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2024
Resolved 14 November 2024
Resolution: Missing boiler exhaust pipe was reinstalled.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 October 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from fire or machinery failure. Port aft MDE sporadically continues to run for a short period after shutdown. Find cause and conduct repairs to the satisfaction of USCG marine inspector. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2024
Resolved 23 October 2024
Resolution: Shutdown operated as intended in presence of Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 September 2023 Resolved
Fixed gas extinguishing systems: System design and installation must be in accordance with the Marine Design, Installation, Operation, and Maintenance Manual approved for the system by the Commandant. Time delay on the port & stbd fixed CO2 extinguishing system is less than 30 seconds. Per the fire system servicing report, port side time delay is at 27.5 seconds while the stbd side time delay is at 29 seconds. Provide servicing report meeting the 30 seconds standard. 46CFR181.410
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2023
Resolved 4 October 2024
Resolution: Egress drill conducted. Crew was able to escape engine room within 12 seconds.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 September 2023 Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. Battery banks in port and stbd engine room are not secured. Place batteries in designated area/trays and secure via a mechanism that prevents batteries from shifting. 46CFR183.350(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 November 2023
Resolution: Batteries were properly secured.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 September 2023 Resolved
Vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at operating station and the other at the access to the propulsion machinery space. Portable light at the operating station is dead. Replace light or battery. 46CFR183.430
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 November 2023
Resolution: Portable light on bridge was replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 September 2023 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible. Onboard charts are dated from 2021. Provide new or up-to-date charts of operating area. 46CFR184.420i(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 November 2023
Resolution: Vessel updated digital nautical charts.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 September 2023 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems, including the following: Inspection of each inflatable liferaft to determine that it has been serviced as required by § 185.730 of this chapter. No servicing certificate was provided to attending MI. Provide liferaft servicing certificate no latter than 15SEP2023. 46CFR176.808(a)(4)
Action required: 705 - Other - as specified
Resolved 18 September 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 September 2023 Resolved
A vessel with installed toilet facilities must have a marine sanitation device that complies with 33 CFR part 159. On-board sewage tanks are showing signs of being compromised on tank walls and weld seams. Provide satisfactory evidence attesting to tank integrity, or repair/replace tanks to satisfaction of attending MI. To be recified by next dry dock. 46CFR184.704
Action required: 705 - Other - as specified
Resolved 7 November 2023
Resolution: Cleared and added to DDX activity # 7827868 for tracking purposes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 February 2023 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be suitably insulated where necessary to prevent injuries. Properly install missing exhaust lagging on both main diesel engines in the port engine room and the aft main diesel engine in the starboard engine room. 46 CFR 177.970
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2023
Resolution: Maintenance crew replaced all worn or missing lagging with new exhaust lagging - all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 February 2023 Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. Noted the jacket water temperature gauge on the port aft engine is out of commission and does not appear to be reading accurately. 46 CFR 182.410
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2023
Resolution: Maintenance crew verified proper operation of the jacket water temp gauges and tested - all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 February 2023 Resolved
The starboard main diesel engines failed to stop from the bridge or in the engine room. Properly repair main engine shut down switches. All engines must have at least two means for stopping the engine(s) under any operating conditions. The fuel oil shutoff required at the engine by § 182.455(b)(4) will satisfy one means of stopping the engine. 46 CFR 182.200
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2023
Resolution: Maintenance crew replaced a faulty stop controller and tested - all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2022 Resolved
Unsafe practices. (a) At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Sight glass gauge on the starboard fuel tank is leaking diesel fuel from the lower valve assembly. Repair fuel oil leak to the satisfaction of the attending CG Marine Inspector. 46 CFR 176.830
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 27 September 2022
Resolution: Operator replaced the seal and tightened the packing gland on the sight glass valves tested - all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 September 2022 Resolved
Protection against hot piping. Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be suitably insulated where necessary to prevent injuries. The aft main diesel engine dry exhaust piping is missing sections of lagging. Properly repair or replace all missing, worn, or damaged exhaust lagging. 46 CFR 177.970 & 182.430
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 27 September 2022
Resolution: Operator repaired or replaced exhaust lagging in both engine rooms - all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 20 September 2022 Resolved
Watertight bulkheads...The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. The watertight bulkhead between the starboard engine room and starboard jet room bulkhead penetration for the steering system is missing packing material. 46 CFR 179.320(c).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 27 September 2022
Resolution: Operator sealed bulkhead penetration with 5200 marine sealant - all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2022 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE standard J-1942. Marine Inspector observed cotton lined DOT approved air brake hose being utilized in the Port Fuel Void and Port E/R for fuel service. Install SAE J-1942 fuel hoses or install the correct fire sleeve over cotton lined fuel hoses.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 27 September 2022
