MAURY USCG vessel records Sign in
← All vessels

OCEAN COUNTESS

OCEAN COUNTESS is a 1975 passenger vessel (inspected). The Coast Guard has recorded 88 inspections since 1985, most recently in November 1996, along with 96 deficiencies.

Records from 1985 to 1996. Most recent: inspection, 30 November 1996.

Built
1975
Last inspected
30 November 1996
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7358561 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
226705
Flag
UNITED KINGDOM
—
Maury page id
psix-226705

Inspections, by type

…with no type recorded44
Years with a record 12 calendar years (1985–1996)
The 88 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it10140 - Regulatory (Subpart C or D), Net Ton
3230 - Dead Weight, Ton
17495 - Convention (Subpart B), Gross Ton
17593 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MANUEL HENRIQUEZ Passenger (Inspected) · MISLE 48400 · 10 August 1996 · activity 74715CUDA Commercial Fishing Vessel · MISLE 43768 · 11 September 1993 · activity 496661

Inspection history · 88

30 November 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1094239
13 September 1996 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 395213
13 September 1996 Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1392539
10 August 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 74715
6 July 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1447598
21 June 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1081911
15 June 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 392338
14 June 1996 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 392262
14 June 1996 Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1433059
26 March 1996 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 646886
15 March 1996 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 388798
15 March 1996 Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1414588
6 February 1996 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 67445
5 January 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 878778
15 December 1995 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 385957
15 December 1995 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1353836
21 October 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 871316
29 September 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 383255
29 September 1995 Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1357331
24 June 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 379796
24 June 1995 Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1439630
29 April 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 866736
10 April 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 842744
25 March 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 376668
25 March 1995 Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1405670
16 December 1994 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1358627
23 September 1994 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 370246
23 September 1994 Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1396180
24 June 1994 Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1394141
26 March 1994 Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1367013
11 March 1994 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 365091
17 December 1993 Control Verification · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1414225
11 September 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 118476
11 September 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 496661
3 September 1993 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 360714
3 September 1993 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1452976
28 June 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 46179
20 June 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 156078
11 June 1993 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 827521
11 June 1993 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1435386
17 April 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 70589
26 March 1993 Control Verification · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1354284
11 December 1992 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 355081
11 December 1992 Certificate of Compliance · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1450741
25 October 1992 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 152691
25 September 1992 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 353553
25 September 1992 Control Verification · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1387272
19 July 1992 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 112296
13 July 1992 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 7176
19 June 1992 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1470638
20 March 1992 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1015035
25 February 1992 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 48003
25 February 1992 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 83901
20 December 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 348067
20 December 1991 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 955410
20 September 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 346506
20 September 1991 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 944099
21 June 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 344624
21 June 1991 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1221756
22 March 1991 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1236407
21 December 1990 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1224684
22 June 1990 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 904454
30 March 1990 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 903520
29 December 1989 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 334526
29 December 1989 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 918826
29 December 1989 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1216116
21 December 1989 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 909253
8 September 1989 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1345340
16 June 1989 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1352463
17 March 1989 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 894516
9 December 1988 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 897872
9 December 1988 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 898338
28 October 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 326847
28 October 1988 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 892021
28 October 1988 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1204616
15 July 1988 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1340212
7 April 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1350650
26 December 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 322828
19 December 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 322817
19 December 1987 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1339649
11 September 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1003674
19 June 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1313788
20 March 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1325565
20 December 1986 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1007332
31 October 1986 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1321830
18 April 1986 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 999247
11 October 1985 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 989684
5 July 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1291825

