Records from 1990 to 2019. Most recent: operational control imposed, 30 September 2019.
Inspection history · 131
8 April 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6657934
11 March 2019
Administrative Inspection · Ballast Water Examination · ISPS II Exam · Deficiency Check · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6640364
4 March 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6635836
2 February 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6618958
21 January 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6612918
23 December 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6602155
7 November 2018
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6576249
30 October 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6571213
1 October 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6552439
27 August 2018
Ballast Water Examination · ISPS II Exam · PII Safety Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6523998
25 August 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6519579
20 July 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6485423
9 May 2018
PII Safety Exam · Ballast Water Examination · Deficiency Check · ISPS II Exam · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6407881
4 May 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6405595
29 March 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6381037
27 February 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6362724
23 February 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6360486
2 January 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6331054
5 December 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6318757
14 November 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6306596
31 October 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6298185
28 March 2017
PII Safety Exam · ISPS II Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6112751
7 March 2017
In-Service Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6100599
8 February 2017
PII Safety Exam · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6084458
6 September 2016
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5993703
28 July 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5954884
1 February 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5807284
24 December 2015
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5785116
26 August 2014
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4963699
23 June 2014
PII Safety Exam · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4896825
20 June 2014
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4894081
18 March 2014
Deficiency Check · Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4815556
10 March 2014
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4813086
23 February 2012
Random ISPS/MTSA-No PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4249995
12 December 2011
ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4206253
4 February 2011
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3938110
27 November 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3898998
12 October 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3867303
8 September 2010
ISPS II Exam · Ballast Water Examination · PII Safety Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3844928
2 September 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3838648
26 December 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3654393
14 December 2009
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3650046
11 December 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3646612
11 April 2009
ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3450100
15 March 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3431868
13 January 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3392359
13 January 2009
ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3396806
16 December 2008
ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3380739
16 December 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3381481
11 December 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3378494
25 August 2008
Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3308341
10 August 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3294193
7 August 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3292082
2 July 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3255420
1 July 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3253702
22 May 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3253735
20 May 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3211697
23 April 2008
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3193988
5 April 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3178801
2 April 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3176438
10 January 2008
PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3125852
6 January 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3125467
4 January 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3124992
20 March 2007
MARPOL Annex II Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2891106
3 August 2006
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2735388
31 July 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2732110
25 March 2006
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2609365
24 March 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2609145
1 March 2006
NPV Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2594093
28 February 2006
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2593354
27 February 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2592901
13 October 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2513801
29 July 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2444563
21 July 2005
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2434086
29 June 2005
Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2407546
28 June 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2406454
30 April 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2346617
27 April 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2343804
25 March 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2319201
1 February 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2284807
8 January 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2271029
16 December 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2260268
1 December 2004
Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2251075
29 November 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2249852
27 November 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2248531
26 November 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2248285
21 October 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2225264
22 September 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2202293
18 September 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2198638
30 August 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2180930
16 August 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2167961
13 August 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2164942
25 July 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2153142
23 July 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2142664
29 June 2004
ISPS II Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2115208
21 June 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2105808
16 June 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2100088
29 May 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2081367
28 May 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2108346
21 May 2004
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2074134
17 May 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2070406
6 April 2004
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2038260
8 March 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2020249
8 March 2004
Type not recorded
No type recorded · USCGC MONHEGAN (WPB 1305) · USCG Southeast District (CGD-SE) · Activity 2032134
28 December 2003
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1970189
12 November 2003
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1946431
10 April 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1771344
23 March 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1761675
7 November 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1702242
15 May 2002
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1616360
10 April 2002
Annual Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1603027
28 November 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 295923
12 April 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 289092
28 March 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 288628
20 February 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 287281
20 June 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 279135
24 May 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 278248
17 May 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 278171
22 February 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 275701
14 October 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 396325
17 May 1996
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 715230
30 March 1996
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 389449
12 February 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 387841
2 January 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 386621
3 October 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 383471
21 September 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 383046
7 April 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 365660
9 February 1992
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 459184
30 August 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 677575
6 June 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 344281
18 July 1990
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 338328
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 March 2019
Resolved
07113 - A cargo ship shall be provided with fire pumps, water service pipes, hydrant and hoses complying with Regulation 56: shall be sufficient for the effective distribution of the maximum required discharge. The ship’s fire main piping on the weather deck was severely wasted showing signs of large size holes. During the operational test of the system significant leaks were discovered which rendered the system unable to properly maintain water supply to the system in order to fight a fire. The water was leaking at approximately 100-150 gallons per minute. 60 SOLAS Ch. II/Reg. 56(c)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 22 March 2019
Resolution: Sector Miami has received flag attestation attesting to repairs, audits and their findings
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 14 March 2019
Resolved
Fire extinguishing appliances shall be kept in good order and available for immediate use. The fire hydrant on the second deck (Aft) had a barbecue grill tied off to fire hose connection blocking access, preventing immediate use.
60 SOLAS CH. II/Reg.66
Action required: 30 - Ship detained
Resolved 22 March 2019
Resolution: Sector Miami has recieved flag attestion attesting to repairs, audits and their findings
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 14 March 2019
Resolved
Objective evidence discovered during an expanded ISM exam revealed the following non-conformities: the vessel failed to fully implement the requirements of the ISM Code through their SMS procedures as evident by the following deficiencies indicating that the ship and/or company are not meeting the SMS requirements. Recommend an external audit. 74 SOLAS (2014) IX/3.1, 6.2 ISM Code Part A
The company is responsible for ensuring that adequate resources and shore-based support are provided to enable persons to carry out their functions. During a conversation with the current Captain and the previous Captain, it was determined the previous Captain of the vessel made mention to the company that the overall condition of the fire main had been in need of immediate repair for several months. The previous Captain additionally informed the PSCO that the DPA was verbally notified several times dating back to October 2018. ISM Code 10.1, ISM Code 10.2.3
The safety management system should include procedures ensuring that nonconformities and hazardous situations are reported to the company. Although the vessel Captain made verbal notification of the condition of the fire main they did not follow SMS procedures by properly filling out and filing the “Advice of Defect and Repair” form. ISM Code 9.1
Action required: 30 - Ship detained
Resolved 22 March 2019
Resolution: Sector Miami has received flag attestation attesting to repairs, audits and their findings
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 11 March 2019
Resolved
Ships constructed before 01july 1998 shall meet the requirements of 1.1 & 1.2:The view of the sea surface from the conning position shall not be obscured: No blind sectors caused by cargo, cargo gear. Vehicles loaded on top of containers are obstructing the required view of the sea. 74 SOLAS (14 Cons.) Ch.V/Reg. 1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 March 2019
Resolution: Sector Miami has received flag attestation attesting to repairs, audits and their findings
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo Securing Manual
Issued 11 March 2019
Resolved
All Cargoes shall be loaded, stowed and secured throughout the voyage in accordance with the Cargo Securing Manual. Vehicles loaded on vessel are stowed on the roofs of 20' containers that are structurally failing due to the weight of the vehicles. The failure of the roof will cause the vehicles to become unsecured during the voyage. 74 SOLAS (14 Cons.) Ch. VI/Reg. 5.6
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 March 2019
Resolution: Sector Miami has received flag attestation attesting to repairs, audits and their findings
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 August 2018
Resolved
After any survey of the ship no chang eshall be made in the structural arrangements, machinery, equipments covered by the survey without the sanction of the Administration. PSCO observed pressure relief valves gagged open with hose clamps. In addition, main air receiver without proper safety relief and corroded. 60SOLAS CH 1/11 17bc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2018
Resolution: Pressure relief valves have been replaced
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 August 2018
Resolved
After any survey of the ship no change shall be made in the structural arrangements , machinery, equipments covered by the survey without the sanction of the Administration. Approx 4' diameter steel engine room ventilation cover wasted and in danger of falling onto persons below. 60SOLAS CH 1/11 17bc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2018
Resolution: Ventilation cover has been repaired and is welded in place.