Resolution: Operator replaced all hoses with SAE J1942 hoses and SAE J1475 fittings.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 20 September 2022 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Marine Inspector observed the Port Fwd engine's belt guard had a broken mounting bracket. Repair mounting bracket to original condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 27 September 2022
Resolution: Operator replaced mounting bracket with a brand new one - all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2022 Resolved
Each lighting fixture and lamp holder must be fixed. Marine inspector observed two lighting fixtures in the port E/R that were not mounted properly or diffuser was not firmly attached. Properly mount fixture and diffuser for lighting fixtures.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 27 September 2022
Resolution: Operator properly mounted the light and replaced the missing diffuser clips - all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 20 September 2022 Resolved
Watertight integrity. (a) A hatch exposed to the weather must be watertight... The flush deck hatch for the starboard jet room does not dog down watertight. Properly repair quick closing hatch cover so it will dog down watertight. 46 CFR 179.360
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 27 September 2022
Resolution: Operator made adjustments to the hatch cover and relocated the captive cable tested - all sat.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 September 2022 Resolved
Each door, hatch or scuttle, used as a means of escape, must be capable of being opened by one person, from either side. The Marine Inspector observed the port fwd door on the main deck stuck and difficult to open. Repair door to original condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 27 September 2022
Resolution: Operator adjusted the door and closure mechanisms tested - all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 June 2021 Resolved
Vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Bilge suction pipe between manifold and bilge pump was holed multiple times. Repair/renew bilge pipe to original condition.
Action required: 30 - Ship detained
Resolved 23 July 2021
Resolution: Wasted bilge pipe was replaced with new bilge pipe between the manifold and bilge pump.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 June 2021 Resolved
When repairs are made during an emergency, the owner, managing operator or master shall notify the OCMI as soon as practicle after such repairs are made. Electrical tape was used as a temporary repair to stop the leak on the above deficiency and the OCMI was not notified.
Action required: 30 - Ship detained
Resolved 23 July 2021
Resolution: Discussed reporting procedures with vessel management and crew. Management implementing new fleetwide electronic SMS to help track and report damaged equipment, operations and training.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 June 2021 Resolved
The following spaces must be equipped with a fire detecting system of an approved type: (i) A space containing propulsion machinery. The fire detection system did not operate when tested. Repair/renew to original condition.
Action required: 30 - Ship detained
Resolved 23 July 2021
Resolution: All fire detection systems tested and operated correctly.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 June 2021 Resolved
On a vessel of more than 65 feet in length the minimum capacity of the fire pump must be 50 gpm at a pressure not less than 60 psi at the pump outlet. The pump outlet must be fitted with a gauge. Gauge was not operational and pressure could not be determined. Renew gauge and prove proper operation to attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2021
Resolution: New gauge installed at fire pump, operating pressure at 70 PSI. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 June 2021 Resolved
An adult lifejacket must be provided for each person carried on board a vessel. More than 35 life jackets were in unserviceable condition. Provide serviceable life jackets for all passengers on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2021
Resolution: New lifejackets were placed on vessel, unserviceable lifejackets removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 January 2020 Resolved
Reach rod for port forepeak bilge piping valve attached with plastic tie wraps. Make proper attachment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2020
Resolved 16 June 2020
Resolution: Satisfactorily witnessed bilge pumping from port fore-peak.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 December 2019 Resolved
Upper deck aft cabin door on the port side automatic door closer is bent and blocks door from being opened. Make permanent repairs to ensure the door cannot be blocked closed thus blocking the means of escape.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2020
Resolution: Door closure properly fixed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 December 2019 Resolved
#1 MDE has an excessive oil leak on the aft inboard side. Make permanent repairs to stop leakage.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 December 2019 Resolved
#1 MDE electrical harness is currently suspended from overhead with a piece of rope. Make permanent repairs to properly secure wiring harness.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2020
Resolution: Electrical harness properly routed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 December 2019 Resolved
#3 MDE missing a bold on a bracket on the forward inboard side of engine. Make permanent repairs to secure bracket.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2020
Resolution: Bolt replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 December 2019 Resolved
Engine room light fixture missing light bulbs and cover above #4 MDE. Replace bulbs and cover or remvoe light fixture from engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2020
Resolution: Cover replaced. Light bulbs left out due to light not needed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 October 2019 Resolved
Replaced both port and starboard time delay bottles. Both trips at around 5-8 seconds on a 30 second bottle
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 October 2019 Resolved
Install CO2 warning labels on both port and starboard engine room hatches.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2020
Resolution: Placards installed on both doors.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 October 2019 Resolved
Install simple operation instructions at or near pull station on both port and starboard sides
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2020
Resolution: Instructions posted.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 22 October 2019 Resolved
Prove port fwd ventilations closers close all the way.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2019
Resolution: Vessel repaired port fwd ventilations closer, tested all sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 October 2019 Resolved
Install a fixed gas fire extinguishing system, in compliance with §181.410 for the fuel fire boiler space prior to using the boiler.