Deficiency record · 96

Fire Fighting
Issued 13 September 1996 Resolved
REPAIR FIRESCREEN DOOR 4-18 PRIOR TO DEPARTURE.
Condition: Unknown
Due 13 September 1996
Resolved 5 October 1996
Accommodation/Occupational Safety
Issued 13 September 1996 Resolved
RENEW SEWAGE PIPING TO THE SATISFACTION OF THE CLASS SOCIETY
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Construction/Loadline
Issued 13 September 1996 Resolved
PROVIDE CLASS SOCIETY REPORT ADDRESSING THE INSETS FORWARD STARBOARD SIDE ABOVE THE WATERLINE.
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Engineering
Issued 14 June 1996 Resolved
Properly repair leaking injector and associated box fitting on the starboard inboard main deisel engine located on the starboard side of the MDE.
Condition: Unknown
Due 15 June 1996
Resolved 17 June 1996
Engineering
Issued 14 June 1996 Resolved
Properly repair valve to the laundry steam supply in the boiler plant space.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Fire Fighting
Issued 14 June 1996 Resolved
Perform a fire drill to the satisfaction of the attending marine inspector prior to sailing from St. Thomas, USVI on 14JUN96.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Fire Fighting
Issued 14 June 1996 Resolved
Make repairs to fire screen doors BO.08 and BO.09. Survey remaining doors for proper operation.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Construction/Loadline
Issued 14 June 1996 Resolved
Perform closing of all water tight doors to close in less than 60 seconds in the presence of a Coast Guard inspector.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Construction/Loadline
Issued 14 June 1996 Resolved
Provide class society report or make proper repairs to overboard fittings in way of the port stern quarter as pointed out to the Chief Engineer.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Lifesaving
Issued 14 June 1996 Resolved
Properly clean and remove excess leaking and waste oil from the engine room, the generator room, and the deck plates throughout the engine room.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Fire Fighting
Issued 14 June 1996 Resolved
Connect all interior fire hoses to fire hydrants and connect all nozzles tofire hoses prior to sailing on 14JUN96.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Lifesaving
Issued 15 December 1995 Resolved
REMOVE AND CLEAN OIL FROM THE DECK IN THE SEWAGE TREATMENT VOID SPACE.
Condition: Unknown
Due 15 December 1995
Resolved 15 December 1995
Electrical
Issued 15 December 1995 Resolved
PROPERLY REPAIR WATER LEAK IN THE EMERGENCY DIESEL GENERATOR ENGINE.
Condition: Unknown
Due 15 December 1995
Resolved 15 December 1995
Fire Fighting
Issued 29 September 1995 Resolved
CORRECT FIRE SAFETY PLAN SHOWING LOCATION OF PAINT LOCKER, TO BE COMPLETED TO THE SATISFACTION OF CLASS SOCIETY
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Construction/Loadline
Issued 29 September 1995 Resolved
INSTALL DECK HATCH COVER IN DECK STORES FWD, TO THE SATISFACTION OF CLASS SOCIETY
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Fire Fighting
Issued 29 September 1995 Resolved
INSURE PROPER OPERATION OF FIRESTATION 223 DOOR
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Fire Fighting
Issued 29 September 1995 Resolved
PROPERLLY STOW ALL FIRE HOSES ON #2 DECK.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Fire Fighting
Issued 29 September 1995 Resolved
INSURE PROPER OPERATION OF FIRE SCREEN DOOR 2.12
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Fire Fighting
Issued 29 September 1995 Resolved
