Records from 1985 to 2000. Most recent: inspection, 11 August 2000.
Inspection history · 59
11 August 2000
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 823759
12 April 1999
Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1434844
23 June 1998
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 823758
5 June 1998
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1469852
21 May 1998
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1451298
4 April 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 34415
24 July 1997
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1452321
15 July 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 110910
25 June 1997
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1407914
7 May 1997
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1463305
6 November 1996
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1168970
7 October 1996
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 840816
10 August 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 74715
7 May 1996
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1419600
3 July 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 881890
5 May 1995
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1403940
24 April 1995
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1459920
30 August 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1178967
29 August 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 869628
16 May 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1169593
20 April 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 691617
31 March 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1167469
21 October 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 691619
21 October 1993
Deficiency Check · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1446021
24 September 1993
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1443411
4 March 1993
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 840424
9 December 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1137269
8 December 1992
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1132538
8 December 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1134869
25 September 1992
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1417469
9 June 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 957199
2 October 1991
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 932187
19 September 1991
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1249905
13 May 1991
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 891602
8 March 1991
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 912228
13 December 1990
Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1241206
6 November 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 906276
20 September 1990
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1217366
29 September 1989
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1323210
11 April 1989
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1203665
31 March 1989
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1349427
14 October 1988
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 890514
14 October 1988
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1203598
17 August 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1037606
18 December 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1008323
2 December 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1028427
29 October 1987
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1025392
29 October 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1027733
6 March 1987
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1323566
3 September 1986
Credit Drydock
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1325164
7 August 1986
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1005466
10 October 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 986103
29 August 1985
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1298709
16 July 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1291147
22 May 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1289233
3 May 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 981608
26 April 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 982350
18 April 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1288366
6 February 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1282531
Fire Fighting › Fire Main › Valves
Issued 5 June 1998
Resolved
MARK / IDENTIFY ALL FIXED FIRE PUMP SYSTEM VALVES.
Condition: Unknown
Due 16 June 1998
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Engineering › Diesel Engine (auxiliary) › Air Cleaner
Issued 5 June 1998
Resolved
REPAIR MAIN ENGINE START LIGHTS IN PILOT HOUSE.
Condition: Unknown
Due 16 June 1998
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Engineering › Diesel Engine (propulsion-reduction gear) › Air Cleaner
Issued 5 June 1998
Resolved
REPAIR THROTTLE CONTROL IN PILOT HOUSE (WON'T STAY IN FORWARD POSITION WHILE MAKING WAY) ALIGN / RENEW CABLES IF NECESSARY.
Condition: Unknown
Due 16 June 1998
Resolved 28 September 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Engineering › Diesel Engine (propulsion-reduction gear) › Air Cleaner
Issued 5 June 1998
Resolved
REPAIR MAIN ENGINE AUDIBLE AND VISUAL ALARMS IN PILOT HOUSE.
Condition: Unknown
Due 16 June 1998
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Engineering › Diesel Engine (propulsion-direct drive) › Air Cleaner
Issued 5 June 1998
Resolved
REPAIR ALL PILOT HOUSE INSTRUMENTATION LIGHTS.
Condition: Unknown
Due 16 June 1998
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 May 1998
Resolved
PROVIDE CG APPROVED FIRST AID KIT.
Condition: Unknown
Due 5 June 1998
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Electrical
Issued 21 May 1998
Resolved
RENEW BROKEN AMP METER IN BATTERY CHARGER POWER PANEL.
Condition: Unknown
Due 5 June 1998
Resolved 29 June 1998
Fire Fighting
Issued 21 May 1998
Resolved
CONDUCT FIRE AND MAN OVERBOARD DRILL TO THE SATISFACTION OF AND IN THE PRESSENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 5 June 1998
Resolved 29 June 1998
Accommodation/Occupational Safety
Issued 21 May 1998
Resolved
REPAIR LEAKING OVERBOARD DISCHARGE LINE ABOVE ENGINE START BATTERIES ON PORT SIDE.
Condition: Unknown
Due 5 June 1998
Resolved 29 June 1998
Documentation
Issued 21 May 1998
Resolved
START AND MAINTAIN A CREW TRAINING LOG.