Action required: 705 - Other - as specified
Resolved 12 September 2022
Resolution: Operator installed a pre engineered fire boy system in the furnace space, tested shut down and alarms, remote fuel and air supply vent closure - all sat. Tested stand alone heat detection system installed in the space - all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 September 2019 Resolved
The Generator has a small raw water leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 September 2019 Resolved
The vessel's batteries need to be placed in a non conductive tray.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 September 2019 Resolved
The starboard aft main engine has an oil leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 September 2019 Resolved
The starboard aft engine has a small jacket water leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 September 2019 Resolved
Exhaust lagging needs to be adjusted on the rear starboard main engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2019
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 September 2019 Resolved
There is excessive oil in the bilges.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 September 2018 Resolved
Repair fuel oil leak on generator first stage fuel oil filter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2018
Resolution: Vessel replaced oil ring on filter, tested all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 September 2018 Resolved
Replace all chaffed fuel oil hose on starboard side fwd. engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2018
Resolution: Vessel has replaced chaffed fuel hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 September 2018 Resolved
Find and repair exhaust cooling leak on port aft engine
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 November 2018
Resolution: Vessel has fixed cooling leak.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2018 Resolved
Remove dead end wires in both jet rooms and in the port Side aft engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 November 2018
Resolution: Vessel has removed all deadend wires
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 September 2018 Resolved
Repair exhaust leak on both port engines
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 November 2018
Resolution: Vessel has repaired exhuast leaks
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 28 September 2018 Resolved
Reattach port side engine room hatch gasket
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 November 2018
Resolution: Vessel has repaired gasket
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 September 2018 Resolved
Update vessel’s FCC Station License to display the correct Vessel’s name
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 May 2019
Resolution: Vessel has RCVD a update FCC Station License.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 September 2018 Resolved
Reinstall port inboard jet bucket prior to 01APR19
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 19 February 2019
Resolution: Verified bucket was installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 September 2018 Resolved
Repair 3 cracked weld in the #1 port void from the transverse frame to the main deck during the next dry dock
Action required: 705 - Other - as specified
Due 31 January 2020
Resolved 19 February 2019
Resolution: Conducted a satisfactory visual examination of picked up fillet welds.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 September 2018 Resolved
Repair 1 cracked weld in the #1 starboard void from the transverse frame to the main deck during the next dry dock
Action required: 705 - Other - as specified
Due 31 January 2020
Resolved 19 February 2019
Resolution: Conducted a satisfactory visual examination of picked up fillet welds.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 September 2018 Resolved
Make repairs to framing and cracked welds in the port side engine room outboard side just fwd. of engine exhaust port by 01APR18
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 19 February 2019
Resolution: Verified affected area was repaired with a 97" x 62" x 3/16" insert and affected frame was cropped and renewed. Conducted a satisfactory vacuum box test and visual exam of inserted plate.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2018 Resolved
Install proper electrical box cover for toilet flush button boxes in all heads
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 November 2018
Resolution: Vessel has install proper electrical box covers
Fire Fighting › Fire Pumps › Power Source
Issued 23 June 2018 Resolved
07113 - A self priming, power driven fire pump must be installed on each vessel and may be driven by a propulsion engine. The vessel's fire pump is powered by the #1 engine, which was rendered inoperable. Restore the #1 engine to operational status and demonstrate the operation of the installed fire pump to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2018
Resolution: Verified the #1 engine and fire pump were operating properly.
Fire Fighting › Fire Pumps › Pressure
Issued 22 May 2018 Resolved
Prove proper operation of the fire pump
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 May 2018
Resolution: Fire pump restored to operation and tested in presence of CG MI.
Construction/Loadline › Hull › Side Shell
Issued 12 January 2018 Resolved
Make permanent repairs to areas of hull plate removed on the STBD aft quarter.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 27 February 2018
Resolution: Verified damaged areas were cropped and renewed.