INSURE PROPER OPERATION OF FIRE SCREEN DOOR 2.02
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Fire Fighting
Issued 29 September 1995 Resolved
INSURE PROPER OPERATION OF FIRE SCREEN DOOR 2.37
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Fire Fighting
Issued 29 September 1995 Resolved
INSURE PROPER OPERATION OF FIRE SCREEN DOOR 2.24
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Accommodation/Occupational Safety
Issued 29 September 1995 Resolved
REMOVE ALL ITMES STOWED IN PASSAGEWAY TO CREW CABINS 202,204 AND 206
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Fire Fighting
Issued 29 September 1995 Resolved
INSURE PROPER OPERATION OF FIRE SCREEN DOOR 4.23
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Lifesaving
Issued 29 September 1995 Resolved
REMOVE LOCK FROM CHILDS LIFEJACKET STORAGE LOCKER #401
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Fire Fighting
Issued 29 September 1995 Resolved
REPAIR HINGE ON BROKEN FIRE STATION DOOR 607
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Fire Fighting
Issued 29 September 1995 Resolved
PREFORM FIRE DRILL, DUE TO UNSATISFACTORY DRILL CONDUCTED THIS DATE
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Lifesaving
Issued 29 September 1995 Resolved
LOWER ALL STBD SIDE LIFE BOATS AND OPERATE SAME.
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Lifesaving
Issued 29 September 1995 Resolved
PROPERLLY INSTALL AFT STBD LIFERAFT PAINTERS
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Fire Fighting
Issued 29 September 1995 Resolved
INSURE PROPER OPERATION OF FIRE SCREEN DOOR 1.17
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Construction/Loadline
Issued 29 September 1995 Resolved
REPAIR HANDLE ON DOOR B-04
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Lifesaving
Issued 29 September 1995 Resolved
REMOVE ACETONE AND ACETYLENE FROM FWD PROT SIDE BOAT DECK LOCKER.
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Lifesaving
Issued 29 September 1995 Resolved
REMOVE COMBUSTABLE MATERIALS FROM PRINT SHOP
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Fire Fighting
Issued 29 September 1995 Resolved
REMOVE PLYWOOD BULKHEAD FROM GALLEY ON BOAT DECK.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Electrical
Issued 29 September 1995 Resolved
INSTALL PANEL COVER IN 240 VOLT DISTRIBUTION PANEL IN GALLEY ON BOAT DECK
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Fire Fighting
Issued 29 September 1995 Resolved
MAKE FIRE SCREEN DAMPERS 57, 58 AND 59 ON BOAT DECK ACCESSABLE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Fire Fighting
Issued 29 September 1995 Resolved
PROPERLLY MOUNT FIRE EXTINGUISHER #622
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Electrical
Issued 29 September 1995 Resolved
PROPERLLY INSTALL ELECTRIC SYSTEMS TO ELIMINATE STRAY WIRE RUNS IN SHOWTIMELOUNGE STAGE AREA, CONTROL BOTH AREA AND BAR AREA.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Lifesaving
Issued 29 September 1995 Resolved
REPAIR CRACKED ELECTRIC MOTOR MOUNTS ON #7 LIFEBOAT DAVIT
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Fire Fighting
Issued 29 September 1995 Resolved
INSURE PROPER OPERATION OF FIRE SCREEN DOOR 1.12
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Accommodation/Occupational Safety
Issued 29 September 1995 Resolved
REPAIR NUMEROUS LEAKS IN WAY OF SOFT PATCHES ON SANITARY PIPING SYSTEM IN AFTER AUXILARY ENGINE ROOM
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Lifesaving
Issued 29 September 1995 Resolved