Condition: Unknown
Due 5 June 1998
Resolved 29 June 1998
Electrical
Issued 21 May 1998
Resolved
PROVIDE 02 FLASHLIGHTS FOR EMERGENCY LIGHTING.
Condition: Unknown
Due 5 June 1998
Resolved 29 June 1998
Documentation
Issued 25 June 1997
Resolved
PROVIDE LOG ATTESTING TO MAN OVERBOARD, FIRE FIGHTING, AND ABANDON SHIP DRILLS.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Lifesaving
Issued 25 June 1997
Resolved
PRODIDE AN APPROVED FIRST AID KIT.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Navigation
Issued 25 June 1997
Resolved
PROVIDE CHARTS, COAST PILOT, LIGHT LIST, NOTICE TO MARINERS, TIDE TABLES, CURRENT TABLES, AND INLAND NAVIGATION RULES.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Construction/Loadline
Issued 25 June 1997
Resolved
CAP 3 HOLES AT BULKHEAD NO. 14, TOP OF THE BULKHEAD, PORT SIDE OF KEEL.
Condition: Unknown
Due 24 July 1997
Resolved 7 August 1997
Engineering
Issued 25 June 1997
Resolved
LABEL DIRECTION OF OPERATION FOR FUEL OIL SHUT OFF VALVES.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Lifesaving
Issued 25 June 1997
Resolved
CONDUCT MAN OVERBOARD, FIRE FIGHTING, AND ABANDON SHIP DRILLS.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Fire Fighting
Issued 25 June 1997
Resolved
RE-NEW FIRE HYDRANT VALVE HANDLE AT PORT SIDE 2ND DECK.
Condition: Unknown
Due 24 July 1997
Resolved 7 August 1997
Fire Fighting
Issued 25 June 1997
Resolved
PROVIDE MOUNT FOR FIRE AXE IN PILOT HOUSE.
Condition: Unknown
Due 24 July 1997
Resolved 7 August 1997
Construction/Loadline
Issued 25 June 1997
Resolved
RE-NEW BILGE STRAINER IN FORWARD VOID.
Condition: Unknown
Due 24 July 1997
Resolved 7 August 1997
Engineering
Issued 25 June 1997
Resolved
INSTALL FLAME SCREENS TO FUEL OIL VENTS PORT AND STARBOARD.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Documentation
Issued 25 June 1997
Resolved
PROVIDE VALID CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 24 July 1997
Resolved 7 August 1997
Lifesaving
Issued 25 June 1997
Resolved
PROVIDE EVIDENCE OF DRUG TESTING AND ENROLLMENT IN A DRUG TESTING CONSORTIUM.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Construction/Loadline
Issued 7 October 1996
Resolved
REINSTALL PIPE CLAMP ON BILGE SUCTION LINE IN #2 VOID (ROOM WITH SEWAGE TANK).
Condition: Unknown
Due 7 November 1996
Resolved 16 October 1996
Accommodation/Occupational Safety
Issued 7 October 1996
Resolved
RENEW SAFETY RAILING ON STBD AFT CORNER OF UPPER DECK INCLUDING PORTION FROM STBD AFT CORNER TO LADDER ALONG TRANSOM.
Condition: Unknown
Due 7 November 1996
Resolved 16 October 1996
Electrical
Issued 7 October 1996
Resolved
INSTALL COVER ON 110VAC PANEL ON PORT SIDE OF PILOT HOUSE.
Condition: Unknown
Due 7 November 1996
Resolved 16 October 1996
Engineering
Issued 7 October 1996
Resolved
INSTALL DOUBLE NUTS ON THROTTLE LINKAGE TO BOTH MAIN DIESEL ENGINES.
Condition: Unknown
Due 7 October 1996
Resolved 16 October 1996
Fire Fighting
Issued 7 May 1996
Resolved
REPLACE BRACKET FOR PORTABLE FIRE EXTINGUISHERS IN BRIDGE AND PORTSIDE OF BRIDGE SUPERSTRUCTURE.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Lifesaving
Issued 7 May 1996
Resolved
REPALCE HYDROSTATIC RELEASES ON PORT AND STBD BUOYANT APPARATUS DISENGAGINGDEVICE.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Lifesaving
Issued 7 May 1996
Resolved
PAINT PORTABLE CONTAINER FOR DISTRESS FLARES IN BRIGHT COLOR. MARK IN CONTRASTING LETTERS AT LEAST 1/2" HIGH "DISTRESS SIGNALS."