Construction/Loadline › Hull › Hull Plating
Issued 12 January 2018 Resolved
Repair all structures and bulkhead/side shell penetrations upset to facilitate main engine renewal.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 16 May 2018
Resolution: Witnessed satisfactory vacuum box testing of both port and starboard inserts.
Construction/Loadline › Penetrations › Pipe Flange
Issued 12 January 2018 Resolved
Provide valve on both sides of the fwd bulkhead of the port engine room for non-metallic potable water pipe penetration.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 22 May 2018
Resolution: vessel has installed valve on both sides of the bulkhead
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 November 2017 Resolved
Properly install water light to lifebuoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 November 2017
Resolution: Vessel has properlry attached water light
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 November 2017 Resolved
Fix top deck railing on starboard side aft.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 22 May 2018
Resolution: vessel has repaired hand rail
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 2 November 2017 Resolved
Replace top deck aft portable fire extinguisher
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 November 2017
Resolution: Vessel has installed new portable fire extinguisher.
Fire Fighting › Fire Hoses › Condition
Issued 2 November 2017 Resolved
Replace both fire hoses.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 November 2017
Resolution: Vessel has replaced both fire hoses.
Accommodation/Occupational Safety › Ventilation › General
Issued 2 November 2017 Resolved
Prove proper operation of both port and starboard engine room ventilation fans.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 November 2017
Resolution: Vessel has repaired both engine room ventilation fans
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 2 November 2017 Resolved
Fix engine exhaust leak on port and starboard aft engines and insure proper installation of exhaust lagging on repair.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 November 2017
Resolution: Vessel has fixed engine exhaust leak on port and starboard aft engines and installed exhaust lagging.
Electrical › Electrical Distribution System (service) › Switch
Issued 2 November 2017 Resolved
Prove proper operation of all electrical switches in the port and starboard fiddle
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 29 November 2017
Resolution: vesssel has repaired all electrical switches in the port and starboard fiddle
Stability › Watertight Integrity › Weathertight Enclosure
Issued 2 November 2017 Resolved
Fix watertight gasket on starboard jet room hatch.
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 29 November 2017
Resolution: vessel has fixed watertight gasket on starboard jet room hatch.
Operations/Management › Drills/Instruction › Fire
Issued 2 November 2017 Resolved
Conduct drills with CG inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 22 May 2018
Resolution: Conducted underway drills all sat
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 11 October 2017 Resolved
Ventilation closures released but did not drop to cover intake due to corrosion or lack of lubrication. Demonstrate operation of ventilation closures to the attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 22 May 2018
Resolution: Ventilation covers have been repaired and work properly
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 11 October 2017 Resolved
Engines and power ventilation were not operating at the time of the test. Demonstrate operation of the engine and power ventilation shutdowns to the attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 20 August 2018
Resolution: Witnessed operation of ventilation shutdowns.
Engineering › Diesel Engine (propulsion-reduction gear) › Seal
Issued 8 July 2016 Resolved
Properly repair the port forward MDE that has a major lube oil leak.
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 9 July 2016
Resolution: Company mechanics replaced the leaking lube oil pressure sending unit. Test ran the engine - SAT.
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 28 January 2016 Resolved
Replace inop CO sensors in jet voids. Engine exhaust passes through space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 January 2016
Resolved 28 January 2016
Construction/Loadline › Penetrations › Valve Flange
Issued 28 January 2016 Resolved
Replace plastic through hull fittings with metallic fittings. 46 CFR 182.720(d)(3)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 15 March 2016
Resolution: The plastic through fittings were replaced with metal ones.
Construction/Loadline › Hull › Hull Plating
Issued 28 January 2016 Resolved
Remove sea chest screens on the bottom of the hull and remove marine growth. 46 CFR 182
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 15 March 2016
Resolution: The raw water screens on the hull were cleaned.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 21 October 2015 Resolved
Provide lifesaving servicing reports/certificates.
Action required: 705 - Other - as specified
Due 4 November 2015
Resolved 24 November 2015
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 21 October 2015 Resolved
Service firefighting equipment and provide servicing reports.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2015
Resolved 24 November 2015
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 21 October 2015 Resolved
Make proper Notice to Mariner corrections on applicable navigational charts.
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 5 May 2016
Fire Fighting › Means of Escape › Escape Route Signs
Issued 21 October 2015 Resolved
Properly mark forward port & starboard exits with "EMERGENCY EXIT, KEEP CLEAR".