PROVE FIXED HALON FIRE EXTINGUISHING SYSTEMS IN #7 AND #8 LFEBOATS ARE SERVICABLE.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Fire Fighting
Issued 29 September 1995 Resolved
PROVE ALL PORTABLE FIRE EXTINGUISHERS HAVE BEEN PROPERLY SERVICED.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Construction/Loadline
Issued 29 September 1995 Resolved
REPAIR HYDROLIC LEAK #13 WTD
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Construction/Loadline
Issued 29 September 1995 Resolved
ENSURE PROPER OPERATION OF PORT BUNKERING STATION SIDE PORT DOGS
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Electrical
Issued 29 September 1995 Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR KW METER IN MAIN CONTORL BOOTH.
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Fire Fighting
Issued 29 September 1995 Resolved
HAVE CLASS SOCIETY VERIFY STRUCTUAL FIRE PROTECTION IS INSTALLED AS REQUIRED AROUND ENGINE ROOM CASING.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Lifesaving
Issued 29 September 1995 Resolved
RENEW #9 LIFEBOAT FALLS TO THE SATISFACTION OF CLASS SOCIETY
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Accommodation/Occupational Safety
Issued 29 September 1995 Resolved
REPAIR LEAKING FRESH WATER VALVES IN LAUNDRY ROOM, PORT SIDE FWD.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Fire Fighting
Issued 29 September 1995 Resolved
PROPERLLY MOUNT FIRE EXTINGUISHER IN STARLIGHT LOUNGE BEHIND BAR
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Electrical
Issued 29 September 1995 Resolved
REMOVE DEAD END WIRES IN CREW STAIRTOWER #12 IN AREA OF DECK 3 BREAKER PANEL.
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Electrical
Issued 29 September 1995 Resolved
INSTALL LIGHT COVER IN FEMALE AFT ACCOMODATIONS AREA, AFT DECK #3 IN AREA OF CABIN 409
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Electrical
Issued 29 September 1995 Resolved
INSTALL LIGHT BULBS IN OPEN SOCKETS IN CREWS QUIET ROOM
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Accommodation/Occupational Safety
Issued 29 September 1995 Resolved
CREW BAR EMERGENCY EXIT BLOCKED CLOSED
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Electrical
Issued 29 September 1995 Resolved
REMOVE DEAD END WIRE IN MENS RESTROOM #3 DECK AFT.
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Electrical
Issued 29 September 1995 Resolved
PROPERLLY MOUNT TRANSFORMER IN POOL BAR STORE ROOM.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Electrical
Issued 29 September 1995 Resolved
REMOVE INPROPER EXTENSION CORDS FROM BEHIND BAR IN STARLIGHT LOUNGE
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Fire Fighting
Issued 29 September 1995 Resolved
PROPERLLY LABEL FIRE STATION 811
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Electrical
Issued 29 September 1995 Resolved
REMOVE LIVE DEAD END WIRE IN UPPER GYM
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Electrical
Issued 29 September 1995 Resolved
REMOVE ALL ITEMS STORED IN MAIN GALLEY ELECTRICAL LOCKER.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Fire Fighting
Issued 29 September 1995 Resolved
PROPERLLY MOUNT FIRE EXTINGUISHER 230
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Fire Fighting
Issued 29 September 1995 Resolved
INSURE PROPER OPERATION OF FIRE SCREEN DOOR 5.9
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Fire Fighting
Issued 29 September 1995 Resolved
INSURE PROPER OPERATION OF FIRE SCREEN DOOR 5.20
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Lifesaving
Issued 25 March 1995 Resolved
Provide Solas Training Manual in accordance with SOLAS 74/III.51.