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 27 August 2018
Resolved
All ships 150 gross tonsand above shall be fitted with a BNWAS. Vessel does not have BNWAS as indicated on Equipment FORM E. 74SOLAS(14Cons.) CH V/Reg 19.2.2 17bc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2018
Resolution: BNWAS has been installed and Captain of vessel verified the alarm in front of PSCO's
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 August 2018
Resolved
Hoses shall together with any necessary fittings and tools be kept ready for use in conspicuous positions near the water service hydrants or connections. Missing nozzles in hydrant station starboard side engine room. 60SOLAS CH 2/56(f)
Action required: 10 - Deficiency Rectified
Resolved 27 August 2018
Construction/Loadline › Hull › Side Shell
Issued 12 June 2018
Resolved
A temporary repair was made for a hole found in the ship's hull that was allowing the ingress of sea water in Ballast Tank #1. The vessel must make permanent reparis prior to the next U.S. port after sailing foreign.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 June 2018
Resolved 2 August 2018
Resolution: Marine Chemist Certificate submitted. PSCO went out to verify weld and deemed repairs to be in compliance with regulations.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 11 May 2018
Resolved
1240. The means for securing and maintaining weather tightness shall be to the satisfaction of the Administration. The arrangements shall ensure that the tightness can be maintained in any sea conditions, and for this purpose tests shall be required at the initial survey and may be required at periodical surveys and at annual inspections or at more frequent intervals. The accordion cargo hatch cover is heavily wasted and has at least 5 holes throughout. Several closing devices used to secure the hatch in the closed position are missing or wasted. ICLL 66 ANNEX I/16(4) 30bc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 12 June 2018
Resolution: PSCOs observed steel welding repairs made to cargo hatch cover and observed no daylight entering cargo hold.
Construction/Loadline › Hull › Longitudinal Frame
Issued 11 May 2018
Resolved
0299. After any survey of the hull has been completed, no change shall be made in the structural arrangements covered by the survey, without the sanction of the Administration. The vessel’s last survey was in November 2017 with no areas of concern identified. However, PSCOs found wastage and holes along the steel beams supporting the landings in the ladder wells into the cargo hold. 60 SOLAS 1/11. 30bc
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 12 June 2018
Resolution: PSCOs observed longitudnal beam plate-welded on both sides in order to effect repairs and strengthen the landing support in the previously wasted areas.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 May 2018
Resolved
0820. Mechanical and equipment presenting hazards to personnel shall have installations of built-in guards for moving parts. The built in guard on the anchor windlass is wasted exposing the gears and presents a hazard to the crew. ILO 147 ART.4 & PWSA 33 USC 1233(B) 17bc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2018
Resolution: Anchor windlass guard welded in place on starboard windlass in order to protect crew from involved hazard.
Construction/Loadline › Hull › Hull Plating
Issued 9 May 2018
Resolved
1299. The Administration shall satisfy itself that the general structural strength of the hull is sufficient for the draught corresponding to the freeboard assigned. Significant wastage and penetrations were discovered in the vessel’s starboard side ballast tanks. The forepeak tank was found to be leaking into ballast tank #1 STBD side. In addition, when ballast tank #1 was drained, a hole approximately 2 inches by 3 inches in the ship's hull allowed for the passage of sea water into the tank. The last survey in November 2017 found no areas of concern in the affected areas. ICLL 66 ANNEX I CH1/REG.1 30bc
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 12 June 2018
Resolution: PSCOs observed entire plate replaced between forepeak tank and ballast #1 and no further wasted observed in this area.
Construction/Loadline › Structures › Machinery Space Opening
Issued 28 March 2017
Resolved
Machinery Space openings shall be properly framed and efficiently enlcosed by steel casing. Access openings on such casings shall be fitted with doors complying with reg 12(1). Other openings in such casings shall shall be fitted with equivalent covers, permanently attached in their proper position. Bulkhead leading into engine room has a 10x10 inch square with a temporary cover forward port side.