Action required: 705 - Other - as specified
Due 4 November 2015
Resolved 24 November 2015
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 21 October 2015 Resolved
Replace and install port side, aft fire extinguisher bracket.
Action required: 705 - Other - as specified
Due 4 November 2015
Resolved 24 November 2015
Electrical › Lighting (service) › Switch
Issued 21 October 2015 Resolved
Properly secure light switch in port steering gear space.
Action required: 705 - Other - as specified
Due 4 November 2015
Resolved 24 November 2015
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 October 2015 Resolved
Repair forward port railing from cracks and ensure durability.
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 5 May 2016
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 21 October 2015 Resolved
Remove excessive oil from underneath starboard stern engine.
Action required: 705 - Other - as specified
Due 4 November 2015
Resolved 24 November 2015
Engineering › Non-conventional Propulsion/Steering › Hydraulic Bucket Cylinder (jet)
Issued 4 June 2012 Resolved
2 belts connecting bucket to drive shaft broke while underway. Replace and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 June 2012
Resolution: Belts replaced and tested SAT.
Fire Fighting › Fire Pumps › Arrangement
Issued 6 July 2009 Resolved
Provide suitable fire pump to the vessel prior to resuming regular service. No. 1 forward STBD engine that drives the fire pump is OOC.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2009
Resolved 15 July 2009
Resolution: Witnessed tested, sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 April 2009 Resolved
Provide annual servicing report.
Action required: 705 - Other - as specified
Resolved 24 March 2010
Resolution: Serviced on March 11, 2010.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 1 October 2007 Resolved
Provide PML's on all PFD's prior to operating offshore.
Action required: 705 - Other - as specified
Resolved 24 March 2010
Resolution: Vessel''s route was changed back to L,B,S and no lights are required.
Fire Fighting › Fixed Fire Detection System › Power Supply
Issued 10 April 2007 Resolved
Ensure that fire detection system is electronically supervised.
Due 1 July 2007
Resolved 16 July 2007
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 4 April 2007 Resolved
Demonstrate the proper operation of the port & STBD side engineroom fire detection (smoke/heat) as per CID Memo #2-07. Replace the missing sensor in the port side engineroom.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2007
Resolved 12 April 2007
Resolution: Tested port-side detector with smoke, sat. (Tested starboard-side detector with smoke during annual exam, sat.)
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 4 April 2007 Resolved
Re-label a Ringbouys of the vessel's name & refurnish retro-reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2007
Resolved 12 April 2007
Resolution: Verified that ringbouys were properly labeled.
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 4 April 2007 Resolved
Provide information that the heating furnace is approved for marine use. Test safety shutdowns.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 April 2007
Resolved 9 April 2007
Resolution: It doesn''t need to be labeled "Marine Use." In accordance with 46CFR184.202 it just needs to be suitable for marine use. If designed and installed in accordance with ABYC A-7 or NFPA 302 it complies. This unit complies with ABYC A-7.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 April 2007 Resolved
Refurbish missing eye wash bottles located aft galley port side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 April 2007
Resolved 12 April 2007
Resolution: Verified that two new new eye-wash bottles were installed in galley.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 4 April 2007 Resolved
Secure the second lower microwave oven located in the galley for sea.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 April 2007
Resolved 12 April 2007
Resolution: Verified that both microwaves were lashed down.
Electrical › Lighting (service) › Switch
Issued 4 April 2007 Resolved
Label light switch in a distribution box in the STBD engineroom.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 April 2007
Resolved 12 April 2007
Resolution: Verified that label had been affixed to box.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 4 April 2007 Resolved
Provide missing light lists.
Condition: Unknown
Due 4 April 2007
Resolved 4 April 2007
Resolution: Done, sat.
Navigation › Piloting/Steering › Magnetic Compass
Issued 4 April 2007 Resolved
Make the magnetic compass illuminated as per 46 CFR 184.402(c).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 April 2007
Resolved 12 April 2007
Resolution: Verified compass illumination.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 April 2007 Resolved
Provide a complete first aid kit as per 46 CFR 184.710.
Condition: Improper/Lack of Maintenance
Due 4 April 2007
Resolved 4 April 2007
Resolution: Done, a new one was produced, sat.
Construction/Loadline › Hull › Weld
Issued 21 November 2005 Resolved
In port #2 void on inboard side pickup undercut weld at chine where marked.
Action required: 705 - Other - as specified
Resolved 21 December 2005
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 21 November 2005 Resolved
Provide proper gooseneck vent up through the deck for the forward auxiliary MSD tank and remove hose that runs to centerline and down to valve.