Condition: Unknown
Due 25 March 1995
Resolved 25 March 1995
Accommodation/Occupational Safety
Issued 25 March 1995 Resolved
Classification society representative to provide documentation proving current installation of portable drums containing chlorine solution, along with associated hoses, is inherent to original system design. If not, system is to be repaired as original.
Condition: Unknown
Due 25 March 1995
Resolved 25 March 1995
Navigation
Issued 25 March 1995 Resolved
Provide non-slip surface in after steering compartment in accordance with _x001C_SOLAS II-1 reg 29-13.2.
Condition: Unknown
Due 7 April 1995
Resolved 7 April 1995
Engineering
Issued 25 March 1995 Resolved
Provide standard discharge connection in accordance with 33 CFR 155.430.
Condition: Unknown
Due 25 March 1995
Resolved 25 March 1995
Engineering
Issued 25 March 1995 Resolved
Hydrostatically test bunker system to 1.5 times MAWP in accordance with 33 CFR 156.170.
Condition: Unknown
Due 25 March 1995
Resolved 25 March 1995
Lifesaving
Issued 25 March 1995 Resolved
Exercise portside lifeboats in water by next quarterly examination.
Condition: Unknown
Due 25 March 1995
Resolved 25 March 1995
Lifesaving
Issued 25 March 1995 Resolved
Replace portside bridge wing EPIRB battery or provide documentation confirming AUG 94 servicing.
Condition: Unknown
Due 1 April 1995
Resolved 10 April 1995
Lifesaving
Issued 25 March 1995 Resolved
Replace expired hydrostatic releases on both bridge EPIRB's prior to departure.
Condition: Unknown
Due 25 March 1995
Resolved 27 March 1995
Navigation
Issued 25 March 1995 Resolved
Classification society representative to examine steering rudder angle indicator to ensure same is accurate. Provide class report to local [name withheld], Puerto Rico.
Condition: Unknown
Due 7 April 1995
Resolved 7 April 1995
Accommodation/Occupational Safety
Issued 11 June 1993 Resolved
SUBMIT PROPOSAL THAT WILL SATISFY CLASS SOCIETY AND U.S. COAST GUARD FOR ANADDITIONAL EMERGENCY EGRESS ROUTE FROM FEMALE CREW BERTHING AREA.
Condition: Unknown
Due 11 June 1993
Resolved 11 June 1993
Fire Fighting
Issued 11 December 1992 Resolved
Replace Fire Control Plan for Bridge. Present FCP is severely faded and illegible in some locations.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Fire Fighting
Issued 25 September 1992 Resolved
Install a fire detector in the vessel's battery room.
Condition: Unknown
Due 25 September 1992
Resolved 25 September 1992
Fire Fighting
Issued 25 September 1992 Resolved
Provide gloves with fire team turn-out gear.
Condition: Unknown
Due 25 September 1992
Resolved 25 September 1992
Construction/Loadline
Issued 19 June 1992 Resolved
ADJUST WATER TIGHT DOORS TO HAVE THE ABILITY TO BE CLOSED SIMULTANEOUSLY_x001C_ (REMOTE BY POWER) WITHIN 60 SECONDS.
Condition: Unknown
Due 19 June 1992
Resolved 19 June 1992
Lifesaving
Issued 20 December 1991 Resolved
MAKE PERMANENT REPAIRS TO #2 PORT LIFE BOAT'S ENGINE/TRANSMISSION AND PROVEPROPER OPERATION.
Condition: Unknown
Due 20 December 1991
Resolved 20 December 1991
Engineering
Issued 20 December 1991 Resolved
PROVIDE A VALVE IN THE DISCHARGE SIDE OF THE OWS WHICH WILL DISCHARGE TO THE BILGES. THIS WILL ALLOW THE OWS TO BE TESTED BY THE COAST GUARD WHILE IN PORT AND NOT ACCIDENTLY DISCHARGE OIL OVERBOARD.
Condition: Unknown
Due 20 December 1991
Resolved 20 December 1991
Lifesaving
Issued 20 September 1991 Resolved
ENGINE ON NUMBER 2 LIFE BOAT WAS FOUND TO BE INOPERABLE. ISSUED REQUIREMENT TO REPAIR BY 27 SEP 91.
Condition: Unknown
Due 27 September 1991