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Lifesaving
Issued 7 May 1996
Resolved
REPLACE BATTERIES IN ALL WATERLIGHTS ATTACHED TO LIFESAVING GEAR. MAINTAINRECORD OF EXPIRATION DATE OR REPLACEMENT DATE.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Electrical
Issued 7 May 1996
Resolved
LABEL DC PANEL BREAKERS & VENT PANEL BREAKERS ON PORT SIDE ENGINE ROOM. LABEL BREAKERS ("SPARE" IF UNUSED) ON PANEL IN PILOT HOUSE.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Navigation
Issued 7 May 1996
Resolved
POST A DURABLE PLACARD NEXT TO ALL RADIOTELEPHONE INSTALLATIONS WITH THE EMERGENCY BROADCAST INSTRUCTIONS AND INFORMATION SPECIFIC TO VESSEL (RECOMMENDED FORMAT IN 46 CFR 184.510).
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Lifesaving
Issued 7 May 1996
Resolved
REPLACE OR REPAIR BUOYANT APPARATUS STORED ON STBD SIDE ABOVE PILOT HOUSE.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Engineering
Issued 7 May 1996
Resolved
INSTALL TACHOMETER FOR ENGINE ON PORT SIDE PILOT HOUSE CONSOLE.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Documentation
Issued 7 May 1996
Resolved
POST STABILITY LETTER FOR MANUEL HENRIQUEZ ON BRIDGE.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Engineering
Issued 7 May 1996
Resolved
PLACE GUARD OVER EXPOSED BELTS ON FWD PART OF STBD MAIN ENGINE.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Navigation
Issued 7 May 1996
Resolved
REPLACE STEERING CABLE IN AFT STEERING COMPARTMENT.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Accommodation/Occupational Safety
Issued 7 May 1996
Resolved
REPAIR OR RENEW DISCHARGE PIPE FOR SEWAGE TANK LEADING FROM PORT SIDE.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Engineering
Issued 5 May 1995
Resolved
COMPLETE PARTIAL INSTALLATION OF TWO (2) PIPE HANGERS OVER PORT MAIN ENGINEHEAT EXCHANGER._x001C_
Condition: Unknown
Due 1 June 1995
Resolved 9 May 1995
Construction/Loadline
Issued 5 May 1995
Resolved
INSTALL ALL VOID COVERS.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Lifesaving
Issued 5 May 1995
Resolved
LABLE ALL LIFEJACKET STORAGE LOCATIONS WITH SIZE AND NUMBER.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Lifesaving
Issued 5 May 1995
Resolved
STOW ALL CHILDREN'S LIFEJACKETS SEPARATELY FROM FROM ADULT LIFEJACKETS.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Fire Fighting
Issued 5 May 1995
Resolved
INSTALL PROPER BRACKETS FOR PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Engineering
Issued 5 May 1995
Resolved
ADJUST AND PROVE PROPER OPERATION OF STARBOARD PROPULSION SHAFT PACKING.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Accommodation/Occupational Safety
Issued 5 May 1995
Resolved
PROPERLY REPAIR OR REPLACE POTABLE WATER PUMP.
Condition: Unknown
Due 1 June 1995
Resolved 9 May 1995
Electrical
Issued 5 May 1995
Resolved
RECALIBRATE OR REPLACE DIESEL GENERATOR VOLTMETER. CONFIRM PROPER OUTPUT VOLTAGE.
Condition: Unknown
Due 1 June 1995
Resolved 9 May 1995
Electrical
Issued 5 May 1995
Resolved
REMOVE PLASTIC "WIRE TIES" FROM ENGINE ROOM WIRING. REPLACE WITH METALLIC CLAMPS.
Condition: Unknown
Due 1 June 1995
Resolved 9 May 1995
Engineering
Issued 5 May 1995
Resolved
TIGHTEN LOOSE SAFETY COVER AT FRONT OF DIESEL GENERATOR.