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 15 February 2006
Resolution: Deleted requirement on appeal This is an auxiliary tank that can only be pumped to manually. It also has electronic level alarm on the bridge with 1/4, 1/2, 3/4, & full readings. The full level is set at approx. 80-90% to prevent overflow through vent.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 November 2005 Resolved
In port fuel void, provide "fireblock" where the pump wires penetrate both fore and aft transverse bulkheads.
Action required: 705 - Other - as specified
Resolved 21 December 2005
Construction/Loadline › Hull › Bottom Plating
Issued 21 November 2005 Resolved
In the tunnel beneath the MSD tank and just forward, clean for inspection the plate that appears to be severely pitted for evaluation for renewal.
Action required: 705 - Other - as specified
Resolved 21 December 2005
Resolution: Area may possibly require renewal at next drydock exam.
Construction/Loadline › Structures › Deck Plating
Issued 21 November 2005 Resolved
In both jet rooms, provide "fireblock" where the wire bundles penetrate the deck without support and enclosure.
Action required: 705 - Other - as specified
Resolved 21 December 2005
Construction/Loadline › Structures › Door
Issued 14 November 2005 Resolved
Remove barrel bolt locks from exterior engine room doors and the aft stbd main cabin door.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 21 November 2005
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 14 November 2005 Resolved
Prove proper operation of the oil fired HVAC heater.
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 15 February 2006
Resolution: Oil fired heater was replaced with a brand new unit.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 November 2005 Resolved
Replace missing cover on relay switch next to battery chargers in port engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 December 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 14 November 2005 Resolved
Prove proper operation of port forward main diesel engine. Erratic RPM and error code "64 speed circuit".
Action required: 705 - Other - as specified
Resolved 21 December 2005
Construction/Loadline › Structures › End Bulkhead
Issued 14 November 2005 Resolved
Seal weld or provide service plugs for holes drilled in engine room bulkhead entrance vestibule at base - possibly for draining water.
Action required: 705 - Other - as specified
Resolved 21 November 2005
Resolution: Removeable bolts installed to allow removal for draining water
Construction/Loadline › Structures › Manhole
Issued 14 November 2005 Resolved
Near forward engine room hatches provide signs saying "Emergency Escape Keep Clear"
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 15 February 2006
Resolution: Signs on order and due to arrive today/tomorrow.
Construction/Loadline › Structures › Deck Plating
Issued 14 November 2005 Resolved
Seal holes in main deck floor where seats were reconfigured and old mounting holes remain.
Action required: 705 - Other - as specified
Resolved 21 December 2005
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 24 October 2005 Resolved
Replace missing IBA's with Coast Guard approved IBA's.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 November 2005
Resolved 3 November 2005
Resolution: Three 50 man Coast Guard approved Elliot IBA''s were properly installed, sat.
Documentation › Certificates/Documents › FCC SSL
Issued 30 July 2004 Resolved
Place original FCC Ship to Ship certificate on board vsl.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2004
Resolved 12 August 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 July 2004 Resolved
Missing cover on ventilation fan in galley space.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2004
Resolved 12 August 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 30 July 2004 Resolved
Raw water hose for port aft engine showed signs of deterioration and needs to be replaced.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2004
Resolved 12 August 2004
Communications › Radio Communications › EPIRB
Issued 30 July 2004 Resolved
Float free release for EPIRB expired. Replace with new hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 30 July 2004
Resolution: Replaced hydrostatic release. Sat.
Lifesaving › Lifebuoys › Serviceable
Issued 30 July 2004 Resolved
Grab lines on lifering on upper deck aft portion of vsl were deteriorated. Replace with new approved lifering.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2004
Resolved 30 July 2004
Resolution: Old lifering taken out of service and replaced with new lifering. Sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marine Type Label
Issued 30 July 2004 Resolved
Noted one fire extinguisher was missing the inspection label. Verbally required master to replace label. Extinguisher appeared to be in good condition and gauge indicated good pressure.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2004
Resolved 12 August 2004
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 30 July 2004 Resolved
Electrical outlet above beverage counter missing cover. Replace appropriate cover.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 August 2004
Resolved 30 July 2004
Resolution: Cover placed on outlet. Sat.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 30 July 2004 Resolved
Missing one required lifejacket.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2004
Resolved 30 July 2004
Resolution: Two additional lifjackets were placed on the vsl to meet requirements of COI. Sat.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 30 July 2004 Resolved
Bare wire on Flo-jet pump in starboard engine room. Flo-jet pump is for the head. Reconnect wires.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2004
Resolved 30 July 2004
Resolution: Wires reconnected. Sat.