Action required: 705 - Other - as specified
Due 11 April 2017
Resolved 20 April 2017
Resolution: Permanent insert was welded into the bilkhead.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 28 March 2017
Resolved
Fire protection systems and appliances shall be maintained ready for use and shall be properly inspected. 01 out of 02 fire suits onboard was found with tears on leg. 74 SOLAS (14) II-2/Reg 14.1.1-14.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 March 2017
Resolution: Firemans outfit confirmed replaced and ready for use by PSCO.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 17 March 2017
Resolved
2515 - Company resp - ISM related def - Objective evidence discovered during an expanded ISM exam revealed the following non-conformities. The vessel failed to fully implement the requirements of the ISM Code through their SMS procedures as evident by the following identified deficiencies. Recommend external audit. 74 SOLAS 14 con. IX/3.1, ISM Code Part A
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2017
Resolution: ISM Audit conducted by Flag State 19Mar17
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 17 March 2017
Resolved
2525 - Masters resp - ISM related def - The company should ensure that master is fully conversant with company's safety management system. Master is not familiar with the familiarization for the procedures to report hazardous occurrences. ISM Code 6.1.2.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2017
Resolution: ISM Audit conducted by Flag State 19Mar17
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 17 March 2017
Resolved
2545 - Reports of non-conformities - ISM related def - The company should ensure that any non-conformity is reported. The vessel had a fuel leak from piping that leads to the starboard #1 tanks. The fuel leaked into ballast tank #4. No non-conformities were made to the company. ISM Code 12.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2017
Resolution: ISM Audit conducted by Flag State 19Mar17
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 7 March 2017
Resolved
0940 - Ballast fuel and other tanks- The condition of the ship and its equipment shall be maintainted to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons onboard. The #4 center ballast tank was found to contain fuel oil. 74 SOLAS (14 cons) Ch 1/Reg 11a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2017
Resolved 17 March 2017
Resolution: A fuel pipe that passes through ballast tank #4 was holed. A section of the pipe was cropped and replaced.
Documentation › Logs/Records › Oil Record Book
Issued 7 March 2017
Resolved
1710 -Oil record book- Every ship of 400 GT and above shall be provided with an oil record book. The ORB shall be in the form specified in Appendix III to the Annex. ORB did not identify the quantity and tanks for fuel oil transfer during bunkering. MARPOL (11 cons) Annex I/Reg 17
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 April 2017
Resolution: Proper soundings have been recorded.
Documentation › Logs/Records › Bunker Delivery Notes/Samples
Issued 7 March 2017
Resolved
2199 -Other (MARPOL operational def)- The bunker delivery note shall be kept on board the ship in such place as to be readily available for inspection at all reasonable times and retained for three years. Chief Engineer could not produce any bunkering receipts. MARPOL (11 cons) Annex VI/Reg 18
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 April 2017
Resolution: Bunker notes have been rpovided onboard.
Fire Fighting › Fire Pumps › Arrangement
Issued 8 February 2017
Resolved
0740 Pumps - On a cargo ship where a fire in any one comprtment could put all the pumps out of action, there must be an alternative means of providing water for fire fighting. Alternative means for providing water for fire fighting not provided. Fire pump inoperable. SOLAS 60 Reg. 65(b)(ii) 17bc
Action required: 17 - Rectify deficiencies prior to departure
Due 8 February 2017
Resolved 13 February 2017
Resolution: Sector Miami attended vessel to conduct a deficiency check on M/V KRISTINA after receiving an attestation from class regarding deficiencies issued on 08FEB17. All deficiencies have been rectified. Fire Pump is in working conditions, COTP Rescinded.
Fire Fighting › Fire Hoses › Condition
Issued 8 February 2017
Resolved
0730 Fire Appliances - Fire extinguishing appliances shall be kept in good order and available for immediate use at all times. Port forward hose station missing fire hose. SOLAS 60 Reg. 66 17bc
Action required: 17 - Rectify deficiencies prior to departure
Due 22 February 2017
Resolved 13 February 2017
Resolution: Missing Fire Hoses in station were replace with a new sets of hoses.
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 8 February 2017
Resolved
0199 Other - All cargoes shall be loaded, stowed, and secured throughout the voyage in accordance with the Cargo Securing Manual approved by the Administration. No cargo Securing Manual approved by Flag State of the vessel on board. 74SOLAS(14 Cons.) CH VI Reg. 5.6 17bc
Action required: 17 - Rectify deficiencies prior to departure
Due 22 February 2017
Resolved 13 February 2017
Resolution: Cargo Securing Manual approved by Flag - Checked and Verified for new Flag approval stamp on the Cargo Securing Manual, manual is approved.
Navigation › Piloting/Steering › Gyro Compass
Issued 28 July 2016
Resolved
1540 - Navigation - The condition of the ship and its equipment shall be maintained fit to proceed to sea. Vessel is fitted with a Gyrocompass, however it is inoperable. 74 SOLAS 14 con. I/11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 19 August 2016
Resolution: Received Flag report attesting to repair, def cleared.
Communications › Long Range Identification and Tracking (LRIT) › Transmission Unit
Issued 28 July 2016
Resolved
1699 - Radio other - Ships shall be fitted with system to automatically transmit info specified. Conformance test report should be issued on satisfactory completion of test by Admin. LRIT test has been completed, however the Admin has not issued acceptance of the test. 74 SOLAS 14 con. V/19-1.4.1
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Resolved 19 August 2016
Resolution: Received Flag Report, def cleared.
Navigation › Piloting/Steering › Marine Charts
Issued 28 July 2016
Resolved
1560 - Charts - nautical charts shall be adequate and up to date. Charts were not up to date. 74 SOLAS 14 con. V/27
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 July 2016
Resolution: Charts were corrected with the latest updates.
Electrical › Electric Generation Source (emergency) › Generator
Issued 24 June 2014
Resolved
0945: Cargoships 5000GT and below there shall be a self-contained emergency source of power located to the satisfaction of the administration. The emergency diesel generator located in the fore-peak is inoperable. 60 SOLAS II / 26(b)(i)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2014
Resolution: PSCO Observed a working emergency generator by conducted a test run and an on-load test.
Construction/Loadline › Structures › Deck Plating
Issued 24 June 2014
Resolved
0988: The vessel's number two cargo hold on the starboard side main deck has several 15 millimeter in diameter size holes that penetrate through the deck to the cargo hold. Fore-peak hold starboard side, outboard of the emergency generator, there are several 10 milimeteter in diameter holes that penetrate the deck to the fore-peak hold. ICLL 66 AI / 1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2014
Resolution: PSCO verified new metal decking was welded in place to ensure no holes were visible. Wastage in immediate area of emergency generator and starboard side deck IVO cargo hold #2 were eliminated.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 24 June 2014
Resolved
0615: before the ship leaves port and at all times during the voyage, all live-saving appliances shall be in working order and ready for immediate use. The vessel’s rescue boat motor is inoperable. 74 SOLAS (09 Cons.) III / 20.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2014
Resolution: PSCO verified satisfactory operation of rescue boat outboard.
Navigation › Piloting/Steering › Gyro Compass
Issued 24 June 2014
Resolved
1540: All ships 500 GT and upwards shall have a gyro-compass to display their heading by ship borne non-magnetic means being clearly readable by the helmsman at the steering position. Vessel's Gyrocompass unit and repeater are inoperable. 74 SOLAS (09 Cons.) V/ 19.2.5.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2014
Resolution: PSCO verified satisfactory operation of vessel''s gyrocompass and repeater.