Condition: Unknown
Due 1 June 1995
Resolved 9 May 1995
Engineering
Issued 5 May 1995
Resolved
REPAIR OR REPLACE MAIN ENGINE TACHOMETERS ON THE BRIDGE.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Construction/Loadline
Issued 24 April 1995
Resolved
CROP AND RENEW TO GOOD STEEL BOTTOM PLATING IN ENGINE ROOM BETWEEN THE MAINENGINE FOUNDATIONS FROM THE AFT BUKLHEAD FORWARD. ALSO CROP AND RENEW TO GOOD STEEL BOTTOM PLATING OF #3 VOID FROM KEEL OUTBOARD TO THE FIRST LONGITIDINAL FRAME FROM FORWARD BULKHEAD AFT.
Condition: Unknown
Due 23 May 1995
Resolved 23 May 1995
Engineering
Issued 30 August 1994
Resolved
Repair engine exhaust leak on stbd side of engine room.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Accommodation/Occupational Safety
Issued 30 August 1994
Resolved
Repair MSD piping and prove proper operation of all 4 devices.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Lifesaving
Issued 30 August 1994
Resolved
Provide copies of emergency ck-off list in spanish and post in prominent locations about ship.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Accommodation/Occupational Safety
Issued 30 August 1994
Resolved
Repair all deck lights and electrical light wiring about both decks.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Lifesaving
Issued 30 August 1994
Resolved
Replace 1 X 20-man buoyant apparatus.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Lifesaving
Issued 30 August 1994
Resolved
Ensure all waterlights function properly.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Lifesaving
Issued 30 August 1994
Resolved
Mark all life preserver stowage locations clearly.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Lifesaving
Issued 30 August 1994
Resolved
Renew lock on main deck life preserver stowage locker.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Lifesaving
Issued 30 August 1994
Resolved
Stow all child life preservers in separate location from adult life preservers.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Fire Fighting
Issued 30 August 1994
Resolved
Renew stowage brackets for CO2 extinguishers and ensure all brackets mounted close to deck.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Construction/Loadline
Issued 30 August 1994
Resolved
Repair broken railing about ship.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Engineering
Issued 30 August 1994
Resolved
Make engine space clean and presentable for inspection, including full operational test of all equipment included therein.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Documentation
Issued 21 October 1993
Resolved
Provide documentation that Ports Authority complies with drug testing program in accordance with 46 Code of Federal Regulations Part 16.
Condition: Unknown
Due 21 October 1993
Resolved 21 October 1993
Accommodation/Occupational Safety
Issued 21 October 1993
Resolved
Demonstrate proper operation of toilets and wash basins as per 46 Code of Federal Regulations 177.30-5.
Condition: Unknown
Due 21 October 1993
Resolved 21 October 1993
Documentation
Issued 21 October 1993
Resolved
Provide copy of Desigation letter for senior deck hand. Letter to be posted on the bridge as per Certificate of Inspection. To be completed prior to placing vessel in service.
Condition: Unknown
Due 9 November 1993
Resolved 9 November 1993
Lifesaving
Issued 21 October 1993
Resolved
Provide system that lets buoyant appartaus's float free. 46 Code of Federal regulations 180.20(e).
Condition: Unknown
Due 21 October 1993
Resolved 21 October 1993
Construction/Loadline
Issued 24 September 1993
Resolved
Crop and renew wasted steel hull and bulkhead plating as per gauging reportand owner's repair proposal.
Condition: Unknown
Due 27 January 1994
Resolved 27 January 1994
Construction/Loadline
Issued 24 September 1993
Resolved
Crop and renew approx. 3" X 3' in way of the keel port side forward bulkhead of steering compartment.
Condition: Unknown
Due 28 September 1993
Resolved 28 September 1993
Construction/Loadline
Issued 24 September 1993
Resolved
Remove cement patch around both rudder post. Crop and renew approx. 2 1/2'X 2 1/2' of hull plate in way of both rudder post.
Condition: Unknown
Due 28 September 1993
Resolved 28 September 1993
Engineering
Issued 8 December 1992
Resolved
Prove proper operation of main engine's oil pressure guages on the bridge.
Condition: Unknown
Due 8 December 1992
Resolved 8 December 1992
Navigation
Issued 8 December 1992
Resolved
Provide proper light fixture for bow light.
Condition: Unknown
Due 8 December 1992
Resolved 8 December 1992
Engineering
Issued 8 December 1992
Resolved
Re-placard fuel oil shut-off valves port and starboard sides on main deck.