Resolved 7 October 1991
Lifesaving
Issued 20 September 1991 Resolved
PAINT STORES WERE FOUND IN THE VESSELS SHAFT ROOM. ISSUED REQUIREMENT _x001C_ TO RELOCATE PAINT STORES BY 27SEP91.
Condition: Unknown
Due 27 September 1991
Resolved 7 October 1991
Accommodation/Occupational Safety
Issued 20 September 1991 Resolved
EMERGENCY LIGHT FOR ESCAPE TRUNK IN ENGINE ROOM, FOWARD, STARBOARD_x001C_ SIDE WAS FOUND TO BE INOPERABLE. ISSUED REQUIREMNT TO REPAIR _x001C_ NLT 27SEP91.
Condition: Unknown
Due 27 September 1991
Resolved 7 October 1991
Fire Fighting
Issued 21 June 1991 Resolved
VESSEL IS TO PROVIDE AT LEAST ONE (1) SPANNER WRENCH AT EACH FIRE_x001C_ HYDRANT STATION.
Condition: Unknown
Due 21 June 1991
Resolved 21 June 1991
Lifesaving
Issued 21 December 1990 Resolved
REPAIR AND PROVE PROPER OPERATION OF LIFEBOAT #8. REPLACE TRANSMISSION IN LIFEBOAT #2 WITH LIFEBOAT #1 AND PROVE PROPER OPERATION. PROVE OPERATION OFALL LIFEBOATS.
Condition: Unknown
Due 21 December 1990
Resolved 21 December 1990
Fire Fighting
Issued 21 December 1990 Resolved
PROVIDE A LINE DIAGRAM FOR THE FIXED CO2 SYSTEM. THIS DIAGRAM TO BE POSTED IN THE CO2 ROOM.
Condition: Unknown
Due 21 December 1990
Resolved 21 December 1990
Engineering
Issued 29 December 1989 Resolved
REPAIR OWS AND PROVE PROPER OPERATION OF OWS, ALARM, AND AUTOMATIC STOPPINGDEVICE.
Condition: Unknown
Due 29 December 1989
Resolved 29 December 1989
Lifesaving
Issued 29 December 1989 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 29 December 1989
Resolved 29 December 1989
Fire Fighting
Issued 29 December 1989 Resolved
HYDROSTATICALLY TEST ALL CARBON DIOXIDE CYLINDERS, OF THE FIXED TYPE, WHICHHAVE A DATE THAT EXCEEDS TWELVE YEARS.
Condition: Unknown
Due 29 December 1989
Resolved 29 December 1989
Documentation
Issued 29 December 1989 Resolved
PROVIDE AND POST AT LEAST FIVE MARPOL V PLACARDS. ONE IN GALLEY, ONE ON BRIDGE, LOUNGE, AND INCINERATOR ROOM.
Condition: Unknown
Due 29 December 1989
Resolved 29 December 1989
Documentation
Issued 29 December 1989 Resolved
PROVIDE AND POST OIL TRANSFER PROCEDURES AT EACH BUNKER STATION WHICH COMPLY WITH 33 CFR 155.750
Condition: Unknown
Due 29 December 1989
Resolved 29 December 1989
Documentation
Issued 29 December 1989 Resolved
PROVIDE ILLUSTRATIONS AND INSTRUCTIONS IN APPROPRIATE LANGUAGES AND POST INPASSENGER CORRIDORS AND AT MUSTER STATIONS TO INFORM PASSENGERS.
Condition: Unknown
Due 29 December 1989
Resolved 29 December 1989
Lifesaving
Issued 29 December 1989 Resolved
PROPERLY ATTACH EMERGENCY DEBARKATION LADDER AT #12 LIFE BOAT.
Condition: Unknown
Due 29 December 1989
Resolved 29 December 1989
Fire Fighting
Issued 29 December 1989 Resolved
PROVIDE AND ATTACH A FIRE NOZZLE FOR FIRE STATION #523.
Condition: Unknown
Due 29 December 1989
Resolved 29 December 1989
Lifesaving
Issued 29 December 1989 Resolved
PROVIDE AND PROPERLY ATTACH A 30 METER LINE TO ONE RING BUOY FOR A TOTAL OFTWO.
Condition: Unknown
Due 29 December 1989
Resolved 29 December 1989
Lifesaving
Issued 29 December 1989 Resolved
PROVIDE AND POST ENGINE STARTING INSTRUCTIONS IN ACCORDANCE WITH SOLAS REGULATION 9.2.1
Condition: Unknown
Due 29 December 1989
Resolved 29 December 1989
Fire Fighting
Issued 19 December 1987 Resolved
PROVE OPERATION OF MALFUNCTIONING FIRE DOORS BY 27DEC87
Condition: Unknown
Due 19 December 1987
Resolved 19 December 1987
Lifesaving
Issued 19 December 1987 Resolved
CONDUCT FIRE AND BOAT DRILL IN THE PRESANCE OF A COAST GUARD INSPECTOR PRIOR TO 27DEC87
Condition: Unknown
Due 19 December 1987
Resolved 19 December 1987

Ownership record