Lifesaving › Inflatable Liferafts › Float Free
Issued 24 June 2014
Resolved
0628: Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The starboard side life raft and starboard side quick release ring bouy were strapped down to the ship which made them not ready for immediate use. 74 SOLAS (09 Cons.) III / 20.2
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 June 2014
Resolved 24 June 2014
Resolution: Vessel removed the ratchet tie-down that secured the liferaft to the deck bypassing the reqired float-free design
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 23 June 2014
Resolved
0740: In a cargo ship if a fire in anyone compartment could put all the pumps out of action there must be an alternative means for providing water for firefighting. The vessel's emergency fire pump is inoperable. It operates off electrical power from emergency generator. 60 SOLAS II / 65(b)(ii)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2014
Resolution: PSCO observed a working emergency fire pump via two jets of water supplying sufficient pressure fwd/aft.
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 18 March 2014
Resolved
0111 - Previous certificate invalidated after annual verification was not conducted in appropriate time frame. Request Recognized Organization provide supporting documentation on type and scope of surveys conducted on December 27, 2013 for which the current certificates is based. 74 SOLAS (09) CH I/Reg 12.a.ii
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2014
Resolution: Vessel provided documentation of survey.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 18 March 2014
Resolved
0120 - Previous certificate invalidated after annual verification was not conducted in appropriate time frame. Request Recognized Organization provide supporting documentation on type and scope of surveys conducted on December 27, 2013 for which the current certificate is based. 74 SOLAS (09) CH XI-2/Reg 4.2 ISPS Code Part A/Reg 19.3.8
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2014
Resolution: Vessel provided documentation of survey.
Documentation › Certificates/Documents › IOPP Certificate
Issued 18 March 2014
Resolved
0150 / 0199 - Previous IOPP and IAPP certificates invalidated after annual verification was not conducted in appropriate time frame. Request Recognized Organization provide supporting documentation on type and scope of surveys conducted on December 27, 2013 for which the current certificate is based. 73 MARPOL (11) Annex I/CH2/Reg 7.1 & Annex VI/CH 2.6.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2014
Resolution: Vessel provided documentation of survey.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 18 March 2014
Resolved
1240 - The construction and means for securing the weathertightness of cargo and other hatchways shall be weathertight and fitted with gaskets and clamping devices. Multiple cargo hatch covers are not fitted with gaskets and deteriorated with numerous holes - severely compromising weathertight integrity. 66 ICLL (88) Reg 14.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2014
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 18 March 2014
Resolved
0230 - All ships shall be sufficiently and efficiently manned. Vessel did not have Chief Engineer available or documentation of a Chief Engineer attached to the ship as required by the vessel's Safe Manning Certificate. 74 SOLAS (09) CH V/Reg 14.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2014
Construction/Loadline › Structures › Superstructure
Issued 18 March 2014
Resolved
1260 - Openings in freeboard deck shall be protected by an enclosed superstructure, or by a deckhouse or companionway of equivalent strength and weathertightness. Bridge window pane missing, temporary repairs not weathertight. 66 ICLL (88) Reg 18.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2014
Lifesaving › Rescue Boat Equipment › Electric Torch
Issued 18 March 2014
Resolved
0616 - Rescue boat was not supplied with: a waterproof electric torch, spare batteries, and a spare bulb; a first-aid outfit; and a searchlight capable of working continuously for not less than 3 hours. 74 SOLAS (01) CH III/Reg 31.2 LSA Code CH V Reg 5.1.2.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2014
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 18 March 2014
Resolved
0635 - Rescue boats shall be stowed in a state of continuous readiness for launching in not more than 5 minutes. Rescue boat took an excess of 15 minutes to launch. 74 SOLAS (01) CH III/Reg 14.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2014
Lifesaving › Lifebuoys › Self-Activitating Smoke Signals
Issued 18 March 2014
Resolved
0650 - At least two of the lifebuoys provided with self-igniting lights shall also be provided with an efficient self-activating smoke signal capable of producing smoke of highly visible color for at least 15 minutes. Smoke signals on the bridge wings have no servicing or expiration date, unable to determine validity or ability of equipment to complete its function. 60 SOLAS CH III/Reg 21(g)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 March 2014
Resolved
0950 - All exposed metal parts of electrical machines or equipment shall be so constructed and so installed that danger of injury or ordinary handling shall not exist. 01 light receptacle and 02 power outlets were found to have exposed wires. SOLAS (60) CH II/Reg 27a.i.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2014
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 18 March 2014
Resolved
9900 - A ship must have a fixed container or enclosed deck area under or around each fuel oil or bulk lubricating oil tank vent, overflow, and fill pipe. Hole observed containment surrounding BR1C tank vent. 33 CFR 155.320(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2014
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 18 March 2014
Resolved
0620 - The liferaft shall be so stowed as to be readily available in case of emergency. All liferafts improperly secured to the deck. Quick-release configuration incorrectly rigged and extra straps used to secure life raft. SOLAS (60) CH III/Reg 15(p)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 March 2014
Resolved 18 March 2014
Resolution: Quick-release configuration correctly rigged and extra straps removed during exam.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 23 February 2012
Resolved
The view from the conning position shall not be obstructed by more than two ship lengths forward of the bow to 10 degrees on either side under all conditions of draught, trim and deck cargo. vessel cargo loaded in such a way that the view from the conning position is restricted by more than two ship lengths.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2012
Resolution: Vessel removed about 15 feet of cargo from their forward section. Angle needed for proper line of sight had been established.
Fire Fighting › Fire Pumps › Pressure
Issued 12 December 2011
Resolved
In a cargo ship of 1000 GT and upwards, if a fire in any one compartment could pit all the pumps out of action, there must be an alternative means of providing water for fire fighting. Emergency fire pump (the required alternative means for firefighting water) does not provide adequate water supply to forward and aft hoses. SOLAS 60 II/65(b)(i)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2012
Navigation › Collision/Grounding Avoidance › Radar
Issued 12 December 2011
Resolved
All ships of 300 GT and upwards shall be fitted with.. a 9 GHz radar... to determine and display the range and bearing of radar transponders... to assist in navigation and in collision avoidance. Both radars on bridge are out of calibration and do not show proper heading. SOLAS 74 (09) V.19.2.3.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2012
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 12 December 2011
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2012
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 December 2011
Resolved
A lifebuoy shall satisfy the following requirements... It shall be marked in block letters with the name and port of registry of the ship in which it is carried. 02 lifebuoys on forecastle are not marked with vessel's port of registry. SOLAS 60 Ch 3 Reg 21(a)(v)
Action required: 705 - Other - as specified
Due 19 December 2011
Resolved 6 January 2012
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 8 September 2010
Resolved
Several oil containments around the vessel are missing plugs
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2010
Lifesaving › Rescue Boat Equipment › Rescue Quoit
Issued 8 September 2010
Resolved
Vessels rescue boat is missing 01 resue quoit. Also the signal lamp does not work and the fire extinguisher is empty.