Construction/Loadline › Hull
Issued 12 March 2004 Resolved
Crop and renew damage IWO port side rub rails prior to the carriage of passengers. Three areas IWO rub rail in voids 2, 3, and port side engine space. LEGACY COMPONENT DESC: Sheerstrake
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 May 2004
Resolved 5 April 2004
Resolution: Done, sat.
Accommodation/Occupational Safety › Medical/First Aid
Issued 14 May 2003 Resolved
Upgrade first aid kit IAW 46 CFR 160.054-4(B), replace all expired items. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 28 May 2003
Resolved 14 May 2003
Resolution: Changed all expired items...e.g. aspirin.
Engineering › Lubricating Oil Storage/Transfer System
Issued 14 May 2003 Resolved
Removed 2-5 gallon lubricating oil store under stairs up to second deck. LEGACY COMPONENT DESC: Flammable Storage space
Condition: Unknown
Due 28 May 2003
Resolved 14 May 2003
Resolution: Removed & place on dock.
Accommodation/Occupational Safety › Cooking Systems
Issued 14 May 2003 Resolved
Secure for sea the microwave, fridge, & refrigerator located in the kitchen area. LEGACY COMPONENT DESC: Microwave, fridge, & refrigerator
Condition: Improper Installation
Due 28 May 2003
Resolved 14 May 2003
Resolution: Secured
Construction/Loadline › Hull
Issued 4 April 2003 Resolved
Crop and renew section of the starboard hull outboard where damaged in a grounding in April 29, 2000. LEGACY COMPONENT DESC: Bottom Plating
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2003
Resolved 15 January 2004
Resolution: Sections satisfactorily renewed. Extended compliance date, vessel was out of service for season and until repairs were completed.
Construction/Loadline › Hull
Issued 4 April 2003 Resolved
Crop and renew the frames located in the stbd engine room where two are buckled from grounding April 29, 2000. LEGACY COMPONENT DESC: Transverse Frame
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2003
Resolved 15 January 2004
Resolution: Sections satisfactorily renewed. Extended compliance date, vessel was out of service for season and until repairs were completed.
Communications › Alarms/Indicators
Issued 4 April 2003 Resolved
Replace missing Carbon Monoxide Sensor in Port Engine Room or remove associated electrical box and wiring. LEGACY COMPONENT DESC: Carbon Monoxide Sensor
Condition: Damaged By Earlier Event
Due 7 May 2003
Resolved 14 May 2003
Resolution: Check ... one installed.
Electrical › Lighting (service)
Issued 4 April 2003 Resolved
Replace missing cover to florescent light in port side fuel void. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Damaged By Earlier Event
Due 7 May 2003
Resolved 14 May 2003
Resolution: Replaced with new.
Engineering › Fuel Oil Storage/Transfer System
Issued 4 April 2003 Resolved
Repair minor leaks above fuel tanks in both Port and Stbd Fuel Tank voids LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2003
Resolved 8 April 2003
Resolution: Minor leaks corrected
Stability › Watertight Integrity
Issued 4 April 2003 Resolved
Provide retention wire or chain for aft main deck watertight hatches. LEGACY COMPONENT DESC: Water tight hatch retention wires
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2003
Resolved 14 May 2003
Resolution: Installed
Construction/Loadline › Hull
Issued 4 April 2003 Resolved
Crop and renew hull plate where inset located on inboard side of stbd hull forward at wind and water line. LEGACY COMPONENT DESC: Bottom Plating
Action required: 705 - Other - as specified
Due 31 October 2003
Resolved 8 April 2003
Resolution: New plate properly inserted.
Construction/Loadline › Penetrations
Issued 4 April 2003 Resolved
Renew port main deck anchor chain access plate and reseat/reseal where improperly installed. LEGACY COMPONENT DESC: Port main deck anchor chain access plate
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 May 2003
Resolved 8 April 2003
Resolution: Reinstalled with backing plate.
Construction/Loadline › Penetrations
Issued 4 April 2003 Resolved
Re-weld at main deck, vents where lack of weld penetration is evident from below deck, approx 5 affected vents, one of which daylight may be seen. LEGACY COMPONENT DESC: Vents for void spaces
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 May 2003
Resolved 8 April 2003
Resolution: Welds completed
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 20 March 2002 Resolved
The hoses connecting the CO2 bottles to the distribution piping were replaced due to corrosion of the fittings. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 20 March 2002
Resolved 20 March 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 20 March 2002 Resolved
Proper instructions for operating the fixed CO2 system were missing at the remote operating stations, at the CO2 bottles and in the machinery space were the CO2 is discharged. They were replaced during the inspection.