Condition: Unknown
Due 8 December 1992
Resolved 8 December 1992
Construction/Loadline
Issued 25 September 1992
Resolved
Install proper hose on discharge side of hand bilge pump._x001C_
Condition: Unknown
Due 26 October 1992
Resolved 8 December 1992
Electrical
Issued 25 September 1992
Resolved
Replace bolt on port forward light fixture in engineroom.
Condition: Unknown
Due 26 October 1992
Resolved 8 December 1992
Fire Fighting
Issued 25 September 1992
Resolved
Properly secure all fire extingushers.
Condition: Unknown
Due 26 October 1992
Resolved 8 December 1992
Engineering
Issued 25 September 1992
Resolved
Insulate exhausts on port and starboard propulsions engines and ship service generator with proper material.
Condition: Unknown
Due 26 October 1992
Resolved 8 December 1992
Engineering
Issued 25 September 1992
Resolved
Remove dead end wires on port and starboard engines.
Condition: Unknown
Due 26 October 1992
Resolved 8 December 1992
Engineering
Issued 25 September 1992
Resolved
Overboard discharge piping above port propulsion engine needs to be properly bracketed.
Condition: Unknown
Due 26 October 1992
Resolved 8 December 1992
Engineering
Issued 25 September 1992
Resolved
Tighten union on port main diesel engine overboard discharge._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 October 1992
Resolved 8 December 1992
Engineering
Issued 25 September 1992
Resolved
Repair leak on air/water seperator on air tank in engine room._x001C_
Condition: Unknown
Due 26 October 1992
Resolved 8 December 1992
Construction/Loadline
Issued 25 September 1992
Resolved
Place proper hull markings on stern of vessel._x001C_
Condition: Unknown
Due 26 October 1992
Resolved 10 December 1992
Construction/Loadline
Issued 25 September 1992
Resolved
Extend deck drains from overhead on second deck to main deck.
Condition: Unknown
Due 26 October 1992
Resolved 8 December 1992
Electrical
Issued 25 September 1992
Resolved
Provide proper metal guard for light fixtures in engineroom.
Condition: Unknown
Due 26 October 1992
Resolved 8 December 1992
Electrical
Issued 25 September 1992
Resolved
Line all battery boxes with proper material - Lead on bottom with 3" up thesides.
Condition: Unknown
Due 26 October 1992
Resolved 8 December 1992
Engineering
Issued 25 September 1992
Resolved
Prove proper operation of bridge main engine tachometers.
Condition: Unknown
Due 26 October 1992
Resolved 8 December 1992
Lifesaving
Issued 25 September 1992
Resolved
Provide quick release device for bouyant apparatus and wood slats between them.
Condition: Unknown
Due 26 October 1992
Resolved 8 December 1992
Electrical
Issued 19 September 1991
Resolved
PROVIDE COVER AND SWITCH DIRECTORY FOR PANEL LOCATED ON PORT SIDE OF THE WHEELHOUSE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 October 1991
Resolved 8 October 1991
Engineering
Issued 19 September 1991
Resolved
REPAIR WATER LEAK STARBOARD SIDE INBOARD OF SKKIN VALVE ON GENERATOR COOLING WATER DISCHARGE LINE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1991
Resolved 8 October 1991
Electrical
Issued 19 September 1991
Resolved
PROVIDE BLANK FOR AC PANEL LOCATED PORT SIDE IN ENGINEROOM. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 October 1991
Resolved 8 October 1991
Electrical
Issued 19 September 1991
Resolved
PROVIDE BLANK AND DIECTORY FOR VENT PANEL LOCATED PORT SIDE IN ENGINEROOM._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 October 1991
Resolved 8 October 1991
Construction/Loadline
Issued 19 September 1991