SOLAS 74 CH. III/ Reg 31.2
LSA Code 5.1.2.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2010
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 8 September 2010
Resolved
Vessel has no current list of lights, sailing directions or radio navigation aids.
SOLAS 74 Ch. V/ Reg 27
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2010
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 8 September 2010
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 21 September 2010
Engineering › Fuel Oil Service System › Pump
Issued 8 September 2010
Resolved
Vessels fuel oil pump is leaking a steady drip of fuel into two collection pans.
SOLAS 60 Ch. I/ Reg. 11
Action required: 705 - Other - as specified
Resolved 21 September 2010
Engineering › Lubricating Oil Service System › Pump
Issued 8 September 2010
Resolved
Vessel has multiple lube oil pumps leaking in engine room and on deck.
SOLAS 60 Ch.I/ Reg 11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2010
Electrical › Lighting (service) › Lighting Fixture
Issued 8 September 2010
Resolved
Numerous light fixtures throughout the vessel are broken.
SOLAS 74 CH. II-1/ Reg. 45.1.3
Due 15 September 2010
Resolved 21 September 2010
Construction/Loadline › Structures › Air Pipe
Issued 8 September 2010
Resolved
Numerous air pipe closure devices cannot be secured shut due to wastage.
ICLL 66 Annex I/ Reg. 20
Action required: 705 - Other - as specified
Resolved 21 September 2010
Construction/Loadline › Structures › Door
Issued 8 September 2010
Resolved
The door to the forepeak is warped and cannot be secured shut.
ICLL 66 Annex I/ Reg. 12.1
Action required: 705 - Other - as specified
Resolved 21 September 2010
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 8 September 2010
Resolved
Port and Starboard liferaft hydrostatic release units expired 1 month ago( August 2010).
SOLAS 74 (09 Cons.) Ch. III/ Reg. 20.9.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2010
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 25 August 2008
Resolved
Vessel does not have tide tables onboard.
Due 8 September 2008
Resolved 27 August 2008
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 25 August 2008
Resolved
Solas safety radio and equipment certificates are expired. Annuyal surveys have been completed.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 August 2008
Resolved 27 August 2008
Construction/Loadline › Markings › Load Line Mark
Issued 10 January 2008
Resolved
Vsl did not have deck line as per their ILLC.
Action required: 705 - Other - as specified
Due 17 January 2008
Resolved 22 May 2008
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 10 January 2008
Resolved
Vsl was unable to give evidence of last two dry dock inspections.
Action required: 705 - Other - as specified
Due 17 January 2008
Resolved 29 July 2016
Resolution: vsl provided documentation from flag. Vsl had dry dock in 2003 and 2005
Construction/Loadline › Markings › Load Line Mark
Issued 20 March 2007
Resolved
Loadline letters symbolizing the region do not match the letters on the certificate.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 March 2007
Resolved 22 May 2008
Documentation › Logs/Records › Ballast Water Reporting Form
Issued 29 June 2005
Resolved
Missing Ballast water management plan, vessel is not submitting ballast water reporting forms prior to entry of US port
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 July 2005
Resolved 27 July 2005
Resolution: Received fax from flag state.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 29 June 2005
Resolved
Loadline markings do not match with loadline certificate.
Action required: 705 - Other - as specified
Due 30 July 2005
Resolved 12 July 2005
Fire Fighting › Structural - A Class Divisions
Issued 6 April 2004
Resolved
Doors located in the aft engine room bulkhead not properly insulated and sealed around the door frame and do not meet A-60 fire integrity requirements. LEGACY COMPONENT DESC: Openings - Doors & Door Frames
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2004
Resolved 21 May 2004
Fire Fighting › Structural - A Class Divisions
Issued 6 April 2004
Resolved
Hole in aft engine room bulkhead on the prot side of the engine room escape trunk door one foot off of the deck. Properly repair hole. LEGACY COMPONENT DESC: Bulkheads - Machinery Spaces
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2004
Resolved 21 May 2004
Construction/Loadline › Structures
Issued 6 April 2004
Resolved
Door leading to the fantail on the port side of the galley does not properly seal and is not watertight. Properly repair repair door to seal correctly. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2004
Resolved 21 May 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 6 April 2004
Resolved
Main engine jacket water leaking around cylinders 1-5 and exhaust leaks found on exhaust piping near cylinders 5-8. Properly repair all leaks and have Flag State address maintenance deficiencies within the safety management sytstem and why no non conformities were not issued. LEGACY COMPONENT DESC: Cylinder Liner & Exhaust Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2004
Resolved 21 May 2004
Electrical › Electric Generation Source (emergency)
Issued 12 November 2003
Resolved
Sight glass for emergency generator fuel day tank is not properly installed. Needs a permanent proper installation. 60 SOLAS II/26 LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Due 12 December 2003
Resolved 28 December 2003
Electrical › Electrical Distribution System (emergency)
Issued 12 November 2003
Resolved
Exposed wiring in junction box in way of e-generator fuel day tank. There's also dead ended wires by main switchboard. Removed all dead end wires or terminate in a box. 60 SOLAS II/27 LEGACY COMPONENT DESC: Junction Box
Condition: Improper/Lack of Maintenance
Due 12 December 2003
Resolved 28 December 2003
Deck/Cargo › Cargo Stowage
Issued 12 November 2003
Resolved
Flammables found storwed inside Emergency Generator Room. Removed flammables from room to a proper location. 60 SOLAS VII/7(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2003
Fire Fighting › Combustible Materials
Issued 12 November 2003
Resolved
Insulation on Emergency Generator exhaust is improper and is causing smoke build-up in room. Provide proper installation. 60 SOLAS II/27 LEGACY COMPONENT DESC: Insulation
Condition: Improper/Lack of Maintenance
Due 12 December 2003
Resolved 28 December 2003
Personnel › Certificates/Documents/Licenses
Issued 10 April 2002
Resolved
Provide A/B IAW "Minimum Safe Manning" Certificate with proper STCW 95 endorsements (A/B has STCW 78 Certificates). LEGACY COMPONENT DESC: STCW Endorsement
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2002
Resolved 10 April 2002
Resolution: Provide proper documentation.