Condition: Unknown
Due 20 March 2002
Resolved 20 March 2002
Lifesaving
Issued 7 May 2001 Resolved
Provide guards over exposed defroster motor blades in unsecured storage space fwd of main passenger cabin prior to carrying passengers.
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Lifesaving
Issued 4 May 2001 Resolved
Renew vessel name markings on the Ring Life Buoys. 46 CFR 185.604.
Condition: Unknown
Due 4 May 2001
Resolved 4 May 2001
Accommodation/Occupational Safety
Issued 4 May 2001 Resolved
Passengers are not allowed on the upper deck until the broken wire rail courses are replaced and loose wire rail courses are tightened. 46 CFR 177.900.
Condition: Unknown
Due 4 May 2001
Resolved 4 May 2001
Documentation
Issued 4 May 2001 Resolved
Obtain replacement certificate for the lost FCC Safety Radiotelophony Certificate.
Condition: Unknown
Due 4 May 2001
Resolved 4 May 2001
Construction/Loadline
Issued 9 October 2000 Resolved
MAKE PERMANENT REPAIRS TO PORT HULL FROM VESSEL GROUNDING. REPAIRS INCLUDE,BUT ARE NOT LIMITED TO BOTTOM PLATE, DEEP FRAMES, SIDE SHELL, PORT O/B JET_x001C_INTAKE GRATE, AND TRIM TAB. ALL REPAIRS TO BE MADE TO SATISFACTION OF ATTENDING MARINE INSPECTOR AND PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 9 October 2000
Resolved 9 October 2000
Construction/Loadline
Issued 9 October 2000 Resolved
MAKE TEMPORARY REPAIRS TO PORT HULL AS NEEDED TO MINIMIZE WATER INGRESS DURING TRANSIT TO SITKA IN PORT F/O SPACE TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 9 October 2000
Resolved 9 October 2000
Construction/Loadline
Issued 13 April 2000 Resolved
Provide captive devices for hatch covers of all watertight hatches on the weather deck in accordance with 46 CFR 171.124.
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Lifesaving
Issued 13 April 2000 Resolved
Prior to operations with passengers, conduct underway test and drills to the satisfaction of an attending Coast Guard marine inspector in accordancewith 46 CFR 185.420, 185.520, and 185.524.
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Documentation
Issued 13 April 2000 Resolved
Post Stability letter near operating station in accordance with 46 CFR 176.306.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Navigation
Issued 13 April 2000 Resolved
Provide ships bell in accordance with navigation rules.
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Engineering
Issued 8 June 1999 Resolved
Provide insulation at exhaust connection of both engines - per 46CFR177.970
Condition: Unknown
Due 8 June 1999
Resolved 8 June 1999
Documentation
Issued 8 June 1999 Resolved
Provide original document on board prior to operation with passengers or NLT 08JUL99 - unless verified and allowed by MSO Anchorage.
Condition: Unknown
Due 8 June 1999
Resolved 8 June 1999
Documentation
Issued 8 June 1999 Resolved
Provide MSD Sitka updated plans for electrical system, propulsion, and hullpenetrations.
Condition: Unknown
Due 8 June 1999
Resolved 8 June 1999
Electrical
Issued 8 June 1999 Resolved
Provide a guard for E/R exhaust fans on E/R side - per 46CFR177.960.
Condition: Unknown
Due 8 June 1999
Resolved 8 June 1999

Casualty record · 12

22 October 2005Routine · role: Involved in a Marine Casualty · activity 2550292
4 July 2009Routine · role: Involved in a Marine Casualty · activity 3526944
12 May 2010Routine · role: Involved in a Marine Casualty · activity 3749393
2 August 2010Routine · role: Involved in a Marine Casualty · activity 3826314
4 June 2012Routine · role: Involved in a Marine Casualty · activity 4333767
6 June 2012Routine · role: Involved in a Marine Casualty · activity 4336557
14 August 2012Routine · role: Involved in a Marine Casualty · activity 4420224
12 June 2013Routine · role: Involved in a Marine Casualty · activity 4620317
9 August 2013Routine · role: Involved in a Marine Casualty · activity 4683273
18 September 2013Routine · role: Involved in a Marine Casualty · activity 4718958
8 July 2016Routine · role: Involved in a Marine Casualty · activity 6029462
23 June 2018Routine · role: Involved in a Marine Casualty · activity 6522044
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

CAPE AIALIK (2005–2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.