Resolved
REPLACE SOFT HOSE LOCATED ON BILGE MANIFOLD IN ENGINEROOM WITH STEEL PIPE OF SAME MATERIAL EXISTING ON THE MANIFOLD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 October 1991
Resolved 8 October 1991
Navigation
Issued 19 September 1991
Resolved
REPLACE PORT RUBBER STOCK BEARING. CONDUCT UNDERWAY TEST IN PRESENCE OF A MARINE INSPECTOR TO PROVE PROPER OPERATION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 October 1991
Resolved 8 October 1991
Construction/Loadline
Issued 19 September 1991
Resolved
BOLT BILGE SUCTION PIPING IN THE #4 VOID IN THE BRACKET LOCATED ON FORWARD BULKHEAD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 October 1991
Resolved 8 October 1991
Construction/Loadline
Issued 19 September 1991
Resolved
CROP AND RENEW BACK TO GOOD MATERIAL THREE AREAS AS MARKED ON SIDE BULKHEADON PORT SIDE OF MAIN DECK FORWARD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 October 1991
Resolved 8 October 1991
Construction/Loadline
Issued 19 September 1991
Resolved
CROP AND RENEW, BACK TO GOOD METAL, HOLE LOCATED ON PORT SIDE OF WHEELHOUSE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 October 1991
Resolved 8 October 1991
Engineering
Issued 19 September 1991
Resolved
PROVIDE SAFETY GUARDS FOR BOTH MAIN DIESEL ENGINES, S/S GENERATOR AND FRESHWATER PUMP LOCATED IN ENGINEROOM. (AREAS ARE ON ALL EXPOSED PULLEYS AND FLYWHEELS.)_x001C_ _x001C_
Condition: Unknown
Due 18 October 1991
Resolved 8 October 1991
Electrical
Issued 19 September 1991
Resolved
PROVIDE SWITCH DIRECTORY FOR PANEL LOCATED ON PORT SIDE OF HELM IN WHEELHOUSE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 October 1991
Resolved 8 October 1991
Electrical
Issued 19 September 1991
Resolved
PROVIDE THREE BLANKS FOR LIGHT INDICATOR PANEL LOCATED ON STARBOARD SIDE OFMAIN DIESEL ENGINE CONTROLS IN PILOTHOUSE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 October 1991
Resolved 8 October 1991
Engineering
Issued 19 September 1991
Resolved
REPAIR EXHAUST LEAK AT STARBOARD MAIN DIESEL ENGINE INBOARD EXHAUST AT TOP FLEX JOINT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 October 1991
Resolved 8 October 1991
Fire Fighting
Issued 19 September 1991
Resolved
PROVIDE PRESSURE GUAGE FOR DISCHARGE SIDE OF FIRE/BILGE PUMP AND PROVE PUMPDEVELOPS A MINIMUM PRESSURE OF 60 PSI AT PUMP OUTLET IN ACCORDANCE WITH 46 CFR 181.10-1(C).
Condition: Unknown
Due 4 October 1991
Resolved 8 October 1991
Lifesaving
Issued 13 December 1990
Resolved
PROVIDE AN ADDITIONAL WEAKLINK AND STOWAGE LOCATION FOR BUOYANT APPARATI SOTHAT NO MORE THAN 4 BUOYANT APPARATI CONNECTED TO THE WEAKLINK.
Condition: Unknown
Due 13 December 1990
Resolved 13 December 1990
Electrical
Issued 13 December 1990
Resolved
PROVIDE MARINE TYPE CONNECTORS FOR WIRE SPLICES FOR RADIO INSTALLATION ON BRIDGE.
Condition: Unknown
Due 13 December 1990
Resolved 13 December 1990
Lifesaving
Issued 20 September 1990
Resolved
RENEW RETROFLECTIVE TAPE ON 15 ADULT LIFE JACKETS AS SEPERATED ON DECK PRIOR TO STOWAGE.
Condition: Unknown
Due 20 September 1990
Resolved 20 September 1990
Fire Fighting
Issued 20 September 1990
Resolved
REMOVE RUBBER HOSE SECTION FROM FIRE MAIN LINE LOCATED IN CENTER SECTION OVERHEAD IN ENGINEROOM. RE-INSERT SECTION OF PIPE AS ORIGINAL.
Condition: Unknown
Due 20 September 1990
Resolved 20 September 1990
Navigation
Issued 20 September 1990
Resolved
PLACE 10 POINT SHIELD ON ON AFT SECTION OF MAST HEAD LIGHT SO AS TO CONFORMTO THE RULES OF THE ROAD REQUIREMENTS.