Fire Fighting › Fire Hoses
Issued 10 April 2002
Resolved
Replace fire hose in engine room starboard side lower level. Hose is dry rotten and leaking. LEGACY COMPONENT DESC: Connections
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2002
Resolved 10 April 2002
Resolution: Provided new hoses in Engine room.
Pollution Prevention/Response › Prevention Equipment
Issued 10 April 2002
Resolved
Demonstrate operation of Oily Water Separator, impellers are on order. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 10 May 2002
Resolved 15 May 2002
Resolution: Observed operation.
Communications › Alarms/Indicators
Issued 10 April 2002
Resolved
Demonstrate operation of General Alarms in Engine Room, alarms are not working. LEGACY COMPONENT DESC: General Alarm
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2002
Resolved 10 April 2002
Resolution: Repaired and tested.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 10 April 2002
Resolved
Repair exhaust leak to forward generator in forecastle. LEGACY COMPONENT DESC: Exhuast Leak
Action required: 705 - Other - as specified
Due 10 May 2002
Resolved 15 May 2002
Resolution: Corrected.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 10 April 2002
Resolved
Provide guard for fly wheel forforward generator in forecastle. LEGACY COMPONENT DESC: Guard for fly wheel
Action required: 705 - Other - as specified
Due 10 May 2002
Resolved 15 May 2002
Resolution: Corrected.
Engineering › Generator (propulsion-electric)
Issued 10 April 2002
Resolved
Replace the discharge side piping of #2 Generator cooling line. Pipe has soft patch. LEGACY COMPONENT DESC: Cooling Line Piping
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2002
Resolved 15 May 2002
Resolution: Corrected.
Pollution Prevention/Response › Prevention Equipment
Issued 10 April 2002
Resolved
Pump out all bilge water in Engine Room and slop/oil residue tank. Provide receipts of removal. LEGACY COMPONENT DESC: Remove slops
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2002
Resolved 10 April 2002
Resolution: Provided documentation from CBI of removal.
Engineering
Issued 28 March 2001
Resolved
Provide proof of proper operation of OWS to the satisfaction of class and provide report to USCG MSO Miami via fax.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Documentation
Issued 20 June 2000
Resolved
PRIOR TO DEPARTURE PROVIDE NEW CARGO SHIP SAFETY RADIO CERTIFICATE WITH "SEA AREA A3" LISTED.
Condition: Unknown
Due 20 June 2000
Resolved 21 June 2000
Documentation
Issued 20 June 2000
Resolved
PRIOR TO DEPARTURE PROVIDE CURRENT COFR FOR VSL.
Condition: Unknown
Due 20 June 2000
Resolved 21 June 2000
Unknown
Issued 22 February 2000
Resolved
PROVIDE FINAL CLASS REPORT OF ALL OUTSTANDING DEFICIENCIES AFTER DRYDOCK TOMSO MIAMI. PRIOR TO PLACING VESSEL INTO COMMERCIAL OPERATION IN THE U.S. AFTER DRYDOCK.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Lifesaving
Issued 14 October 1996
Resolved
PROVIDE SOLAS TRAINING MANUAL TAILORED TO VESSEL.
Condition: Unknown
Due 14 October 1996
Resolved 29 October 1996
Fire Fighting
Issued 14 October 1996
Resolved
PROVIDE SPARE BOTTLES FOR BOTH FIRE SUITS (NEED 01 EXTRA COMPATIBLE W/ EACHSUIT.
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Lifesaving
Issued 14 October 1996
Resolved
COMPLETE ITEMS 01-17 FOR CASE #PS96097586 PRIOR TO 17OCT96 OR PROVIDE APPROVED LAY-UP PROPOSAL TO U.S.C.G. MSO MIAMI.
Condition: Unknown
Due 17 October 1996
Resolved 29 October 1996
Fire Fighting
Issued 14 October 1996
Resolved
CONDUCT PROPER FIRE DRILL/CONDUCT CREW TRAINING PRIOR TO RE-EXAM.
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Lifesaving
Issued 14 October 1996
Resolved
REVISE TRAINING MANUAL TO REFLECT SHIP'S EQUIPMENT AND IN A LANGUAGE UNDERSTOOD BY THE CREW. (CREW SPEAKS SPANISH)
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Construction/Loadline
Issued 14 October 1996
Resolved
CLASS/FLAG SURVEYOR TO ADDRESS PERMANENT REPAIRS TO TWO DOUBLERS: 1) ON TIPOF BULBOUS BOW(OUTSTANDING SINCE MAR96) AND 2) PORT SIDE DIRECTLY BENEATH 2ND FREEING PORT IN WAY OF FORWARD CARGO HOLD.
Condition: Unknown
Due 14 October 1996
Resolved 13 November 1996
Lifesaving
Issued 14 October 1996
Resolved
PROVIDE EMBARKATION LADDERS FOR PORT AND STARBOARD LIFERAFT STATIONS.
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Documentation
Issued 14 October 1996
Resolved
PROVIDE ON BOARD VALID SOPEP.
Condition: Unknown
Due 14 October 1996
Resolved 29 October 1996
Navigation
Issued 14 October 1996
Resolved
PROVIDE MARINE TYPE BULBS FOR ALL NAVIGATION LIGHTS. (REPLACE HOUSEHOLD INCANDESCENT)
Condition: Unknown
Due 14 October 1996
Resolved 29 October 1996
Accommodation/Occupational Safety
Issued 14 October 1996
Resolved
PROVIDE MEANS TO STOP DIRECT FLOW OVERBOARD FROM MARINE SANITATION DEVICE.
Condition: Unknown
Due 14 October 1996
Resolved 29 October 1996
Documentation
Issued 14 October 1996
Resolved
PROVIDE DRYDOCK REPORT OR SURVEYOR'TS REPORT ADDRESSING REPAIRS MADE TO PORT BOW AFTER COLLISION.
Condition: Unknown
Due 14 October 1996
Resolved 13 November 1996
Engineering
Issued 14 October 1996
Resolved
PROPERLY FILL OUT OIL RECORD BOOK- VSL HAS NOT PROPERLY RECORDED REMOVAL OFOILY WASTES IN THE PAST FIVE MONTHS. VSL DIAGRAM/TANK DIAGRAMS WAS NOT PROPERLY INCLUDED. CHIEF ENGINEER WAS IMPROPERLY USING TANK VESSEL CODES INSTEAD OF CARGO VESSEL CODES.
Condition: Unknown
Due 14 October 1996
Resolved 29 October 1996
Engineering
Issued 14 October 1996
Resolved
PROVIDE PLUGS FOR FUEL/OIL CONTAINMENT AROUND VENTS AND FILLS.
Condition: Unknown
Due 14 October 1996
Resolved 29 October 1996
Engineering
Issued 14 October 1996
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR.
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Lifesaving
Issued 14 October 1996
Resolved
PROVIDE LIGHT COVERS FOR ALL BARE BULBS IN ALL MACHINERY SPACES/ PROVIDE BATTERY BOXES FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Documentation
Issued 14 October 1996
Resolved
PROVIDE VALID COFR, LOAD LINE AND CERTIFICATE OF REGISTRY ON BOARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 October 1996
Resolved 15 October 1996
Documentation
Issued 14 October 1996
Resolved
PROPERLY CONDUCT ALL REQUIRED DRILLS AND TRAINING - include life saving gear/ equipment/ general alarm, AND LOG IN DECK LOG.
Condition: Unknown
Due 14 October 1996
Resolved 29 October 1996
Documentation
Issued 14 October 1996
Resolved
PROVIDE VALID SAFETY EQUIPMENT CERTIFICATE AND FORM "E" WHICH ACCURATELY REFLECTS LIFERAFT/LIFEBOAT/RESCUE BOAT/IMMERSION SUIT CONFIGURATION OR PROVIDE 01 ADDITIONAL LIFEBOAT, 01 LIFERAFT, AND 07 ADDITIONAL IMMERSION SUIT I.A.W. CURRENT CERTIFICATE.
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Documentation
Issued 14 October 1996
Resolved
PROVIDE VALID MEDICAL CERTIFICATES FOR ALL CREW MEMBERS.
Condition: Unknown
Due 14 October 1996
Resolved 29 October 1996
Documentation
Issued 14 October 1996
Resolved
PROVID VALID IOPP FORM "A" PROPERLY ANNOTATED WITH VESSEL REQUIREMENTS.
Condition: Unknown
Due 14 October 1996
Resolved 29 October 1996
Lifesaving
Issued 14 October 1996
Resolved
PROVIDE 02 ADDITIONAL LINE THROWING DEVICES (FOR A TOTAL OF FOUR)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 October 1996
Resolved 29 October 1996
Construction/Loadline
Issued 30 March 1996
Resolved
No person may intentionally drain oil or hazardous material from any sourceinto the bilge of a vessel.
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Fire Fighting
Issued 30 March 1996
Resolved
Fire Control Plan not posted. Equipment placement is not according to FireControl Plan.
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Construction/Loadline
Issued 30 March 1996
Resolved
Make permanent repairs to shell plate in way of #1 cargo hold_x001C_
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Construction/Loadline
Issued 30 March 1996
Resolved
Make permanent repair to shell plate (doubler type plate patch) on bulbous bow.
Condition: Unknown
Due 24 February 2000
Resolved 21 June 2000
Construction/Loadline
Issued 30 March 1996
Resolved
Make repairs to shell plate in way of port and starboard chain locker/peak tank (holes in shell plate).
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Unknown
Issued 30 March 1996
Resolved
Owner, master, agent or person in charge failed to immediately notify the Captain of the Port of the port or place of destination and the Captain of the Port of the port or place in which the vessel is located of a hazardouscondition.
Condition: Unknown
Due 9 April 1997
Resolved 23 February 2000
Documentation
Issued 30 March 1996
Resolved
Conduct Survey on hull & machinery. Vessel to provide following certificates prior to entry: Loadline Certificate, Cargo Ship Safety Construction Certificate, & Cargo Ship Safety Equipment Certificate.
Condition: Unknown
Due 14 October 1996
Resolved 14 October 1996
Construction/Loadline
Issued 30 March 1996
Resolved
Make permanent repairs to (holes) port WTD to engine room & superstructure adjacet to WTD.
Condition: Unknown
Due 14 October 1996
Resolved 14 October 1996
Construction/Loadline
Issued 30 March 1996
Resolved
Make permanent repairs to holes in superstructure plate inboard of forewardladder ways: Starboard at top of ladder, & Port side mid highth of ladder (stripped threads on plug).
Condition: Unknown
Due 14 October 1996
Resolved 14 October 1996
Construction/Loadline
Issued 30 March 1996
Resolved
Cargo hatches missing gaskets.
Condition: Unknown
Due 14 October 1996
Resolved 14 October 1996
Construction/Loadline
Issued 30 March 1996
Resolved
Make permanent repairs to (set in and crushed plate) tank top in #2 cargo hold port side adjcent to shell plate.
Condition: Unknown
Due 14 October 1996
Resolved 14 October 1996
Fire Fighting
Issued 30 March 1996
Resolved
Repair emergency fire pump.
Condition: Unknown
Due 14 October 1996
Resolved 14 October 1996
Construction/Loadline
Issued 30 March 1996
Resolved
An oceangoing ship of 400 gross tons and above must be fitted with a standerd discharge connection, for the discharge to reception facility, of oily wastes from machinery space bilges or fuel oil tanks ballast water.
Condition: Unknown
Due 14 October 1996
Resolved 14 October 1996
Construction/Loadline
Issued 30 March 1996
Resolved
Make permanent repairs to (Collision damage) forecastle_x001C_ Holes and fractures in deck plating._x001C_
Condition: Unknown
Due 14 October 1996
Resolved 14 October 1996
Electrical
Issued 30 March 1996
Resolved
Make repairs (engine disassembled) to emergency generator's diesel prime mover.
Condition: Unknown
Due 14 October 1996
Resolved 14 October 1996
Electrical
Issued 30 March 1996
Resolved
Make repairs to NO.1 Generator (engine disassembled)._x001C_
Condition: Unknown
Due 14 October 1996
Resolved 14 October 1996
Navigation
Issued 3 October 1995
Resolved
Prior to departing Port of Tampa, provide onboard U.S. Coast Pilot [name withheld], Tidal Current Tables, Inland Nav Rules or foreign equilvalants. SOLAS 74 V/20.