Condition: Unknown
Due 20 September 1990
Resolved 20 September 1990
Accommodation/Occupational Safety
Issued 20 September 1990
Resolved
MAKE STARBOARD SIDE FORWARD LADIES TOILET OPERATIONAL.
Condition: Unknown
Due 20 September 1990
Resolved 20 September 1990
Fire Fighting
Issued 29 October 1987
Resolved
1 B-II FIRE EXTINGUISHER IN E/R NEEDED SERVICING.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Construction/Loadline
Issued 29 October 1987
Resolved
CRACKED WELD, PORT SIDE AFT CORNER AT MAIN DECK IN RUDDER COMPARTMENT
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Construction/Loadline
Issued 29 October 1987
Resolved
CRACKED WELD, MIDWAY UP, STARBOARD SIDE, MIDWAY ALONG THE SIDE OF COMPART- MENT JUST FORWARD OF RUDDER COMPARTMENT
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Lifesaving
Issued 29 October 1987
Resolved
3 WATERLIGHTS FOR BUOYANT APPARATUS NON-OP
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Fire Fighting
Issued 29 October 1987
Resolved
VSL MISSING 1 B-II FIRE EXTINGUISHER IN ENGINE ROOM.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Fire Fighting
Issued 29 October 1987
Resolved
VSL MISSING PORTABLE HAND PUMP FOR FIREFIGHTING (AND BILGE SYSTEM)
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Documentation
Issued 29 October 1987
Resolved
VSL'S FCC CERTIFICATE HAD EXPIRED ON 14 OCT 85
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Documentation
Issued 29 October 1987
Resolved
LENGTH ON COI AND ON DOCUMENT DID NOT MATCH. DOCUMENT WAS INCORRECT. NEEDS TO BE CORRECTED.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Lifesaving
Issued 29 October 1987
Resolved
ALL PYRO (FLARES AND SMOKE) WERE OUTDATED.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Accommodation/Occupational Safety
Issued 29 October 1987
Resolved
MEN'S HEAD EXTREMELY UNSANITARY, ODOR ALMOST UNBEARABLE.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Lifesaving
Issued 29 October 1987
Resolved
REJECTED 37 PFDS.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Navigation
Issued 29 October 1987
Resolved
HYDRO TEST AIR RECEIVER OR SHOW EXEMPTION FROM REQUIRED PERIODIC TESTING (LESS THAN 5 CUBIC FEET).
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Lifesaving
Issued 16 July 1985
Resolved
PROVIDE SUITABLE STOWAGE AREA, 100 FOOT PAINTER AND WEAK LINK FOR THE VESSEL'S LIFEFLOATS.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Accommodation/Occupational Safety
Issued 18 April 1985
Resolved
REPAIR UPPER DECK WIRE MESH USED FOR PASSENGER SAFETY GUARD WHERE WASTED AND PULLING AWAY FROM SUPPORTS.
Condition: Unknown
Due 18 April 1985
Resolved 18 April 1985
Construction/Loadline
Issued 18 April 1985
Resolved
CROP OUT AND RENEW WHERE WASTED THE METAL AROUND THE FUEL OIL FILL PORTSIDE
Condition: Unknown
Due 18 April 1985
Resolved 18 April 1985
Construction/Loadline
Issued 18 April 1985
Resolved
WELD CRACKED FRAMES IN STEERING COMP. IN WAY OF STBD #2 #3 FRAMES AT TOP ATTRANSOM. (2)
Condition: Unknown
Due 18 April 1985
Resolved 18 April 1985
Engineering
Issued 18 April 1985
Resolved
REPAIR LEAKING PIPING CONNECTIONS. PORT AND STBD MAIN ENGINE OVERBOARDS. GENERATOR OVERBOARD.
Condition: Unknown
Due 18 April 1985
Resolved 18 April 1985
Construction/Loadline
Issued 18 April 1985
Resolved
REPAIR HOLED AREA MAIN DECK AFT PORT CORNER WHERE LEAKING INTO STEERING SPACE.
Condition: Unknown
Due 18 April 1985
Resolved 18 April 1985
Construction/Loadline
Issued 18 April 1985
Resolved
WELD AFT PORT CORNER WHERE CRACKED. WHERE HULL PLATE MEETS CORNER RUB RAIL
Condition: Unknown
Due 18 April 1985
Resolved 18 April 1985