Condition: Unknown
Due 12 October 1995
Resolved 12 October 1995
Documentation
Issued 3 October 1995
Resolved
Prior to departing Port of Tampa, provide record of Equipment (Form E) Supplement to cargo Ship Safety Equipment Certificate. 60 SOLAS I/16,19.
Condition: Unknown
Due 12 October 1995
Resolved 12 October 1995
Documentation
Issued 21 September 1995
Resolved
provide onboard valid loadline cert and permanently enscribe markings on hull iaw loadline cert.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Fire Fighting
Issued 21 September 1995
Resolved
make operable main fire pump in engine room and prove to class.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Documentation
Issued 21 September 1995
Resolved
provide onboard equipment supplement for safety equipment cert.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Engineering
Issued 21 September 1995
Resolved
make perm repairs to all auxillary machinery leaking excessive oil and provide class acceptance/verification.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Engineering
Issued 21 September 1995
Resolved
make perm repairs to waste oil piping in mach spaces (leaking) and provide class acceptance/verification.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Lifesaving
Issued 21 September 1995
Resolved
provide onboard lifeboat with all required solas equip (msg food, first aidkit, sea anchor, hatchets, lifeboat motor tools, fitted with outboard motor) and provide class acceptance/verification.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Lifesaving
Issued 21 September 1995
Resolved
provide evidence of last renewal date, end for end date for lifeboat wire falls and provide class acceptance/verification.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Fire Fighting
Issued 21 September 1995
Resolved
provide verification from class that fixed agent supply is sufficient for engine room.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Fire Fighting
Issued 21 September 1995
Resolved
provide evidence of servicing for all fixed C02/ halon systems.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Fire Fighting
Issued 21 September 1995
Resolved
provide evidence of servicing for all portable fire extinguishers.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Construction/Loadline
Issued 21 September 1995
Resolved
Vessel to conduct drydock inspection no later than 30 Oct 95 as per safety construction certificate endorsement and provide hull and tank top guagings._x001C_
Condition: Unknown
Due 12 February 1996
Resolved 12 February 1996
Fire Fighting
Issued 21 September 1995
Resolved
provide onboard two spare breathing bottles (one for each fireman outfit) and provide class acceptance/verification.
Condition: Unknown
Due 12 October 1995
Resolved 12 October 1995
Fire Fighting
Issued 21 September 1995
Resolved
make perm repairs to wasted piping iwo main fire pump in engine room and prove to class.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Fire Fighting
Issued 21 September 1995
Resolved
make operable 2nd firepump (general service pump located in engine room) and prove to class.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Fire Fighting
Issued 21 September 1995
Resolved
make perm repairs to all on deck fire main piping (wasted with soft patchesthroughout) and prove to class.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Fire Fighting
Issued 21 September 1995
Resolved
make perm repairs to wasted piping iwo 2nd fire pump(general ballast pump) in engine room and prove to class.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Fire Fighting
Issued 21 September 1995
Resolved
provide onboard 2nd fireman outfit and provide class acceptance/verification.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Lifesaving
Issued 21 September 1995
Resolved
replace wasted partial lifeline on lifeboat and provide class acceptance/verification.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Lifesaving
Issued 21 September 1995
Resolved
Properly attach weak link to liferaft sea painter to provide for float freeoperation._x001C_
Condition: Unknown
Due 30 September 1995
Resolved 30 September 1995
Navigation
Issued 7 April 1994
Resolved
Vessel did not have a current copy of the tidal current tables, this is a violation of SOLAS Chapter V, Reg. 20.
Condition: Unknown
Due 8 April 1994
Resolved 11 April 1994
Navigation
Issued 7 April 1994
Resolved
Vessel did not have currently corrected copy of the light list, this is a violation of SOLAS Chapter V, Reg. 20.
Condition: Unknown
Due 8 April 1994
Resolved 11 April 1994
Navigation
Issued 7 April 1994
Resolved
Vessel did not have a current copy of the tide tables, this is a violation of SOLAS Chapter V, Reg. 20.
Condition: Unknown
Due 8 April 1994
Resolved 11 April 1994
Navigation
Issued 7 April 1994
Resolved
Vessel did not have a currently corrected copy of the coast pilot, this is a violation of SOLAS Chapter V, Reg. 20.
Condition: Unknown
Due 8 April 1994
Resolved 11 April 1994
Navigation
Issued 7 April 1994
Resolved
Steering gear testing and drills not recorded in the vessels log book. thisis a violation of SOLAS Chapter V, Reg. 19-2(a).
Condition: Unknown
Due 9 April 1994
Resolved 11 April 1994
Navigation
Issued 7 April 1994
Resolved
Vessel did not have operating instructions and a block diagram for the steering gear, this is a violation of SOLAS Chapter V, Reg. 19-2(c)(i)
Condition: Unknown
Due 8 April 1994
Resolved 11 April 1994
Documentation
Issued 6 June 1991
Resolved
A VIO OF 33CFR155.740 IN THAT THE OIL TRANSFER PROCEDURES REQ BY 33CFR155.720 WERE NOT AVAILABLE FOR INSPECTION BY THE COTP.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Documentation
Issued 18 July 1990
Resolved
A VIO OF 33 CFR 155.740(A) IN THAT THE OTP REQ BY 33 CFR 155.720 WERE NOT_x001C_ AVAILABLE FOR INSPECTION BY THE COTP WHEN THE VSL WAS IN OPERATION._x001C_ _x001C_
Condition: Unknown
Due 6 June 1991
Resolved 18 July 1990
Unknown
Issued 18 July 1990
Resolved
A VIO OF 33 CFR 155.450 IN THAT THE VSL DID NOT HAVE O/B A DISCHARGE OF_x001C_ OIL PROHIBITED PLACARD POSTED IN EITHER EACH MACHINERY SPACE OR AT THE_x001C_ BILGE AND BALLAST PUMP CONTROL STATION.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Unknown
Issued 18 July 1990
Resolved
A VIO OF 33 CFR 159.7 IN THAT THE VSL MSD WAS NOT LABLED, AS REQ BY 33_x001C_ CFR 159.16, OR CERTIFIED AS PROVIDED UNDER 33 CFR 159.12 OR 33 CFR 159.12_x001C_ (A)
Condition: Unknown
Due 6 June 1991
Resolved 18 July 1990